Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
J Biomed Opt ; 28(10): 102907, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37576611

RESUMO

Significance: Successful differentiation of carcinoma in situ (CIS) from inflammation in the bladder is key to preventing unnecessary biopsies and enabling accurate therapeutic decisions. Current standard-of-care diagnostic imaging techniques lack the specificity needed to differentiate these states, leading to false positives. Aim: We introduce multiparameter interferometric polarization-enhanced (MultiPIPE) imaging as a promising technology to improve the specificity of detection for better biopsy guidance and clinical outcomes. Approach: In this ex vivo study, we extract tissue attenuation-coefficient-based and birefringence-based parameters from MultiPIPE imaging data, collected with a bench-top system, to develop a classifier for the differentiation of benign and CIS tissues. We also analyze morphological features from second harmonic generation imaging and histology slides and perform imaging-to-morphology correlation analysis. Results: MultiPIPE enhances specificity to differentiate CIS from benign tissues by nearly 20% and reduces the false-positive rate by more than four-fold over clinical standards. We also show that the MultiPIPE measurements correlate well with changes in morphological features in histological assessments. Conclusions: The results of our study show the promise of MultiPIPE imaging to be used for better differentiation of bladder inflammation from flat tumors, leading to a fewer number of unnecessary procedures and shorter operating room (OR) time.


Assuntos
Carcinoma in Situ , Neoplasias da Bexiga Urinária , Humanos , Bexiga Urinária/diagnóstico por imagem , Bexiga Urinária/patologia , Tomografia de Coerência Óptica/métodos , Sensibilidade e Especificidade , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Inflamação/diagnóstico por imagem , Inflamação/patologia
2.
Artigo em Inglês | MEDLINE | ID: mdl-37034554

RESUMO

Accelerating innovation in the space of fluorescence imaging for surgical applications has increased interest in safely and expediently advancing these technologies to clinic through Food and Drug Administration-(FDA-) compliant trials. Conventional metrics for early phase trials include drug safety, tolerability, dosing, and pharmacokinetics. Most procedural imaging technologies rely on administration of an exogenous fluorophore and concurrent use of an imaging system; both of which must receive FDA approval to proceed to clinic. Because fluorophores are classified as medical imaging agents, criteria for establishing dose are different, and arguably more complicated, than therapeutic drugs. Since no therapeutic effect is desired, medical imaging agents are ideally administered at the lowest dose that achieves adequate target differentiation. Because procedural imaging modalities are intended to enhance and/or ease proceduralists' identification or assessment of tissues, beneficial effects of these technologies may manifest in the form of qualitative endpoints such as: 1) confidence; 2) decision-making; and 3) satisfaction with the specified procedure. Due to the rapid expansion of medical imaging technologies, we believe that our field requires standardized criteria to evaluate existing and emerging technologies objectively so that both quantitative and qualitative aspects of their use may be measured and useful comparisons to assess their relative value may occur. Here, we present a 15-item consensus-based survey instrument to assess the utility of novel imaging technologies from the proceduralist's standpoint.

3.
Laryngoscope ; 133(11): 3208-3215, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-36866696

RESUMO

OBJECTIVES: Compared to adult patients undergoing thyroid surgery, pediatric patients have higher rates of hypoparathyroidism often related to parathyroid gland (PG) inadvertent injury or devascularization. Previous studies have shown that near-infrared-autofluorescence (NIRAF) can be reliably used intraoperatively for label-free parathyroid identification, but all prior studies have been performed in adult patients. In this study, we assess the utility and accuracy of NIRAF with a fiber-optic probe-based system to identify PGs in pediatric patients undergoing thyroidectomy or parathyroidectomy. METHODS: All pediatric patients (under 18 years of age) undergoing thyroidectomy or parathyroidectomy were enrolled in this IRB-approved study. The surgeon's visual assessment of tissues was first noted and the surgeon's confidence level in the tissue identified was recorded. A fiber-optic probe was then used to illuminate tissues-of-interest with a wavelength of 785 nm and resulting NIRAF intensities from these tissues were measured while the surgeon was blinded to results. RESULTS: NIRAF intensities were measured intraoperatively in 19 pediatric patients. Normalized NIRAF intensities for PGs (3.63 ± 2.47) were significantly higher than that of thyroid (0.99 ± 0.36, p < 0.001) and other surrounding soft tissues (0.86 ± 0.40, p < 0.001). Based on the PG identification ratio threshold of 1.2, NIRAF yielded a detection rate of 95.8% (46/48 pediatric PGs). CONCLUSION: Our findings indicate that NIRAF detection can potentially be a valuable and non-invasive technique to identify PGs during neck operations in the pediatric population. To our knowledge, this is the first study in children to assess the accuracy of probe-based NIRAF detection for intraoperative parathyroid identification. LEVEL OF EVIDENCE: Level 4 Laryngoscope, 133:3208-3215, 2023.


Assuntos
Glândulas Paratireoides , Glândula Tireoide , Adulto , Humanos , Criança , Adolescente , Glândulas Paratireoides/diagnóstico por imagem , Glândulas Paratireoides/cirurgia , Glândulas Paratireoides/lesões , Glândula Tireoide/cirurgia , Imagem Óptica/métodos , Paratireoidectomia/métodos , Tireoidectomia/efeitos adversos , Tireoidectomia/métodos
4.
Anal Methods ; 15(9): 1188-1205, 2023 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-36799369

RESUMO

Biochemical insights into varying breast cancer (BC) phenotypes can provide a fundamental understanding of BC pathogenesis, while identifying novel therapeutic targets. Raman spectroscopy (RS) can gauge these biochemical differences with high specificity. For routine RS, cells are traditionally seeded onto calcium fluoride (CaF2) substrates that are costly and fragile, limiting its widespread adoption. Stainless steel has been interrogated previously as a less expensive alternative to CaF2 substrates, while reporting increased Raman signal intensity than the latter. We sought to further investigate and compare the Raman signal quality measured from stainless steel versus CaF2 substrates by characterizing different BC phenotypes with altered human epidermal growth factor receptor 2 (HER2) expression. Raman spectra were obtained on stainless steel and CaF2 substrates for HER2 negative cells - MDA-MB-231, MDA-MB-468 and HER2 overexpressing cells - AU565, SKBr3. Upon analyzing signal-to-noise ratios (SNR), stainless steel provided a stronger Raman signal, improving SNR by 119% at 1450 cm-1 and 122% at 2925 cm-1 on average compared to the CaF2 substrate. Utilizing only 22% of laser power on sample relative to the CaF2 substrate, stainless steel still yielded improved spectral characterization over CaF2, achieving 96.0% versus 89.8% accuracy in BC phenotype discrimination and equivalent 100.0% accuracy in HER2 status classification. Spectral analysis further highlighted increased lipogenesis and altered metabolism in HER2 overexpressing cells, which was subsequently visualized with coherent anti-Stokes Raman scattering microscopy. Our findings demonstrate that stainless steel substrates deliver improved Raman signal and enhanced spectral characterization, underscoring its potential as a cost-effective alternative to CaF2 for non-invasively monitoring cellular biochemical dynamics in translational cancer research.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Análise Espectral Raman , Aço Inoxidável/química , Lasers , Fenótipo
5.
JAMA Otolaryngol Head Neck Surg ; 149(3): 253-260, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36633855

RESUMO

Importance: Identification and preservation of parathyroid glands (PGs) remain challenging despite advances in surgical techniques. Considerable morbidity and even mortality result from hypoparathyroidism caused by devascularization or inadvertent removal of PGs. Emerging imaging technologies hold promise to improve identification and preservation of PGs during thyroid surgery. Observation: This narrative review (1) comprehensively reviews PG identification and vascular assessment using near-infrared autofluorescence (NIRAF)-both label free and in combination with indocyanine green-based on a comprehensive literature review and (2) offers a manual for possible implementation these emerging technologies in thyroid surgery. Conclusions and Relevance: Emerging technologies hold promise to improve PG identification and preservation during thyroidectomy. Future research should address variables affecting the degree of fluorescence in NIRAF, standardization of signal quantification, definitions and standardization of parameters of indocyanine green injection that correlate with postoperative PG function, the financial effect of these emerging technologies on near-term and longer-term costs, the adoption learning curve and effect on surgical training, and long-term outcomes of key quality metrics in adequately powered randomized clinical trials evaluating PG preservation.


Assuntos
Hipoparatireoidismo , Glândulas Paratireoides , Humanos , Glândulas Paratireoides/diagnóstico por imagem , Glândulas Paratireoides/cirurgia , Glândula Tireoide/diagnóstico por imagem , Glândula Tireoide/cirurgia , Verde de Indocianina , Imagem Óptica/efeitos adversos , Imagem Óptica/métodos , Tireoidectomia/métodos , Hipoparatireoidismo/etiologia
6.
Surgery ; 173(1): 67-75, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36400581

RESUMO

BACKGROUND: Recent advancements in 3-dimensional patient-derived organoid models have revolutionized the field of cancer biology. There is an urgent need for development of endocrine tumor organoid models for medullary thyroid carcinoma, adrenocortical carcinoma, papillary thyroid carcinoma, and a spectrum of benign hyperfunctioning parathyroid and adrenal neoplasms. We aimed to engineer functionally intact 3-dimensional endocrine patient-derived organoids to expand the in vitro and translational applications for the advancement of endocrine research. METHODS: Using our recently developed fine needle aspiration-based methodology, we established patient-derived 3-dimensional endocrine organoid models using prospectively collected human papillary thyroid carcinoma (n = 6), medullary thyroid carcinoma (n = 3), adrenocortical carcinoma (n = 3), and parathyroid (n = 5). and adrenal (n = 5) neoplasms. Multiplatform analyses of endocrine patient-derived organoids and applications in oncoimmunology, near-infrared autofluorescence, and radiosensitization studies under 3-dimensional in vitro conditions were performed. RESULTS: We have successfully modeled and analyzed the complex endocrine microenvironment for a spectrum of endocrine neoplasms in 3-dimensional culture. The endocrine patient-derived organoids recapitulated complex tumor microenvironment of endocrine neoplasms morphologically and functionally and maintained cytokine production and near-infrared autofluorescence properties. CONCLUSION: Our novel engineered endocrine patient-derived organoid models of thyroid, parathyroid and adrenal neoplasms represent an exciting and elegant alternative to current limited 2-dimensional systems and afford future broad multiplatform in vitro and translational applications, including in endocrine oncoimmunology.


Assuntos
Neoplasias das Glândulas Suprarrenais , Neoplasias da Glândula Tireoide , Humanos , Organoides , Microambiente Tumoral , Neoplasias da Glândula Tireoide/patologia , Neoplasias das Glândulas Suprarrenais/patologia
7.
World J Surg ; 47(2): 350-360, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36184672

RESUMO

BACKGROUND: During adrenalectomy, surgeons have traditionally relied on their subjective visual skills to distinguish adrenal glands (AGs) from retroperitoneal fat and surrounding structures, while ultrasound and exogenous contrast agents have been employed for intraoperative AG visualization, all of which have their limitations. We present a novel label-free approach that uses near-infrared autofluorescence (NIRAF) detection, which demonstrates potential for enhanced intraoperative AG visualization and efficient tumor resection during adrenalectomies. METHODS: Patients undergoing adrenalectomy or nephrectomy were enrolled for this feasibility study. NIRAF emitted beyond 800 nm was detected in vivo from AGs and surrounding tissues during open adrenalectomies or nephrectomies. NIRAF was also measured ex vivo in excised AGs following robotic adrenalectomies. NIRAF images of tissues were captured using near-infrared (NIR) camera systems, whereas NIRAF intensities were recorded concurrently using fiber-optic probe-based NIR devices. Normalized NIRAF intensities (expressed as mean ± standard error) were analyzed and compared. RESULTS: Among the 55 enrolled patients, NIRAF intensity was elevated significantly for AGs versus retroperitoneal fat and other structures. NIR images of AGs also revealed a distinct demarcation of NIRAF between adrenal cortex and other periadrenal structures. NIRAF intensity in AGs was decreased markedly in malignant adrenal tumors, while benign adrenal cortical tumors and healthy adrenal cortex exhibited the strongest NIRAF levels. CONCLUSIONS: Our preliminary findings indicate that NIRAF detection could be a promising label-free technology to enhance intraoperative AG visualization and holds immense potential for effective tumor demarcation during cortical-sparing adrenalectomies or adrenal-conserving surgeries.


Assuntos
Neoplasias das Glândulas Suprarrenais , Glândulas Suprarrenais , Humanos , Glândulas Suprarrenais/diagnóstico por imagem , Glândulas Suprarrenais/cirurgia , Paratireoidectomia/métodos , Adrenalectomia/métodos , Tireoidectomia/métodos , Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Neoplasias das Glândulas Suprarrenais/cirurgia
8.
Thyroid ; 31(10): 1558-1565, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34078120

RESUMO

Background: Accurate assessment of parathyroid gland vascularity is important during thyroidectomy to preserve the function of parathyroid glands and to prevent postoperative hypocalcemia. Laser speckle contrast imaging (LSCI) has been shown to be accurate in detecting differences in parathyroid vascularity. In this surgeon-blinded prognostic study, we evaluate the relationship between intraoperative LSCI measurements and postoperative outcomes of total thyroidectomy patients. Methods: Seventy-two thyroidectomy patients were included in this study. After thyroid resection, an LSCI device was used to image all parathyroid glands identified, and a speckle contrast value was calculated for each. An average value was calculated for each patient, and the data were grouped according to whether the patient had normal (16-77 pg/mL) or low levels of parathyroid hormone (PTH) measured on postoperative day 1 (POD1). The aim of this study was to establish a speckle contrast threshold for classifying a parathyroid gland as adequately perfused and to determine how many such glands are required for normal postoperative parathyroid function. Results: A speckle contrast limit of 0.186 separated the normoparathyroid and hypoparathyroid groups with 87.5% sensitivity and 84.4% specificity: 7 of 8 patients with low PTH on POD1 had an average parathyroid speckle contrast above this limit, while 54 of 64 patients with normal postoperative PTH had an average parathyroid speckle contrast below this limit. Taking this value as the threshold for adequate parathyroid perfusion, it was determined that only one vascularized gland was needed for normal postoperative parathyroid function: 64 of 69 patients (92.8%) with at least one vascularized gland (determined by LSCI) had normal postoperative PTH, while all 3 patients (100%) with no vascularized glands had low postoperative PTH. Overall, the rates of temporary and permanent hypoparathyroidism in this study were 8.3% and 1.4%, respectively. Conclusions: LSCI is a promising technique for assessing parathyroid gland vascularity. It has the potential to help reduce the incidence of hypocalcemia after thyroidectomy by providing surgeons with additional information during surgery to aid in the preservation of parathyroid function.


Assuntos
Hipocalcemia/prevenção & controle , Imagem de Contraste de Manchas a Laser/métodos , Tratamentos com Preservação do Órgão/métodos , Glândulas Paratireoides/irrigação sanguínea , Glândulas Paratireoides/diagnóstico por imagem , Complicações Pós-Operatórias/prevenção & controle , Cirurgia Assistida por Computador/métodos , Tireoidectomia/métodos , Adulto , Feminino , Humanos , Hipocalcemia/etiologia , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Glândulas Paratireoides/cirurgia , Complicações Pós-Operatórias/etiologia , Prognóstico
9.
Am J Surg ; 222(5): 944-951, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34024629

RESUMO

BACKGROUND: Near infrared autofluorescence (NIRAF) detection has previously demonstrated significant potential for real-time parathyroid gland identification. However, the performance of a NIRAF detection device - PTeye® - remains to be evaluated relative to a surgeon's own ability to identify parathyroid glands. METHODS: Patients eligible for thyroidectomy and/or parathyroidectomy were enrolled under 6 endocrine surgeons at 3 high-volume institutions. Participating surgeons were categorized based on years of experience. All surgeons were blinded to output of PTeye® when identifying tissues. The surgeon's performance for parathyroid discrimination was then compared with PTeye®. Histology served as gold standard for excised specimens, while expert surgeon's opinion was used to validate in-situ tissues. RESULTS: PTeye® achieved 92.7% accuracy across 167 patients recruited. Junior surgeons (<5 years of experience) were found to have lower confidence in parathyroid identification and higher tissue misclassification rate per specimen when compared to PTeye® and senior surgeons (>10 years of experience). CONCLUSIONS: NIRAF detection with PTeye® can be a valuable intraoperative adjunct technology to aid in parathyroid identification for surgeons.


Assuntos
Período Intraoperatório , Imagem Óptica/métodos , Glândulas Paratireoides/anatomia & histologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Competência Clínica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Glândulas Paratireoides/diagnóstico por imagem , Glândulas Paratireoides/cirurgia , Espectroscopia de Luz Próxima ao Infravermelho , Adulto Jovem
10.
Clin Transl Gastroenterol ; 11(7): e00195, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32764208

RESUMO

INTRODUCTION: Elucidating esophageal biochemical composition in eosinophilic esophagitis (EoE) can offer novel insights into its pathogenesis, which remains unclear. Using Raman spectroscopy, we profiled and compared the biochemical composition of esophageal samples obtained from children with active (aEoE) and inactive EoE (iEoE) with non-EoE controls, examined the relationship between spectral markers and validated EoE activity indices. METHODS: In vitro Raman spectra from children with aEoE (n = 8; spectra = 51) and iEoE (n = 6; spectra = 48) and from non-EoE controls (n = 10; spectra = 75) were acquired. Mann-Whitney test was used to assess the differences in their Raman intensities (median [interquartile range]) and identify spectral markers. Spearman correlation was used to evaluate the relationship between spectral markers and endoscopic and histologic activity indices. RESULTS: Raman peaks attributable to glycogen content (936/1,449 cm) was lower in children with aEoE (0.20 [0.18-0.21]) compared with that in non-EoE controls (0.24 [0.23-0.29]). Raman intensity of proteins (1,660/1,209 cm) was higher in children with aEoE compared with that in non-EoE controls (3.20 [3.07-3.50] vs 2.91 [2.59-3.05]; P = 0.01), whereas that of lipids (1,301/1,260 cm) was higher in children with iEoE (1.56 [1.49-1.63]) compared with children with aEoE (1.40 [1.30-1.48]; P = 0.02). Raman peaks attributable to glycogen and lipid inversely correlated with eosinophilic inflammation and basal zone hyperplasia. Raman mapping substantiated our findings. DISCUSSION: This is the first study to identify spectral traits of the esophageal samples related to EoE activity and tissue pathology and to profile tissue-level biochemical composition associated with pediatric EoE. Future research to determine the role of these biochemical alterations in development and clinical course of EoE can advance our understanding of EoE pathobiology.


Assuntos
Esofagite Eosinofílica/diagnóstico , Eosinófilos/imunologia , Mucosa Esofágica/patologia , Esofagoscopia/métodos , Análise Espectral Raman , Adolescente , Biópsia , Criança , Esofagite Eosinofílica/imunologia , Esofagite Eosinofílica/patologia , Mucosa Esofágica/citologia , Mucosa Esofágica/diagnóstico por imagem , Mucosa Esofágica/imunologia , Feminino , Humanos , Masculino , Estudos Prospectivos
11.
FASEB J ; 34(5): 6539-6553, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32202681

RESUMO

Astrocytes are non-neuronal cells that govern the homeostatic regulation of the brain through ions and water transport, and Ca2+ -mediated signaling. As they are tightly integrated into neural networks, label-free tools that can modulate cell function are needed to evaluate the role of astrocytes in brain physiology and dysfunction. Using live-cell fluorescence imaging, pharmacology, electrophysiology, and genetic manipulation, we show that pulsed infrared light can modulate astrocyte function through changes in intracellular Ca2+ and water dynamics, providing unique mechanistic insight into the effect of pulsed infrared laser light on astroglial cells. Water transport is activated and, IP3 R, TRPA1, TRPV4, and Aquaporin-4 are all involved in shaping the dynamics of infrared pulse-evoked intracellular calcium signal. These results demonstrate that astrocyte function can be modulated with infrared light. We expect that targeted control over calcium dynamics and water transport will help to study the crucial role of astrocytes in edema, ischemia, glioma progression, stroke, and epilepsy.


Assuntos
Astrócitos/metabolismo , Cálcio/metabolismo , Raios Infravermelhos , Água/metabolismo , Animais , Aquaporina 4/genética , Aquaporina 4/metabolismo , Astrócitos/citologia , Astrócitos/efeitos da radiação , Transporte Biológico , Células Cultivadas , Homeostase , Ratos , Transdução de Sinais , Canal de Cátion TRPA1/genética , Canal de Cátion TRPA1/metabolismo , Canais de Cátion TRPV/genética , Canais de Cátion TRPV/metabolismo
12.
Chem Sci ; 11(36): 9863-9874, 2020 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-34094246

RESUMO

Rapid and accurate response to targeted therapies is critical to differentiate tumors that are resistant to treatment early in the regimen. In this work, we demonstrate a rapid, noninvasive, and label-free approach to evaluate treatment response to molecular inhibitors in breast cancer (BC) cells with Raman spectroscopy (RS). Metabolic reprogramming in BC was probed with RS and multivariate analysis was applied to classify the cells into responsive or nonresponsive groups as a function of drug dosage, drug type, and cell type. Metabolites identified with RS were then validated with mass spectrometry (MS). We treated triple-negative BC cells with Trametinib, an inhibitor of the extracellular-signal-regulated kinase (ERK) pathway. Changes measured with both RS and MS corresponding to membrane phospholipids, amino acids, lipids and fatty acids indicated that these BC cells were responsive to treatment. Comparatively, minimal metabolic changes were observed post-treatment with Alpelisib, an inhibitor of the mammalian target of rapamycin (mTOR) pathway, indicating treatment resistance. These findings were corroborated with cell viability assay and immunoblotting. We also showed estrogen receptor-positive MCF-7 cells were nonresponsive to Trametinib with minimal metabolic and viability changes. Our findings support that oncometabolites identified with RS will ultimately enable rapid drug screening in patients ensuring patients receive the most effective treatment at the earliest time point.

13.
Ann Surg ; 272(6): 973-985, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-31804401

RESUMO

OBJECTIVE: With the recent approval of 2 NIRAF-based devices for label-free identification of PG by the Food and Drug Administration, it becomes crucial to educate the surgical community on the realistic scope of this emerging technology. Here, we have compiled a review of studies that utilize NIRAF and present a critical appraisal of this technique for intraoperative PG detection. BACKGROUND: Failure to visualize PGs could lead to accidental damage/excision of healthy PGs or inability to localize diseased PGs, resulting in postsurgical complications. The discovery that PGs have NIRAF led to new avenues for intraoperatively identifying PGs with high accuracy in real-time. METHODS: Using the following key terms: "parathyroid, near infrared, autofluorescence" in various search engines such as PubMed and Google Scholar, we identified various publications relevant to this review of NIRAF as a technique for PG identification. Articles were excluded if they focused solely on contrast agents, served as commentaries/overviews on NIRAF or were not written in English. RESULTS: To date, studies have investigated the potential of NIRAF detection for (i) identifying PG tissues intraoperatively, (ii) locating PGs before or after dissection, (iii) distinguishing healthy from diseased PGs, and (iv) minimizing postoperative hypocalcemia after total thyroidectomy. CONCLUSIONS: Because NIRAF-based identification of PG is noninvasive and label-free, the popularity of this approach has considerably surged. As the present limitations of various technologies capable of NIRAF detection are identified, we anticipate that newer device iterations will continue to be developed enhancing the current merits of these modalities to aid surgeons in identifying and preserving PGs. However, more concrete and long-term outcome studies with these modalities are essential to determine the impact of this technique on patient outcome and actual cost-benefits.


Assuntos
Cuidados Intraoperatórios/métodos , Imagem Óptica , Glândulas Paratireoides/diagnóstico por imagem , Paratireoidectomia , Desenho de Equipamento , Humanos , Imagem Óptica/instrumentação , Imagem Óptica/métodos , Paratireoidectomia/métodos , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação
14.
ACS Nano ; 14(1): 651-663, 2020 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-31851488

RESUMO

The overexpression of immunomarker programmed cell death protein 1 (PD-1) and engagement of PD-1 to its ligand, PD-L1, are involved in the functional impairment of cluster of differentiation 8+ (CD8+) T cells, contributing to cancer progression. However, heterogeneities in PD-L1 expression and variabilities in biopsy-based assays render current approaches inaccurate in predicting PD-L1 status. Therefore, PD-L1 screening alone is not predictive of patient response to treatment, which motivates us to simultaneously detect multiple immunomarkers engaged in immune modulation. Here, we have developed multimodal probes, immunoactive gold nanostars (IGNs), that accurately detect PD-L1+ tumor cells and CD8+ T cells simultaneously in vivo, surpassing the limitations of current immunoimaging techniques. IGNs integrate the whole-body imaging of positron emission tomography with high sensitivity and multiplexing of Raman spectroscopy, enabling the dynamic tracking of both immunomarkers. IGNs also monitor response to immunotherapies in mice treated with combinatorial PD-L1 and CD137 agonists and distinguish responders from those nonresponsive to treatment. Our results showed a multifunctional nanoscale probe with capabilities that cannot be achieved with either modality alone, allowing multiplexed immunologic tumor profiling critical for predicting early response to immunotherapies.


Assuntos
Biomarcadores Tumorais/análise , Ouro/química , Imunoterapia , Melanoma/diagnóstico por imagem , Melanoma/terapia , Nanopartículas Metálicas/química , Imagem Óptica , Animais , Antígeno B7-H1/agonistas , Antígeno B7-H1/análise , Antígeno B7-H1/genética , Biomarcadores Tumorais/agonistas , Biomarcadores Tumorais/genética , Linhagem Celular Tumoral , Modelos Animais de Doenças , Camundongos , Tamanho da Partícula , Propriedades de Superfície , Membro 9 da Superfamília de Receptores de Fatores de Necrose Tumoral/agonistas , Membro 9 da Superfamília de Receptores de Fatores de Necrose Tumoral/análise , Membro 9 da Superfamília de Receptores de Fatores de Necrose Tumoral/genética
15.
J Am Coll Surg ; 229(6): 596-608.e3, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31562910

RESUMO

BACKGROUND: Near infrared autofluorescence (NIRAF) can guide intraoperative parathyroid gland (PG) identification. NIRAF detection devices typically rely on imaging and fiber probe-based approaches. Imaging modalities provide NIRAF pictures on adjacent display monitors, and fiber probe-based systems measure tissue NIRAF and provide real-time quantitative information to objectively aid PG identification. Both device types recently gained FDA approval for PG identification but have never been compared directly. STUDY DESIGN: Patients undergoing thyroidectomy and/or parathyroidectomy were recruited prospectively. Target tissues were intraoperatively visualized with PDE-Neo II (imaging-based) and concurrently assessed with PTeye (fiber probe-based). For PDE-Neo II, NIRAF images were collected from in situ or excised tissues, alongside the surgeon's interpretation of visualized tissues, and retrospectively analyzed in a blinded fashion. The PTeye was concomitantly used to record NIRAF intensities and ratios from the same tissues in real time. RESULTS: Twenty patients were enrolled for concurrent evaluation with both systems, which included 33 PGs and 19 nonparathyroid sites. NIRAF imaging demonstrated 90.9% sensitivity, 73.7% specificity, and 84.6% accuracy for PG identification when interpreted in real time by the surgeon compared with 81.8% sensitivity, 73.7% specificity, and 78.8% accuracy where images were quantitatively analyzed post hoc by an independent observer. In parallel, NIRAF detection with PTeye yielded 97.0% sensitivity, 84.2% specificity, and 92.3% accuracy in real time for the same specimens. CONCLUSIONS: Both NIRAF-based systems were beneficial for identifying PGs intraoperatively. Although NIRAF imaging provides valuable spatial information to localize PGs, NIRAF detection with fiber probe provides real-time quantitative information to identify PGs in presence of ambient room lights.


Assuntos
Imagem Óptica/métodos , Glândulas Paratireoides/diagnóstico por imagem , Paratireoidectomia/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Cirurgia Assistida por Computador/métodos , Tireoidectomia/métodos , Adulto , Feminino , Seguimentos , Humanos , Masculino , Microcirurgia/métodos , Pessoa de Meia-Idade , Glândulas Paratireoides/cirurgia , Complicações Pós-Operatórias/prevenção & controle , Estudos Retrospectivos
16.
J Gastroenterol Hepatol ; 34(11): 1911-1921, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31124184

RESUMO

Esophageal diseases result in significant mortality, morbidity, and health care costs worldwide. Current approaches to detect and monitor esophageal diseases have severe limitations. Advanced imaging technologies are being developed to complement current approaches to improve diagnostic, therapeutic and surveillance protocols in order to advance the field. Raman spectroscopy-based technologies hold promise to increase the sensitivity for detection of diseased and high-risk lesions in vitro and in vivo in real time. This technique allows for the investigation of microstructural changes and also facilitates the discovery of disease-specific biochemical alterations with the potential to provide novel insights into the pathobiology of these conditions. Raman spectroscopy has been increasingly applied in precancerous and cancerous esophageal conditions. However, its application in benign esophageal diseases is still in the early stages. Continuing its application in cancerous and precancerous conditions and expanding its use to benign esophageal disorders could lay a foundation for integration of this technology in clinical practice and diagnostic paradigms and development of an accurate and cost-effective tool for use in a clinical setting. Furthermore, Raman spectroscopy can also be used as an innovative technique to advance our understanding of the biochemical transformations associated with esophageal diseases and answer a myriad of fundamental questions in the field. In this review, we described the principles of Raman spectroscopy and instrumentation while providing an overview of current applications, challenges, and future directions in the context of esophageal diseases with an emphasis on its clinical translational application.


Assuntos
Doenças do Esôfago/diagnóstico , Análise Espectral Raman/métodos , Humanos , Análise Espectral Raman/instrumentação
17.
J Am Coll Surg ; 228(5): 730-743, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30769112

RESUMO

BACKGROUND: Misidentifying parathyroid glands (PGs) during thyroidectomies or parathyroidectomies could significantly increase postoperative morbidity. Imaging systems based on near infrared autofluorescence (NIRAF) detection can localize PGs with high accuracy. These devices, however, depict NIRAF images on remote display monitors, where images lack spatial context and comparability with actual surgical field of view. In this study, we designed an overlay tissue imaging system (OTIS) that detects tissue NIRAF and back-projects the collected signal as a visible image directly onto the surgical field of view instead of a display monitor, and tested its ability for enhancing parathyroid visualization. STUDY DESIGN: The OTIS was first calibrated with a fluorescent ink grid and initially tested with parathyroid, thyroid, and lymph node tissues ex vivo. For in vivo measurements, the surgeon's opinion on tissue of interest was first ascertained. After the surgeon looked away, the OTIS back-projected visible green light directly onto the tissue of interest, only if the device detected relatively high NIRAF as observed in PGs. System accuracy was determined by correlating NIRAF projection with surgeon's visual confirmation for in situ PGs or histopathology report for excised PGs. RESULTS: The OTIS yielded 100% accuracy when tested ex vivo with parathyroid, thyroid, and lymph node specimens. Subsequently, the device was evaluated in 30 patients who underwent thyroidectomy and/or parathyroidectomy. Ninety-seven percent of exposed tissue of interest was visualized correctly as PGs by the OTIS, without requiring display monitors or contrast agents. CONCLUSIONS: Although OTIS holds novel potential for enhancing label-free parathyroid visualization directly within the surgical field of view, additional device optimization is required for eventual clinical use.


Assuntos
Aumento da Imagem/métodos , Imagem Óptica/métodos , Glândulas Paratireoides/diagnóstico por imagem , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Adulto , Idoso , Desenho de Equipamento , Feminino , Fluorescência , Humanos , Aumento da Imagem/instrumentação , Masculino , Pessoa de Meia-Idade , Imagem Óptica/instrumentação , Doenças das Paratireoides/diagnóstico por imagem , Doenças das Paratireoides/cirurgia , Glândulas Paratireoides/cirurgia , Paratireoidectomia , Imagens de Fantasmas , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Cirurgia Assistida por Computador , Doenças da Glândula Tireoide/diagnóstico por imagem , Doenças da Glândula Tireoide/cirurgia , Tireoidectomia
18.
Surgery ; 165(1): 114-123, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30442424

RESUMO

BACKGROUND: Difficulty in identifying the parathyroid gland during neck operations can lead to accidental parathyroid gland excisions and postsurgical hypocalcemia. A clinical prototype called as PTeye was developed to guide parathyroid gland identification using a fiber-optic probe that detects near-infrared autofluorescence from parathyroid glands as operating room lights remain on. An Overlay Tissue Imaging System was designed concurrently to detect near-infrared autofluorescence and project visible light precisely onto parathyroid gland location. METHODS: The PTeye and the Overlay Tissue Imaging System were tested in 20 and 15 patients, respectively, and a modified near-infrared imaging system was investigated in 6 patients. All 41 patients underwent thyroidectomy or parathyroidectomy. System accuracy was ascertained with surgeon's visual confirmation for in situ parathyroid glands and histology for excised parathyroid glands. RESULTS: There was no observable difference between near-infrared autofluorescence of healthy and diseased parathyroid glands. The PTeye identified 98% of the parathyroid gland, whereas the near-infrared imaging system and the Overlay Tissue Imaging System identified 100% and 97% of the parathyroid glands, respectively. CONCLUSION: The PTeye can guide in real-time parathyroid gland identification even with ambient operating room lights. The near-infrared imaging system performs parathyroid gland imaging with high sensitivity, whereas the Overlay Tissue Imaging System enhances parathyroid gland visualization directly within the surgical field without requiring display monitors. These label-free technologies can be valuable adjuncts for identifying parathyroid glands intraoperatively.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Complicações Intraoperatórias/prevenção & controle , Imagem Óptica/instrumentação , Glândulas Paratireoides/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Paratireoidectomia , Tireoidectomia , Adulto Jovem
19.
Nanoscale ; 10(27): 13092-13105, 2018 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-29961778

RESUMO

In this work, we demonstrate the targeted diagnosis of immunomarker programmed death ligand 1 (PD-L1) and simultaneous detection of epidermal growth factor receptor (EGFR) in breast cancer tumors in vivo using gold nanostars (AuNS) with multiplexed surface enhanced Raman spectroscopy (SERS). Real-time longitudinal tracking with SERS demonstrated maximum accumulation of AuNS occurred 6 h post intravenous (IV) delivery, enabling detection of both biomarkers simultaneously. Raman signal correlating to both PD-L1 and EGFR decreased by ∼30% in control tumors where receptors were pre-blocked prior to AuNS delivery, indicating both the sensitivity and specificity of SERS in distinguishing tumors with different levels of PD-L1 and EGFR expression. Our in vivo study was combined with the first demonstration of ex vivo SERS spatial maps of whole tumor lesions that provided both a qualitative and quantitative assessment of biomarker status with near cellular-level resolution. High resolution SERS maps also provided an overview of AuNS distribution in tumors which correlated well with the vascular density. Mass spectrometry showed AuNS accumulation in tumor and liver, and clearance via spleen, and electron microscopy revealed AuNS were endocytosed in tumors, Kupffer cells in the liver, and macrophages in the spleen. This study demonstrates that SERS-based diagnosis mediated by AuNS provides an accurate measure of multiple biomarkers both in vivo and ex vivo, which will ultimately enable a clinically-translatable platform for patient-tailored immunotherapies and combination treatments.


Assuntos
Neoplasias da Mama/diagnóstico , Ouro , Nanopartículas Metálicas , Análise Espectral Raman , Antígeno B7-H1/análise , Receptores ErbB/análise , Humanos , Sensibilidade e Especificidade
20.
J Med Imaging (Bellingham) ; 5(2): 021220, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29531968

RESUMO

Fluorescence imaging is a well-established optical modality that has been used to localize and track fluorophores in vivo and has demonstrated great potential for surgical guidance. Despite the variety of fluorophores currently being researched, many existing intraoperative fluorescence imaging systems are specifically designed for a limited number of applications. We present a modular wide-field fluorescence overlay tissue imaging system for intraoperative surgical guidance that is comprised of commercially available standardized components. Its modular layout allows for the accommodation of a broad range of fluorophores, fields of view (FOV), and spatial resolutions while maintaining an integrated portable design for intraoperative use. Measurements are automatic and feature a real-time projection overlay technique that intuitively displays fluorescence maps directly onto a [Formula: see text] FOV from a working distance of 35 cm. At a 20-ms exposure time, [Formula: see text] samples of indocyanine green could be measured with high signal-to-noise ratio and was later tested in an in vivo mouse model before finally being demonstrated for intraoperative autofluorescence imaging of human soft tissue sarcoma margins. The system's modular design and ability to enable naked-eye visualization of wide-field fluorescence allow for the flexibility to adapt to numerous clinical applications and can potentially extend the adoption of fluorescence imaging for intraoperative use.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA