1.
Health Technol Assess ; 27(10): 1-115, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37839810

RESUMO

Background: Magnetic resonance imaging-based technologies are non-invasive diagnostic tests that can be used to assess non-alcoholic fatty liver disease. Objectives: The study objectives were to assess the diagnostic test accuracy, clinical impact and cost-effectiveness of two magnetic resonance imaging-based technologies (LiverMultiScan and magnetic resonance elastography) for patients with non-alcoholic fatty liver disease for whom advanced fibrosis or cirrhosis had not been diagnosed and who had indeterminate results from fibrosis testing, or for whom transient elastography or acoustic radiation force impulse was unsuitable, or who had discordant results from fibrosis testing. Data sources: The data sources searched were MEDLINE, MEDLINE Epub Ahead of Print, In-Process & Other Non-Indexed Citations, Embase, Cochrane Database of Systematic Reviews, Cochrane Central Database of Controlled Trials, Database of Abstracts of Reviews of Effects and the Health Technology Assessment. Methods: A systematic review was conducted using established methods. Diagnostic test accuracy estimates were calculated using bivariate models and a summary receiver operating characteristic curve was calculated using a hierarchical model. A simple decision-tree model was developed to generate cost-effectiveness results. Results: The diagnostic test accuracy review (13 studies) and the clinical impact review (11 studies) only included one study that provided evidence for patients who had indeterminate or discordant results from fibrosis testing. No studies of patients for whom transient elastography or acoustic radiation force impulse were unsuitable were identified. Depending on fibrosis level, relevant published LiverMultiScan diagnostic test accuracy results ranged from 50% to 88% (sensitivity) and from 42% to 75% (specificity). No magnetic resonance elastography diagnostic test accuracy data were available for the specific population of interest. Results from the clinical impact review suggested that acceptability of LiverMultiScan was generally positive. To explore how the decision to proceed to biopsy is influenced by magnetic resonance imaging-based technologies, the External Assessment Group presented cost-effectiveness analyses for LiverMultiScan plus biopsy versus biopsy only. Base-case incremental cost-effectiveness ratio per quality-adjusted life year gained results for seven of the eight diagnostic test strategies considered showed that LiverMultiScan plus biopsy was dominated by biopsy only; for the remaining strategy (Brunt grade ≥2), the incremental cost-effectiveness ratio per quality-adjusted life year gained was £1,266,511. Results from threshold and scenario analyses demonstrated that External Assessment Group base-case results were robust to plausible variations in the magnitude of key parameters. Limitations: Diagnostic test accuracy, clinical impact and cost-effectiveness data for magnetic resonance imaging-based technologies for the population that is the focus of this assessment were limited. Conclusions: Magnetic resonance imaging-based technologies may be useful to identify patients who may benefit from additional testing in the form of liver biopsy and those for whom this additional testing may not be necessary. However, there is a paucity of diagnostic test accuracy and clinical impact data for patients who have indeterminate results from fibrosis testing, for whom transient elastography or acoustic radiation force impulse are unsuitable or who had discordant results from fibrosis testing. Given the External Assessment Group cost-effectiveness analyses assumptions, the use of LiverMultiScan and magnetic resonance elastography for assessing non-alcoholic fatty liver disease for patients with inconclusive results from previous fibrosis testing is unlikely to be a cost-effective use of National Health Service resources compared with liver biopsy only. Study registration: This study is registered as PROSPERO CRD42021286891. Funding: Funding for this study was provided by the Evidence Synthesis Programme of the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 27, No. 10. See the NIHR Journals Library website for further project information.


Non-alcoholic fatty liver disease includes a range of conditions that are caused by a build-up of fat in the liver, and not by alcohol consumption. This build-up of fat can cause inflammation. Persistent inflammation can cause scar tissue (fibrosis) to develop. It is important to identify patients with fibrosis because severe fibrosis can cause permanent liver damage (cirrhosis), which can lead to liver failure and liver cancer. In the National Health Service, patients with non-alcoholic fatty liver disease undergo tests to determine whether they have fibrosis. The test results are not always accurate and multiple tests can give conflicting results. Some of the tests may not be suitable for patients who have a very high body mass index. In the National Health Service, a liver biopsy may be offered to patients with inconclusive or conflicting test results or to those patients for whom other tests are unsuitable. However, liver biopsy is expensive, and is associated with side-effects such as pain and bleeding. Magnetic resonance imaging-based testing could be used as an extra test to help clinicians assess non-alcoholic fatty liver disease and identify patients who may need a liver biopsy. We assessed two magnetic resonance imaging-based diagnostic tests, LiverMultiScan and magnetic resonance elastography. LiverMultiScan is imaging software that is used alongside magnetic resonance imaging to measure markers of liver disease. Magnetic resonance elastography is used in some National Health Service centres to assess liver fibrosis; however, magnetic resonance elastography requires more equipment than just an magnetic resonance imaging scanner. We reviewed all studies examining how well LiverMultiScan and magnetic resonance elastography assess patients with non-alcoholic fatty liver disease. We also built an economic model to estimate the costs and benefits of using LiverMultiScan to identify patients who should be sent for a biopsy. Results from the model showed that LiverMultiScan may not provide good value for money to the National Health Service.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Humanos , Análise Custo-Benefício , Cirrose Hepática/diagnóstico , Cirrose Hepática/patologia , Imageamento por Ressonância Magnética , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Medicina Estatal
2.
Pharmacoecon Open ; 7(3): 345-358, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37084172

RESUMO

The National Institute for Health and Care Excellence (NICE) provides guidance to improve health and social care in England and Wales. NICE invited Daiichi Sankyo to submit evidence for the use of trastuzumab deruxtecan (T-DXd) for treating human epidermal growth factor 2 (HER2)-positive unresectable or metastatic breast cancer (UBC/MBC) after two or more anti-HER2 therapies, in accordance with NICE's Single Technology Appraisal process. The Liverpool Reviews and Implementation Group, part of the University of Liverpool, was commissioned to act as the Evidence Review Group (ERG). This article summarises the ERG's review of the evidence submitted by the company and provides an overview of the NICE Appraisal Committee's (AC's) final decision made in May 2021. Results from the company's base-case fully incremental analysis showed that, compared with T-DXd, eribulin and vinorelbine were dominated and the incremental cost-effectiveness ratio (ICER) per quality-adjusted life year (QALY) gained versus capecitabine was £47,230. The ERG scenario analyses generated a range of ICERs, with the highest being a scenario relating to a comparison of T-DXd versus capecitabine (£78,142 per QALY gained). The ERG considered that due to a lack of appropriate clinical effectiveness evidence, the relative effectiveness of T-DXd versus any comparator treatment could not be determined with any degree of certainty. The NICE AC agreed that the modelling of overall survival was highly uncertain and concluded that treatment with T-DXd could not be recommended for routine use within the National Health Service (NHS). T-DXd was, however, recommended for use within the Cancer Drugs Fund, provided Managed Access Agreement conditions were followed.

3.
BMC Pulm Med ; 22(1): 375, 2022 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-36199061

RESUMO

BACKGROUND: The World Health Organisation (WHO) recommends that testing and treatment for latent tuberculosis infection (LTBI) should be undertaken in high-risk groups using either interferon gamma release assays (IGRAs) or a tuberculin skin test (TST). As IGRAs are more expensive than TST, an assessment of the cost-effectiveness of IGRAs can guide decision makers on the most appropriate choice of test for different high-risk populations. This current review aimed to provide the most up to date evidence on the cost-effectiveness evidence on LTBI testing in high-risk groups-specifically evidence reporting the costs per QALY of different testing strategies. METHODS: A comprehensive search of databases including MEDLINE, EMBASE and NHS-EED was undertaken from 2011 up to March 2021. Studies were screened and extracted by two independent reviewers. The study quality was assessed using the Bias in Economic Evaluation Checklist (ECOBIAS). A narrative synthesis of the included studies was undertaken. RESULTS: Thirty-two studies reported in thirty-three documents were included in this review. Quality of included studies was generally high, although there was a weakness across all studies referencing sources correctly and/or justifying choices of parameter values chosen or assumptions where parameter values were not available. Inclusions of IGRAs in testing strategies was consistently found across studies to be cost-effective but this result was sensitive to underlying LTBI prevalence rates. CONCLUSION: While some concerns remain about uncertainty in parameter values used across included studies, the evidence base since 2010 has grown with modelling approaches addressing the weakness pointed out in previous reviews but still reaching the same conclusion that IGRAs are likely to be cost-effective in high-income countries for high-risk populations. Evidence is also required on the cost-effectiveness of different strategies in low to middle income countries and countries with high TB burden.


Assuntos
Tuberculose Latente , Análise Custo-Benefício , Humanos , Testes de Liberação de Interferon-gama/métodos , Tuberculose Latente/diagnóstico , Programas de Rastreamento/métodos , Prevalência , Teste Tuberculínico/métodos
4.
Cell Stress Chaperones ; 26(5): 845-857, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34542825

RESUMO

Developing immunosuppressive therapies for autoimmune diseases comes with a caveat that immunosuppression may promote the risk of developing other conditions or diseases. We have previously shown that biolistic delivery of an expression construct encoding inducible HSP70 (HSP70i) with one amino acid modification in the dendritic cell (DC) activating moiety 435-445 (HSP70iQ435A) to mouse skin resulted in significant immunosuppressive activity of autoimmune vitiligo, associated with fewer tissue infiltrating T cells. To prepare HSP70iQ435A as a potential therapeutic for autoimmune vitiligo, in this study we evaluated whether and how biolistic delivery of HSP70iQ435A in mice affects anti-tumor responses. We found that HSP70iQ435A in fact supports anti-tumor responses in melanoma-challenged C57BL/6 mice. Biolistic delivery of the HSP70iQ435A-encoding construct to mice elicited significant anti-HSP70 titers, and anti-HSP70 IgG and IgM antibodies recognize surface-expressed and cytoplasmic HSP70i in human and mouse melanoma cells. A peptide scan revealed that the anti-HSP70 antibodies recognize a specific C-terminal motif within the HSP70i protein. The antibodies elicited surface CD107A expression among mouse NK cells, representative of antibody-mediated cellular cytotoxicity (ADCC), supporting the concept, that HSP70iQ435A-encoding DNA elicits a humoral response to the stress protein expressed selectively on the surface of melanoma cells. Thus, besides limiting autoimmunity and inflammation, HSP70iQ435A elicits humoral responses that limit tumor growth and may be used in conjunction with immune checkpoint inhibitors to not only control tumor but to also limit adverse events following tumor immunotherapy.


Assuntos
Autoimunidade , Proteínas de Choque Térmico HSP70/genética , Melanoma/genética , Melanoma/imunologia , Mutação/genética , Neoplasias Cutâneas/genética , Neoplasias Cutâneas/imunologia , Animais , Anticorpos/metabolismo , Autoimunidade/genética , Degranulação Celular , Linhagem Celular Tumoral , DNA de Neoplasias/metabolismo , Proteínas de Choque Térmico HSP70/metabolismo , Humanos , Células Matadoras Naturais/metabolismo , Células Matadoras Naturais/fisiologia , Masculino , Melanoma/patologia , Camundongos Endogâmicos C57BL , Modelos Biológicos , Neoplasias Cutâneas/patologia
5.
Pharmacoecon Open ; 5(1): 13-22, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32291725

RESUMO

As part of the Single Technology Appraisal process, the National Institute for Health and Care Excellence (NICE) invited Pierre Fabre to submit evidence for the clinical and cost-effectiveness of encorafenib with binimetinib (Enco + Bini) versus dabrafenib with trametinib (Dab + Tram) as a first-line treatment for advanced (unresectable or metastatic) BRAF V600 mutation-positive melanoma. The Liverpool Reviews and Implementation Group at the University of Liverpool was commissioned as the Evidence Review Group (ERG). This article summarises the ERG's review of the company's evidence submission (CS), and the Appraisal Committee's (AC's) final decision. The main clinical evidence in the CS was derived from the COLUMBUS trial and focused on the efficacy of Enco + Bini (encorafenib 450 mg per day plus binimetinib 45 mg twice daily) compared to vemurafenib. The company conducted network meta-analyses (NMAs) to indirectly estimate the relative effects of progression-free survival (PFS), overall survival (OS), adverse events (AEs) and health-related quality of life (HRQoL) for Enco + Bini versus Dab + Tram. None of the results from the NMAs demonstrated a statistically significant difference between the treatment regimens for any outcomes. The ERG advised caution when interpreting the results from the company's NMAs due to limitations relating to the methods. The ERG considered that use of the OS and PFS hazard ratios (HRs) generated by the company's NMAs to model the relative effectiveness of Enco + Bini versus Dab + Tram in the company model was inappropriate as these estimates were not statistically significantly different. The ERG amended the company's economic model to include estimates of equivalent efficacy, safety and HRQoL for Enco + Bini and Dab + Tram. The ERG considered use of different estimates of relative dose intensity to be inappropriate and used the same estimate for both drug combinations. The ERG also concluded that as only the prices of drug combinations were different, a cost comparison was an appropriate method of economic analysis. Using this approach (combined with confidential discounted drug prices for Enco + Bini and Dab + Tram), treatment with Enco + Bini was more cost effective than treatment with Dab + Tram. The AC raised concerns that an absence of evidence of a difference in outcomes between Enco + Bini and Dab + Tram did not constitute evidence of absence. However, as the numerical differences in outcomes generated by the company's networks were small, the AC did not have a preferred approach and considered that both the company's and the ERG's methods of incorporating outcome estimates into the economic model were suitable for decision making. The NICE AC recommended Enco + Bini as a first-line treatment for unresectable or metastatic melanoma with a BRAF V600 mutation.

6.
Health Technol Assess ; 24(3): 1-164, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31933471

RESUMO

BACKGROUND: Atrial fibrillation (AF) is the most common type of cardiac arrhythmia and is associated with an increased risk of stroke and congestive heart failure. Lead-I electrocardiogram (ECG) devices are handheld instruments that can be used to detect AF at a single time point in people who present with relevant signs or symptoms. OBJECTIVE: To assess the diagnostic test accuracy, clinical impact and cost-effectiveness of using single time point lead-I ECG devices for the detection of AF in people presenting to primary care with relevant signs or symptoms, and who have an irregular pulse compared with using manual pulse palpation (MPP) followed by a 12-lead ECG in primary or secondary care. DATA SOURCES: MEDLINE, MEDLINE Epub Ahead of Print and MEDLINE In-Process & Other Non-Indexed Citations, EMBASE, PubMed, Cochrane Databases of Systematic Reviews, Cochrane Central Database of Controlled Trials, Database of Abstracts of Reviews of Effects and the Health Technology Assessment Database. METHODS: The systematic review methods followed published guidance. Two reviewers screened the search results (database inception to April 2018), extracted data and assessed the quality of the included studies. Summary estimates of diagnostic accuracy were calculated using bivariate models. An economic model consisting of a decision tree and two cohort Markov models was developed to evaluate the cost-effectiveness of lead-I ECG devices. RESULTS: No studies were identified that evaluated the use of lead-I ECG devices for patients with signs or symptoms of AF. Therefore, the diagnostic accuracy and clinical impact results presented are derived from an asymptomatic population (used as a proxy for people with signs or symptoms of AF). The summary sensitivity of lead-I ECG devices was 93.9% [95% confidence interval (CI) 86.2% to 97.4%] and summary specificity was 96.5% (95% CI 90.4% to 98.8%). One study reported limited clinical outcome data. Acceptability of lead-I ECG devices was reported in four studies, with generally positive views. The de novo economic model yielded incremental cost-effectiveness ratios (ICERs) per quality-adjusted life-year (QALY) gained. The results of the pairwise analysis show that all lead-I ECG devices generated ICERs per QALY gained below the £20,000-30,000 threshold. Kardia Mobile (AliveCor Ltd, Mountain View, CA, USA) is the most cost-effective option in a full incremental analysis. LIMITATIONS: No published data evaluating the diagnostic accuracy, clinical impact or cost-effectiveness of lead-I ECG devices for the population of interest are available. CONCLUSIONS: Single time point lead-I ECG devices for the detection of AF in people with signs or symptoms of AF and an irregular pulse appear to be a cost-effective use of NHS resources compared with MPP followed by a 12-lead ECG in primary or secondary care, given the assumptions used in the base-case model. FUTURE WORK: Studies assessing how the use of lead-I ECG devices in this population affects the number of people diagnosed with AF when compared with current practice would be useful. STUDY REGISTRATION: This study is registered as PROSPERO CRD42018090375. FUNDING: The National Institute for Health Research Health Technology Assessment programme.


Atrial fibrillation (AF) is the most common type of abnormal heart rhythm. People with AF are more likely to have a serious stroke or die than people without the condition. Many people go to their general practitioner (GP) with the signs or symptoms commonly linked to AF, such as feeling dizzy, being short of breath, feeling tired and having heart palpitations. GPs check for AF by taking the patient's pulse by hand. If the GP thinks that the patient might have AF, a 12-lead electrocardiogram (ECG) test is arranged. Lead-I (i.e. one lead) ECGs are handheld electronic devices that could detect AF more accurately than a manual pulse check. If GPs were to routinely use lead-I ECG devices, people with suspected AF could receive treatment while waiting for the AF diagnosis to be confirmed by a 12-lead ECG. This study aimed to assess whether or not the use of lead-I ECGs in GP surgeries could benefit these patients and offer good value for money to the NHS. All studies that examined how well lead-I ECGs identified people with AF were reviewed, and the economic value of using these devices was assessed. No evidence was found that examined the use of lead-I ECGs for people with signs or symptoms of AF. As an alternative, evidence for the use of lead-I ECGs for people with no symptoms of AF was searched for and these data were used to assess value for money. The study found that using a manual pulse check followed by a lead-I ECG offers value for money when compared with a manual pulse check followed by a 12-lead ECG. This is mostly because patients with AF can begin treatment earlier when a GP has access to a lead-I ECG device.


Assuntos
Fibrilação Atrial/diagnóstico , Análise Custo-Benefício , Eletrocardiografia , Programas de Rastreamento , Valor Preditivo dos Testes , Avaliação da Tecnologia Biomédica , Insuficiência Cardíaca/prevenção & controle , Humanos , Programas de Rastreamento/economia , Programas de Rastreamento/estatística & dados numéricos , Modelos Econômicos , Atenção Primária à Saúde , Pulso Arterial , Anos de Vida Ajustados por Qualidade de Vida , Acidente Vascular Cerebral/prevenção & controle
7.
J Invest Dermatol ; 138(12): 2531-2539, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30031029

RESUMO

Human HSP70iQ435A carries a single amino-acid modification within the dendritic cell activating region and tolerizes dendritic cells in vitro. The underlying DNA was used to prevent and treat disease in vitiligo mouse models through reduced dendritic cell activation and diminished skin T-cell infiltration, suggesting the same may be useful for patients. Physiologic differences between mouse and human skin then called for studies in large animals with human-like skin. We established the efficiency of DNA jet injection into swine skin before subcloning HSP70iQ435A into clinically suitable vector pUMVC3. Vitiligo lesions in Sinclair swine were treated with plasmid DNA to measure changes in depigmentation, T-cell infiltration, expression of HSP70i in skin, serum HSP70i, and anti-HSP70i serum titers. Remarkable repigmentation following HSP70iQ435A-encoding DNA treatment persisted throughout the 6-month follow-up period. Repigmentation was accompanied by an initial influx of T cells accompanied by increased CD4/CD8 ratios, waning by week 15. Melanocytes spanned the border of repigmenting skin, suggesting that melanocyte repopulation precedes skin melanization. Serum titer fluctuations were not treatment-associated. Importantly, treatment did not interfere with melanoma immunosurveillance. These data encourage clinical testing of HSP70iQ435A.


Assuntos
Células Dendríticas/imunologia , Proteínas de Choque Térmico HSP70/metabolismo , Imunoterapia/métodos , Melanoma/imunologia , Pigmentação da Pele/genética , Pele/patologia , Linfócitos T/imunologia , Vitiligo/imunologia , Animais , Diferenciação Celular , Movimento Celular , Células Cultivadas , DNA/genética , Modelos Animais de Doenças , Terapia Genética , Proteínas de Choque Térmico HSP70/genética , Humanos , Tolerância Imunológica , Vigilância Imunológica , Injeções a Jato , Ativação Linfocitária , Melanoma/genética , Melanoma/terapia , Mutação/genética , Neoplasias Experimentais , Pele/metabolismo , Suínos , Vitiligo/genética , Vitiligo/terapia
8.
Respir Med ; 129: 98-116, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28732842

RESUMO

BACKGROUND: Asthma and chronic obstructive pulmonary disease (COPD) are widespread chronic conditions with medication frequently delivered by inhalers. These can be challenging to use correctly, but the scale of misuse and the specific aspects of failure are unclear. METHODS: We used systematic review methods to search 9 databases in May 2015 to identify and review studies that assessed adults (18 years or older) with asthma or COPD using inhalers of various types including pressurised metered dose inhalers (pMDIs), dry powder inhalers and the Respimat inhaler. Studies must have reported the scale of inhaler misuse, variation by type of inhaler or which steps patients had difficulty completing accurately. RESULTS: The types of inhalers, inhaler interventions and definitions of failure and misuse varied widely in the 38 studies identified. It was not possible to draw conclusions on the differential failure rates between different types of inhalers or any patient characteristics. Of the studies reporting failure or misuse rates, the majority ranged between 0 and 20%. Studies were inconsistent regarding the number of inhaler steps collected, reported and labelled as critical. CONCLUSIONS: There is evidence for all identified inhalers that some people may be using them incorrectly, but it is unclear which inhalers have higher rates of misuse or which steps within the inhaler technique are most difficult for patients. The optimal techniques for using inhalers are not standardised. Researchers undertaking future inhaler studies are respectfully directed to our recommendations for future research.


Assuntos
Asma/tratamento farmacológico , Falha de Equipamento , Nebulizadores e Vaporizadores/estatística & dados numéricos , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Falha de Tratamento , Administração por Inalação , Adulto , Idoso , Broncodilatadores/administração & dosagem , Doença Crônica , Sistemas de Liberação de Medicamentos , Inaladores de Pó Seco , Desenho de Equipamento , Feminino , Humanos , Masculino , Inaladores Dosimetrados , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Testes de Função Respiratória/métodos , Fumar/efeitos adversos , Fumar/epidemiologia
9.
Health Econ Rev ; 6(1): 54, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27909996

RESUMO

OBJECTIVES: To estimate the cost savings and health benefits in the UK NHS that could be achieved if human milk usage in the NICU was increased. METHODS: A systematic review established the disease areas with the strong sources of evidence of the short, medium and long-term benefits of human milk for preterm infants as opposed to the use of formula milk. The analysis assessed the economic impact of reducing rates of necrotising enterocolitis, sepsis, sudden infant death syndrome, leukaemia, otitis media, obesity and neurodevelopmental impairment. RESULTS: Based on the number of preterm babies born in 2013, if 100% of premature infants being fed mother's milk could be achieved in the NICU, the total lifetime cost savings to the NHS due to improved health outcomes is estimated to be £46.7 million (£30.1 million in the first year) with a total lifetime QALY gain of 10,594, There would be 238 fewer deaths due to neonatal infections and SIDS, resulting in a reduction of approximately £153.4 million in lifetime productivity. Sensitivity analyses indicated that results were robust to a wide range of inputs. CONCLUSIONS: This analysis established that increasing the use of human milk in NICUs in the UK would lead to cost savings to the NHS. More research is needed on the medium and long term health and economic outcomes associated with breastfeeding preterm infants, and the differences between mother's own and donor breast milk.

10.
Health Technol Assess ; 20(30): 1-68, 2016 04.
Artigo em Inglês | MEDLINE | ID: mdl-27109425

RESUMO

BACKGROUND: Respiratory problems are one of the most common causes of morbidity in preterm infants and may be treated with several modalities for respiratory support such as nasal continuous positive airway pressure (NCPAP) or nasal intermittent positive-pressure ventilation. The heated humidified high-flow nasal cannula (HHHFNC) is gaining popularity in clinical practice. OBJECTIVES: To address the clinical effectiveness of HHHFNC compared with usual care for preterm infants we systematically reviewed the evidence of HHHFNC with usual care following ventilation (the primary analysis) and with no prior ventilation (the secondary analysis). The primary outcome was treatment failure defined as the need for reintubation (primary analysis) or intubation (secondary analysis). We also aimed to assess the cost-effectiveness of HHHFNC compared with usual care if evidence permitted. DATA SOURCES: The following databases were searched: MEDLINE (2000 to 12 January 2015), EMBASE (2000 to 12 January 2015), The Cochrane Library (issue 1, 2015), ISI Web of Science (2000 to 12 January 2015), PubMed (1 March 2014 to 12 January 2015) and seven trial and research registers. Bibliographies of retrieved citations were also examined. REVIEW METHODS: Two reviewers independently screened all titles and abstracts to identify potentially relevant studies for inclusion in the review. Full-text copies were assessed independently. Data were extracted and assessed for risk of bias. Summary statistics were extracted for each outcome and, when possible, data were pooled. A meta-analysis was only conducted for the primary analysis, using fixed-effects models. An economic evaluation was planned. RESULTS: Clinical evidence was derived from seven randomised controlled trials (RCTs): four RCTs for the primary analysis and three RCTs for the secondary analysis. Meta-analysis found that only for nasal trauma leading to a change of treatment was there a statistically significant difference, favouring HHHFNC over NCPAP [risk ratio (RR) 0.21, 95% confidence interval (CI) 0.10 to 0.42]. For the following outcomes, there were no statistically significant differences between arms: treatment failure (reintubation < 7 days; RR 0.76, 95% CI 0.54 to 1.09), bronchopulmonary dysplasia (RR 0.92, 95% CI 0.72 to 1.17), death (RR 0.56, 95% CI 0.22 to 1.44), pneumothorax (RR 0.33, 95% CI 0.03 to 3.12), intraventricular haemorrhage (grade ≥ 3; RR 0.41, 95% CI 0.15 to 1.15), necrotising enterocolitis (RR 0.41, 95% CI 0.15 to 1.14), apnoea (RR 1.08, 95% CI 0.74 to 1.57) and acidosis (RR 1.16, 95% CI 0.38 to 3.58). With no evidence to support the superiority of HHHFNC over NCPAP, a cost-minimisation analysis was undertaken, the results suggesting HHHFNC to be less costly than NCPAP. However, this finding is sensitive to the lifespan of equipment and the cost differential of consumables. LIMITATIONS: There is a lack of published RCTs of relatively large-sized populations comparing HHHFNC with usual care; this is particularly true for preterm infants who had received no prior ventilation. CONCLUSIONS: There is a lack of convincing evidence suggesting that HHHFNC is superior or inferior to usual care, in particular NCPAP. There is also uncertainty regarding whether or not HHHFNC can be considered cost-effective. Further evidence comparing HHHFNC with usual care is required. STUDY REGISTRATION: This review is registered as PROSPERO CRD42015015978. FUNDING: The National Institute for Health Research Health Technology Assessment programme.


Assuntos
Cânula , Cateterismo Periférico/instrumentação , Pressão Positiva Contínua nas Vias Aéreas/métodos , Análise Custo-Benefício , Temperatura Alta/uso terapêutico , Resultado do Tratamento , Cateterismo Periférico/métodos , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Ensaios Clínicos Controlados Aleatórios como Assunto , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Avaliação da Tecnologia Biomédica
11.
Health Technol Assess ; 19(87): i-xxxi, 1-191, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26507078

RESUMO

BACKGROUND: There is no single definitive test to identify prostate cancer in men. Biopsies are commonly used to obtain samples of prostate tissue for histopathological examination. However, this approach frequently misses cases of cancer, meaning that repeat biopsies may be necessary to obtain a diagnosis. The PROGENSA(®) prostate cancer antigen 3 (PCA3) assay (Hologic Gen-Probe, Marlborough, MA, USA) and the Prostate Health Index (phi; Beckman Coulter Inc., Brea, CA, USA) are two new tests (a urine test and a blood test, respectively) that are designed to be used to help clinicians decide whether or not to recommend a repeat biopsy. OBJECTIVE: To evaluate the clinical effectiveness and cost-effectiveness of the PCA3 assay and the phi in the diagnosis of prostate cancer. DATA SOURCES: Multiple publication databases and trial registers were searched in May 2014 (from 2000 to May 2014), including MEDLINE, EMBASE, The Cochrane Library, ISI Web of Science, Medion, Aggressive Research Intelligence Facility database, ClinicalTrials.gov, International Standard Randomised Controlled Trial Number Register and World Health Organization International Clinical Trials Registry Platform. REVIEW METHODS: The assessment of clinical effectiveness involved three separate systematic reviews, namely reviews of the analytical validity, the clinical validity of these tests and the clinical utility of these tests. The assessment of cost-effectiveness comprised a systematic review of full economic evaluations and the development of a de novo economic model. SETTING: The perspective of the evaluation was the NHS in England and Wales. PARTICIPANTS: Men suspected of having prostate cancer for whom the results of an initial prostate biopsy were negative or equivocal. INTERVENTIONS: The use of the PCA3 score or phi in combination with existing tests (including histopathology results, prostate-specific antigen level and digital rectal examination), multiparametric magnetic resonance imaging and clinical judgement. RESULTS: In addition to documents published by the manufacturers, six studies were identified for inclusion in the analytical validity review. The review identified issues concerning the precision of the PCA3 assay measurements. It also highlighted issues relating to the storage requirements and stability of samples intended for analysis using the phi assay. Fifteen studies met the inclusion criteria for the clinical validity review. These studies reported results for 10 different clinical comparisons. There was insufficient evidence to enable the identification of appropriate test threshold values for use in a clinical setting. In addition, the implications of adding either the PCA3 assay or the phi to clinical assessment were not clear. Furthermore, the addition of the PCA3 assay or the phi to clinical assessment plus magnetic resonance imaging was not found to improve discrimination. No published papers met the inclusion criteria for either the clinical utility review or the cost-effectiveness review. The results from the cost-effectiveness analyses indicated that using either the PCA3 assay or the phi in the NHS was not cost-effective. LIMITATIONS: The main limitations of the systematic review of clinical validity are that the review conclusions are over-reliant on findings from one study, the descriptions of clinical assessment vary widely within reviewed studies and many of the reported results for the clinical validity outcomes do not include either standard errors or confidence intervals. CONCLUSIONS: The clinical benefit of using the PCA3 assay or the phi in combination with existing tests, scans and clinical judgement has not yet been confirmed. The results from the cost-effectiveness analyses indicate that the use of these tests in the NHS would not be cost-effective. STUDY REGISTRATION: This study is registered as PROSPERO CRD42014009595. FUNDING: The National Institute for Health Research Health Technology Assessment programme.


Assuntos
Antígenos de Neoplasias/urina , Técnicas de Amplificação de Ácido Nucleico , Próstata/anormalidades , Neoplasias da Próstata/diagnóstico , Biópsia , Análise Custo-Benefício , Inglaterra , Humanos , Imageamento por Ressonância Magnética , Masculino , Técnicas de Amplificação de Ácido Nucleico/economia , Neoplasias da Próstata/economia , Medicina Estatal , Avaliação da Tecnologia Biomédica/economia , Resultado do Tratamento , País de Gales
12.
Ocul Surf ; 12(3): 202-14, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24999102

RESUMO

This report presents the results of a systematic review and meta-analyses of studies on epithelium-off photochemical corneal collagen cross-linkage for the management of keratoconus and secondary ectasia. The literature search identified 3,400 records of which 49 were considered for inclusion in the meta-analyses. Eight papers reported 4 unique randomized controlled trials, 29 studies were prospective, and 12 were retrospective studies. The majority of the studies (39/49) were graded as very low quality evidence. Twenty-six studies described adverse events and were included in the safety analysis. Meta-analyses are presented for changes in four outcomes: visual acuity, topography, refraction and astigmatism, and central corneal thickness. Statistically significant improvements were found in all efficacy outcomes at 12 months after the operation. Common side effects were pain, corneal edema, and corneal haze, which resolved usually within a few days after the procedure. The remaining uncertainty is duration of benefit to establish the procedure's potential benefit in avoiding or delaying disease progression and possibly reducing the need for corneal transplantation.


Assuntos
Colágeno/farmacologia , Substância Própria , Ceratocone/terapia , Riboflavina/uso terapêutico , Terapia Ultravioleta/métodos , Substância Própria/efeitos dos fármacos , Substância Própria/patologia , Substância Própria/efeitos da radiação , Reagentes de Ligações Cruzadas/uso terapêutico , Humanos , Ceratocone/patologia , Fármacos Fotossensibilizantes/uso terapêutico , Raios Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA