RESUMO
BACKGROUND: Monte Carlo (MC) simulations or measurements in anthropomorphic phantoms are recommended for estimating fetal dose in pregnant patients in radiotherapy. Among the many existing phantoms, there is no commercially available physical phantom representing the entire pregnant woman. PURPOSE: In this study, the development of a low-cost, physical pregnant female phantom was demonstrated using commercially available materials. This phantom is based on the previously published computational phantom. METHODS: Three tissue substitution materials (soft tissue, lung and bone tissue substitution) were developed. To verify Tena's substitution tissue materials, their radiation properties were assessed and compared to ICRP and ICRU materials using MC simulations in MV radiotherapy beams. Validation of the physical phantom was performed by comparing fetal doses obtained by measurements in the phantom with fetal doses obtained by MC simulations in computational phantom, during an MV photon breast radiotherapy treatment. RESULTS: Materials used for building Tena phantom are matched to ICRU materials using physical density, radiation absorption properties and effective atomic number. MC simulations showed that percentage depth doses of Tena and ICRU material comply within 5% for soft and lung tissue, up to 25 cm depth. In the bone tissue, the discrepancy is higher, but again within 5% up to the depth of 5 cm. When the phantom was used for fetal dose measurements in MV photon breast radiotherapy, measured fetal doses complied with fetal doses calculated using MC simulation within 15%. CONCLUSIONS: Physical anthropomorphic phantom of pregnant patient can be manufactured using commercial materials and with low expenses. The files needed for 3D printing are now freely available. This enables further studies and comparison of numerical and physical experiments in diagnostic radiology or radiotherapy.
Assuntos
Gestantes , Radiometria , Gravidez , Humanos , Feminino , Fótons/uso terapêutico , Planejamento da Radioterapia Assistida por Computador , Simulação por Computador , Imagens de Fantasmas , Método de Monte Carlo , Dosagem RadioterapêuticaRESUMO
BACKGROUND: The incidence of carcinoma during pregnancy is reported to be 1:1000-1:1500 pregnancies with the breast carcinoma being the most commonly diagnosed. Since the fetus is most sensitive to ionizing radiation during the first two trimesters, there are mixed clinical opinions and no uniform guidelines on the use of radiotherapy during pregnancy. Within this study the pregnant female phantom in the second trimester, that can be used for radiotherapy treatment planning (as DICOM data), Monte Carlo simulations (as voxelized geometry) and experimental dosimetry utilizing 3D printing of the molds (as .STL files), was developed. MATERIALS AND METHODS: The developed phantom is based on MRI images of a female patient in her 18th week of pregnancy and CT images after childbirth. Phantom was developed in such a manner that a pregnant female was scanned "in vivo" using MRI during pregnancy and CT after childbirth. For the treatment of left breast carcinoma, 3D conformal radiotherapy was used. The voxelized geometry of the phantom was used for Monte Carlo (MC) simulations using Monte Carlo N-Particle transport codeTM 6.2 (MCNP). CONCLUSIONS: The modeled photon breast radiotherapy plan, applied to the phantom, indicated that the fetus dose is 59 mGy for 50 Gy prescribed to the breast. The results clearly indicate that only 9.5% of the fetal dose is caused by photons that are generated in the accelerator head through scattering and leakage, but the dominant component is scattered radiation from the patient's body.
Assuntos
Neoplasias da Mama , Fótons , Humanos , Gravidez , Feminino , Imagens de Fantasmas , Método de Monte Carlo , Fótons/uso terapêutico , Radiometria/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapiaRESUMO
Since 2010, EURADOS Working Group 9 (Radiation Dosimetry in Radiotherapy) has been involved in the investigation of secondary and scattered radiation doses in X-ray and proton therapy, especially in the case of pediatric patients. The main goal of this paper is to analyze and compare out-of-field neutron and non-neutron organ doses inside 5- and 10-year-old pediatric anthropomorphic phantoms for the treatment of a 5-cm-diameter brain tumor. Proton irradiations were carried out at the Cyclotron Centre Bronowice in IFJ PAN Krakow Poland using a pencil beam scanning technique (PBS) at a gantry with a dedicated scanning nozzle (IBA Proton Therapy System, Proteus 235). Thermoluminescent and radiophotoluminescent dosimeters were used for non-neutron dose measurements while secondary neutrons were measured with track-etched detectors. Out-of-field doses measured using intensity-modulated proton therapy (IMPT) were compared with previous measurements performed within a WG9 for three different photon radiotherapy techniques: 1) intensity-modulated radiation therapy (IMRT), 2) three-dimensional conformal radiation therapy (3D CDRT) performed on a Varian Clinac 2300 linear accelerator (LINAC) in the Centre of Oncology, Krakow, Poland, and 3) Gamma Knife surgery performed on the Leksell Gamma Knife (GK) at the University Hospital Centre Zagreb, Croatia. Phantoms and detectors used in experiments as well as the target location were the same for both photon and proton modalities. The total organ dose equivalent expressed as the sum of neutron and non-neutron components in IMPT was found to be significantly lower (two to three orders of magnitude) in comparison with the different photon radiotherapy techniques for the same delivered tumor dose. For IMPT, neutron doses are lower than non-neutron doses close to the target but become larger than non-neutron doses further away from the target. Results of WG9 studies have provided out-of-field dose levels required for an extensive set of radiotherapy techniques, including proton therapy, and involving a complete description of organ doses of pediatric patients. Such studies are needed for validating mathematical models and Monte Carlo simulation tools for out-of-field dosimetry which is essential for dedicated epidemiological studies which evaluate the risk of second cancers and other late effects for pediatric patients treated with radiotherapy.
RESUMO
PURPOSE: Craniospinal irradiation (CSI) has greatly increased survival rates for patients with a diagnosis of medulloblastoma and other primitive neuroectodermal tumors. However, as it includes exposure of a large volume of healthy tissue to unwanted doses, there is a strong concern about the complications of the treatment, especially for the children. To estimate the risk of second cancers and other unwanted effects, out-of-field dose assessment is necessary. The purpose of this study is to evaluate and compare out-of-field doses in pediatric CSI treatment using conventional and advanced photon radiotherapy (RT) and advanced proton therapy. To our knowledge, it is the first such comparison based on in-phantom measurements. Additionally, for out-of-field doses during photon RT in this and other studies, comparisons were made using analytical modeling. METHODS: In order to describe the out-of-field doses absorbed in a pediatric patient during actual clinical treatment, an anthropomorphic phantom, which mimics the 10-year-old child, was used. Photon 3D-conformal RT (3D-CRT) and two advanced, highly conformal techniques: photon volumetric-modulated arc therapy (VMAT) and active pencil beam scanning (PBS) proton RT were used for CSI treatment. Radiophotoluminescent and poly-allyl-diglycol-carbonate nuclear track detectors were used for photon and neutron dosimetry in the phantom, respectively. Out-of-field doses from neutrons were expressed in terms of dose equivalent. A two-Gaussian model was implemented for out-of-field doses during photon RT. RESULTS: The mean VMAT photon doses per target dose to all organs in this study were under 50% of the target dose (i.e., <500 mGy/Gy), while the mean 3D-CRT photon dose to oesophagus, gall bladder, and thyroid, exceeded that value. However, for 3D-CRT, better sparing was achieved for eyes and lungs. The mean PBS photon doses for all organs were up to three orders of magnitude lower compared to VMAT and 3D-CRT and exceeded 10 mGy/Gy only for the oesophagus, intestine, and lungs. The mean neutron dose equivalent during PBS for eight organs of interest (thyroid, breasts, lungs, liver, stomach, gall bladder, bladder, prostate) ranged from 1.2 mSv/Gy for bladder to 23.1 mSv/Gy for breasts. Comparison of out-of-field doses in this and other phantom studies found in the literature showed that a simple and fast two-Gaussian model for out-of-field doses as a function of distance from the field edge can be applied in a CSI using photon RT techniques. CONCLUSIONS: PBS is the most promising technique for out-of-field dose reduction in comparison to photon techniques. Among photon techniques, VMAT is a preferred choice for most of out-of-field organs and especially for the thyroid, while doses for eyes, breasts, and lungs are lower for 3D-CRT. For organs outside the field edge, a simple analytical model can be helpful for clinicians involved in treatment planning using photon RT but also for retrospective data analysis for cancer risk estimates and epidemiology in general.
Assuntos
Neoplasias Cerebelares , Radiação Cranioespinal , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Neoplasias Cerebelares/radioterapia , Criança , Radiação Cranioespinal/efeitos adversos , Radiação Cranioespinal/métodos , Humanos , Masculino , Órgãos em Risco/efeitos da radiação , Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Estudos RetrospectivosRESUMO
PURPOSE: The feasibility of setting-up generic, hospital-independent dose alert levels to initiate vigilance on possible skin injuries in interventional procedures was studied for three high-dose procedures (chemoembolization (TACE) of the liver, neuro-embolization (NE) and percutaneous coronary intervention (PCI)) in 9 European countries. METHODS: Gafchromic® films and thermoluminescent dosimeters (TLD) were used to determine the Maximum Skin Dose (MSD). Correlation of the online dose indicators (fluoroscopy time, kerma- or dose-area product (KAP or DAP) and cumulative air kerma at interventional reference point (Ka,r)) with MSD was evaluated and used to establish the alert levels corresponding to a MSD of 2â¯Gy and 5â¯Gy. The uncertainties of alert levels in terms of DAP and Ka,r, and uncertainty of MSD were calculated. RESULTS: About 20-30% of all MSD values exceeded 2â¯Gy while only 2-6% exceeded 5â¯Gy. The correlations suggest that both DAP and Ka,r can be used as a dose indicator for alert levels (Pearson correlation coefficient p mostly >0.8), while fluoroscopy time is not suitable (p mostly <0.6). Generic alert levels based on DAP (Gy cm2) were suggested for MSD of both 2â¯Gy and 5â¯Gy (for 5â¯Gy: TACE 750, PCI 250 and NE 400). The suggested levels are close to the lowest values published in several other studies. The uncertainty of the MSD was estimated to be around 10-15% and of hospital-specific skin dose alert levels about 20-30% (with coverage factor kâ¯=â¯1). CONCLUSIONS: The generic alert levels are feasible for some cases but should be used with caution, only as the first approximation, while hospital-specific alert levels are preferred as the final approach.
Assuntos
Fluoroscopia/efeitos adversos , Pele/efeitos da radiação , Cirurgia Assistida por Computador , Estudos de Viabilidade , Humanos , Dosimetria TermoluminescenteRESUMO
The purpose of this study was to measure out-of-field organ doses in two anthropomorphic child phantoms for the treatment of large brain arteriovenous malformations (AVMs) using hypofractionated gamma knife (GK) radiosurgery and to compare these with an alternative treatment using intensity-modulated radiation therapy (IMRT). Target volume was identical in size and shape in all cases. Radiophotoluminescent (RPL), thermoluminescent (TL) and optically stimulated luminescent (OSL) dosimeters were used for out-of-field dosimetry during GK treatment and a good agreement within 1-2% between results was shown. In addition, the use of multiple dosimetry systems strengthens the reliability of the findings. The number of GK isocentres was confirmed to be important for the magnitude of out-of-field doses. Measured GK doses for the same distance from the target, when expressed per target dose and isocentre, were comparable in both phantoms. GK out-of-field doses averaged for both phantoms were evaluated to be 120 mGy/Gy for eyes then sharply reduced to 20 mGy/Gy for mandible and slowly reduced up to 0.8 mGy/Gy for testes. Taking into account the fractionation regimen used to treat AVM patients, the total treatment organ doses to the out-of-field organs were calculated and compared with IMRT. The eyes were better spared with GK whilst for more distant organs doses were up to a factor of 2.8 and 4 times larger for GK compared to IMRT in 5-year and 10-year old phantoms, respectively. Presented out-of-field dose values are specific for the investigated AVM case, phantoms and treatment plans used for GK and IMRT, but provide useful information about out-of-field dose levels and emphasise their importance.
Assuntos
Malformações Arteriovenosas Intracranianas/cirurgia , Órgãos em Risco/efeitos da radiação , Imagens de Fantasmas , Radiometria/métodos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Criança , Humanos , Dosagem RadioterapêuticaRESUMO
The purpose of this study was to measure out-of-field organ doses in clinical conditions in anthropomorphic paediatric phantoms which received a simulated treatment of a brain tumour with intensity modulated radiotherapy (IMRT) and 3D conformal radiotherapy (3D CRT). Organ doses measured with radiophotoluminescent and thermoluminescent dosemeters were on average 1.6 and 3.0 times higher for the 5 y-old than for the 10 y-old phantom for IMRT and 3D CRT, respectively. A larger 5-y to 10-y organ dose ratio for 3D CRT can be explained because the use of a mechanical wedge for the 5-y-old 3D CRT phantom treatment increased out-of-field doses. Due to different configurations of the radiation fields, for both phantoms, the IMRT technique resulted in a higher non-target brain dose and higher eye doses but lower thyroid doses compared to 3D CRT. For 3D CRT (which used a non-coplanar field configuration), eye doses were 3-6% and for IMRT (which used a coplanar field configuration) 27-30% of the treatment dose, respectively. For thyroid and more distant organs, doses were less than 1% of the treatment dose. Comparison of measured doses and doses calculated by the treatment planning system (TPS) showed that the TPS underestimated out-of-field doses both for IMRT and 3D CRT.
Assuntos
Neoplasias Encefálicas/radioterapia , Radiação Cranioespinal/métodos , Radiometria/métodos , Dosagem Radioterapêutica , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Criança , Pré-Escolar , Humanos , Modelos Anatômicos , Órgãos em Risco/efeitos da radiaçãoRESUMO
Dosimetry for Gamma-Knife requires detectors with high spatial resolution and minimal angular dependence of response. Angular dependence and end effect time for p-type silicon detectors (PTW Diode P and Diode E) and PTW PinPoint ionization chamber were measured with Gamma-Knife beams. Weighted angular dependence correction factors were calculated for each detector. The Gamma-Knife output factors were corrected for angular dependence and end effect time. For Gamma-Knife beams angle range of 84°-54°. Diode P shows considerable angular dependence of 9% and 8% for the 18 mm and 14, 8, 4 mm collimator, respectively. For Diode E this dependence is about 4% for all collimators. PinPoint ionization chamber shows angular dependence of less than 3% for 18, 14 and 8 mm helmet and 10% for 4 mm collimator due to volumetric averaging effect in a small photon beam. Corrected output factors for 14 mm helmet are in very good agreement (within ±0.3%) with published data and values recommended by vendor (Elekta AB, Stockholm, Sweden). For the 8 mm collimator diodes are still in good agreement with recommended values (within ±0.6%), while PinPoint gives 3% less value. For the 4 mm helmet Diodes P and E show over-response of 2.8% and 1.8%, respectively. For PinPoint chamber output factor of 4 mm collimator is 25% lower than Elekta value which is generally not consequence of angular dependence, but of volumetric averaging effect and lack of lateral electronic equilibrium. Diodes P and E represent good choice for Gamma-Knife dosimetry.
Assuntos
Radiometria/instrumentação , Radiocirurgia/métodos , Algoritmos , Humanos , Íons , Método de Monte Carlo , Imagens de Fantasmas , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Reprodutibilidade dos Testes , SoftwareRESUMO
Although ionising radiation has proven beneficial in the diagnosis and therapy of a number of diseases, one should keep in mind that irradiating healthy tissue may increase the risk of cancer. In order to justify an exposure to radiation, both the benefits and the risks must be evaluated and compared. The deleterious effects of medium and high doses are well known, but it is much less clear what effects arise from low doses (below 0.1 Gy), which is why such risk estimates are extremely important. This review presents the current state, important assumptions and steps being made in deriving cancer risk estimates for low dose exposures.