1.
Phys Med ; 54: 42-48, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30337009

RESUMO

Interventional cardiac procedures may be associated with high patient doses and therefore require special attention to protect the patients from radiation injuries such as skin erythema, cardiovascular tissue reactions or radiation-induced cancer. In this study, patient exposure data is collected from 13 countries (37 clinics and nearly 50 interventional rooms) and for 10 different procedures. Dose data was collected from a total of 14,922 interventional cardiology procedures. Based on these data European diagnostic reference levels (DRL) for air kerma-area product are suggested for coronary angiography (CA, DRL = 35 Gy cm2), percutaneous coronary intervention (PCI, 85 Gy cm2), transcatheter aortic valve implantation (TAVI, 130 Gy cm2), electrophysiological procedures (12 Gy cm2) and pacemaker implantations. Pacemaker implantations were further divided into single-chamber (2.5 Gy cm2) and dual chamber (3.5 Gy cm2) procedures and implantations of cardiac resynchronization therapy pacemaker (18 Gy cm2). Results show that relatively new techniques such as TAVI and treatment of chronic total occlusion (CTO) often produce relatively high doses, and thus emphasises the need for use of an optimization tool such as DRL to assist in reducing patient exposure. The generic DRL presented here facilitate comparison of patient exposure in interventional cardiology.


Assuntos
Cardiologia/normas , Europa (Continente) , Valores de Referência
2.
Phys Med ; 31(8): 1112-1117, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26439858

RESUMO

PURPOSE: Point detectors are frequently used to measure patient's maximum skin dose (MSD) in fluoroscopically-guided interventional procedures (IP). However, their performance and ability to detect the actual MSD are rarely evaluated. The present study investigates the sampling uncertainty associated with the use of grids of point detectors to measure MSD in IP. METHOD: Chemoembolisation of the liver (CE), percutaneous coronary intervention (PCI) and neuroembolisation (NE) procedures were studied. Spatial dose distributions were measured with XR-RV3 Gafchromic(®) films for 176 procedures. These distributions were used to simulate measurements performed using grids of detectors such as thermoluminescence detectors, with detector spacing from 1.4 up to 10 cm. RESULTS: The sampling uncertainty was the highest in PCI and NE procedures. With 40 detectors covering the film area (36 cm × 44 cm), the maximum dose would be on average 86% and 63% of the MSD measured with Gafchromic(®) films in CE and PCI procedures, respectively. In NE procedures, with 27 detectors covering the film area (14 cm × 35 cm), the maximum dose measured would be on average 82% of the MSD obtained with the Gafchromic(®) films. CONCLUSION: Thermoluminescence detectors show good energy and dose response in clinical beam qualities. However the poor spatial resolution of such point-like dosimeters may far outweigh their good dosimetric properties. The uncertainty from the sampling procedure should be estimated when point detectors are used in IP because it may lead to strong underestimation of the MSD.


Assuntos
Quimioembolização Terapêutica/métodos , Intervenção Coronária Percutânea/métodos , Doses de Radiação , Pele/efeitos da radiação , Fluoroscopia , Dosimetria Termoluminescente , Incerteza
3.
Radiat Prot Dosimetry ; 164(1-2): 138-42, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25316909

RESUMO

To help operators acknowledge patient dose during interventional procedures, EURADOS WG-12 focused on measuring patient skin dose using XR-RV3 gafchromic films, thermoluminescent detector (TLD) pellets or 2D TL foils and on investigating possible correlation to the on-line dose indicators such as fluoroscopy time, Kerma-area product (KAP) and cumulative air Kerma at reference point (CK). The study aims at defining non-centre-specific European alert thresholds for skin dose in three interventional procedures: chemoembolization of the liver (CE), neuroembolization (NE) and percutaneous coronary interventions (PCI). Skin dose values of >3 Gy (ICRP threshold for skin injuries) were indeed measured in these procedures confirming the need for dose indicators that correlate with maximum skin dose (MSD). However, although MSD showed fairly good correlation with KAP and CK, several limitations were identified challenging the set-up of non-centre-specific European alert thresholds. This paper presents preliminary results of this wide European measurement campaign and focuses on the main challenges in the definition of European alert thresholds.


Assuntos
Procedimentos Cirúrgicos Cardiovasculares/métodos , Radiografia Intervencionista/métodos , Radiometria/instrumentação , Pele/diagnóstico por imagem , Raios X , Absorção de Radiação , Humanos , Concentração Máxima Permitida , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fenômenos Fisiológicos da Pele/efeitos da radiação
4.
Phys Med ; 30(8): 934-40, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25277316

RESUMO

The accumulated dose to the skin of the patient during fluoroscopically-guided procedures can exceed the thresholds for tissue reactions. In practice, interventionalists have no direct information about the local procedure-related skin doses in their patient, causing suboptimal or delayed treatment. In current study, the accumulated Kerma-Area-Product (KAP) values were registered, as well as the reference air kerma (Ka,r) values, if available, for almost 200 cases undergoing seven different procedures. A sheet filled with 50 thermoluminescent dosemeters was wrapped around each patient to measure the peak skin dose. In a significant part of the Transjugular Intrahepatic Portosystemic Shunt (TIPSS) procedures, chemo-embolizations of the liver and cerebral embolizations, the threshold values for deterministic skin damage (2 Gy) were attained. Trigger values in terms of KAP, corresponding to a peak skin dose of 2 Gy, were determined. In general, our results comply reasonably well with the values proposed in the NCRP 168 report, with a KAP value of 425 Gy cm² and a Ka,r value of 3 Gy, corresponding to a peak skin dose of 3 Gy. Only for the TIPSS procedure a considerably lower value of 2 Gy was obtained at the published Ka,r and for the RF ablations we obtained a considerably lower value of 250 Gy cm² in terms of KAP.


Assuntos
Fluoroscopia/instrumentação , Proteção Radiológica/instrumentação , Radiologia Intervencionista/métodos , Pele/lesões , Pele/efeitos da radiação , Bélgica , Calibragem , Vestuário , Fluoroscopia/métodos , Seguimentos , Humanos , Cinética , Doses de Radiação , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Dosimetria Termoluminescente/métodos , Raios X
5.
Radiat Prot Dosimetry ; 129(1-3): 50-5, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18283058

RESUMO

The purpose of this study was to determine diagnostic reference levels (DRLs) for common angiographic and interventional procedures in Belgium. Dose Area Product (DAP) measurements were performed on 21 systems, (13 angiography and 4 vascular surgery centres). Type of procedure, total DAP, patient weight and height were collected on a daily basis during 1 y. The 75th percentile of the distribution of DAP values was defined as DRL. Preliminary DRLs were calculated for the three most frequent procedures for the whole population, for a weight class of patients (65-80 kg) and normalised to the standard size patient. Among them, the DRL for angiography of the lower limbs (30% of the procedures) from the whole population was 74.6 and 63.2 Gycm2 for the size corrected. The mean DAP values of each room was then compared to these DRLs.


Assuntos
Angiografia/normas , Diagnóstico por Imagem/normas , Extremidade Inferior/diagnóstico por imagem , Doses de Radiação , Radiologia Intervencionista/normas , Valores de Referência , Idoso , Angiografia/métodos , Bélgica , Diagnóstico por Imagem/métodos , Feminino , Fluoroscopia/métodos , Fluoroscopia/normas , Humanos , Masculino , Pessoa de Meia-Idade , Controle de Qualidade , Monitoramento de Radiação/métodos , Radiologia Intervencionista/instrumentação , Radiologia Intervencionista/métodos
6.
Radiology ; 169(1): 55-8, 1988 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-2843941

RESUMO

The radiologic appearance of tissue surrounding a tumor often influences the characterization of a cancerous lesion. An example is the radiolucent halo that is sometimes seen around breast cancers. Mammograms of 108 malignant tumors (74 scirrhous tumors, 17 partially scirrhous nodular tumors, and 17 nodular tumors) and eight benign tumors that showed peritumoral fat were retrospectively evaluated. All the scirrhous and partially scirrhous nodular cancers were more or less surrounded by a 5-10-mm-wide hyperlucent halo; this corona sign was also found in 14 nodular cancers. The halo sign, a hyperleucent 1-mm band, was observed around all benign lesions and immediately adjacent to sharply delineated cancers. These radiologic findings are an optical illusion (Mach band, background contrast effect). Densitometric measures and isoluminous analysis did not demonstrate the presence of a true hyperlucent zone.


Assuntos
Adenocarcinoma Esquirroso/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Mamografia , Absorciometria de Fóton , Feminino , Humanos , Ilusões Ópticas , Estudos Retrospectivos , Xeromamografia
7.
Artigo em Francês | MEDLINE | ID: mdl-4008887

RESUMO

A recent immunofluorescent study has tried to define the precise nature of the macromolecules present in the connective tissue of normal and fibrocystic breasts. Nothing abnormal has been found in the distribution of the different types of collagen and of the two glycoproteins, namely fibronectin and laminin. A quantitative approach to the research into the composition of the organ has brought us to realise that there are different amounts of the constituents of the connective tissue to be found in 80 samples which have been taken from 4 specific regions of the breast. These have been taken from 16 women aged between 28 and 82 with a mean age of 57 years. Their breasts could be ascribed to different clinical and radiological categories. We have been able to show that there is a significant rise in the water content as well as in the collagen content and, to a lesser degree, in the total proteins of the body of the breast as compared with the fatty layer in front of the breast. This increase is compensated for by a significant lessening in the percentage of lipids. It was not possible to demonstrate a statistically significant difference between these two regions as far as the concentration of proteoglycans and glycoproteins. Fibrous types of breast have, in the main body of the breast, a significant increase in the percentage of water, collagen, proteoglycans and glycoproteins as compared with fatty breasts.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Mama/análise , Tecido Conjuntivo/análise , Doença da Mama Fibrocística/patologia , Adulto , Composição Corporal , Líquidos Corporais/análise , Mama/anatomia & histologia , Mama/patologia , Colágeno/análise , Tecido Conjuntivo/anatomia & histologia , Tecido Conjuntivo/patologia , Feminino , Humanos , Lipídeos/análise , Pessoa de Meia-Idade