Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Front Public Health ; 9: 661376, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33898384

RESUMO

When a radiological and nuclear (R/N) emergency occurs, the categorization of individuals into those who are unaffected and those requiring medical intervention is a high priority. At times, a professional dosimeter is not available and therefore some common belongings may be used as fortuitous dosimeters. The preparation of these objects for the measurement should be such as to give the most accurate and precise results. This paper focused on the Photo-Stimulated Luminescence (PSL) response of salty crackers confronts the problem of sample preparation (mass, grain size), dose response and signal stability. The dose response was determined for doses up to 5 Gy, which allowed the calculation of the limit of detection. Additionally, the signal stability was investigated for samples irradiated with 0.3 and 3 Gy. The observed decrease of the signal does not prevent the detection in the dose range typical for R/N emergency. The main dosimetric characteristics were investigated by using two different models of PSL readers equipped with single (infrared) or double (infrared, blue light) stimulation. The results indicated that the limit of detection can be improved by applying blue light stimulation. Moreover, strong correlation of the measurements performed in the two different instruments, as well as the rapidity of the analysis and the simplicity of the operations, suggest that this method can be suitable for a rapid radiation triage of a large number of civilians in a mass casualty event. The study was simultaneously conducted by two laboratories (Ruder Boskovic Institute, RBI, Croatia and Istituto Superiore di Sanità, ISS, Italy) involved in the BioPhyMeTRE project (grant No. G5684) supported by NATO Science for Peace and Security Programme.


Assuntos
Dosímetros de Radiação , Triagem , Croácia , Humanos , Itália , Radiometria
2.
Radiat Prot Dosimetry ; 178(4): 382-404, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28981844

RESUMO

Biological and physical retrospective dosimetry are recognised as key techniques to provide individual estimates of dose following unplanned exposures to ionising radiation. Whilst there has been a relatively large amount of recent development in the biological and physical procedures, development of statistical analysis techniques has failed to keep pace. The aim of this paper is to review the current state of the art in uncertainty analysis techniques across the 'EURADOS Working Group 10-Retrospective dosimetry' members, to give concrete examples of implementation of the techniques recommended in the international standards, and to further promote the use of Monte Carlo techniques to support characterisation of uncertainties. It is concluded that sufficient techniques are available and in use by most laboratories for acute, whole body exposures to highly penetrating radiation, but further work will be required to ensure that statistical analysis is always wholly sufficient for the more complex exposure scenarios.


Assuntos
Doses de Radiação , Radiometria/métodos , Incerteza , Carga Corporal (Radioterapia) , Europa (Continente) , Humanos , Monitoramento de Radiação , Radiação Ionizante , Medição de Risco/métodos
3.
Appl Radiat Isot ; 83 Pt A: 41-6, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24246553

RESUMO

Electron paramagnetic resonance (EPR) signals induced by γ-radiation in different polymorphic forms of trehalose were studied with dosimetry applications in view. Dose response of trehalose in terms of the concentration of induced paramagnetic centers was studied in the dose range from 0.5 to 50 kGy. The dependences of the dose responses of anhydrous ß-crystalline trehalose (TRE(ß)) and glassy trehalose (TRE(g)) on dose are linear up to 15 kGy, whereas the linearity of the dependence for trehalose dihydrate (TRE(h)) is limited to about 10 kGy. At doses above 15 kGy, the dependences get saturated for all three forms. The relative radiation sensitivities pointed to the following order of decreasing concentrations of radiation-induced paramagnetic centers in the forms: TRE(g)>TRE(ß)>TRE(h). The results showed that at all three trehalose polymorphic forms are suitable for dosimetry, especially for retrospective dose measurements. Also, thermal stability and decay kinetics of the EPR signals of the different forms of trehalose were studied in isothermal annealing experiments. The kinetic parameters, which had been derived by fitting the Arrhenius function to the measured decay rate constants, indicated that the fading of the EPR signals varied from one polymorphic form of trehalose to another. This emphasizes the impact of the molecular packing in the vicinity of the radiation-induced paramagnetic centers on their stability.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica , Trealose/química , Trealose/efeitos da radiação , Cristalização , Relação Dose-Resposta à Radiação , Raios gama , Termodinâmica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA