1.
Eur J Radiol ; 162: 110782, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37004362

RESUMO

PURPOSE: VERDICT (Vascular, Extracellular, Restricted Diffusion for Cytometry in Tumours) MRI is a multi b-value, variable diffusion time DWI sequence that allows generation of ADC maps from different b-value and diffusion time combinations. The aim was to assess precision of prostate ADC measurements from varying b-value combinations using VERDICT and determine which protocol provides the most repeatable ADC. MATERIALS AND METHODS: Forty-one men (median age: 67.7 years) from a prior prospective VERDICT study (April 2016-October 2017) were analysed retrospectively. Men who were suspected of prostate cancer and scanned twice using VERDICT were included. ADC maps were formed using 5b-value combinations and the within-subject standard deviations (wSD) were calculated per ADC map. Three anatomical locations were analysed per subject: normal TZ (transition zone), normal PZ (peripheral zone), and index lesions. Repeated measures ANOVAs showed which b-value range had the lowest wSD, Spearman correlation and generalized linear model regression analysis determined whether wSD was related to ADC magnitude and ROI size. RESULTS: The mean lesion ADC for b0b1500 had the lowest wSD in most zones (0.18-0.58x10-4 mm2/s). The wSD was unaffected by ADC magnitude (Lesion: p = 0.064, TZ: p = 0.368, PZ: p = 0.072) and lesion Likert score (p = 0.95). wSD showed a decrease with ROI size pooled over zones (p = 0.019, adjusted regression coefficient = -1.6x10-3, larger ROIs for TZ versus PZ versus lesions). ADC maps formed with a maximum b-value of 500 s/mm2 had the largest wSDs (1.90-10.24x10-4 mm2/s). CONCLUSION: ADC maps generated from b0b1500 have better repeatability in normal TZ, normal PZ, and index lesions.


Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Idoso , Próstata/diagnóstico por imagem , Próstata/patologia , Estudos Prospectivos , Estudos Retrospectivos , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia
2.
Med Phys ; 49(5): 3325-3332, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35184316

RESUMO

OBJECTIVE: The goal of this work is to provide temperature and concentration calibration of water diffusivity in polyvinylpyrrolidone (PVP) solutions used in phantoms to assess system bias and linearity in apparent diffusion coefficient (ADC) measurements. METHOD: ADC measurements were performed for 40 kDa (K40) PVP of six concentrations (0%, 10%, 20%, 30%, 40%, and 50% by weight) at three temperatures (19.5°C, 22.5°C, and 26.4°C), with internal phantom temperature monitored by optical thermometer (±0.2°C). To achieve ADC measurement and fit accuracy of better than 0.5%, three orthogonal diffusion gradients were calibrated using known water diffusivity at 0°C and system gradient nonlinearity maps. Noise-floor fit bias was also controlled by limiting the maximum b-value used for ADC calculation of each sample. The ADC temperature dependence was modeled by Arrhenius functions of each PVP concentration. The concentration dependence was modeled by quadratic function for ADC normalized by the theoretical water diffusion values. Calibration coefficients were obtained from linear regression model fits. RESULTS: Measured phantom ADC values increased with temperature and decreasing PVP concentration, [PVP]. The derived Arrhenius model parameters for [PVP] between 0% and 50%, are reported and can be used for K40 ADC temperature calibration with absolute ADC error within ±0.016 µm2 /ms. Arrhenius model fit parameters normalized to water value scaled with [PVP] between 10% and 40%, and proportional change in activation energy increased faster than collision frequency. ADC normalization by water diffusivity, DW , from the Speedy-Angell relation accounted for the bulk of temperature dependence (±0.035 µm2 /ms) and yielded quadratic calibration for ADCPVP /DW  = (12.5 ± 0.7) ·10-5 ·[PVP]2 - (23.2 ± 0.3)·10-3 ·[PVP]+1, nearly independent of PVP molecular weight and temperature. CONCLUSION: The study provides ground-truth ADC values for K40 PVP solutions commonly used in diffusion phantoms for scanning at ambient room temperature. The described procedures and the reported calibration can be used for quality control and standardization of measured ADC values of PVP at different concentrations and temperatures.


Assuntos
Povidona , Água , Difusão , Imagem de Difusão por Ressonância Magnética/métodos , Imagens de Fantasmas , Temperatura
3.
Magn Reson Med ; 87(4): 2053-2062, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34775621

RESUMO

PURPOSE: To demonstrate a method for quantification of impeded diffusion fraction (IDF) using conventional clinical DWI protocols. METHODS: The IDF formalism is introduced to quantify contribution from water coordinated by macromolecules to DWI voxel signal based on fundamentally different diffusion constants in vascular capillary, bulk free, and coordinated water compartments. IDF accuracy was studied as a function of b-value set. The IDF scaling with restricted compartment size and polyvinylpirrolidone (PVP) macromolecule concentration was compared to conventional apparent diffusion coefficient (ADC) and isotropic kurtosis model parameters for a diffusion phantom. An in vivo application was demonstrated for six prostate cancer (PCa) cases with low and high grade lesions annotated from whole mount histopathology. RESULTS: IDF linearly scaled with known restricted (vesicular) compartment size and PVP concentration in phantoms and increased with histopathologic score in PCa (from median 9% for atrophy up to 60% for Gleason 7). IDF via non-linear fit was independent of b-value subset selected between b = 0.1 and 2 ms/µm2 , including standard-of-care (SOC) PCa protocol. With maximum sensitivity for high grade PCa, the IDF threshold below 51% reduced false positive rate (FPR = 0/6) for low-grade PCa compared to apparent diffusion coefficient (ADC > 0.81 µm2 /ms) of PIRADS PCa scoring (FPR = 3/6). CONCLUSION: The proposed method may provide quantitative imaging assays of cancer grading using common SOC DWI protocols.


Assuntos
Neoplasias da Próstata , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Masculino , Gradação de Tumores , Imagens de Fantasmas , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Água
4.
Phys Med ; 86: 113-120, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34107440

RESUMO

PURPOSE: To empirically corroborate vendor-provided gradient nonlinearity (GNL) characteristics and demonstrate efficient GNL bias correction for human brain apparent diffusion coefficient (ADC) across 3T MR systems and spatial locations. METHODS: Spatial distortion vector fields (DVF) were mapped in 3D using a surface fiducial array phantom for individual gradient channels on three 3T MR platforms from different vendors. Measured DVF were converted into empirical 3D GNL tensors and compared with their theoretical counterparts derived from vendor-provided spherical harmonic (SPH) coefficients. To illustrate spatial impact of GNL on ADC, diffusion weighted imaging using three orthogonal gradient directions was performed on a volunteer brain positioned at isocenter (as a reference) and offset superiorly by 10-17 cm (>10% predicted GNL bias). The SPH tensor-based GNL correction was applied to individual DWI gradient directions, and derived ADC was compared with low-bias reference for human brain white matter (WM) ROIs. RESULTS: Empiric and predicted GNL errors were comparable for all three studied 3T MR systems, with <1.0% differences in the median and width of spatial histograms for individual GNL tensor elements. Median (±width) of ADC (10-3mm2/s) histograms measured at isocenter in WM reference ROIs from three MR systems were: 0.73 ± 0.11, 0.71 ± 0.14, 0.74 ± 0.17, and at off-isocenters (before versus after GNL correction) were respectively 0.63 ± 0.14 versus 0.72 ± 0.11, 0.53 ± 0.16 versus 0.74 ± 0.18, and 0.65 ± 0.16 versus 0.76 ± 0.18. CONCLUSION: The phantom-based spatial distortion measurements validated vendor-provided gradient fields, and accurate WM ADC was recovered regardless of spatial locations and clinical MR platforms using system-specific tensor-based GNL correction for routine DWI.


Assuntos
Imagem de Difusão por Ressonância Magnética , Dinâmica não Linear , Encéfalo/diagnóstico por imagem , Humanos , Oncologia , Imagens de Fantasmas , Reprodutibilidade dos Testes
5.
J Breast Imaging ; 3(1): 44-56, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33543122

RESUMO

OBJECTIVE: The A6702 multisite trial confirmed that apparent diffusion coefficient (ADC) measures can improve breast MRI accuracy and reduce unnecessary biopsies, but also found that technical issues rendered many lesions non-evaluable on diffusion-weighted imaging (DWI). This secondary analysis investigated factors affecting lesion evaluability and impact on diagnostic performance. METHODS: The A6702 protocol was IRB-approved at 10 institutions; participants provided informed consent. In total, 103 women with 142 MRI-detected breast lesions (BI-RADS assessment category 3, 4, or 5) completed the study. DWI was acquired at 1.5T and 3T using a four b-value, echo-planar imaging sequence. Scans were reviewed for multiple quality factors (artifacts, signal-to-noise, misregistration, and fat suppression); lesions were considered non-evaluable if there was low confidence in ADC measurement. Associations of lesion evaluability with imaging and lesion characteristics were determined. Areas under the receiver operating characteristic curves (AUCs) were compared using bootstrapping. RESULTS: Thirty percent (42/142) of lesions were non-evaluable on DWI; 23% (32/142) with image quality issues, 7% (10/142) with conspicuity and/or localization issues. Misregistration was the only factor associated with non-evaluability (P = 0.001). Smaller (≤10 mm) lesions were more commonly non-evaluable than larger lesions (p <0.03), though not significant after multiplicity correction. The AUC for differentiating benign and malignant lesions increased after excluding non-evaluable lesions, from 0.61 (95% CI: 0.50-0.71) to 0.75 (95% CI: 0.65-0.84). CONCLUSION: Image quality remains a technical challenge in breast DWI, particularly for smaller lesions. Protocol optimization and advanced acquisition and post-processing techniques would help to improve clinical utility.

6.
Radiology ; 298(1): 60-70, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33201788

RESUMO

Background The Eastern Cooperative Oncology Group and American College of Radiology Imaging Network Cancer Research Group A6702 multicenter trial helped confirm the potential of diffusion-weighted MRI for improving differential diagnosis of suspicious breast abnormalities and reducing unnecessary biopsies. A prespecified secondary objective was to explore the relative value of different approaches for quantitative assessment of lesions at diffusion-weighted MRI. Purpose To determine whether alternate calculations of apparent diffusion coefficient (ADC) can help further improve diagnostic performance versus mean ADC values alone for analysis of suspicious breast lesions at MRI. Materials and Methods This prospective trial (ClinicalTrials.gov identifier: NCT02022579) enrolled consecutive women (from March 2014 to April 2015) with a Breast Imaging Reporting and Data System category of 3, 4, or 5 at breast MRI. All study participants underwent standardized diffusion-weighted MRI (b = 0, 100, 600, and 800 sec/mm2). Centralized ADC measures were performed, including manually drawn whole-lesion and hotspot regions of interest, histogram metrics, normalized ADC, and variable b-value combinations. Diagnostic performance was estimated by using the area under the receiver operating characteristic curve (AUC). Reduction in biopsy rate (maintaining 100% sensitivity) was estimated according to thresholds for each ADC metric. Results Among 107 enrolled women, 81 lesions with outcomes (28 malignant and 53 benign) in 67 women (median age, 49 years; interquartile range, 41-60 years) were analyzed. Among ADC metrics tested, none improved diagnostic performance versus standard mean ADC (AUC, 0.59-0.79 vs AUC, 0.75; P = .02-.84), and maximum ADC had worse performance (AUC, 0.52; P < .001). The 25th-percentile ADC metric provided the best performance (AUC, 0.79; 95% CI: 0.70, 0.88), and a threshold using median ADC provided the greatest reduction in biopsy rate of 23.9% (95% CI: 14.8, 32.9; 16 of 67 BI-RADS category 4 and 5 lesions). Nonzero minimum b value (100, 600, and 800 sec/mm2) did not improve the AUC (0.74; P = .28), and several combinations of two b values (0 and 600, 100 and 600, 0 and 800, and 100 and 800 sec/mm2; AUC, 0.73-0.76) provided results similar to those seen with calculations of four b values (AUC, 0.75; P = .17-.87). Conclusion Mean apparent diffusion coefficient calculated with a two-b-value acquisition is a simple and sufficient diffusion-weighted MRI metric to augment diagnostic performance of breast MRI compared with more complex approaches to apparent diffusion coefficient measurement. © RSNA, 2020 Online supplemental material is available for this article.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Adulto , Idoso , Mama/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sociedades Médicas , Adulto Jovem
7.
Tomography ; 6(2): 86-92, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32548284

RESUMO

The presented analysis of multisite, multiplatform clinical oncology trial data sought to enhance quantitative utility of the apparent diffusion coefficient (ADC) metric, derived from diffusion-weighted magnetic resonance imaging, by reducing technical interplatform variability owing to systematic gradient nonlinearity (GNL). This study tested the feasibility and effectiveness of a retrospective GNL correction (GNC) implementation for quantitative quality control phantom data, as well as in a representative subset of 60 subjects from the ACRIN 6698 breast cancer therapy response trial who were scanned on 6 different gradient systems. The GNL ADC correction based on a previously developed formalism was applied to trace-DWI using system-specific gradient-channel fields derived from vendor-provided spherical harmonic tables. For quantitative DWI phantom images acquired in typical breast imaging positions, the GNC improved interplatform accuracy from a median of 6% down to 0.5% and reproducibility of 11% down to 2.5%. Across studied trial subjects, GNC increased low ADC (<1 µm2/ms) tumor volume by 16% and histogram percentiles by 5%-8%, uniformly shifting percentile-dependent ADC thresholds by ∼0.06 µm2/ms. This feasibility study lays the grounds for retrospective GNC implementation in multiplatform clinical imaging trials to improve accuracy and reproducibility of ADC metrics used for breast cancer treatment response prediction.


Assuntos
Neoplasias da Mama , Mama , Imagem de Difusão por Ressonância Magnética , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Dinâmica não Linear , Reprodutibilidade dos Testes , Estudos Retrospectivos
8.
Tomography ; 6(2): 177-185, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32548294

RESUMO

Mean tumor apparent diffusion coefficient (ADC) of breast cancer showed excellent repeatability but only moderate predictive power for breast cancer therapy response in the ACRIN 6698 multicenter imaging trial. Previous single-center studies have shown improved predictive performance for alternative ADC histogram metrics related to low ADC dense tumor volume. Using test/retest (TT/RT) 4 b-value diffusion-weighted imaging acquisitions from pretreatment or early-treatment time-points on 71 ACRIN 6698 patients, we evaluated repeatability for ADC histogram metrics to establish confidence intervals and inform predictive models for future therapy response analysis. Histograms were generated using regions of interest (ROIs) defined separately for TT and RT diffusion-weighted imaging. TT/RT repeatability and intra- and inter-reader reproducibility (on a 20-patient subset) were evaluated using wCV and Bland-Altman limits of agreement for histogram percentiles, low-ADC dense tumor volumes, and fractional volumes (normalized to total histogram volume). Pearson correlation was used to reveal connections between metrics and ROI variability across the sample cohort. Low percentiles (15th and 25th) were highly repeatable and reproducible, wCV < 8.1%, comparable to mean ADC values previously reported. Volumetric metrics had higher wCV values in all cases, with fractional volumes somewhat better but at least 3 times higher than percentile wCVs. These metrics appear most sensitive to ADC changes around a threshold of 1.2 µm2/ms. Volumetric results were moderately to strongly correlated with ROI size. In conclusion, Lower histogram percentiles have comparable repeatability to mean ADC, while ADC-thresholded volumetric measures currently have poor repeatability but may benefit from improvements in ROI techniques.


Assuntos
Neoplasias da Mama , Imagem de Difusão por Ressonância Magnética , Benchmarking , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Feminino , Humanos , Reprodutibilidade dos Testes , Carga Tumoral
9.
Tomography ; 5(1): 7-14, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30854437

RESUMO

Noninvasive imaging methods are sought to objectively predict early response to therapy for high-grade glioma tumors. Quantitative metrics derived from diffusion-weighted imaging, such as apparent diffusion coefficient (ADC), have previously shown promise when used in combination with voxel-based analysis reflecting regional changes. The functional diffusion mapping (fDM) metric is hypothesized to be associated with volume of tumor exhibiting an increasing ADC owing to effective therapeutic action. In this work, the reference fDM-predicted survival (from previous study) for 3 weeks from treatment initiation (midtreatment) is compared to multiple histogram-based metrics using Kaplan-Meier estimator for 80 glioma patients stratified to responders and nonresponders based on the population median value for the given metric. The ADC histogram metric reflecting reduction in midtreatment volume of solid tumor (ADC < 1.25 × 10-3 mm2/s) by >8% population-median with respect to pretreatment is found to have the same predictive power as the reference fDM of increasing midtreatment ADC volume above 4%. This study establishes the level of correlation between fDM increase and low-ADC tumor volume shrinkage for prediction of early response to radiation therapy in patients with glioma malignancies.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Glioma/diagnóstico por imagem , Adulto , Idoso , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/radioterapia , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Glioma/patologia , Glioma/radioterapia , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Prognóstico , Resultado do Tratamento
10.
Tomography ; 5(1): 15-25, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30854438

RESUMO

The aim of this study was to establish the repeatability measures of quantitative Gaussian and non-Gaussian diffusion metrics using diffusion-weighted imaging (DWI) data from phantoms and patients with head-and-neck and papillary thyroid cancers. The Quantitative Imaging Biomarker Alliance (QIBA) DWI phantom and a novel isotropic diffusion kurtosis imaging phantom were scanned at 3 different sites, on 1.5T and 3T magnetic resonance imaging systems, using standardized multiple b-value DWI acquisition protocol. In the clinical component of this study, a total of 60 multiple b-value DWI data sets were analyzed for test-retest, obtained from 14 patients (9 head-and-neck squamous cell carcinoma and 5 papillary thyroid cancers). Repeatability of quantitative DWI measurements was assessed by within-subject coefficient of variation (wCV%) and Bland-Altman analysis. In isotropic diffusion kurtosis imaging phantom vial with 2% ceteryl alcohol and behentrimonium chloride solution, the mean apparent diffusion (Dapp × 10-3 mm2/s) and kurtosis (Kapp, unitless) coefficient values were 1.02 and 1.68 respectively, capturing in vivo tumor cellularity and tissue microstructure. For the same vial, Dapp and Kapp mean wCVs (%) were ≤1.41% and ≤0.43% for 1.5T and 3T across 3 sites. For pretreatment head-and-neck squamous cell carcinoma, apparent diffusion coefficient, D, D*, K, and f mean wCVs (%) were 2.38%, 3.55%, 3.88%, 8.0%, and 9.92%, respectively; wCVs exhibited a higher trend for papillary thyroid cancers. Knowledge of technical precision and bias of quantitative imaging metrics enables investigators to properly design and power clinical trials and better discern between measurement variability versus biological change.


Assuntos
Imagem de Difusão por Ressonância Magnética/normas , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Imagens de Fantasmas , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Adulto , Idoso , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
11.
Tomography ; 5(1): 99-109, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30854447

RESUMO

This multicenter study evaluated the effect of variations in arterial input function (AIF) determination on pharmacokinetic (PK) analysis of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) data using the shutter-speed model (SSM). Data acquired from eleven prostate cancer patients were shared among nine centers. Each center used a site-specific method to measure the individual AIF from each data set and submitted the results to the managing center. These AIFs, their reference tissue-adjusted variants, and a literature population-averaged AIF, were used by the managing center to perform SSM PK analysis to estimate Ktrans (volume transfer rate constant), ve (extravascular, extracellular volume fraction), kep (efflux rate constant), and τi (mean intracellular water lifetime). All other variables, including the definition of the tumor region of interest and precontrast T1 values, were kept the same to evaluate parameter variations caused by variations in only the AIF. Considerable PK parameter variations were observed with within-subject coefficient of variation (wCV) values of 0.58, 0.27, 0.42, and 0.24 for Ktrans, ve, kep, and τi, respectively, using the unadjusted AIFs. Use of the reference tissue-adjusted AIFs reduced variations in Ktrans and ve (wCV = 0.50 and 0.10, respectively), but had smaller effects on kep and τi (wCV = 0.39 and 0.22, respectively). kep is less sensitive to AIF variation than Ktrans, suggesting it may be a more robust imaging biomarker of prostate microvasculature. With low sensitivity to AIF uncertainty, the SSM-unique τi parameter may have advantages over the conventional PK parameters in a longitudinal study.


Assuntos
Neoplasias da Próstata/irrigação sanguínea , Neoplasias da Próstata/diagnóstico por imagem , Algoritmos , Artérias/diagnóstico por imagem , Meios de Contraste/farmacocinética , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Disseminação de Informação , Imageamento por Ressonância Magnética/métodos , Masculino , Modelos Biológicos , Neovascularização Patológica/diagnóstico por imagem , Reprodutibilidade dos Testes
12.
Magn Reson Med ; 79(5): 2564-2575, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28913930

RESUMO

PURPOSE: To determine the in vitro accuracy, test-retest repeatability, and interplatform reproducibility of T1 quantification protocols used for dynamic contrast-enhanced MRI at 1.5 and 3 T. METHODS: A T1 phantom with 14 samples was imaged at eight centers with a common inversion-recovery spin-echo (IR-SE) protocol and a variable flip angle (VFA) protocol using seven flip angles, as well as site-specific protocols (VFA with different flip angles, variable repetition time, proton density, and Look-Locker inversion recovery). Factors influencing the accuracy (deviation from reference NMR T1 measurements) and repeatability were assessed using general linear mixed models. Interplatform reproducibility was assessed using coefficients of variation. RESULTS: For the common IR-SE protocol, accuracy (median error across platforms = 1.4-5.5%) was influenced predominantly by T1 sample (P < 10-6 ), whereas test-retest repeatability (median error = 0.2-8.3%) was influenced by the scanner (P < 10-6 ). For the common VFA protocol, accuracy (median error = 5.7-32.2%) was influenced by field strength (P = 0.006), whereas repeatability (median error = 0.7-25.8%) was influenced by the scanner (P < 0.0001). Interplatform reproducibility with the common VFA was lower at 3 T than 1.5 T (P = 0.004), and lower than that of the common IR-SE protocol (coefficient of variation 1.5T: VFA/IR-SE = 11.13%/8.21%, P = 0.028; 3 T: VFA/IR-SE = 22.87%/5.46%, P = 0.001). Among the site-specific protocols, Look-Locker inversion recovery and VFA (2-3 flip angles) protocols showed the best accuracy and repeatability (errors < 15%). CONCLUSIONS: The VFA protocols with 2 to 3 flip angles optimized for different applications achieved acceptable balance of extensive spatial coverage, accuracy, and repeatability in T1 quantification (errors < 15%). Further optimization in terms of flip-angle choice for each tissue application, and the use of B1 correction, are needed to improve the robustness of VFA protocols for T1 mapping. Magn Reson Med 79:2564-2575, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Encéfalo/diagnóstico por imagem , Mama/diagnóstico por imagem , Meios de Contraste/química , Feminino , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Masculino , Neoplasias/diagnóstico por imagem , Próstata/diagnóstico por imagem , Reprodutibilidade dos Testes
13.
Tomography ; 2(1): 56-66, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27200418

RESUMO

Dynamic contrast-enhanced MRI (DCE-MRI) has been widely used in tumor detection and therapy response evaluation. Pharmacokinetic analysis of DCE-MRI time-course data allows estimation of quantitative imaging biomarkers such as Ktrans(rate constant for plasma/interstitium contrast reagent (CR) transfer) and ve (extravascular and extracellular volume fraction). However, the use of quantitative DCE-MRI in clinical prostate imaging islimited, with uncertainty in arterial input function (AIF, i.e., the time rate of change of the concentration of CR in the blood plasma) determination being one of the primary reasons. In this multicenter data analysis challenge to assess the effects of variations in AIF quantification on estimation of DCE-MRI parameters, prostate DCE-MRI data acquired at one center from 11 prostate cancer patients were shared among nine centers. Each center used its site-specific method to determine the individual AIF from each data set and submitted the results to the managing center. Along with a literature population averaged AIF, these AIFs and their reference-tissue-adjusted variants were used by the managing center to perform pharmacokinetic analysis of the DCE-MRI data sets using the Tofts model (TM). All other variables including tumor region of interest (ROI) definition and pre-contrast T1 were kept the same to evaluate parameter variations caused by AIF variations only. Considerable pharmacokinetic parameter variations were observed with the within-subject coefficient of variation (wCV) of Ktrans obtained with unadjusted AIFs as high as 0.74. AIF-caused variations were larger in Ktrans than ve and both were reduced when reference-tissue-adjusted AIFs were used. The parameter variations were largely systematic, resulting in nearly unchanged parametric map patterns. The CR intravasation rate constant, kep (= Ktrans/ve), was less sensitive to AIF variation than Ktrans (wCV for unadjusted AIFs: 0.45 for kepvs. 0.74 for Ktrans), suggesting that it might be a more robust imaging biomarker of prostate microvasculature than Ktrans.

14.
Acad Radiol ; 22(3): 363-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25435183

RESUMO

RATIONALE AND OBJECTIVES: Magnetic resonance diffusion imaging can characterize physiologic characteristics of pediatric brain tumors used to assess therapy response. The purpose of this study was to assess the variability of the apparent diffusion coefficient (ADC) along z-axis of scanners in the multicenter Pediatric Brain Tumor Consortium (PBTC). MATERIALS AND METHODS: Ice-water diffusion phantoms for each PBTC site were distributed with a specific diffusion imaging protocol. The phantom was scanned four successive times to 1) confirm water in the tube reached thermal equilibrium and 2) allow for assessment of intra-examination ADC repeatability. ADC profiles across slice positions for each vendor and institution combination were characterized using linear regression modeling with a quadratic fit. RESULTS: Eleven sites collected data with a high degree of compliance to the diffusion protocol for each scanner. The mean ADC value at slice position zero for vendor A was 1.123 × 10(-3) mm(2)/s, vendor B was 1.0964 × 10(-3) mm(2)/s, and vendor C was 1.110 × 10(-3) mm(2)/s. The percentage coefficient of variation across all sites was 0.309% (standard deviation = 0.322). The ADC values conformed well to a second-order polynomial along the z-axis, (ie, following a linear model pattern with quadratic fit) for vendor-institution combinations and across vendor-institution combinations as shown in the longitudinal model. CONCLUSIONS: Assessment of the variability of diffusion metrics is essential for establishing the validity of using these quantitative metrics in multicenter trials. The low variability in ADC values across vendors and institutions and validates the use of ADC as a quantitative tumor marker in pediatric multicenter trials.


Assuntos
Neoplasias Encefálicas/diagnóstico , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Criança , Humanos , Gelo , Reprodutibilidade dos Testes , Água
15.
Transl Oncol ; 7(1): 65-71, 2014 02.
Artigo em Inglês | MEDLINE | ID: mdl-24772209

RESUMO

PURPOSE: To evaluate the ability of various software (SW) tools used for quantitative image analysis to properly account for source-specific image scaling employed by magnetic resonance imaging manufacturers. METHODS: A series of gadoteridol-doped distilled water solutions (0%, 0.5%, 1%, and 2% volume concentrations) was prepared for manual substitution into one (of three) phantom compartments to create "variable signal," whereas the other two compartments (containing mineral oil and 0.25% gadoteriol) were held unchanged. Pseudodynamic images were acquired over multiple series using four scanners such that the histogram of pixel intensities varied enough to provoke variable image scaling from series to series. Additional diffusion-weighted images were acquired of an ice-water phantom to generate scanner-specific apparent diffusion coefficient (ADC) maps. The resulting pseudodynamic images and ADC maps were analyzed by eight centers of the Quantitative Imaging Network using 16 different SW tools to measure compartment-specific region-of-interest intensity. RESULTS: Images generated by one of the scanners appeared to have additional intensity scaling that was not accounted for by the majority of tested quantitative image analysis SW tools. Incorrect image scaling leads to intensity measurement bias near 100%, compared to nonscaled images. CONCLUSION: Corrective actions for image scaling are suggested for manufacturers and quantitative imaging community.

16.
Transl Oncol ; 7(1): 153-66, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24772219

RESUMO

Pharmacokinetic analysis of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) time-course data allows estimation of quantitative parameters such as K (trans) (rate constant for plasma/interstitium contrast agent transfer), v e (extravascular extracellular volume fraction), and v p (plasma volume fraction). A plethora of factors in DCE-MRI data acquisition and analysis can affect accuracy and precision of these parameters and, consequently, the utility of quantitative DCE-MRI for assessing therapy response. In this multicenter data analysis challenge, DCE-MRI data acquired at one center from 10 patients with breast cancer before and after the first cycle of neoadjuvant chemotherapy were shared and processed with 12 software tools based on the Tofts model (TM), extended TM, and Shutter-Speed model. Inputs of tumor region of interest definition, pre-contrast T1, and arterial input function were controlled to focus on the variations in parameter value and response prediction capability caused by differences in models and associated algorithms. Considerable parameter variations were observed with the within-subject coefficient of variation (wCV) values for K (trans) and v p being as high as 0.59 and 0.82, respectively. Parameter agreement improved when only algorithms based on the same model were compared, e.g., the K (trans) intraclass correlation coefficient increased to as high as 0.84. Agreement in parameter percentage change was much better than that in absolute parameter value, e.g., the pairwise concordance correlation coefficient improved from 0.047 (for K (trans)) to 0.92 (for K (trans) percentage change) in comparing two TM algorithms. Nearly all algorithms provided good to excellent (univariate logistic regression c-statistic value ranging from 0.8 to 1.0) early prediction of therapy response using the metrics of mean tumor K (trans) and k ep (=K (trans)/v e, intravasation rate constant) after the first therapy cycle and the corresponding percentage changes. The results suggest that the interalgorithm parameter variations are largely systematic, which are not likely to significantly affect the utility of DCE-MRI for assessment of therapy response.

17.
Proteomics Clin Appl ; 5(7-8): 440-7, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21751409

RESUMO

PURPOSE: To demonstrate robust detection of biomarkers in broad-mass-range TOF-MS data. EXPERIMENTAL DESIGN: Spectra were obtained for two serum protein profiling studies: (i) 2-200 kDa for 132 patients, 67 healthy and 65 diagnosed as having adult T-cell leukemia and (ii) 2-100 kDa for 140 patients, 70 pairs, each with matched prostate-specific antigen (PSA) levels and biopsy-confirmed diagnoses of one benign and one prostate cancer. Signal processing was performed on raw spectra and peak data were normalized using four methods. Feature selection was performed using Bayesian Network Analysis and a classifier was tested on withheld data. Identification of candidate biomarkers was pursued. RESULTS: Integrated peak intensities were resolved over full spectra. Normalization using local noise values was superior to global methods in reducing peak correlations, reducing replicate variability and improving feature selection stability. For the leukemia data set, potential disease biomarkers were detected and were found to be predictive for withheld data. Preliminary assignments of protein IDs were consistent with published results and LC-MS/MS identification. No prostate-specific-antigen-independent biomarkers were detected in the prostate cancer data set. CONCLUSIONS AND CLINICAL RELEVANCE: Signal processing, local signal-to-noise (SNR) normalization and Bayesian Network Analysis feature selection facilitate robust detection and identification of biomarker proteins in broad-mass-range clinical TOF-MS data.


Assuntos
Biomarcadores/sangue , Proteínas Sanguíneas/análise , Leucemia-Linfoma de Células T do Adulto/diagnóstico , Hiperplasia Prostática/diagnóstico , Neoplasias da Próstata/diagnóstico , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Adulto , Algoritmos , Teorema de Bayes , Cromatografia de Afinidade , Feminino , Humanos , Leucemia-Linfoma de Células T do Adulto/sangue , Masculino , Antígeno Prostático Específico/sangue , Hiperplasia Prostática/sangue , Neoplasias da Próstata/sangue , Controle de Qualidade , Software
18.
BMC Bioinformatics ; 11: 177, 2010 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-20377906

RESUMO

BACKGROUND: Time-of-flight mass spectrometry (TOF-MS) has the potential to provide non-invasive, high-throughput screening for cancers and other serious diseases via detection of protein biomarkers in blood or other accessible biologic samples. Unfortunately, this potential has largely been unrealized to date due to the high variability of measurements, uncertainties in the distribution of proteins in a given population, and the difficulty of extracting repeatable diagnostic markers using current statistical tools. With studies consisting of perhaps only dozens of samples, and possibly hundreds of variables, overfitting is a serious complication. To overcome these difficulties, we have developed a Bayesian inductive method which uses model-independent methods of discovering relationships between spectral features. This method appears to efficiently discover network models which not only identify connections between the disease and key features, but also organizes relationships between features--and furthermore creates a stable classifier that categorizes new data at predicted error rates. RESULTS: The method was applied to artificial data with known feature relationships and typical TOF-MS variability introduced, and was able to recover those relationships nearly perfectly. It was also applied to blood sera data from a 2004 leukemia study, and showed high stability of selected features under cross-validation. Verification of results using withheld data showed excellent predictive power. The method showed improvement over traditional techniques, and naturally incorporated measurement uncertainties. The relationships discovered between features allowed preliminary identification of a protein biomarker which was consistent with other cancer studies and later verified experimentally. CONCLUSIONS: This method appears to avoid overfitting in biologic data and produce stable feature sets in a network model. The network structure provides additional information about the relationships among features that is useful to guide further biochemical analysis. In addition, when used to classify new data, these feature sets are far more consistent than those produced by many traditional techniques.


Assuntos
Espectrometria de Massas/métodos , Proteômica/métodos , Teorema de Bayes , Biomarcadores/química , Reconhecimento Automatizado de Padrão
19.
J Proteome Res ; 6(11): 4517-24, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17918874

RESUMO

Analysis of complex biological samples by MALDI-TOF mass spectrometry has been generally limited to the detection of low-mass protein (or protein fragment) peaks. We have extended the mass range of MALDI-TOF high-sensitivity detection by an order of magnitude through the combined optimization of instrument parameters, data processing, and sample preparation procedures for affinity capture. WCX, C3, and IMAC magnetic beads were determined to be complementary and most favorable for broad mass range protein profiling. Key instrument parameters for extending mass range included adjustment of the ADC offset and preamplifier filter values of the TOF detector. Data processing was improved by a combination of constant and quadratic down-sampling, preceded by exponential baseline subtraction, to increase sensitivity of signal peaks. This enhancement in broad mass range detection of protein signals will be of direct benefit in MS expression profiling studies requiring full linear range mass detection.


Assuntos
Proteômica/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Proteínas Sanguíneas/química , Calibragem , Humanos , Magnetismo , Espectrometria de Massas , Peso Molecular , Mapeamento de Peptídeos , Peptídeos/química , Análise Serial de Proteínas , Proteínas/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Rapid Commun Mass Spectrom ; 20(11): 1670-8, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16637003

RESUMO

We have developed a peak deconvolution strategy that is applicable to the full mass range of a time-of-flight (TOF) spectrum. This strategy involves resampling a spectrum to create a time series that has equal peak widths (in time) across the entire spectrum, and then using the deconvolution filters we have previously described. We use this technique to deconvolve the protein mass spectra for blood serum and cell lysates acquired on three separate TOF instruments. Following deconvolution, we resolve spectral structures consistent with expected events such as multiply charged ions, matrix adducts and post-translational protein modifications. The deconvolution procedure produces a 40% improvement in the resolution and enhanced experimental sensitivity over the full length of the linear TOF record, up to m/z 150 000. This approach is particularly appropriate for automated data analysis and peak detection in dense TOF spectra.


Assuntos
Algoritmos , Proteínas/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/estatística & dados numéricos , Apolipoproteína A-I/análise , Líquidos Corporais/química , Calibragem , Interpretação Estatística de Dados , Entropia , Células Epiteliais/química , Humanos , Dinâmica não Linear , Processamento de Proteína Pós-Traducional , Soro/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos