1.
Phys Med ; 30(1): 2-9, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23116552

RESUMO

PURPOSE: To investigate the performances of two commercial treatment planning systems (TPS) for Volumetric Modulated Arc Therapy (VMAT) optimization regarding prostate cancer. The TPS were compared in terms of dose distributions, treatment delivery parameters and quality control results. MATERIALS AND METHODS: For ten patients, two VMAT plans were generated: one with Monaco TPS (Elekta) and one with Pinnacle TPS (Philips Medical Systems). The total prescribed dose was 78 Gy delivered in one 360° arc with a Synergy(®) linear accelerator equipped with a MLCi2(®). RESULTS: VMAT with Monaco provided better homogeneity and conformity indexes but lower mean dose to PTVs than Pinnacle. For the bladder wall (p = 0.019), the femoral heads (p = 0.017), and healthy tissues (p = 0.005), significantly lower mean doses were found using Monaco. For the rectal wall, VMAT with Pinnacle provided a significantly (p = 0.047) lower mean dose, and lower dose into 50% of the volume (p = 0.047) compared to Monaco. Despite a greater number of monitor units (factor 1.5) for Monaco TPS, the total treatment time was equivalent to that of Pinnacle. The treatment delivery parameter analysis showed larger mean MLC area for Pinnacle and lower mean dose rate compared to Monaco. The quality control results gave a high passing rate (>97.4%) for the gamma index for both TPS but Monaco provided slightly better results. CONCLUSION: For prostate cancer patients, VMAT treatment plans obtained with Monaco and Pinnacle offered clinically acceptable dose distributions. Further investigations are in progress to confirm the performances of the two TPS for irradiating more complex volumes.


Assuntos
Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Masculino , Garantia da Qualidade dos Cuidados de Saúde , Radiometria , Dosagem Radioterapêutica
2.
J Appl Clin Med Phys ; 14(6): 4074, 2013 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-24257269

RESUMO

This dosimetric study investigated the impact of multileaf collimators (MLC) leaf width in volumetric-modulated arc therapy (VMAT) for head and neck cancers (HNC), either with a "standard" simultaneously integrated boost technique (S-SIB) or with a "dose painting" SIB technique (DP-SIB). HNC patients were planned either with an S-SIB comprising three dose levels, from 56 to 70 Gy (16 patients), or with a DP-SIB comprising five dose levels, from 56 to 84 Gy (8 patients), in 35 fractions. Two VMAT plans were calculated for each SIB technique using two Elekta MLCs: MLCi2 with 10 mm leaf width and Beam Modulator (BM) with 4 mm leaf width. Dose distributions were evaluated by comparing doses on PTVs, main OARs, and healthy tissue, and by comparing conformation indexes. Treatment efficiencies were evaluated by comparing the number of monitor units and the number of needed arcs. Comparisons of the two MLCs depending on the two SIB techniques showed: i) Regarding PTVs: Dmean and D2% on lower doses PTV decreased respectively by 0.5 Gy (p = 0.01) and 0.9 Gy (p = 0.01) with BM than with MLCi2 for S-SIB; no significant difference was found for DP-SIB;ii) Regarding OARs: for spinal cord and brainstem, D2% decreased respectively by 1.2 Gy (p = 0.03) and 4.2 Gy (p = 0.04) with BM than with MLCi2 for S-SIB; for controlateral parotid, D50% decreased by 1.5 Gy (p = 0.01) with BM than with MLCi2 for S-SIB; iii) Regarding treatment efficiency: the number of monitor units was 44% (p = 0.00) and 51% (p = 0.01) higher with BM for S-SIB and DP-SIB, respectively. Two arcs were more frequently needed with BM to reach an acceptable dose distribution. This study demonstrated that Beam Modulator (4 mm leaf width) and MLCi2 (10 mm leaf width) MLCs from Elekta provided satisfactory dose distributions for treatment delivery with VMAT technique for complex HNC cases with standard and dose painting prescriptions. OAR sparing was better with BM, mainly for brainstem and spinal cord. However, delivery efficiency of VMAT plans was better with MLCi2.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Estadiamento de Neoplasias , Prognóstico , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X
3.
Radiat Oncol ; 8: 132, 2013 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-23721062

RESUMO

BACKGROUND: The objective was to analyze locoregional (LR) failure patterns in patients with head-and-neck cancer (HNC) treated using intensity-modulated radiotherapy (IMRT) with whole salivary gland-sparing: parotid (PG), submandibular (SMG), and accessory salivary glands represented by the oral cavity (OC). METHODS: Seventy consecutive patients with Stage I-II (23%) or III/IV (77%) HNC treated by definitive IMRT were included. For all LR failure patients, the FDG-PET and CT scans documenting recurrence were rigidly registered to the initial treatment planning CT. Failure volumes (Vf) were delineated based on clinical, radiological, and histological data. The percentage of Vf covered by 95% of the prescription isodose (Vf-V95) was analyzed. Failures were classified as "in-field" if Vf-V95 ≥ 95%, "marginal" if 20% < Vf-V95 < 95%, and "out-of-field" if Vf-V95 ≤20%. Correlation between Vf-V95 and mean doses (Dmean) in the PG, SMG, and OC was assessed using Spearman's rank-order correlation test. The salivary gland dose impact on the LR recurrence risk was assessed by Cox analysis. RESULTS: The median follow-up was 20 months (6-35). Contralateral and ipsilateral PGs were spared in 98% and 54% of patients, respectively, and contralateral and ipsilateral SMG in 26% and 7%, respectively. The OC was spared to a dose ≤40 Gy in 26 patients (37%). The 2-year LR control rate was 76.5%. One recurrence was "marginal", and 12 were "in-field". No recurrence was observed in vicinity of spared structures. Vf-V95 was not significantly correlated with Dmean in PG, SMG, and OC. The LR recurrence risk was not increased by lower Dmean in the salivary glands, but by T (p = 0.04) and N stages (p = 0.03). CONCLUSION: Over 92% of LR failures occurred "in-field" within the high dose region when using IMRT with a whole salivary gland-sparing strategy. Sparing SMG and OC in addition to PG thus appears a safe strategy.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Glândula Parótida , Radioterapia de Intensidade Modulada/métodos , Glândulas Salivares , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/epidemiologia , Órgãos em Risco , Glândula Parótida/efeitos da radiação , Radiometria , Radioterapia de Intensidade Modulada/efeitos adversos , Glândulas Salivares/efeitos da radiação , Xerostomia/etiologia , Xerostomia/prevenção & controle
4.
Comput Med Imaging Graph ; 31(6): 401-7, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17574815

RESUMO

This work deals with the treatment planning optimization for intravascular brachytherapy (IVB) in peripheral arteries. The objective is both to quantitatively study the validity of different hypotheses required for a reliable application of the treatment with current techniques, and to contribute to the definition and the specification of a new optimized procedure taking into account the actual patient's vessel geometry. The detection of vascular luminal surface was performed by an image analysis process, i.e., virtual active navigation, applied to standard CT data. Dose distribution was calculated according to the formalism proposed and recommended by the AAPM in TG43 and TG60. A method combining simulated annealing and BFGS algorithms was applied to optimize the parameters associated with the dwell points such as their number, positions, and dwell times. Dose-surface histogram (DSH) was used to evaluate the dose distribution results. Four levels of accuracy in target surface description were tested. The application of this optimization method to four different CT data sets including patient data, phantom and animal models showed that the treatment plan can be improved when the actual vessel geometry has been taken into account.


Assuntos
Angiografia/métodos , Artérias/efeitos da radiação , Braquiterapia/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/radioterapia , Simulação por Computador , Análise de Elementos Finitos , Humanos , Modelos Biológicos , Radiometria/métodos , Dosagem Radioterapêutica , Eficiência Biológica Relativa
5.
Conf Proc IEEE Eng Med Biol Soc ; 2005: 2316-8, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-17282698

RESUMO

A two-step method to determine the seed parameters for the planning of peripheral intravascular brachytherapy, which took the actual vessel geometry into consideration, was developed. Firstly, the characteristics of the vessel geometry was obtained by using active navigation; Then a method combined genetic algorithm with BFGS algorithm was applied to optimize the number of seeds, and the parameters associated with each seed such as the position, and the dwell time. Application of the method to a phantom model and three animal models of stenosis shows that promising result could be obtained, and the planning of peripheral intravascular brachytherapy should take actual vessel geometry into consideration.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA