Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Insights Imaging ; 15(1): 135, 2024 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-38853199

RESUMO

OBJECTIVES: To compare the magnetic resonance imaging (MRI) and Doppler ultrasound (DUS) findings with the pathological findings of soft tissue vascular tumors (STVTs) according to the 2018 ISSVA (International Society for the Study of Vascular Anomalies) classification to differentiate vascular tumors from vascular malformations. METHODS: This retrospective study included patients with STVTs who underwent contrast-enhanced MRI and pathological analysis at our hospital between 2010 and 2020. The presumptive diagnosis based on the on-site imaging and histological analysis was compared with imaging and histological analysis conducted off-site utilizing the ISSVA criteria. RESULTS: This study included 31 patients with 31 vascular tumors located in the head and neck (n = 3), trunk (n = 2), and extremities (n = 26). The off-site pathological analysis confirmed benign vascular tumors in 54.8% of cases (non-involuting congenital hemangioma: 35.5%; epithelioid hemangioma: 13%; pyogenic granuloma: 3%; and spindle cell hemangioma: 3%). Based on the off-site histological analysis, 25.8% were reclassified as having a vascular malformation whereas three had other benign lesions. Only phleboliths were associated with a vascular malformation (p = 0.03). The concordance between off-site MRI and pathological findings was fair (k = 0.3902 (0.0531-0.7274)), whereas that between on-site and off-site pathological analyses was poor (k = -0.0949 (-0.4661 to 0.2763)). CONCLUSION: Benign vascular tumors have non-specific imaging features on imaging with some overlap with atypical vascular malformations. Therefore, histological analysis is recommended. Imaging and pathological analyses should be performed in accordance with the ISSVA classification to minimize inter-observer discrepancies. CRITICAL RELEVANCE STATEMENT: Imaging features of benign vascular tumors on MRI are non-specific, leading to discrepancies with pathological findings and potential overlap with atypical vascular malformations. Imaging and histological analyses should be performed in accordance with ISSVA guidelines to improve patient management. KEY POINTS: The imaging features of benign vascular tumors are non-specific. Histological analysis is recommended for soft tissue vascular tumors in adults. Analyses of soft tissue vascular tumors should be performed in accordance with ISSVA guidelines.

2.
Eur Radiol ; 32(7): 4679-4686, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35137302

RESUMO

OBJECTIVES: To prospectively evaluate the safety and efficacy of embolization using ethylene vinyl alcohol copolymer (Onyx®) and Aetoxysclerol for treatment of pelvic venous disorders (PeVD). METHODS: This prospective study was approved by the institutional ethics review board. Ten clinical parameters were retained for evaluation of PeVD (pelvic pain, dyspareunia, post-coital pain, menstruation pain, lower limbs pain, difficulty walking, aesthetic discomfort, impact on daily working life, psychological impact and impact on daily life), measured on a visual analogue scale (VAS) between 0 and 10, and a global score out of 100 was noted before embolization, after 3 months during the imaging follow-up, and at the end of follow-up by phone call. The main criterion was clinical efficacy of embolization defined by an impairment score < 40/100 and a 50% decrease in overall score. Complications were recorded. Visualization of Onyx® on MRI 3 months after embolization was noted. RESULTS: Between July 2017 and May 2019, 73 consecutive women (mean age ± SD [range]: 41 ± 11 years [25-77]) treated by embolization with Onyx® and Aetoxysclerol were included. The median follow-up was 28 months [Q1-Q3: 24.0-29.2] (range: 18.1-34.5). The median initial VAS impairment score was 39/100 [29.75-48.50] (12-58). Clinical efficacy was obtained for 70 patients (70/73, 95.9%), and the median VAS impairment score at the end of follow-up was significantly lower at 3 [0.00-7.25] (0-73) (p < 0.0001). Four minor complications occurred. Onyx® was visualized on DIXON sequence of MRI for all patients. CONCLUSION: Embolization using Onyx® and Aetoxysclerol for PeVD is safe and effective. KEY POINTS: • Embolization using Onyx® and Aetoxysclerol for pelvic venous disorders is safe and effective. • Imaging follow-up is facilitated by visualization of Onyx® on MRI DIXON sequences.


Assuntos
Embolização Terapêutica , Doenças Vasculares , Dimetil Sulfóxido/uso terapêutico , Embolização Terapêutica/métodos , Feminino , Humanos , Dor/tratamento farmacológico , Polivinil/uso terapêutico , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
5.
Diagn Interv Imaging ; 99(1): 3-8, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29066127

RESUMO

PURPOSE: To compare diameters of in vivo microwave ablation (MWA) performed in swine kidneys with ex vivo diameters, and to correlate with ablation work (AW), a new metric reflecting total energy delivered. MATERIAL AND METHODS: Eighteen in vivo MWA were performed in 6 swine kidneys successively using one or two antennas (MicroThermX®). Ablation consisted in delivering power (45-120W) for 5-15minutes. Ex vivo diameters were provided by the vendors and obtained on bovine liver tissue. AW was defined as the sum of (power)*(time)*(number of antennas) for all phases of an ablation (in kJoules). Kidneys were removed laparoscopically immediately after ablation. After sacrifice, ablations zones were evaluated macroscopically, and maximum diameters of the zones were recorded. Wilcoxon sum rank test and Pearson's correlation were used for comparisons. RESULTS: For a single antenna (n=12), the in vivo diameters ranged from 12 to 35mm, and 15-49mm for 2 antennas (n=6). The in vivo diameters remained shorter than ex vivo diameters by 8.6%±30.1 on 1 antenna and 11.7%±26.5 on 2 antennas (P=0.31 and 0.44, respectively). AW ranged from 13.5 to 108kJ. Diameters increased linearly with AW both with 1 and 2 antennas, but only moderate correlations were observed (r=0.43 [95% confidence interval: -0.19; 0.81], P=0.16; and 0.57 [-0.44; 0.95], P=0.24, respectively). CONCLUSION: Although diameters after in vivo renal MWA increased linearly with AW, the moderate correlation and wide standard deviations observed may justify a careful imaging monitoring during treatment delivery and settings adaptation, if needed, for optimal ablation.


Assuntos
Técnicas de Ablação/instrumentação , Rim/cirurgia , Micro-Ondas , Técnicas de Ablação/métodos , Animais , Bovinos , Rim/patologia , Fígado/cirurgia , Modelos Animais , Nefrectomia , Suínos
6.
Diagn Interv Imaging ; 98(9): 589-599, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28844612

RESUMO

Percutaneous image-guided biopsies help better select patients with renal tumors smaller than 4cm. These biopsies are performed to reduce the risks of overtreatment and to discriminate between patients who need ablation therapy and those who require active surveillance. Percutaneous image-guided biopsies are effective for a definitive diagnosis with little risk of complications when cautions are observed. With the current addition of multiparametric imaging, standardized biopsy protocols may further help adapt therapeutic decisions. The aim of this review is to report the current indications and techniques of biopsy performed in case of small solid renal masses and to clarify the optimal conditions for the realization of these biopsies.


Assuntos
Biópsia por Agulha/métodos , Biópsia Guiada por Imagem , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Técnicas de Ablação , Biópsia por Agulha/efeitos adversos , Humanos , Consentimento Livre e Esclarecido , Neoplasias Renais/cirurgia , Inoculação de Neoplasia , Prognóstico , Conduta Expectante
7.
Diagn Interv Imaging ; 98(12): 843-848, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28647478

RESUMO

PURPOSE: To evaluate the safety and efficacy of pelvic embolization using ethylene vinyl alcohol copolymer (Onyx®) for pelvic congestion syndrome. MATERIAL AND METHODS: Between March 2012 to September 2016, 17 women (mean age, 44.7± 12.2 (SD) years; range: 34-71years) presenting with pelvic congestion syndrome were evaluated for transvenous embolization with Onyx®. Pelvic congestion syndrome was initially diagnosed by clinical examination and the results of transvaginal Doppler ultrasound and further confirmed by pelvic venography. Primary and secondary clinical efficacy was defined respectively by the resolution of the symptoms after embolization and at the end of the follow-up, irrespective to the number of embolization procedures. RESULTS: Technical efficacy of embolization was 100% with no significant complications during and after embolization. After a mean follow-up time of 24.2 months (range: 6-69months) a primary and secondary clinical efficacy of 76.4% (13/17 women) and 94.1% (16/17 women) respectively were observed. Four women (23.5%) underwent a second embolization procedure with one woman requiring a third embolization procedure. These additional embolization procedures were associated with direct puncture of vulvar varices for sclerotherapy in two women. Five women (29%) had recurrent symptoms 21 months post-treatment (7-42months). CONCLUSION: Pelvic embolization using ethylene vinyl alcohol copolymer (Onyx®) has a favorable clinical success for pelvic congestion syndrome.


Assuntos
Quimioembolização Terapêutica , Ovário/irrigação sanguínea , Polivinil/administração & dosagem , Varizes/terapia , Veias , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Pelve/irrigação sanguínea , Síndrome , Resultado do Tratamento
8.
Diagn Interv Imaging ; 98(4): 287-297, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28011104

RESUMO

PURPOSE: The purpose of this review was to identify the specific technical considerations to adequately perform microwave ablations (MWA) of renal tumors and analyze the currently available clinical results. METHODS: Using Medline, a systematic review was performed including articles published between January 2000 and September 2016. English language original articles, reviews and editorials were selected based on their clinical relevance. RESULTS: MWA has several theoretical advantages over radiofrequency ablation in consistently providing higher intratumoral temperatures. MWA is less dependent of electrical conductivities of tissues and the delivered energy is less limited by desiccation of heated tissues. While there are insufficient data, especially because of a lack of studies with mid- to long-term follow-up, to determine the oncologic effectiveness of MWA, this technique appears safe and effective for the ablation of T1 renal tumors. There is evidence for using mid-level settings based on experimental and clinical data. Power set at 50-65W for 5-15min appears adequate in kidney but close clinical and imaging follow-up have to be performed. CONCLUSION: Renal MWA offers theoretical advantages by comparison with other available techniques to treat renal tumors. However, MWA suffers of less cumulative data compared to radiofrequency ablation or cryoablation. Moreover, microwaves still require further studies to identify the optimal tumor characteristics and device settings leading to predictable ablation.


Assuntos
Técnicas de Ablação/métodos , Neoplasias Renais/cirurgia , Micro-Ondas/uso terapêutico , Técnicas de Ablação/instrumentação , Idoso , Animais , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/patologia , Carcinoma de Células Renais/cirurgia , Humanos , Rim/patologia , Rim/cirurgia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Masculino , Necrose , Estadiamento de Neoplasias , Suínos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA