Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Urol Int ; 101(1): 106-113, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29953998

RESUMO

OBJECTIVES: Feasibility study to evaluate the efficacy and safety of Adjustable Transobturator Male System (ATOMS) after failed surgical devices for male stress urinary incontinence (SUI). MATERIALS AND METHODS: Thirty patients were implanted with ATOMS after they were implanted with surgical device/s previously. SUI severity was evaluated as dryness (0-1 pad/day), mild (2 pads/day), moderate (3-5 pads/day), or severe (≥6 pads/day). Change in pad-test and pad-count after adjustment, operative parameters, patient satisfaction, and number and grade of complications were investigated. RESULTS: Previous failed treatment methods were artificial urinary sphincter (AUS; n = 19), Advance (n = 10), and Virtue (n = 1). Six cases had multiple previous treatments. Preoperative SUI was mild 6 (20%), moderate 11 (36.7%), and severe 13 (43.3%). Median pad-test decreased from 435 mL baseline to 10 mL after adjustment and pad-count from 4 to 0. Dry-rate was 76.7 and 83.3% declared satisfied. Postoperative SUI distribution was mild in 3 (10%) and moderate in 4 (13.3%). No patient had urinary retention after catheter removal. Complications presented in 4 (13.3%; 3 grade-I, 1 grade-II). After a median of 24 months follow-up, no system experienced infection or urethral erosion and 1 (3.3%) was removed for inefficacy. CONCLUSION: Based on short-term efficacy and patient satisfaction, ATOMS can be a realistic alternative for male SUI after other failed systems, including AUS. The absence of urethral erosion and limited infective problems makes this alternative attractive for cases with previous failed treatments.


Assuntos
Prostatectomia/efeitos adversos , Slings Suburetrais/efeitos adversos , Incontinência Urinária por Estresse/cirurgia , Esfíncter Urinário Artificial/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Desenho de Prótese , Resultado do Tratamento
2.
Neurourol Urodyn ; 37(4): 1458-1466, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29315765

RESUMO

AIM: To evaluate effectiveness and safety of the adjustable transobturator male system (ATOMS) for male stress urinary incontinence (SUI). MATERIAL AND METHODS: A retrospective multicenter study was conducted in nine Iberian institutions using a board-approved database for 215 patients intervened between 2012 and 2017, with no case excluded. Continence status, patient satisfaction, number, and grade of complications (Clavien-Dindo) and factors affecting dry rate at adjustment were evaluated. Multivariate analysis defined the population at best success rate. Incontinence recurrence due to device failure and/or explant was evaluated and Kaplan-Meier curve for durability performed. RESULTS: Adjustment was achieved at a mean 1.4 ± 1.9 fillings. Dry-rate after adjustment was 80.5% (96.2% mild and 75.3% moderate-severe), 121 (56.3%) used no pads, and 52 (24.2%) a security pad with urine loss under 10 mL. Mean basal daily pad-test and pad-count decreased from 484 ± 372.3 mL and 3.9 ± 2 pads to 63.5 ± 201.2 mL and 0.9 ± 1.5pads (both P < 0.0001). Satisfaction rate was 85.1% (94.3% mild and 82.1% moderate-severe). Factors associated to dryness were: lesser severity of SUI (P < .0001), absence of radiotherapy (P = 0.0002) and device generation (P = 0.05). Multivariate analysis revealed absence of radiation (OR = 3.12; 1.36-7.19), mild (OR = 19.61; 3.95-100), and moderate (OR = 2.48; 1.1-5.59) SUI were independent predictors. Complications presented in 33(15.35%); 66.7% grade 1, 9.1% grade 2, and 24.2% grade 3. At 24.3 ± 15 mo mean follow-up device was explanted in seven (3.25%) and SUI worsened after adjustment in nine (4.2%). Dry-rate at follow-up was 73% and durability of device in dry patients at adjustment was 89.8% (82.9-94) at 2-years. CONCLUSIONS: This study confirms ATOMS device is safe and achieves high treatment efficacy and patient satisfaction in a multicenter setting. Significantly better results are achieved in less severe and non-irradiated cases. Durability of the device is reassuring in the short-term.


Assuntos
Satisfação do Paciente , Prostatectomia/efeitos adversos , Slings Suburetrais , Incontinência Urinária por Estresse/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Recidiva , Estudos Retrospectivos , Espanha , Resultado do Tratamento , Incontinência Urinária por Estresse/etiologia
3.
Adv Ther ; 34(5): 1173-1183, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28405960

RESUMO

INTRODUCTION: The objective of this study was to report outcome measures with third-generation pre-attached scrotal port adjustable transobturator male system (ATOMS) for male stress urinary incontinence (SUI) after radical prostatectomy. METHODS: A prospective open study was conducted on consecutive patients. Evaluation included cough test, urethroscopy, filling and voiding cystometry, 24-h pad count and pad test, patient-reported outcomes (ICIQ-SF, IIQ-7, PGI, GRA, and VAS), complications according to the Clavien-Dindo system, operative results, number of adjustments, and filling of the system. RESULTS: Thirty-four patients with median pad test 510 (170-1225) ml were operated on. Preoperative SUI was mild (5.9%), moderate (17.6%), and severe (76.5%). At median 18.5 (12-26) months follow-up distribution of SUI was none (85.3%), mild (8.8%), and moderate (5.9%). Median intraoperative filling was 14 (8-17) ml, number of adjustments 1 (0-5), and total filling 17.5 (11-33.5) ml. At 3 months, median ICIQ-SF (p = 0.0001) and IIQ-7 (p < 0.0001) decreased. At 12 months, 24-h pad count and pad test decreased (both p < 0.0001), residual volume slightly increased (p = 0.018), PGI-I was 1 (1-3), GRA 6 (3-6), and 97% were satisfied with treatment. Continence (p = 0.016) and satisfaction (p = 0.09) were worse in irradiated patients. Median operative time was 67 (35-120) min, hospital stay 1 (1-3) days, and VAS for pain on postoperative day 1 was 0 (0-2). Complications presented in 14.7% (8.8% grade I and 5.9% grade III). CONCLUSION: Treatment of severe male SUI after radical prostatectomy with pre-attached scrotal port ATOMS is safe and very effective in the short term. A positive cough test before implant and intraoperative overfilling of the system may optimize patient selection and results.


Assuntos
Prostatectomia/métodos , Slings Suburetrais , Incontinência Urinária por Estresse/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA