Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Neurointerv Surg ; 12(3): 266-270, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31350369

RESUMO

INTRODUCTION: Multiple randomized trials have shown that endovascular thrombectomy (EVT) leads to improved outcomes in acute ischemic stroke (AIS) due to large vessel occlusion (LVO). Elderly patients were poorly represented in these trials, and the efficacy of EVT in nonagenarian patients remains uncertain. METHODS: We performed a retrospective cohort study at a single center. Inclusion criteria were: age 80-99, LVO, core infarct <70 mL, and salvageable penumbra. Patients were stratified into octogenarian (80-89) and nonagenarian (90-99) cohorts. The primary outcome was the ordinal score on the modified Rankin Scale (mRS) at 90 days. Secondary outcomes included dichotomized functional outcome (mRS ≤2 vs mRS ≥3), successful revascularization, symptomatic intracranial hemorrhage (ICH), and mortality. RESULTS: 108 patients met the inclusion criteria, including 79 octogenarians (73%) and 29 nonagenarians (27%). Nonagenarians were more likely to be female (86% vs 58%; p<0.01); there were no other differences between groups in terms of demographics, medical comorbidities, or treatment characteristics. Successful revascularization (TICI 2b-3) was achieved in 79% in both cohorts. Median mRS at 90 days was 5 in octogenarians and 6 in nonagenarians (p=0.09). Functional independence (mRS ≤2) at 90 days was achieved in 12.5% and 19.7% of nonagenarians and octogenarians, respectively (p=0.54). Symptomatic ICH occurred in 21.4% and 6.4% (p=0.03), and 90-day mortality rate was 63% and 40.9% (p=0.07) in nonagenarians and octogenarians, respectively. CONCLUSIONS: Nonagenarians may be at higher risk of symptomatic ICH than octogenarians, despite similar stroke- and treatment-related factors. While there was a trend towards higher mortality and worse functional outcomes in nonagenarians, the difference was not statistically significant in this relatively small retrospective study.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/cirurgia , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Trombectomia/métodos , Fatores Etários , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Trombectomia/tendências , Resultado do Tratamento
2.
Eur Radiol ; 29(7): 3506-3515, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30903333

RESUMO

BACKGROUND: International dose reference levels are lacking for mechanical thrombectomy in acute ischemic stroke patients with large vessel occlusions. We studied whether radiation dose-reduction systems (RDS) could effectively reduce exposure and propose achievable levels. MATERIALS AND METHODS: We retrospectively included consecutive patients treated with thrombectomy on a biplane angiography system (BP) in five international, high-volume centers between January 2014 and May 2017. Institutional Review Board approvals were obtained. Technical, procedural, and clinical characteristics were assessed. Efficacy, safety, radiation dose, and contrast load were compared between angiography systems with and without RDS. Multivariate analyses were adjusted according to Bonferroni's correction. Proposed international achievable cutoff levels were set at the 75th percentile. RESULTS: Out of the 1096 thrombectomized patients, 520 (47%) were treated on a BP equipped with RDS. After multivariate analysis, RDS significantly reduced dose-area product (DAP) (91 vs 140 Gy cm2, relative effect 0.74 (CI 0.66; 0.83), 35% decrease, p < 0.001) and air kerma (0.46 vs 0.97 Gy, relative effect 0.63 (CI 0.56; 0.71), 53% decrease, p < 0.001) with 75th percentile levels of 148 Gy cm2 and 0.73 Gy, respectively. There was no difference in contrast load, rates of successful recanalization, complications, or clinical outcome. CONCLUSION: Radiation dose-reduction systems can reduce DAP and air kerma by a third and a half, respectively, without affecting thrombectomy efficacy or safety. The respective thresholds of 148 Gy cm2 and 0.73 Gy represent achievable levels that may serve to optimize current and future radiation exposure in the setting of acute ischemic stroke treatment. As technology evolves, we expect these values to decrease. KEY POINTS: • Internationally validated achievable levels may help caregivers and health authorities better assess and reduce radiation exposure of both ischemic stroke patients and treating staff during thrombectomy procedures. • Radiation dose-reduction systems can reduce DAP and air kerma by a third and a half, respectively, without affecting thrombectomy efficacy or safety in the setting of acute ischemic stroke due to large vessel occlusion.


Assuntos
Isquemia Encefálica/cirurgia , Artéria Carótida Interna/cirurgia , Fluoroscopia/métodos , Exposição à Radiação/normas , Lesões por Radiação/prevenção & controle , Cirurgia Assistida por Computador/métodos , Trombectomia/métodos , Doença Aguda , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/diagnóstico , Artéria Carótida Interna/diagnóstico por imagem , Feminino , Humanos , Isquemia , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA