1.
BJR Open ; 6(1): tzae006, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38737623

RESUMO

Objectives: We validated an auto-contouring algorithm for heart substructures in lung cancer patients, aiming to establish its accuracy and reliability for radiotherapy (RT) planning. We focus on contouring an amalgamated set of subregions in the base of the heart considered to be a new organ at risk, the cardiac avoidance area (CAA), to enable maximum dose limit implementation in lung RT planning. Methods: The study validates a deep-learning model specifically adapted for auto-contouring the CAA (which includes the right atrium, aortic valve root, and proximal segments of the left and right coronary arteries). Geometric, dosimetric, quantitative, and qualitative validation measures are reported. Comparison with manual contours, including assessment of interobserver variability, and robustness testing over 198 cases are also conducted. Results: Geometric validation shows that auto-contouring performance lies within the expected range of manual observer variability despite being slightly poorer than the average of manual observers (mean surface distance for CAA of 1.6 vs 1.2 mm, dice similarity coefficient of 0.86 vs 0.88). Dosimetric validation demonstrates consistency between plans optimized using auto-contours and manual contours. Robustness testing confirms acceptable contours in all cases, with 80% rated as "Good" and the remaining 20% as "Useful." Conclusions: The auto-contouring algorithm for heart substructures in lung cancer patients demonstrates acceptable and comparable performance to human observers. Advances in knowledge: Accurate and reliable auto-contouring results for the CAA facilitate the implementation of a maximum dose limit to this region in lung RT planning, which has now been introduced in the routine setting at our institution.

2.
Front Oncol ; 12: 934369, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35928875

RESUMO

Radiation-induced heart disease (RIHD) is a recent concern in patients with lung cancer after being treated with radiotherapy. Most of information we have in the field of cardiac toxicity comes from studies utilizing real-world data (RWD) as randomized controlled trials (RCTs) are generally not practical in this field. This article is a narrative review of the literature using RWD to study RIHD in patients with lung cancer following radiotherapy, summarizing heart dosimetric factors associated with outcome, strength, and limitations of the RWD studies, and how RWD can be used to assess a change to cardiac dose constraints.

3.
Radiother Oncol ; 163: 68-75, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34343544

RESUMO

PURPOSE: Cone beam CT (CBCT) is used in paediatric image-guided radiotherapy (IGRT) for patient setup and internal anatomy assessment. Adult CBCT protocols lead to excessive doses in children, increasing the risk of radiation-induced malignancies. Reducing imaging dose increases quantum noise, degrading image quality. Patient CBCTs also include 'anatomical noise' (e.g. motion artefacts), further degrading quality. We determine noise contributions in paediatric CBCT, recommending practical imaging protocols and thresholds above which increasing dose yields no improvement in image quality. METHODS AND MATERIALS: Sixty CBCTs including the thorax or abdomen/pelvis from 7 paediatric patients (aged 6-13 years) were acquired at a range of doses and used to simulate lower dose scans, totalling 192 scans (0.5-12.8 mGy). Noise measured in corresponding regions of each patient and a 10-year-old phantom were compared, modelling total (including anatomical) noise, and quantum noise contributions as a function of dose. Contrast-to-noise ratio (CNR) was measured between fat/muscle. Soft tissue registration was performed on the kidneys, comparing accuracy to the highest dose scans. RESULTS: Quantum noise contributed <20% to total noise in all cases, suggesting anatomical noise is the largest determinant of image quality in the abdominal/pelvic region. CNR exceeded 3 in over 90% of cases ≥ 1 mGy, and 57% of cases at 0.5 mGy. Soft tissue registration was accurate for doses > 1 mGy. CONCLUSION: Anatomical noise dominates quantum noise in paediatric CBCT. Appropriate soft tissue contrast and registration accuracy can be achieved for doses as low as 1 mGy. Increasing dose above 1 mGy holds no benefit in improving image quality or registration accuracy due to the presence of anatomical noise.


Assuntos
Radioterapia Guiada por Imagem , Artefatos , Criança , Tomografia Computadorizada de Feixe Cônico , Humanos , Imagens de Fantasmas
4.
Int J Radiat Oncol Biol Phys ; 82(3): e375-82, 2012 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-22197229

RESUMO

PURPOSE: Parotid-sparing head-and-neck intensity-modulated radiotherapy (IMRT) can reduce long-term xerostomia. However, patients frequently experience weight loss and tumor shrinkage during treatment. We evaluate the use of kilovoltage (kV) cone beam computed tomography (CBCT) for dose monitoring and examine if the dosimetric impact of such changes on the parotid and critical neural structures warrants replanning during treatment. METHODS AND MATERIALS: Ten patients with locally advanced oropharyngeal cancer were treated with contralateral parotid-sparing IMRT concurrently with platinum-based chemotherapy. Mean doses of 65 Gy and 54 Gy were delivered to clinical target volume (CTV)1 and CTV2, respectively, in 30 daily fractions. CBCT was prospectively acquired weekly. Each CBCT was coregistered with the planned isocenter. The spinal cord, brainstem, parotids, larynx, and oral cavity were outlined on each CBCT. Dose distributions were recalculated on the CBCT after correcting the gray scale to provide accurate Hounsfield calibration, using the original IMRT plan configuration. RESULTS: Planned contralateral parotid mean doses were not significantly different to those delivered during treatment (p > 0.1). Ipsilateral and contralateral parotids showed a mean reduction in volume of 29.7% and 28.4%, respectively. There was no significant difference between planned and delivered maximum dose to the brainstem (p = 0.6) or spinal cord (p = 0.2), mean dose to larynx (p = 0.5) and oral cavity (p = 0.8). End-of-treatment mean weight loss was 7.5 kg (8.8% of baseline weight). Despite a ≥10% weight loss in 5 patients, there was no significant dosimetric change affecting the contralateral parotid and neural structures. CONCLUSIONS: Although patient weight loss and parotid volume shrinkage was observed, overall, there was no significant excess dose to the organs at risk. No replanning was felt necessary for this patient cohort, but a larger patient sample will be investigated to further confirm these results. Nevertheless, kilovoltage CBCT is a valuable tool for patient setup verification and monitoring of dosimetric variation during radiotherapy.


Assuntos
Carcinoma de Células Escamosas/radioterapia , Tomografia Computadorizada de Feixe Cônico , Tratamentos com Preservação do Órgão/métodos , Neoplasias Orofaríngeas/radioterapia , Glândula Parótida , Radioterapia de Intensidade Modulada/métodos , Redução de Peso , Adulto , Idoso , Algoritmos , Antineoplásicos/uso terapêutico , Tronco Encefálico/diagnóstico por imagem , Carboplatina/uso terapêutico , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/tratamento farmacológico , Quimiorradioterapia/métodos , Cisplatino/uso terapêutico , Estudos de Viabilidade , Feminino , Humanos , Laringe/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Boca/diagnóstico por imagem , Órgãos em Risco/diagnóstico por imagem , Neoplasias Orofaríngeas/diagnóstico por imagem , Neoplasias Orofaríngeas/tratamento farmacológico , Glândula Parótida/diagnóstico por imagem , Glândula Parótida/efeitos da radiação , Estudos Prospectivos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Medula Espinal/diagnóstico por imagem , Carga Tumoral/efeitos da radiação
5.
Artigo em Inglês | MEDLINE | ID: mdl-22255748

RESUMO

With the introduction of intensive new treatments such as hypo-fractionation and proton beam therapy, localization of the tumor target volume and tracking of points across the skin entrance surface have become critically important. Optical metrology has been used to monitor the patient's bulk position and motion throughout treatment. However systems have not been capable of high temporal and spatial resolution whole-surface topology measurement. We describe the implementation of such a system based on Fourier profilometry. Its algorithm is split into four separate processing stages, including spatial phase determination: descriptions of each stage are given along with the modifications made to increase performance. The optimized system is capable of processing 23 frames per second (fps), with each frame providing 512 × 512 measured points. The data density, accuracy and performance of the system are an order of magnitude improvement on commercially available clinical systems. We show that this performance permits genuinely real-time measurement of a patient, live during both setup and radiation treatment delivery. It is also fast enough to provide smooth dynamic visualizations of motion at all points on the wrap-around body surface for radiotherapy staff and intuitive, direct feed-back to patients.


Assuntos
Neoplasias/radioterapia , Radioterapia (Especialidade)/métodos , Radioterapia/métodos , Pele/patologia , Algoritmos , Calibragem , Desenho de Equipamento , Análise de Fourier , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Movimento (Física) , Radioterapia (Especialidade)/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Fatores de Tempo
6.
Radiother Oncol ; 90(1): 93-8, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19012980

RESUMO

BACKGROUND AND PURPOSE: Intensity-modulated radiotherapy (IMRT) can improve dose homogeneity within the breast planned target volume (PTV), but may be more susceptible to patient/organ motion than standard tangential radiotherapy (RT). We used daily cone-beam CT (CBCT) imaging to assess inter-fraction motion during breast IMRT and its subsequent impact on IMRT and standard RT dose homogeneity. MATERIALS AND METHODS: Ten breast cancer patients selected for IMRT were studied. CBCT images were acquired immediately after daily treatment. Automatic image co-registration was used to determine patient positioning variations. Daily PTV contours were used to calculate PTV variations and daily delivered IMRT and theoretically planned tangential RT dose. RESULTS: Group systematic (and random) setup errors detected by CBCT were 5.7 (3.9)mm laterally, 2.8 (3.5)mm vertically and 2.3 (3.2)mm longitudinally. Rotations >2 degrees in any axis occurred on 53/106 (50%) occasions. Daily PTV volume varied up to 23%. IMRT dose homogeneity was superior at planning and throughout the treatment compared with standard RT (1.8% vs. 15.8% PTV received >105% planned mean dose), despite increased motion sensitivity. CONCLUSIONS: CBCT revealed inadequacies of current patient positioning and verification procedures during breast RT and confirmed improved dose homogeneity using IMRT for the patients studied.


Assuntos
Neoplasias da Mama/radioterapia , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Modelos Lineares , Movimento (Física) , Postura , Estudos Prospectivos , Radiografia Intervencionista , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
7.
Int J Radiat Oncol Biol Phys ; 66(3): 892-7, 2006 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-17011462

RESUMO

PURPOSE: To assess the potential reduction of small bowel volume receiving high-dose radiation by using kilovoltage X-ray cone beam computed tomography (CBCT) and quantized margin selection for adaptive bladder cancer treatment. METHODS AND MATERIALS: Twenty bladder patients were planned conformally using a four-field, 15-mm uniform margin technique. Two additional planning target volumes (PTVs) were created using margins quantized to 5 and 10 mm in the superior direction only. CBCTs (approximately 8 scans/patient) were acquired during treatment. CBCT volumes were registered with CT planning scans to determine setup errors and to select the appropriate PTV of the day. Margin reduction in other directions was considered. Outlining of small bowel in every fraction is required to properly quantify the volume of small bowel spared from high doses. In the case of CBCT this is not always possible owing to artifacts created by small bowel movement and the presence of gas. A simpler method was adopted by considering the volume difference between PTVs created using uniform and adapted margins, which corresponds to the potential volume of small bowel sparing. RESULTS: The average small bowel volume that can be spared by this form of adaptive radiotherapy is 31 +/- 23 cm3 (+/-1 SD). The bladder for 1 patient was systematically smaller than the planning scan and hence demonstrated the largest average reduction of 76 cm3. The clinical target volume to PTV margins in other directions can be safely reduced to 10 mm except in the anterior direction where, like the superior direction, the bladder showed significant variation. CONCLUSIONS: Online CBCT-assisted plan selection based on quantized margins can significantly reduce the volume of small bowel receiving high doses for some bladder patients. CBCT allows the 15-mm margins used in some directions to be safely reduced to 10 mm.


Assuntos
Intestino Delgado/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Neoplasias da Bexiga Urinária/radioterapia , Bexiga Urinária/diagnóstico por imagem , Humanos , Intestino Delgado/efeitos da radiação , Movimento , Lesões por Radiação/prevenção & controle , Radioterapia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias da Bexiga Urinária/diagnóstico por imagem
8.
Int J Radiat Oncol Biol Phys ; 64(4): 1174-8, 2006 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-16376494

RESUMO

PURPOSE: To assess the clinical utility of X-ray volume imaging (XVI) for verification of bladder radiotherapy and to quantify geometric error in bladder radiotherapy delivery. METHODS AND MATERIALS: Twenty subjects undergoing conformal bladder radiotherapy were recruited. X-ray volume images and electronic portal images (EPIs) were acquired for the first 5 fractions and then once weekly. X-ray volume images were co-registered with the planning computed tomography scan and clinical target volume coverage assessed in three dimensions (3D). Interfraction bladder volume change was described by quantifying changes in bladder volume with time. Bony setup errors were compared from both XVI and EPI. RESULTS: The bladder boundary was clearly visible on coronal XVI views in nearly all images, allowing accurate 3D treatment verification. In 93.5% of imaged fractions, the clinical target volume was within the planning target volume. Most subjects displayed consistent bladder volumes, but 25% displayed changes that could be predicted from the first three XVIs. Bony setup errors were similar whether calculated from XVI or EPI. CONCLUSIONS: Coronal XVI can be used to verify 3D bladder radiotherapy delivery. Image-guided interventions to reduce geographic miss and normal tissue toxicity are feasible with this technology.


Assuntos
Carcinoma de Células de Transição/diagnóstico por imagem , Radioterapia Conformacional/métodos , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Bexiga Urinária/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Artefatos , Carcinoma de Células de Transição/radioterapia , Feminino , Gases , Humanos , Masculino , Movimento , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Neoplasias da Bexiga Urinária/radioterapia
9.
Int J Radiat Oncol Biol Phys ; 64(2): 625-34, 2006 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-16343802

RESUMO

PURPOSE: X-ray volumetric imaging (XVI) for the first time allows for the on-treatment acquisition of three-dimensional (3D) kV cone beam computed tomography (CT) images. Clinical imaging using the Synergy System (Elekta, Crawley, UK) commenced in July 2003. This study evaluated image quality and dose delivered and assessed clinical utility for treatment verification at a range of anatomic sites. METHODS AND MATERIALS: Single XVIs were acquired from 30 patients undergoing radiotherapy for tumors at 10 different anatomic sites. Patients were imaged in their setup position. Radiation doses received were measured using TLDs on the skin surface. The utility of XVI in verifying target volume coverage was qualitatively assessed by experienced clinicians. RESULTS: X-ray volumetric imaging acquisition was completed in the treatment position at all anatomic sites. At sites where a full gantry rotation was not possible, XVIs were reconstructed from projection images acquired from partial rotations. Soft-tissue definition of organ boundaries allowed direct assessment of 3D target volume coverage at all sites. Individual image quality depended on both imaging parameters and patient characteristics. Radiation dose ranged from 0.003 Gy in the head to 0.03 Gy in the pelvis. CONCLUSIONS: On-treatment XVI provided 3D verification images with soft-tissue definition at all anatomic sites at acceptably low radiation doses. This technology sets a new standard in treatment verification and will facilitate novel adaptive radiotherapy techniques.


Assuntos
Neoplasias/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Abdominais/diagnóstico por imagem , Neoplasias do Sistema Nervoso Central/diagnóstico por imagem , Feminino , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Masculino , Neoplasias/radioterapia , Neoplasias Pélvicas/diagnóstico por imagem , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/métodos , Neoplasias Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/normas