1.
Knee Surg Sports Traumatol Arthrosc ; 30(8): 2838-2845, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34424356

RESUMO

PURPOSE: The purpose of the study was to compare clinical and radiological results between kinematic alignment (KA) and mechanical alignment (MA) with a posterior-stabilized (PS) total knee arthroplasty (TKA) with a post-cam mechanism at a minimum follow-up of 3 years. The authors hypothesized a higher risk of aseptic loosening when performing KA using PS TKA. METHODS: A retrospective monocentric single surgeon case control study was performed comparing 100 matched patients who had TKA performed using a MA philosophy to 50 patients receiving TKA with a KA technique between January 2016 and October 2017. All patients had the same knee prosthesis (GMK primary posterior-stabilized, Medacta®, Switzerland). Patient specific cutting blocks were used in both groups and a restricted KA (rKA) was aimed in the KA group. A hybrid cementation technique was performed. The new Knee Society Score (KSS) and radiological assessment were collected preoperatively and at the final follow-up. Comparisons between groups were done with the T test or Fisher exact test. Global survival curves were estimated with Kaplan-Meier model. Significance was set at p < 0.05. RESULTS: Mean follow-up was 42.9 months ± 3.6 (range 37.6-46.7) and 53.3 months ± 4.1 (range 45.5-59.8) for rKA and MA groups. Postoperatively, no significant differences were found for clinical scores between both groups. Radiological assessment found similar postoperative Hip-Knee-Ankle angle for rKA and MA groups (178° versus 179° respectively, NS). At last follow-up, a significant higher survivorship was found for the MA group compared to the rKA group (97 versus 84%; p < 0.001) for aseptic loosening revision as the endpoint. CONCLUSION: An increased risk of tibial implant loosening was found with rKA compared to MA using a posterior-stabilized TKA with a post-cam system at short-term follow-up. Caution should be taken when choosing the TKA design while performing rKA. LEVEL OF EVIDENCE: Retrospective case-control study, Level IV.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Estudos de Casos e Controles , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/etiologia , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA