1.
Med Phys ; 47(4): 1468-1480, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31971612

RESUMO

PURPOSE: A retrospective analysis of the dose delivery system (DDS) performances of the initial clinical operation at CNAO (Centro Nazionale di Adroterapia Oncologica) is reported, and compared with the dose delivery accuracy following the implementation of a position feedback control. METHODS: Log files and raw data of the DDS were analyzed for every field of patients treated with protons and carbon ions between January 2012 and April 2013 (~3800 fields). To investigate the DDS accuracy, the spot positions and the number of particles per spot measured by the DDS and prescribed by the treatment planning system were compared for each field. The impact of deviations on dose distributions was studied by comparing, through the gamma-index method, 2 three-dimensional (3D) physical dose maps (one for prescribed, one for measured data), generated by a validated dose computation software. The maximum gamma and the percentage of points with gamma ≤ 1 (passing volume) were studied as a function of the treatment day, and correlated with the deviations from the prescription in the measured number of particles and spot positions. Finally, delivered dose distributions of same treatment plans were compared before and after the implementation of a feedback algorithm for the correction of small position deviations, to study the effect on the delivery quality. A double comparison of prescribed and measured 3D maps, before and after feedback implementation, is reported and studied for a representative treatment delivered in 2012, redelivered on a polymethyl methacrylate (PMMA) block in 2018. RESULTS: Systematic deviations of spot positions, mainly due to beam lateral offsets, were always found within 1.5 mm, with the exception of the initial clinical period. The number of particles was very stable, as possible deviations are exclusively related to the quantization error in the conversion from monitor counts to particles. For the chosen representative patient treatment, the gamma-index evaluation of prescribed and measured dose maps, before and after feedback implementation, showed a higher variability of maximum gamma for the 2012 irradiation, with respect to the reirradiation of 2018. However, the 2012 passing volume is >99.8% for the sum of all fields, which is comparable to the value of 2018, with the exception of one day with 98.2% passing volume, probably related to an instability of the accelerating system. CONCLUSIONS: A detailed retrospective analysis of the DDS performances in the initial period of CNAO clinical activity is reported. The spot position deviations are referable to beam lateral offset fluctuations, while almost no deviation was found in the number of particles. The impact of deviations on dose distributions showed that the position feedback implementation and the increased beam control capability acquired after the first years of clinical experience led to an evident improvement in the DDS stability, evaluated in terms of gamma-index as a measure of the impact on dose distributions. However, the clinical effect of the maximum gamma variability found in the 2012 representative irradiation is mitigated by averaging along the number of fractions, and the high percentage of passing volumes confirmed the accuracy of the delivery even before the feedback implementation.


Assuntos
Doses de Radiação , Radioterapia Assistida por Computador/métodos , Radioterapia com Íons Pesados , Humanos , Terapia com Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
2.
J Appl Clin Med Phys ; 14(6): 4420, 2013 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-24257285

RESUMO

When using an electronic portal imaging device (EPID) for dosimetric verifications, the calibration of the sensitive area is of paramount importance. Two calibration methods are generally adopted: one, empirical, based on an external reference dosimeter or on multiple narrow beam irradiations, and one based on the EPID response simulation. In this paper we present an alternative approach based on an intercalibration procedure, independent from external dosimeters and from simulations, and is quick and easy to perform. Each element of a detector matrix is characterized by a different gain; the aim of the calibration procedure is to relate the gain of each element to a reference one. The method that we used to compute the relative gains is based on recursive acquisitions with the EPID placed in different positions, assuming a constant fluence of the beam for subsequent deliveries. By applying an established procedure and analysis algorithm, the EPID calibration was repeated in several working conditions. Data show that both the photons energy and the presence of a medium between the source and the detector affect the calibration coefficients less than 1%. The calibration coefficients were then applied to the acquired images, comparing the EPID dose images with films. Measurements were performed with open field, placing the film at the level of the EPID. The standard deviation of the distribution of the point-to-point difference is 0.6%. An approach of this type for the EPID calibration has many advantages with respect to the standard methods - it does not need an external dosimeter, it is not related to the irradiation techniques, and it is easy to implement in the clinical practice. Moreover, it can be applied in case of transit or nontransit dosimetry, solving the problem of the EPID calibration independently from the dose reconstruction method.


Assuntos
Eletrônica Médica , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Algoritmos , Calibragem , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica , Silício