Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Front Oncol ; 14: 1295772, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38690171

RESUMO

Background: Hormone receptor-positive tumors are unlikely to exhibit a complete pathological tumor response. The association of CDK 4/6 inhibitor plus hormone therapy has changed this perspective. Case presentation: In this study, we retrospectively reviewed the charts of patients with a diagnosis of luminal A/B advanced/metastatic tumors treated with a CDK 4/6 inhibitor-based therapy. In this part of the study, we present clinical and ultrasound evaluation. Eight female patients were considered eligible for the study aims. Three complete and five partial responses were reported, including a clinical tumor response of 50% or more in five out of nine assessed lesions (55%). All patients showed a response on ultrasound. The mean lesion size measured by ultrasound was 27.1 ± 15.02 mm (range, 6-47 mm) at the baseline; 16.08 ± 14.6 mm (range, 0-40 mm) after 4 months (T1); and 11.7 ± 12.9 mm (range, 0-30 mm) at the 6 months follow-up (T2). Two patients underwent surgery. The radiological complete response found confirmation in a pathological complete response, while the partial response matched a moderate residual disease. Conclusion: The evaluation of breast cancer by ultrasound is basically informative of response and may be an easy and practical tool to monitor advanced tumors, especially in advanced/unfit patients who are reluctant to invasive exams.

2.
Radiol Case Rep ; 19(5): 2013-2019, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38449482

RESUMO

Regorafenib is a multikinase inhibitor approved for treatment of patients with metastatic Colo-Rectal Cancer (mCRC) and Gastro-Intestinal Stromal Tumor (GIST) progression after the administration of other tyrosine-kinase inhibitors such as imatinib and sunitinib. Only a handful of severe side effects such as intestinal perforations and fistulas have been described in the literature in patients undergoing multikinase inhibitor treatment. We report a case of a patient with peritoneal mCRC who experienced an intestinal perforation during the administration of Regorafenib and review the literature. A 48-year-old man with previously resected sigmoid colon cancer and peritoneal metastatic disease under Regorafenib treatment presented to our Emergency Department with severe abdominal pain and asthenia. Abdominal X-ray and contrast-enhanced computed tomography examination revealed an intestinal perforation. The patient underwent emergency surgery which demonstrated acute diffuse peritonitis, necrosis, and perforation of a distal ileal loop affected by peritoneal metastatic disease. The necrosis of peritoneal implants on bowel walls could be regarded as a potential factor leading to intestinal perforation in metastatic colorectal cancer patients undergoing Regorafenib treatment complaining of severe abdominal pain and asthenia. Surgeons, radiologists and oncologists should always keep in mind this rare adverse event during Regorafenib administration. Appropriate diagnostic tests and treatments should be carried out.

3.
Curr Med Imaging ; 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38415477

RESUMO

In the world, breast cancer is the most commonly diagnosed cancer among women. Currently, MRI is the most sensitive breast imaging method for detecting breast cancer, although false positive rates are still an issue. To date, the accuracy of breast MRI is widely recognized across various clinical scenarios, in particular, staging of known cancer, screening for breast cancer in high-risk women, and evaluation of response to neoadjuvant chemotherapy. Since technical development and further clinical indications have expanded over recent years, dedicated breast radiologists need to constantly update their knowledge and expertise to remain confident and maintain high levels of diagnostic performance in breast MRI. This review aims to detail current and future applications of breast MRI, from technological requirements and advances to new multiparametric and abbreviated protocols, and ultrafast imaging, as well as current and future indications.

4.
Eur Radiol ; 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38227202

RESUMO

OBJECTIVES: To perform a survey among members of the European Society of Breast Imaging (EUSOBI) regarding the use of contrast-enhanced mammography (CEM). METHODS: A panel of nine board-certified radiologists developed a 29-item online questionnaire, distributed to all EUSOBI members (inside and outside Europe) from January 25 to March 10, 2023. CEM implementation, examination protocols, reporting strategies, and current and future CEM indications were investigated. Replies were exploratively analyzed with descriptive and non-parametric statistics. RESULTS: Among 434 respondents (74.9% from Europe), 50% (217/434) declared to use CEM, 155/217 (71.4%) seeing less than 200 CEMs per year. CEM use was associated with academic settings and high breast imaging workload (p < 0.001). The lack of CEM adoption was most commonly due to the perceived absence of a clinical need (65.0%) and the lack of resources to acquire CEM-capable systems (37.3%). CEM protocols varied widely, but most respondents (61.3%) had already adopted the 2022 ACR CEM BI-RADS® lexicon. CEM use in patients with contraindications to MRI was the most common current indication (80.6%), followed by preoperative staging (68.7%). Patients with MRI contraindications also represented the most commonly foreseen CEM indication (88.0%), followed by the work-up of inconclusive findings at non-contrast examinations (61.5%) and supplemental imaging in dense breasts (53.0%). Respondents declaring CEM use and higher CEM experience gave significantly more current (p = 0.004) and future indications (p < 0.001). CONCLUSIONS: Despite a trend towards academic high-workload settings and its prevalent use in patients with MRI contraindications, CEM use and progressive experience were associated with increased confidence in the technique. CLINICAL RELEVANCE STATEMENT: In this first survey on contrast-enhanced mammography (CEM) use and perspectives among the European Society of Breast Imaging (EUSOBI) members, the perceived absence of a clinical need chiefly drove the 50% CEM adoption rate. CEM adoption and progressive experience were associated with more extended current and future indications. KEY POINTS: • Among the 434 members of the European Society of Breast Imaging who completed this survey, 50% declared to use contrast-enhanced mammography in clinical practice. • Due to the perceived absence of a clinical need, contrast-enhanced mammography (CEM) is still prevalently used as a replacement for MRI in patients with MRI contraindications. • The number of current and future CEM indications marked by respondents was associated with their degree of CEM experience.

5.
Diagnostics (Basel) ; 13(24)2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-38132204

RESUMO

Pathological conditions affecting the male breast (MB) share some similarities with those found in women, while others are specific to men. The first part of this review provides an overview of MB disorders, exploring the most common types of MB diseases. The second part then emphasizes the state-of-the-art approaches proposed in the literature for screening and follow-up with MB cancer patients, which highlights the importance of tailored strategies for diagnosis, follow-up, and identifying high-risk populations. Considering the increasing attention in recent years on the topic, transgender individuals are also included in this review. Together with the MB, it is an understudied category thus far. This review aims to raise awareness among radiologists that MBs should be approached differently from female breasts, contributing to the advancement of medical knowledge, improving patient outcomes, and promoting early detection of MB disorders. The review also provides an update on breast cancer and screening in the transgender population.

6.
Radiol Case Rep ; 18(12): 4345-4350, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37789921

RESUMO

Osteosarcoma (OS) of the head and neck is a rare and aggressive disease characterized by the formation of osteoid by malignant osteoblasts. The mandible or maxilla are the most common sites of presentation. Radiologically, these tumors show considerable, destructive growth with periosteal reaction, which can suggest the diagnosis of OS. 3D printing, as an emerging technology, can play a role in orthopedic oncology by providing patient-specific 3D printed models to improve surgical planning and facilitate patient understanding. We present the case of a male in his early 30s with a final histological diagnosis of recurrent osteosarcoma of the left maxilla, where a 3D printed model was helpful for the diagnostic workup, surgical planning, and the procedure.

7.
J Clin Med ; 12(14)2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37510833

RESUMO

Dual-layer Dual-Energy CT (dl-DECT) allows one to create virtual non-contrast (VNC) reconstructions from contrast-enhanced CT scans, with a consequent decrease of the radiation dose. This study aims to assess the reliability of VNC for the diagnostic evaluation of renal masses in comparison with true non-contrast (TNC) images. The study cohort included 100 renal masses in 40 patients who underwent dl-DECT between June and December 2021. Attenuation values and standard deviations were assessed through the drawing of regions of interest on TNC and VNC images reconstructed from corticomedullary and nephrographic phases. A Wilcoxon signed-rank test was performed in order to assess equivalence of data and Spearman's Rho correlation coefficient to evaluate correlations between each parameter. The diagnostic accuracy of VNC was estimated through the performance of receiver operating characteristic (ROC) curve analysis. Differences between attenuation values were, respectively, 74%, 18%, 5% and 3% (TNC-VNCcort), and 74%, 15%, 9% and 2% (TNC-VNCneph). The Wilcoxon signed-rank test demonstrated the equivalence of attenuation values between the TNC and VNC images. The diagnostic performance of VNC images in the depiction of kidney simple cysts remains high compared to TNC (VNCcort-AUC: 0.896; VNCneph-AUC: 0.901, TNC-AUC: 0.903). In conclusion, quantitative analysis of attenuation values showed a strong agreement between VNC and TNC images in the evaluation of renal masses.

8.
Radiol Med ; 128(8): 891-899, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37310558

RESUMO

PURPOSE: To compare conventional CT images and virtual monoenergetic images (VMI) at dual-layer dual-energy CT (dlDECT) in patients with colorectal cancer (CRC) through quantitative analysis and to investigate the added value of VMI. MATERIAL AND METHODS: Sixty-six consecutive patients with histologically documented CRC and available VMI reconstructions were retrospectively investigated. Subsequently, forty-two patients, without any colonic disease at colonoscopy, were selected as control group. Conventional CT images and VMI reconstructions at energy levels ranging from 40 (VMI40) to 100 keV (VMI100) in 10 keV increments, were obtained from the late arterial phase. First, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were obtained to select the best VMI reconstruction. Finally, the diagnostic accuracy of conventional CT and VMI40 in late arterial phase was evaluated. RESULTS: On quantitative analysis, SNR and CNR were higher for VMI40 (19.5 ± 7.7 and 11.8 ± 6.2, respectively) with statistically significant differences compared to conventional CT (P < 0.05) and all the other VMI reconstructions (P < 0.05), except for VMI50 (P > 0.05). The addition of VMI40 to conventional CT images significantly improved the area under the curve (AUC) for the diagnosis of CRC, increasing it from 0.875 to 0.943 for reader 1 (P < 0.05) and from 0.916 to 0.954 for reader 2 (P < 0.05). The improvement was greater in the less experienced radiologist (0.068) compared to the more experienced one (0.037). CONCLUSION: VMI40 has showed the highest quantitative image parameters. Furthermore, the use of VMI40 can lead to a significant improvement in the diagnostic performance for detecting CRC.


Assuntos
Neoplasias Colorretais , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Razão Sinal-Ruído , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Neoplasias Colorretais/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
9.
Radiol Case Rep ; 18(3): 809-813, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36589500

RESUMO

Breast metastasis from extra-mammary neoplasm is a rare condition, accounting for approximately 1.2%-2% of all breast malignancies. Melanoma, lung cancer, gynecological, and hematological cancers can metastasis to the breast. Male breast metastasis is extremely rare and, no evidence of metastasis from cutaneous squamous cell carcinoma in a male breast have been reported to our knowledge. We describe a case of an 81-year-old man who came to our attention for a palpable solid mass in the upper-outer aspect of the left breast with the final histological diagnosis of breast metastasis from non-keratoblastic cutaneous squamous cell carcinoma.

10.
Curr Med Imaging ; 19(8): 799-806, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36443968

RESUMO

Breast cancer accounts for 30% of female cancers and is the second leading cause of cancerrelated deaths in women. The rate is rising at 0.4% per year. Early detection is crucial to improve treatment efficacy and overall survival of women diagnosed with breast cancer. Digital Mammography and Digital Breast Tomosynthesis have widely demonstrated their role as a screening tool. However, screening mammography is limited by radiologist's experience, unnecessarily high recalls, overdiagnosis, overtreatment and, in the case of Digital Breast Tomosynthesis, long reporting time. This is compounded by an increasing shortage of manpower and resources issue, especially among breast imaging specialists. Recent advances in image analysis with the use of artificial intelligence (AI) in breast imaging have the potential to overcome some of these needs and address the clinical challenges in cancer detection, assessment of treatment response, and monitoring disease progression. This article focuses on the most important clinical implication and future application of AI in the field of digital mammography and digital breast tomosynthesis, providing the readers with a comprehensive overview of AI impact in cancer detection, diagnosis, reduction of workload and breast cancer risk stratification.


Assuntos
Neoplasias da Mama , Mamografia , Feminino , Humanos , Mamografia/métodos , Neoplasias da Mama/diagnóstico por imagem , Inteligência Artificial , Detecção Precoce de Câncer/métodos , Programas de Rastreamento
11.
Eur J Radiol ; 156: 110523, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36122521

RESUMO

PURPOSE: To investigate the diagnostic value of multiparametric MRI (mpMRI) including dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and diffusion-weighted imaging (DWI) in non-mass enhancing breast tumors. METHOD: Patients who underwent mpMRI, who were diagnosed with a suspicious non-mass enhancement (NME) on DCE-MRI (BI-RADS 4/5), and who subsequently underwent image-guided biopsy were retrospectively included. Two radiologists independently evaluated all NMEs, on both DCE-MR images and high-b-value DW images. Different mpMRI reading approaches were evaluated: 1) with a fixed apparent diffusion coefficient (ADC) threshold (<1.3 malignant, ≥1.3 benign) based on the recommendation by the European Society of Breast Imaging (EUSOBI); 2) with a fixed ADC threshold (<1.5 malignant, ≥1.5 benign) based on recently published trial data; 3) with an ADC threshold adapted to the assigned BI-RADS classification using a previously published reading method; and 4) with individually determined best thresholds for each reader. RESULTS: The final study sample consisted of 66 lesions in 66 patients. DCE-MRI alone had the highest sensitivity for breast cancer detection (94.8-100 %), outperforming all mpMRI reading approaches (R1 74.4-87.1 %, R2 71.7-94.8 %) and DWI alone (R1 74.4 %, R2 79.4 %). The adapted approach achieved the best specificity for both readers (85.1 %), resulting in the best diagnostic accuracy for R1 (86.5 %) but a moderate diagnostic accuracy for R2 (77.2 %). CONCLUSION: mpMRI has limited added diagnostic value to DCE-MRI in the assessment of NME.


Assuntos
Neoplasias da Mama , Imageamento por Ressonância Magnética Multiparamétrica , Humanos , Feminino , Estudos Retrospectivos , Meios de Contraste , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Mama/diagnóstico por imagem , Sensibilidade e Especificidade
12.
Radiol Case Rep ; 17(6): 1887-1889, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35401905

RESUMO

The canal of Nuck is an abnormal patent pouch of the parietal peritoneum caused by the incomplete obliteration of the processus vaginalis in females. The most common disorders of the canal of Nuck are: hernia, hydrocele and endometriosis. Pseudomyxoma Peritonei (PMP) is a clinical condition characterized by the accumulation of mucinous material on the surfaces and in the recesses of the peritoneal cavity, resulting from the perforation of an appendiceal mucinous neoplasm. We report the case of a young woman with a clinical history of chronic pelvic pain and infertility who was referred to our center after being diagnosed with appendiceal mucinous neoplasm and PMP. MRI staging examination revealed the right canal of Nuck filled with mucinous material, which was confirmed at surgery. The involvement of canal of Nuck is extremely rare in PMP. MRI provides a sensitive imaging modality for appropriate preoperative planning of PMP and helps surgeons identify uncommon disease sites such such as the canal of Nuck in women, which, if missed, may prevent complete cytoreductive surgery.

13.
Radiol Med ; 127(5): 471-483, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35303247

RESUMO

BACKGROUND: Radiology is an essential tool in the management of a patient. The aim of this manuscript was to build structured report (SR) Mammography based in Breast Cancer. METHODS: A working team of 16 experts (group A) was composed to create a SR for Mammography Breast Cancer. A further working group of 4 experts (group B), blinded to the activities of the group A, was composed to assess the quality and clinical usefulness of the SR final draft. Modified Delphi process was used to assess level of agreement for all report sections. Cronbach's alpha (Cα) correlation coefficient was used to assess internal consistency and to measure quality analysis according to the average inter-item correlation. RESULTS: The final SR version was built by including n = 2 items in Personal Data, n = 4 items in Setting, n = 2 items in Comparison with previous breast examination, n = 19 items in Anamnesis and clinical context; n = 10 items in Technique; n = 1 item in Radiation dose; n = 5 items Parenchymal pattern; n = 28 items in Description of the finding; n = 12 items in Diagnostic categories and Report and n = 1 item in Conclusions. The overall mean score of the experts and the sum of score for structured report were 4.9 and 807 in the second round. The Cronbach's alpha (Cα) correlation coefficient was 0.82 in the second round. About the quality evaluation, the overall mean score of the experts was 3.3. The Cronbach's alpha (Cα) correlation coefficient was 0.90. CONCLUSIONS: Structured reporting improves the quality, clarity and reproducibility of reports across departments, cities, countries and internationally and will assist patient management and improve breast health care and facilitate research.


Assuntos
Neoplasias da Mama , Neoplasias da Mama/diagnóstico por imagem , Técnica Delphi , Feminino , Humanos , Mamografia , Reprodutibilidade dos Testes , Raios X
14.
Insights Imaging ; 12(1): 179, 2021 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-34862955

RESUMO

All substances exert magnetic properties in some extent when placed in an external magnetic field. Magnetic susceptibility represents a measure of the magnitude of magnetization of a certain substance when the external magnetic field is applied. Depending on the tendency to be repelled or attracted by the magnetic field and in the latter case on the magnitude of this effect, materials can be classified as diamagnetic or paramagnetic, superparamagnetic and ferromagnetic, respectively. Knowledge of type and extent of susceptibility of common endogenous and exogenous substances and how their magnetic properties affect the conventional sequences used in magnetic resonance imaging (MRI) can help recognize them and exalt or minimize their presence in the acquired images, so as to improve diagnosis in a wide variety of benign and malignant diseases. Furthermore, in the context of diamagnetic susceptibility, chemical shift imaging enables to assess the intra-voxel ratio between water and fat content, analyzing the tissue composition of various organs and allowing a precise fat quantification. The following article reviews the fundamental physical principles of magnetic susceptibility and examines the magnetic properties of the principal endogenous and exogenous substances of interest in MRI, providing potential through representative cases for improved diagnosis in daily clinical routine.

15.
Insights Imaging ; 12(1): 63, 2021 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-34037876

RESUMO

Breast lesions with uncertain malignant behavior, also known as high-risk or B3 lesions, are composed of a variety of pathologies with differing risks of associated malignancy. While open excision was previously preferred to manage all high-risk lesions, tailored management has been increasingly favored to reduce overtreatment and spare patients from unnecessary anxiety or high healthcare costs associated with surgical excision. The purpose of this work is to provide the reader with an accurate overview focused on the main high-risk lesions of the breast: atypical intraductal epithelial proliferation (atypical ductal hyperplasia), lobular neoplasia (including the subcategories lobular carcinoma in situ and atypical lobular hyperplasia), flat epithelial atypia, radial scar and papillary lesions, and phyllodes tumor. Beyond merely presenting the radiological aspects of these lesions and the recent literature, information about their potential upgrade rates is discussed in order to provide a useful guide for appropriate clinical management while avoiding the risks of unnecessary surgical intervention (overtreatment).

16.
Radiol Case Rep ; 16(6): 1557-1563, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33981377

RESUMO

Nodular fasciitis is a benign tumor of soft tissues originating from the proliferation of fibroblasts and myofibroblasts, generally developing between the subcutaneous tissue and the underlying muscular layer. Nodular fasciitis predominantly localizes in the upper extremities, trunk, head and neck. Biomolecular and immunohistochemical analyses result essential to demonstrate the benign origin of the process, also confirmed by very low recurrence rate after complete excision, which represents the gold standard for treatment. We report the case of a 36 years-old man who developed a nodular protuberance clinically evident in the upper-left side of the thorax. We further, highlight the main characteristics of this rare neoplasm trough a thorough review of the literature.

17.
Radiol Med ; 126(7): 901-909, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33954899

RESUMO

Vesicoureteral reflux (VUR) is a pathological condition contradistinguished by monolateral or bilateral retrograde flow of urine from the bladder to the ureter and to the kidney. If not properly recognized and treated, VUR can potentially be associated to several complications such as recurrent infections and possible secondary scars with Chronic Kidney Disease (CKD). Furthermore, it represents an important risk factor for nephrovascular hypertension. During the last 20 years, the diagnostic approach to this entity has passed through several, drastic changes: indeed, since its introduction in 1994 contrast-enhanced voiding urosonography (ceVUS) has gradually accompanied the voiding cystourethrography (VCUG) as alternative imaging technique for the diagnosis and staging of VUR. Despite a large number of papers has strongly encouraged its use in clinical practice, due to the lack of ionizing radiations and its high sensitivity rate, to date almost all the guidelines only include the VCUG for VUR diagnosis. The introduction of technologically advanced US software and the approval of the intravesical administration of ultrasound contrast agents by the Food and Drug Administration (FDA) and by the European Medicine Agency (EMA) have to induce the Scientific Community to a deep revaluation of the role of ceVUS in the diagnosis and follow-up of VUR: urosonography might extensively replace VCUG as the reference method, reserving to cystourethrography a role in the most complex anatomic settings for pre-surgical evaluation.


Assuntos
Meios de Contraste/intoxicação , Ultrassonografia/métodos , Bexiga Urinária/diagnóstico por imagem , Micção/fisiologia , Refluxo Vesicoureteral/diagnóstico , Humanos , Bexiga Urinária/fisiopatologia , Refluxo Vesicoureteral/fisiopatologia
18.
Clin Cancer Res ; 27(7): 1941-1948, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33446565

RESUMO

PURPOSE: Diffusion-weighted imaging with the calculation of an apparent diffusion coefficient (ADC) has been proposed as a quantitative biomarker on contrast-enhanced MRI (CE-MRI) of the breast. There is a need to approve a generalizable ADC cutoff. The purpose of this study was to evaluate whether a predefined ADC cutoff allows downgrading of BI-RADS 4 lesions on CE-MRI, avoiding unnecessary biopsies. EXPERIMENTAL DESIGN: This was a retrospective, multicentric, cross-sectional study. Data from five centers were pooled on the individual lesion level. Eligible patients had a BI-RADS 4 rating on CE-MRI. For each center, two breast radiologists evaluated the images. Data on lesion morphology (mass, non-mass), size, and ADC were collected. Histology was the standard of reference. A previously suggested ADC cutoff (≥1.5 × 10-3 mm2/second) was applied. A negative likelihood ratio of 0.1 or lower was considered as a rule-out criterion for breast cancer. Diagnostic performance indices were calculated by ROC analysis. RESULTS: There were 657 female patients (mean age, 42; SD, 14.1) with 696 BI-RADS 4 lesions included. Disease prevalence was 59.5% (414/696). The area under the ROC curve was 0.784. Applying the investigated ADC cutoff, sensitivity was 96.6% (400/414). The potential reduction of unnecessary biopsies was 32.6% (92/282). CONCLUSIONS: An ADC cutoff of ≥1.5 × 10-3 mm2/second allows downgrading of lesions classified as BI-RADS 4 on breast CE-MRI. One-third of unnecessary biopsies could thus be avoided.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem , Adulto , Biópsia , Neoplasias da Mama/patologia , Meios de Contraste , Estudos Transversais , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
19.
Eur Radiol ; 31(2): 975-982, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32870394

RESUMO

OBJECTIVES: To assess whether no enhancement on pre-treatment MRI can rule out malignancy of additional US mass(es) initially assessed as BI-RADS 3 or 4 in women with newly diagnosed breast cancer. METHODS: This retrospective study included consecutive women from 2010-2018 with newly diagnosed breast cancer; at least one additional breast mass (distinct from index cancer) assigned a BI-RADS 3 or 4 on US; and a bilateral contrast-enhanced breast MRI performed within 90 days of US. All malignant masses were pathologically proven; benign masses were pathologically proven or defined as showing at least 2 years of imaging stability. Incidence of malignant masses and NPV were calculated on a per-patient level using proportions and exact 95% CIs. RESULTS: In 230 patients with 309 additional masses, 140/309 (45%) masses did not enhance while 169/309 (55%) enhanced on MRI. Of the 140 masses seen in 105 women (mean age, 54 years; range 28-82) with no enhancement on MRI, all had adequate follow-up and 140/140 (100%) were benign, of which 89/140 (63.6%) were pathologically proven and 51/140 (36.4%) demonstrated at least 2 years of imaging stability. Pre-treatment MRI demonstrating no enhancement of US mass correlate(s) had an NPV of 100% (95% CI 96.7-100.0). CONCLUSIONS: All BI-RADS 3 and 4 US masses with a non-enhancing correlate on pre-treatment MRI were benign. The incorporation of MRI, when ordered by the referring physician, may decrease unnecessary follow-up imaging and/or biopsy if the initial US BI-RADS assessment and management recommendation were to be retrospectively updated. KEY POINTS: • Of 309 BI-RADS 3 or 4 US masses with a corresponding mass on MRI, 140/309 (45%) demonstrated no enhancement whereas 169/309 (55%) demonstrated enhancement • All masses classified as BI-RADS 3 or 4 on US without enhancement on MRI were benign • MRI can rule out malignancy in non-enhancing US masses with an NPV of 100.


Assuntos
Neoplasias da Mama , Mama , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Estudos Retrospectivos
20.
Cancers (Basel) ; 12(12)2020 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-33255412

RESUMO

To investigate the value of contrast-enhanced mammography (CEM) compared to full-field digital mammography (FFDM) in screening breast cancer patients after breast-conserving surgery (BCS), this Health Insurance Portability and Accountability Act-compliant, institutional review board-approved retrospective, single-institution study included 971 CEM exams in 541 asymptomatic patients treated with BCS who underwent screening CEM between January 2013 and November 2018. Histopathology, or at least a one-year follow-up, was used as the standard of reference. Twenty-one of 541 patients (3.9%) were diagnosed with ipsi- or contralateral breast cancer: six (28.6%) cancers were seen with low-energy images (equivalent to FFDM), an additional nine (42.9%) cancers were detected only on iodine (contrast-enhanced) images, and six interval cancers were identified within 365 days of a negative screening CEM. Of the 10 ipsilateral cancers detected on CEM, four were detected on low-energy images (40%). Of the five contralateral cancers detected on CEM, two were detected on low-energy images (40%). Overall, the cancer detection rate (CDR) for CEM was 15.4/1000 (15/971), and the positive predictive value (PPV3) of the biopsies performed was 42.9% (15/35). For findings seen on low-energy images, with or without contrast, the CDR was 6.2/1000 (6/971), and the PPV3 of the biopsies performed was 37.5% (6/16). In the post-BCS screening setting, CEM has a higher CDR than FFDM.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA