Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur Urol Oncol ; 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38824004

RESUMO

BACKGROUND AND OBJECTIVE: Prostate Imaging for Recurrence Reporting (PI-RR) was introduced in 2021 to standardize the interpretation and reporting of multiparametric magnetic resonance imaging (MRI) for prostate cancer following whole-gland treatment. The system scores image on a scale from 1 to 5 and has shown promising results in single-center studies. The aim of our systematic review and meta-analysis was to assess the diagnostic performance of the PI-RR system in predicting the likelihood of local recurrence after whole-gland treatment. METHODS: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for diagnostic test accuracy were followed. Relevant databases were searched up to December 2023. Primary studies met the eligibility criteria if they reported MRI diagnostic performance in prostate cancer recurrence using PI-RR. Diagnostic performance for MRI was assessed using two different cutoff points (≥3 or ≥4 for positivity according to the PI-RR system). A meta-analysis with a random-effects model was used to estimate pooled sensitivity and specificity values. KEY FINDINGS AND LIMITATIONS: Sixteen articles were identified for full-text reading, of which six were considered eligible, involving a total of 467 patients. Using a cutoff of PI-RR ≥3 (4 studies) for recurrent disease, the sensitivity was 77.8% (95% confidence interval [CI] 69.9-84.1%) and the specificity was 80.2% (95% CI 58.2-92.2%). Using a cutoff of PI-RR ≥4 (4 studies), the sensitivity was 61.9% (95% CI 35.6-82.7%) and the specificity was 86.6% (95% CI 75.1-93.3%). Overall, the inter-rater agreement varied from fair to excellent. CONCLUSIONS AND CLINICAL IMPLICATIONS: PI-RR is accurate in detecting local recurrence after whole-gland treatment for prostate cancer and shows fair-to-good to excellent inter-reader agreement. Overall, a PI-RR cutoff of ≥3 showed high sensitivity and specificity. PATIENT SUMMARY: We reviewed studies that reported on how good MRI scans using a scoring system called PI-RR were in detecting recurrence of prostate cancer. We found that this system shows good performance, with fair to excellent agreement between different radiologists.

2.
Ophthalmologica ; 241(4): 211-219, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30889590

RESUMO

PURPOSE: The main objective of this study was to investigate the microbiological spectrum of endophthalmitis after anti-VEGF injections and to compare streptococcal with non-streptococcus-associated cases with regard to baseline characteristics and injection procedure. METHODS: Retrospective, international multicenter study of patients with culture-positive endophthalmitis after intravitreal anti-VEGF injection at 17 different retina referral centers. RESULTS: Eighty-three cases with 87 identified pathogens were included. Coagulase-negative staphylococci (59%) and viridans streptococci (15%) were the most frequent pathogens found. The use of postoperative antibiotics and performance of injections in an operating room setting significantly reduced the rate of streptococcus-induced endophthalmitis cases (p = 0.01 for both). CONCLUSION: We found a statistically significant lower rate of postinjectional local antibiotic therapy and operating room-based procedures among the streptococcus-induced cases compared to cases caused by other organisms.


Assuntos
Antibacterianos/uso terapêutico , Bactérias/isolamento & purificação , Endoftalmite/microbiologia , Infecções Oculares Bacterianas/microbiologia , Acuidade Visual , Corpo Vítreo/microbiologia , Idoso , Endoftalmite/tratamento farmacológico , Endoftalmite/etiologia , Feminino , Seguimentos , Humanos , Injeções Intravítreas/efeitos adversos , Masculino , Doenças Retinianas/tratamento farmacológico , Estudos Retrospectivos , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores
3.
Retina ; 39(1): 44-51, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29697589

RESUMO

PURPOSE: To investigate efficacy and safety of repeated dexamethasone (DEX) implants over 24 months, in diabetic macular edema (DME) eyes that were treatment naive compared with eyes refractory to anti-vascular endothelial growth factor treatment, in a real-life environment. METHODS: This multicenter international retrospective study assessed best-corrected visual acuity and central subfield thickness (CST) of naive and refractory eyes to anti-vascular endothelial growth factor injections treated with dexamethasone implants. Safety data (intraocular pressure rise and cataract surgery) were recorded. RESULTS: A total of 130 eyes from 125 patients were included. Baseline best-corrected visual acuity and CST were similar for naive (n = 71) and refractory eyes (n = 59). Both groups improved significantly in vision after 24 months (P < 0.001). However, naive eyes gained statistically significantly more vision than refractory eyes (+11.3 ± 10.0 vs. 7.3 ± 2.7 letters, P = 0.01) and were more likely to gain ≥10 letters (OR 3.31, 95% CI 1.19-9.24, P = 0.02). At 6, 12, and 24 months, CST was significantly decreased compared with baseline in both naive and refractory eyes; however, CST was higher in refractory eyes than in naive eyes (CST 279 ± 61 vs. 313 ± 125 µm, P = 0.10). CONCLUSION: Over a follow-up of 24 months, vision improved in diabetic macular edema eyes after treatment with dexamethasone implants, both in eyes that were treatment naive and eyes refractory to anti-vascular endothelial growth factor treatment; however, improvement was greater in naive eyes.


Assuntos
Inibidores da Angiogênese/uso terapêutico , Dexametasona/administração & dosagem , Retinopatia Diabética/tratamento farmacológico , Resistência a Medicamentos , Macula Lutea/patologia , Edema Macular/tratamento farmacológico , Acuidade Visual , Idoso , Retinopatia Diabética/complicações , Retinopatia Diabética/fisiopatologia , Implantes de Medicamento , Fatores de Crescimento Endotelial/antagonistas & inibidores , Feminino , Seguimentos , Glucocorticoides/administração & dosagem , Humanos , Pressão Intraocular/fisiologia , Injeções Intravítreas , Edema Macular/etiologia , Edema Macular/fisiopatologia , Masculino , Estudos Retrospectivos , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento
4.
Ophthalmology ; 125(2): 267-275, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28935399

RESUMO

PURPOSE: Identification and characterization of patients with diabetic macular edema (DME) are important for individualizing treatment and optimizing outcome. We investigated OCT biomarkers for DME treated by intravitreal dexamethasone (DEX) implant. DESIGN: Multicenter, retrospective, observational cohort study. PARTICIPANTS: A total of 299 eyes from 284 patients treated with DEX implant for DME (naïve, n = 209; refractory, n = 90). Baseline best-corrected visual acuity (BCVA) was between 0.3 and 1.0 on a logarithm of minimum angle of resolution visual chart. METHODS: The OCT scans previous to DEX implants were evaluated for submacular fluid, size and location of cystoid changes, inner segment-outer segment (IS-OS) continuity, quantity and location of hyperreflective foci (HRF), vitreomacular interface abnormalities, and epiretinal membrane. The BCVA and central macular thickness were recorded at baseline and at 1, 2, and 4 months after treatment with DEX implants. Correlations between OCT measures and visual outcome were analyzed using the generalized estimating equations procedure. MAIN OUTCOME MEASURES: The correlation between spectral-domain (SD) OCT measures at baseline and BCVA response (mean change from baseline; categorized improvement [<5, 5-9, or ≥10; Early Treatment Diabetic Retinopathy Study letters] in BCVA) after treatment with a DEX implant. RESULTS: The presence of subretinal fluid (odds ratio [OR], 1.98; 95% confidence interval [CI], 1.23-3.20; P = 0.01), absence of HRF (OR, 3.66; 95% CI, 1.40-9.62; P = 0.01), and integrity of the IS-OS layer (OR, 2.09; 95% CI, 1.30-3.37; P = 0.003) were all predictive of better visual outcome after treatment with DEX implants. Although eyes with naïve DME gained more vision than refractory eyes (P < 0.001), the predictive value of OCT findings did not differ according to this classification. CONCLUSIONS: Spectral-domain OCT is useful in identifying various imaging findings in DME. Among eyes with DME, those with submacular fluid, no HRF, and a continuous IS-OS layer responded better to DEX implants than those without these features. These findings call for further study of combinations of OCT and metabolic biomarkers.


Assuntos
Dexametasona/administração & dosagem , Retinopatia Diabética/complicações , Macula Lutea/patologia , Edema Macular/tratamento farmacológico , Tomografia de Coerência Óptica/métodos , Acuidade Visual , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 2/complicações , Retinopatia Diabética/diagnóstico , Retinopatia Diabética/tratamento farmacológico , Implantes de Medicamento , Feminino , Seguimentos , Glucocorticoides/administração & dosagem , Humanos , Injeções Intravítreas , Edema Macular/diagnóstico , Edema Macular/etiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA