RESUMO
This study evaluated the potential impact of different visualisation methods of cone-beam computed tomography (CBCT) on the accuracy of linear measurements of calcified structures, and assessed their interchangeability. High resolution (0.125 mm voxel) CBCT scans were obtained from eight cadaveric heads. The distance between the alveolar bone ridge and the incisal edge was determined for all mandibular incisors and canines, both anatomically and with measurements based on the following five CBCT visualisation methods: isosurface, direct volume rendering, multiplanar reformatting (MPR), maximum intensity projection of the volume of interest (VOIMIP), and average intensity projection of the volume of interest (VOIAvIP). All radiological methods were tested for repeatability and compared with anatomical results for accuracy, and limits of agreement were established. Interchangeability was evaluated by reviewing disparities between the methods and disclosing deterministic differences. Fine intra- and inter-observer repeatability was asserted for all visualisation methods (intraclass correlation coefficient ≤0.81). Measurements were most accurate when performed on MPR images and performed most disappointingly on isosurface-based images. Direct volume rendering, VOIMIP and VOIAvIP achieved acceptable results. It can be concluded that visualisation methods influence the accuracy of CBCT measurements. The isosurface viewing method is not recommended, and multiplanar reformatted images should be favoured for linear measurements of calcified structures.
Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Confiabilidade dos Dados , Humanos , Reprodutibilidade dos TestesRESUMO
BACKGROUND: The aim of the survey was to obtain information on the treatment plan preferences, mechanics and characteristics of temporary anchorage device (TAD) application using a single case presented to orthodontists in Switzerland. METHODS: A structured questionnaire to be completed by all study participants with case-specific (treatment plan including mechanics and TAD usage) and general questions (general fixed appliance and TAD usage as well as professional, educational and demographic questions) together with an orthodontic borderline case was utilised. The case was a female adult with dental Class II/2, deep bite and maxillary anterior crowing, who had been treated in childhood with extraction of four premolars and fixed appliance followed by wisdom tooth extraction. RESULTS: The response rate was 24.4% (108 out of 443). The majority (96.3%, 104) proposed comprehensive treatment, while 3.7% (4) planned only alignment of maxillary teeth. 8.3% (9) included a surgical approach in their treatment plan. An additional 0.9% (1) combined the surgical approach with Class II mechanics. 75.1% (81) decided on distalization on the maxilla using TADs, 7.4% (8) planned various types of Class II appliances and 3.7% (4) combined distalization using TADs or headgear with Class II appliances and surgery. Palatal implants were the most popular choice (70.6%, 60), followed by mini-screws (22.4%, 19) and mini-plates on the infrazygomatic crests (7.0%, 6). The preferred site of TAD insertion showed more variation in sagittal than in transversal dimension, and the median size of mini-screws used was 10.0-mm long (interquartile range (IQR) 2.3 mm) and 2.0-mm wide (IQR 0.3 mm). CONCLUSIONS: Distalization against palatal implants and then distalization against mini-screws were the most popular treatment plans. Preferred site for TAD insertion varied depending on type and size but varied more widely in the sagittal than in the transversal dimension.