Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Int J Cardiol ; 408: 132084, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38653434

RESUMO

BACKGROUND: In congenital aortic valve disease, quantifying aortic regurgitation (AR) varies by the measurement site. Our study aimed to identify the optimal site for AR assessment using 2D and 4D MR flow measurements, with a focus on vortices. METHODS: We retrospectively analysed 31 patients with congenital aortic valve disease, performing 2D and 4D MR flow measurements at the aortic valve, sinotubular junction (STJ), ascending aorta (AAo), and using midpulmonary artery measurements as a reference. We assessed percentage AR and net forward volumes, calculated linear correlations, and plotted Bland-Altman plots. Net forward flow at all aortic sites were correlated with the main pulmonary artery. Differences in AR between 2D and 4D flows were linked to vortices detected by 4D streamlines. RESULTS: The best agreement in % AR between 2D and 4D flows was at the aortic valve (mean difference 4D2D -2.9%, limits of agreement 8.7% to -14.3%; r2 = 0.7). Correlations weakened at STJ and AAo. Vortices in the ascending aorta led to AR overestimation in 2D measurements. Net forward flow at the aortic valve by 4D flow correlated closer with main pulmonary artery than did 2D flow. (Mean difference for 2D and 4D MR flow 7.5 ml and 4.2 ml, respectively). CONCLUSIONS: For congenital aortic valve disease, the most accurate AR quantification occurs at the aortic valve using 2D and 4D MR flow. Notably, vortices in the ascending aorta can result in AR overestimation with 2D MR flow.


Assuntos
Insuficiência da Valva Aórtica , Humanos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Estudos Retrospectivos , Feminino , Masculino , Adulto , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/anormalidades , Valva Aórtica/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Pessoa de Meia-Idade , Adolescente , Adulto Jovem , Criança , Valvopatia Aórtica/diagnóstico por imagem
2.
Cardiovasc Diagn Ther ; 12(3): 278-288, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35800351

RESUMO

Background: Cardiovascular magnetic resonance feature-tracking analysis (CMR-FT) provides a quantitative assessment of myocardial contraction with potential for diagnostic and prognostic ability in a wide spectrum of diseases. Ebstein's anomaly (EA) is a rare congenital heart disease characterized by apical displacement of the tricuspid valve. However, it is also considered a disorder of development affecting the global right ventricular myocardium. Aim of our study is to describe the complex contractile mechanics of the functional right ventricle (RV) in patients affected by EA through CMR-FT. Methods: Fifty surgery-free EA patients who had undergone a complete CMR protocol at our institution between January 2017 and December 2020 were selected for the retrospective study. A historical control group of twenty-five healthy subjects was also included. CMR-FT analysis was performed at a dedicated workstation by manually tracing RV endo- end epicardial borders on steady-state-free-precession (SSFP) cine images. Strain values were calculated. Apical displacement of the tricuspid valve (TV) was measured on a 4-chamber cine image from the right atrio-ventricular junction to the functional annulus of the TV. Results: EA patients presented significantly impaired RV global radial strain (GRS) and global circumferential strain (GCS) compared to controls (P<0.0001 and P=0.0008, respectively). In a subgroup analysis, GRS was significantly compromised in patients with a severely displaced TV (>16 mm/m2) compared to milder forms (P=0.03) and to controls (P<0.0001). Among EA patients with a preserved ejection fraction, 12 (48%) vs. 6 (24%) controls had reduced both GRS and GCS. Conclusions: The contractile pattern of the functional RV in EA is characterised by prevalent alterations in the short-axis direction as indicated by reduced GRS and GCS. Strain values might be reduced prior to routine used functional parameters like RV ejection fraction (RVEF) and can possibly serve as an early predictor of myocardial dysfunction in EA patients.

3.
J Magn Reson Imaging ; 55(6): 1843-1850, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34652053

RESUMO

BACKGROUND: Adolescents and adults with native Ebstein's anomaly (EA) are at the benign part of the Ebstein spectrum, having survived infancy without surgery. In this population, surgical indication and timing remain objects of controversy and depend, among other factors, on exercise capacity. PURPOSE: To better understand the pathophysiology of exercise adaptation in native EA. STUDY TYPE: Retrospective. POPULATION: Ten patients with unoperated EA (age range 18-61 years) and 13 healthy subjects as controls. FIELD STRENGTH/SEQUENCE: Balanced steady-state free precession cine and phase contrast flow sequences at 1.5 T. ASSESSMENT: We measured volumes and flows at rest and during submaximal exercise. Hemodynamic parameters including stroke volume (SV), cardiac index (CI), ejection fraction (EF), and tricuspid regurgitation (TR) were calculated. STATISTICAL TESTS: We used nonparametric Mann-Whitney U-test and Wilcoxon signed-rank test. A P-value of <0.05 was considered statistically significant. RESULTS: Rest CI and SV were significantly higher in controls; rest heart rate (HR) was similar in the two groups (median 71 bpm by patients and 65 bpm by controls, P = 0.448). During exercise, CI increased significantly in both groups: from 2.40 to 3.35 L/min/m2 in the patient group and from 3.60 to 4.20 L/min/m2 in controls; HR increased significantly in both groups. SV increased significantly in the patient group, whereas it remained stable in controls (P = 0.5284). Patients' median TR decreased significantly: median 42% at rest and 30% during exercise; concomitantly, left ventricular (LV) preload increased significantly (+3% indexed LV end-diastolic volume) as did LVEF (median 59% at rest vs. 65% during exercise). DATA CONCLUSION: During submaximal exercise, patients with mild to moderate EA improved their cardiovascular system's total efficiency by increasing CI; this was obtained by an increase in HR and by the recruitment of volume, as shown by an increased LV end-diastolic volume and SV, with simultaneous decrease in TR. This was different from healthy subjects in which CI increased only due to HR increase. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 3.


Assuntos
Anomalia de Ebstein , Insuficiência da Valva Tricúspide , Adolescente , Adulto , Anomalia de Ebstein/diagnóstico por imagem , Anomalia de Ebstein/epidemiologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Estudos Retrospectivos , Valva Tricúspide , Adulto Jovem
4.
J Cardiovasc Dev Dis ; 8(10)2021 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-34677188

RESUMO

Objective: To investigate a high-pitch spiral first (HPSF) approach for coronary computed tomography angiography (CCTA) in an unselected patient cohort and compare diagnostic yield and radiation exposure to CCTAs acquired via conventional, non-high-pitch spiral first (NHPSF) scan regimes. Materials and Methods: All consecutive patients from 1 January 2015 to 31 December 2017 were included. Two investigation protocols (HPSF/NHPSF) were used with the aim to achieve diagnostic image quality of all coronary segments. Low-pitch secondary scans followed the initial examination if image quality was unsatisfactory. Dosage and image quality were compared between both regimes. Results: 1410 patients were subject to a HPSF and 236 patients to a NHPSF approach. While the HPSF approach led to a higher fraction of re-scans (35% vs. 11%, p < 0.001), the fraction of aggregate scans that remained non-diagnostic after considering the initial and secondary scan was comparably low for the HPSF and NHPSF approach (0.78 vs. 0%, p = 0.18). Aggregate radiation exposure in the HPSF protocol was significantly lower (1.12 mSv (IQR: 0.73, 2.10) vs. 3.96 mSv (IQR: 2.23, 8.33) p < 0.001). Conclusions: In spite of a higher number of re-scans, a HPSF approach leads to a reduction in overall radiation exposure with diagnostic yields similar to a NHPSF approach.

5.
Cardiovasc Diagn Ther ; 11(6): 1356-1366, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35070804

RESUMO

BACKGROUND: The aim of this study was to test a CE-certified MR-conditional guidewire to facilitate blood pressure measurement in cardiovascular magnetic resonance (CMR) using fluid-filled catheters in patients with congenital heart disease (CHD). The main purpose was to determine procedural success in a post market clinical follow-up (PMCF) for routine procedure in a diagnostic and interventional workflow. Real-time CMR provides high quality imaging without the risk of exposing the patient to X-rays, especially for patients with irregular heart anatomy and patients who are susceptible to radiation and iodinated contrast media. To date, the assessment of blood pressure gradients is not a common feature of CMR, as these gradients cannot be accurately evaluated in routine CMR. METHODS: Twenty-five CHD patients who were planned for combined clinical CMR and diagnostic and/or interventional catheterization were enrolled in the trial. Prior to inclusion, a specific procedure for catheterization in CMR was defined, encompassing the assessment of pressure and pressure gradients in the heart and great vessels. RESULTS: By the use of an MR-conditional guidewire we successfully measured specific pressure and pressure gradients in up to 92% of cases with liquid-filled catheters which were guided exclusively under CMR guidance. There were no guidewire-related adverse events, and guidewire guidance and manipulation of catheters were successful. CONCLUSIONS: Using a MR-conditional guidewire assists in easily reaching targets in the heart and great vessels and makes the catheter itself visible, so that invasive blood pressure assessment by CMR guidance with liquid-filled catheters can be improved. KEYWORDS: Cardiovascular magnetic resonance (CMR); congenital heart disease (CHD); cardiac catheterization; magnetic resonance; pressure; guidewire.

6.
Pediatr Cardiol ; 41(5): 862-868, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32095853

RESUMO

Sudden cardiac death (SCD) is the most common cause of late mortality in tetralogy of Fallot (TOF). Pulmonary regurgitation (PR) was previously found to be the most common hemodynamic abnormality associated with ventricular arrhythmias (VA), but cardiovascular magnetic resonance (CMR)-based studies did not show this association. The aim of this study is to investigate the risk factors for VA in TOF using CMR. Electronic records of TOF patients and their CMR studies between July 2006 and October 2018 in one center were retrospectively reviewed. Demographic, clinical and CMR data of patients were collected. Outcome was defined as sustained ventricular tachycardia (VT), aborted SCD and SCD. From a total of 434 TOF patients with complete CMR studies, 19 (4.4%) patients developed a positive outcome (12 sustained VT, 4 aborted SCD, 3 SCD) at a median age of 24 years. The number of surgical interventions was significantly greater in patients who developed VA. Right ventricular volumes were significantly larger in patients who suffered a positive outcome. Odds ratio for developing VA was 6.905 for RVEDVI ≥ 160 ml/m2 and 6.141 for RVESVI ≥ 80 ml/m2 (P = 0.0014 and 0.0012, respectively). Event-free survival was longer in patients with smaller right ventricular volumes. In conclusion, right ventricular dimensions are the most significant factors associated with the development of VA in TOF. The number of surgical interventions is also related to an increased risk.


Assuntos
Arritmias Cardíacas/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tetralogia de Fallot/cirurgia , Adolescente , Adulto , Arritmias Cardíacas/complicações , Arritmias Cardíacas/mortalidade , Procedimentos Cirúrgicos Cardíacos/métodos , Morte Súbita Cardíaca/etiologia , Feminino , Ventrículos do Coração/patologia , Hemodinâmica , Humanos , Masculino , Insuficiência da Valva Pulmonar/etiologia , Estudos Retrospectivos , Fatores de Risco , Taquicardia Ventricular/complicações , Taquicardia Ventricular/diagnóstico , Tetralogia de Fallot/complicações , Tetralogia de Fallot/diagnóstico , Tetralogia de Fallot/mortalidade , Adulto Jovem
7.
Neuropediatrics ; 51(1): 57-61, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31505689

RESUMO

We present a 7-year-old boy with tuberous sclerosis and congenital segmental lymphedema (CSL) of the left leg, as well as two aortic aneurysms. He was treated with everolimus (EVE) since the age of 14 months. His CSL regressed under treatment with EVE. His first aneurysms required operative intervention at age of 17 months. Four months afterward a new aortic aneurysm had been detected above the Dracon graft, but this one remained stable since that time. The patient didn't experience severe side effects. EVE has been well tolerated without disturbance of somatic growth or serious adverse effect.


Assuntos
Aneurisma Aórtico/etiologia , Linfedema/congênito , Proteína 2 do Complexo Esclerose Tuberosa/genética , Esclerose Tuberosa/complicações , Esclerose Tuberosa/genética , Antineoplásicos/farmacologia , Criança , Everolimo/farmacologia , Humanos , Masculino , Esclerose Tuberosa/tratamento farmacológico
8.
Pediatr Cardiol ; 40(4): 792-798, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30726509

RESUMO

BACKGROUND: Exercise capacity is a well-defined marker of outcome in congenital heart disease. We analyzed seventeen cardiovascular magnetic resonance (CMR) derived parameters and their correlation to exercise capacity in patients with Ebstein's anomaly (EA). METHODS: Fifty-four surgery free patients, age 5 to 69 years (median 30 years) prospectively underwent CMR examination and cardiopulmonary exercise testing (CPET). The following volume/flow parameters were compared with peak oxygen uptake as the percentage of normal (peakVO2%) using univariate and multivariate analysis: right and left ventricular ejection fraction (RVEF and LVEF), the indexed end-diastolic and end-systolic volumes (RVEDVi, RVESVi, LVEDVi, and LVESVi), the indexed stroke volumes (RVSVi and LVSVi), the total normalized right and left heart volumes; the total right to left heart volume ratio (R/L-ratio). The indexed antegrade flow (ante), indexed net flow (net) as well as cardiac index (CI) in the aorta (Ao) and pulmonary artery (PA) were used. RESULTS: RVEF (R2 0.2788), indexed flow PA net (R2 0.2330), and PA ante (R2 0.1912) showed the best correlation with peakVO2% (all p < 0.001) in the univariate model. Further significant correlation could also be demonstrated with CI-PA, LVEF, LVSVi, Aorta net, RVESVi, and Aorta ante. Multivariate analysis for RVEF and indexed net flow PA revealed a R2 of 0.4350. CONCLUSION: Functional CMR parameters as RVEF and LVEF and flow data of cardiac forward flow correlate to peakVO2%. Evaluation of the indexed net flow in the pulmonary artery and the overall function of the right ventricle best predicts the maximal exercise capacity in patients with EA.


Assuntos
Anomalia de Ebstein/diagnóstico por imagem , Tolerância ao Exercício/fisiologia , Coração/diagnóstico por imagem , Hemodinâmica/fisiologia , Imagem Cinética por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Biomarcadores , Criança , Pré-Escolar , Anomalia de Ebstein/fisiopatologia , Teste de Esforço/métodos , Feminino , Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio/fisiologia , Estudos Prospectivos , Adulto Jovem
9.
Pediatr Cardiol ; 39(1): 105-110, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28948316

RESUMO

The assumption of the presence of diffuse myocardial fibrosis in long-standing cyanotic congenital heart disease (CHD) inspired us to noninvasively determine the myocardial extracellular volume (ECV) using contrast CMR. T1 maps were measured pre and 10 min after the injection of 0.15 mmol/kg of gadolinium in 25 subjects. Seven patients with long-standing cyanotic CHD and no previous cardiac surgery (aged 16-53 years and oxygen saturations of 69-90%), nine normal subjects (aged 14-49 years), and nine patients with previously cyanotic CHD, who had been corrected by open heart surgery (aged 2 months-58 years, mean 9 years). Late gadolinium enhancement was performed to exclude scar areas. The T1 values were measured in the interventricular septum and in the left lateral or inferior ventricular wall, such that same areas were assessed in every patient in the pre- and post-contrast T1 scan. ECV was calculated according to ΔR1myocardium/ΔR1blood * (1 - hematocrit). Cyanotic patients had significantly lower ECV percentage than the previous cyanotic patients (septum: 22 ± 2.7% vs 35 ± 4.6%, p = 0.002; LV wall: 22 ± 2.2% vs 30 ± 3.7%, p = 0.01, respectively). No significant differences were found between cyanotic patients and normal controls (septum: 22 ± 2.7% vs 24 ± 1.4%, p = 0.44; LV wall: 22 ± 2.2% vs 24 ± 2%, p = 0.57, respectively). Long-standing cyanosis in CHD without cardiac surgery does not cause diffuse myocardial fibrosis or expansion of the myocardial ECV.


Assuntos
Cianose/complicações , Cardiopatias Congênitas/complicações , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio/patologia , Adolescente , Adulto , Criança , Pré-Escolar , Espaço Extracelular/diagnóstico por imagem , Feminino , Fibrose , Gadolínio , Cardiopatias Congênitas/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Adulto Jovem
10.
J Magn Reson Imaging ; 46(6): 1839-1845, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28301100

RESUMO

PURPOSE: To compare the quantification of pulmonary stroke volume (SV) by phase contrast magnetic resonance (PC-MR) in the main pulmonary artery (MPA) to the sum of SVs in both peripheral pulmonary arteries (PPA) in different right ventricular (RV) outflow pathologies. MATERIALS AND METHODS: Pulmonary SV was determined by PC-MR in the MPA and the PPA in healthy individuals (H, n = 54), patients after correction for tetralogy of Fallot with significant pulmonary regurgitation and without pulmonary or RV outflow tract stenosis (PR, n = 50), and in patients with RV outflow tract or pulmonary valve stenosis (PS, n = 50). Resulting SVs were compared to aortic SV in the ascending aorta. RESULTS: Mean age was similar between the groups: H 28 ± 17 vs. PR 24 ± 11 vs. PS 22 ± 10 years. Bland-Altman analyses revealed in all groups a relatively small systemic (bias) but large random error (limits of agreement) for pulmonary SV determined in the MPA as compared to summed SVs in the PPA. The largest limits of agreement were present in PS patients: H: MPA 3.9% (-11, + 19) vs. PPA 0.4% (-15, + 15); PR: MPA 5.2% (-25, + 36) vs. PPA 0.6% (-24, + 26); PS: MPA 5% (-36; + 46), PPA -0.03% (-34, + 35). CONCLUSION: The accuracy of PC-MR in the MPA is reasonable; however, a large random error (precision) is observed that is most pronounced in PS patients. This potential error should be taken into consideration when interpreting MPA flow measurements. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:1839-1845.


Assuntos
Imageamento por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Direita/cirurgia , Adulto , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Complicações Pós-Operatórias/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/fisiopatologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Volume Sistólico/fisiologia , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/fisiopatologia , Adulto Jovem
11.
Int J Cardiovasc Imaging ; 33(4): 569-576, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27848163

RESUMO

Coronary CT angiography (CCTA) suffers from a reduced diagnostic accuracy in patients with heavily calcified coronary arteries or prior myocardial revascularisation due to artefacts caused by calcifications and stent material. CT myocardial perfusion imaging (CTMPI) yields high potential for the detection of myocardial ischemia and might help to overcome the above mentioned limitations. We analysed CT single-phase perfusion using high-pitch helical image acquisition technique in patients with prior myocardial revascularisation. Thirty-six patients with an indication for invasive coronary angiography (28 with coronary stents, 2 with coronary artery bypass grafts and 6 with both) were included in this prospective study at two study sites. All patients were examined on a 2nd generation dual-source CT system. Stress CT images were obtained using a prospectively ECG-triggered single-phase high-pitch helical image acquisition technique. During stress the tracer for myocardial perfusion (MP) SPECT imaging was administered. Rest CT images were acquired using prospectively ECG-triggered sequential CT. MP-SPECT imaging and invasive coronary angiography served as standard of reference. In this heavily diseased patient cohort CCTA alone showed a low overall diagnostic accuracy for detection of hemodynamically relevant coronary artery stenosis of only 31% on a per-patient base and 60% on a per-vessel base. Combining CCTA and CTMPI allowed for a significantly higher overall diagnostic accuracy of 78% on a per-patient base and 92% on a per-vessel base (p < 0.001). Mean radiation dose for stress CT scans was 0.9 mSv, mean radiation dose for rest CT scans was 5.0 mSv. In symptomatic patients with known coronary artery disease and prior myocardial revascularization combining CCTA and CTMPI showed significantly higher diagnostic accuracy in detection of hemodynamically significant coronary artery stenosis when compared to CCTA alone.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Circulação Coronária , Isquemia Miocárdica/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada Espiral , Idoso , Idoso de 80 Anos ou mais , Ponte de Artéria Coronária , Eletrocardiografia , Feminino , Alemanha , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/terapia , Intervenção Coronária Percutânea/instrumentação , Valor Preditivo dos Testes , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Stents
12.
JACC Cardiovasc Imaging ; 8(8): 888-96, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26189118

RESUMO

OBJECTIVES: The purpose of this study was to assess the potential of iterative image reconstruction (IR) of images for radiation dose reduction in coronary computed tomography angiography (CTA). Therefore, IR in combination with 30% tube current reduction was compared with standard scanning with filtered back projection (FBP) reconstruction. BACKGROUND: Lately, new IR techniques with advanced raw data processing have been introduced by different computed tomography vendors, thus allowing for either image noise reduction at unchanged radiation dose levels or radiation dose reductions at comparable image noise levels. METHODS: In this prospective, multicenter, multivendor noninferiority trial, we randomized 400 consecutive patients to 1 of 2 groups: a control group using standard FBP image reconstruction and standard tube current or an interventional group using IR technique and 30% tube current reduction. The primary endpoint was to demonstrate noninferiority in image quality (IQ) in the IR group. IQ was assessed on a 4-point scale (1, nondiagnostic IQ; 4, excellent IQ). Secondary endpoints included total radiation dose estimates and the rate of downstream testing during 30-day follow-up. RESULTS: Median IQ in the IR group was noninferior compared with the conventional FBP group (IR, 3.5 [interquartile range: 3.0 to 4.0]; FBP, 3.4 [interquartile range: 2.8 to 4.0], p for noninferiority <0.016). The radiation exposure was significantly lower in the IR group (median dose-length-product 157 [interquartile range: 114 to 239] mGy·cm vs. 222 [interquartile range: 141 to 319] mGy·cm for IR vs. FBP, respectively, p < 0.0001). The rate of downstream testing did not differ significantly (7.7% vs. 7.9% for IR vs. FBP, respectively, p = 0.94). CONCLUSIONS: Coronary CTA image quality is maintained with the combined use of a 30% reduced tube current and IR algorithms when compared with conventional FBP image reconstruction techniques and standard tube current. (Prospective Randomized Trial On RadiaTion Dose Estimates Of CT AngIOgraphy In PatieNts: NCT01453712).


Assuntos
Angiografia Coronária , Processamento de Imagem Assistida por Computador , Doses de Radiação , Tomografia Computadorizada por Raios X , Algoritmos , Densovirinae , Estudos Prospectivos
13.
J Cardiovasc Comput Tomogr ; 9(4): 278-85, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25926015

RESUMO

BACKGROUND: Concerns have been raised about radiation dose of coronary CT angiography. Although high-pitch acquisition technique yields high potential for radiation dose savings, it is more vulnerable to artifacts, which impair diagnostic image quality. OBJECTIVE: The purpose of this study was to compare 2 scan strategies for coronary CT angiography: a high-pitch helical scan first or a conventional scan first strategy. METHODS: In this prospective, multicenter trial, we randomized 303 consecutive patients with a low and stable heart rate to either of the aforementioned mentioned strategies. Intravenous ß-blockers were administered to achieve target heart rates. All scans were performed on a second-generation dual-source CT scanner. In case of nondiagnostic image quality, coronary CT angiography was allowed to be repeated. The primary end point was to demonstrate noninferior image quality in the high-pitch group. Image quality was assessed on a 4-point scale (1: nondiagnostic, 4: excellent). Secondary end point was total radiation dose. RESULTS: In the high-pitch helical first group, repeat scanning was necessary in 21 patients compared with 14 patients in the conventional first scan group (P = .25). Image quality in the high-pitch group was noninferior compared to the conventional scan group (3.81 ± 0.35 vs. 3.83 ± 0.37; P for noninferiority <.0001). The total effective radiation dose estimate was 58% lower in the high-pitch group (2.0 ± 2.4 vs. 4.7 ± 4.8 mSv; P < .0001). CONCLUSIONS: In patients with a low and stable heart rate diagnostic image quality can be maintained with a high-pitch helical scan first strategy while 58% of radiation dose can be saved.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doses de Radiação , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Int J Cardiol ; 167(1): 258-61, 2013 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-22280553

RESUMO

BACKGROUND: The size of the functional right ventricle of patients with Ebstein's anomaly is, according to contemporary opinion, small. However, the in vivo size of the functional right ventricle in patients with Ebstein's anomaly is unknown. Furthermore, it is unknown how the apical displacement and regurgitant fraction of the tricuspid valve in Ebstein's anomaly affects the size of the functional right ventricle. Therefore the primary aim of this study was to determine the volume of the functional right ventricle in patients with Ebstein's anomaly. The secondary aim of this study was to assess correlation of the volume of the functional right ventricle to the apical displacement and regurgitant fraction of the tricuspid valve. METHODS: Thirty-two consecutive patients with Ebstein's anomaly without previous cardiac surgery or shunts were studied prospectively by cardiovascular magnetic resonance. Functional right ventricle, left ventricle, and atrialized right ventricle volumes and tricuspid valve regurgitation were measured. RESULTS: Functional right ventricle end diastolic volumes were median 127 ml/m² (range: 76-339 ml/m²) and were median 2.5 (range: 1.3-8.8) times larger than the left ventricle volumes. Furthermore, functional right ventricle volumes correlated in a strong positive fashion with tricuspid valve regurgitation (p<0.001, R(2)=0.65) and modestly with the atrialized right ventricle volumes (p=0.027, R(2)=0.16). CONCLUSION: Patients with untreated Ebstein's anomaly have large functional right ventricles. The size of the enlarged functional right ventricle seems to depend on the degree of tricuspid valve regurgitation and not on the size of the atrialized right ventricle or the age of the patient.


Assuntos
Anomalia de Ebstein/diagnóstico , Anomalia de Ebstein/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/fisiopatologia , Função Ventricular Direita/fisiologia , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Anomalia de Ebstein/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Insuficiência da Valva Tricúspide/epidemiologia , Adulto Jovem
15.
JACC Cardiovasc Imaging ; 5(5): 484-93, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22595156

RESUMO

OBJECTIVES: The purpose of this study was to evaluate image quality and radiation dose using a prospectively electrocardiogram (ECG)-triggered axial scan protocol compared with standard retrospective ECG-gated helical scanning for coronary computed tomography angiography. BACKGROUND: Concerns have been raised regarding radiation exposure during coronary computed tomography angiography. Although the use of prospectively ECG-triggered axial scan protocols may effectively lower radiation dose compared with helical scanning, it is unknown whether image quality is maintained in a clinical setting. METHODS: In a prospective, multicenter, multivendor trial, 400 patients with low and stable heart rates were randomized to either an axial or a helical coronary computed tomography angiography scan protocol. The primary endpoint was to demonstrate noninferiority in image quality with the axial scan protocol, which was assessed on a 4-point scale (1 = nondiagnostic, 4 = excellent image quality). Secondary endpoints included radiation dose and the rate of downstream testing during 30-day follow-up. RESULTS: Image quality in patients scanned with the axial scan protocol (score 3.36 ± 0.59) was not inferior compared with helical scan protocols (3.37 ± 0.59) (p for noninferiority <0.004). Axial scanning was associated with a 69% reduction in radiation exposure (dose-length product [estimated effective dose] 252 ± 147 mGy · cm [3.5 ± 2.1 mSv] vs. 802 ± 419 mGy · cm [11.2 ± 5.9 mSv] for axial vs. helical scan protocols, p < 0.001). The rate of downstream testing did not differ (13.8% vs. 15.9% for axial vs. helical scan protocols, p = 0.555). CONCLUSIONS: In patients with stable and low heart rates, the prospectively ECG-triggered axial scan protocol maintained image quality but reduced radiation exposure by 69% compared with helical scanning. Axial computed tomography data acquisition should be strongly recommended in suitable patients to avoid unnecessarily high radiation exposure.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Eletrocardiografia , Doses de Radiação , Tomografia Computadorizada Espiral , Argentina , Índice de Massa Corporal , Distribuição de Qui-Quadrado , Doença da Artéria Coronariana/fisiopatologia , Europa (Continente) , Frequência Cardíaca , Humanos , Japão , Valor Preditivo dos Testes , Prognóstico , Fatores de Tempo
16.
Eur Heart J Cardiovasc Imaging ; 13(6): 468-75, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22166591

RESUMO

AIMS: The extent of coronary artery calcification (CAC) has been shown to be a strong and independent predictor for cardiovascular events. Usually, CAC scoring is performed in non-contrast-enhanced computed tomography (CT) examinations. The ability and accuracy of cardiovascular risk classification according to the degree of CAC determined in contrast-enhanced coronary CT angiography (CCTA) has not been investigated so far. The aim of this analysis was to develop and validate a method for CAC risk classification in CCTA. METHODS AND RESULTS: In a test series of 100 patients who underwent both non-enhanced CAC scoring and CCTA, we developed a method to assess the extent of coronary calcification and the associated cardiovascular risk category in CCTA. The accuracy of the developed approach of CAC assessment in CCTA was determined in 500 consecutive patients in comparison to CAC scoring in the non-enhanced scan. CAC scoring results in the non-enhanced scan and CCTA scan showed a high correlation (r = 0.954; P < 0.001). CAC quantification in CCTA correctly identified 98% of patients without CAC as shown in the non-enhanced scan (184 of 188 patients). When compared with non-enhanced CAC scoring, CAC scoring in CCTA grouped more than 95% of high-risk patients correctly into the same risk category according to the 75th age- and gender-specific percentiles or the absolute calcium scores. CONCLUSION: Assessing cardiovascular risk associated with CAC is feasible and accurate in contrast-enhanced CCTA. This new technique may allow for reducing the radiation exposure of coronary CT studies while maintaining an accurate cardiovascular risk assessment, because the addition of non-enhanced scans to CCTA becomes unnecessary for comprehensive coronary CT studies.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia Coronária/métodos , Doença das Coronárias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Estatísticas não Paramétricas
18.
Circ Cardiovasc Imaging ; 4(1): 16-23, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20884832

RESUMO

BACKGROUND: Several studies have demonstrated a high accuracy of coronary computed tomography angiography (CCTA) for detection of obstructive coronary artery disease (CAD), whereas some studies have also shown a good prediction of cardiac events. However, it remains to be proven whether CCTA is better predictive of events than conventional risk scores or calcium scoring. Therefore, we compared CCTA with calcium scoring and clinical risk scores for the ability to predict cardiac events. METHODS AND RESULTS: Patients (n=2223) with suspected CAD undergoing CCTA were followed up for a median of 28 months. The end point was the occurrence of cardiac events (cardiac death, nonfatal myocardial infarction, unstable angina requiring hospitalization, and coronary revascularization later than 90 days after CCTA). Patients with obstructive CAD had a significantly higher event rate (2.9% per year; 95% confidence interval, 2.1 to 4.0) than those without obstructive CAD, having an event rate 0.3% per year (95% confidence interval, 0.1 to 0.5; hazard ratio, 13.5; 95% confidence interval, 6.7 to 27.2; P<0.001). CCTA had significant incremental predictive value when compared with calcium scoring, both with scores assessing the degree of stenosis (P<0.001) and with scores assessing the number of diseased coronary segments (P=0.027). CONCLUSIONS: In patients with suspected CAD, CCTA not only detects coronary stenosis but also improves prediction of cardiac events over and above conventional risk scores and calcium scoring. This may result in a reclassification of cardiovascular risk in a substantial proportion of patients.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Calcinose/complicações , Meios de Contraste , Doença da Artéria Coronariana/complicações , Estenose Coronária/complicações , Estenose Coronária/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Fatores de Risco , Índice de Gravidade de Doença
19.
JACC Cardiovasc Imaging ; 3(11): 1113-23, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21070998

RESUMO

OBJECTIVES: The purpose of this study was to evaluate image quality and radiation dose using a 100 kVp tube voltage scan protocol compared with standard 120 kVp for coronary computed tomography angiography (CTA). BACKGROUND: Concerns have been raised about radiation exposure during coronary CTA. The use of a 100 kVp tube voltage scan protocol effectively lowers coronary CTA radiation dose compared with standard 120 kVp, but it is unknown whether image quality is maintained. METHODS: We enrolled 400 nonobese patients who underwent coronary CTA: 202 patients were randomly assigned to a 100 kVp protocol and 198 patients to a 120 kVp protocol. The primary end point was to demonstrate noninferiority in image quality with the 100 kVp protocol, which was assessed by a 4-point grading score (1 = nondiagnostic, 4 = excellent image quality). For the noninferiority analysis, a margin of -0.2 image quality score points for the difference between both scan protocols was pre-defined. Secondary end points included radiation dose and need for additional diagnostic tests during follow-up. RESULTS: The mean image quality scores in patients scanned with 100 kVp and 120 kVp were 3.30 ± 0.67 and 3.28 ± 0.68, respectively (p = 0.742); image quality of the 100 kVp protocol was not inferior, as demonstrated by the 97.5% confidence interval of the difference, which did not cross the pre-defined noninferiority margin of -0.2. The 100 kVp protocol was associated with a 31% relative reduction in radiation exposure (dose-length product: 868 ± 317 mGy × cm with 120 kVp vs. 599 ± 255 mGy × cm with 100 kVp; p < 0.0001). At 30-day follow-up, the need for additional diagnostic studies did not differ (13.4% vs. 19.2% for 100 kVp vs. 120 kVp, respectively; p = 0.114). CONCLUSIONS: A coronary CTA protocol using 100 kVp tube voltage maintained image quality, but reduced radiation exposure by 31% as compared with the standard 120 kVp protocol. Thus, 100 kVp scan protocols should be considered for nonobese patients to keep radiation exposure as low as reasonably achievable. (Prospective Randomized Trial on Radiation Dose Estimates of Cardiac CT Angiography in Patients Scanned With a 100 kVp Protocol [PROTECTION II]; NCT00611780).


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X , Idoso , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador
20.
AJR Am J Roentgenol ; 194(6): 1495-9, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20489088

RESUMO

OBJECTIVE: Concerns have been raised about the radiation exposure of coronary CT angiography (CTA). Recently, a prospective ECG-triggered sequential coronary CTA technique was developed to reduce exposure to ionizing radiation. The purpose of this analysis was to determine the impact of a sequential scanning technique on image quality and radiation dose in a prespecified subgroup analysis of the Prospective Multicenter Study on Radiation Dose Estimates of Cardiac CT Angiography I (PROTECTION I) Study when compared with a standard helical scanning technique. MATERIALS AND METHODS: This analysis comprises 685 64-MDCT coronary angiography studies of 47 international study sites in which the image quality was assessed by an experienced coronary CTA investigator using a 4-point score (1 = nondiagnostic, 4 = excellent image quality). Image quality was analyzed in all patients studied with the sequential scanning mode (n = 99) and in randomly selected patients of the population studied with the helical acquisition mode (n = 586). Radiation dose estimates were derived from the dose-length product (DLP) and a conversion coefficient for the chest (0.014 mSv x mGy(-1) x cm(-1)). RESULTS: Although the sequential scanning mode significantly reduced radiation dose estimates by 68% from 11.2 mSv for the helical mode to 3.6 mSv for the sequential mode (p < 0.001), the median diagnostic image quality scores were comparable in both groups. The median diagnostic score for both scanning modes was 3.5 (interquartile range: sequential vs helical mode, 3.25-3.75 vs 3.0-3.75, respectively; p = 0.62). CONCLUSION: The results of the PROTECTION I Study suggest that the prospective ECG-triggered sequential coronary CTA technique significantly reduces radiation dose without impairing image quality when compared with the standard retrospective helical data acquisition in patients with a low and stable heart rate.


Assuntos
Angiografia Coronária/métodos , Doença das Coronárias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Distribuição de Qui-Quadrado , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Estatísticas não Paramétricas , Tomografia Computadorizada Espiral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA