Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Invest Radiol ; 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38529924

RESUMO

OBJECTIVES: This phantom and animal pilot study aimed to compare image quality and radiation exposure between detector-dose-driven exposure control (DEC) and contrast-to-noise ratio (CNR)-driven exposure control (CEC) as functions of source-to-image receptor distance (SID) and collimation. MATERIALS AND METHODS: First, an iron foil simulated a guide wire in a stack of polymethyl methacrylate and aluminum plates representing patient thicknesses of 15, 25, and 35 cm. Fluoroscopic images were acquired using 5 SIDs ranging from 100 to 130 cm and 2 collimations (full field of view, collimated field of view: 6 × 6 cm). The iron foil CNRs were calculated, and radiation doses in terms of air kerma rate were obtained and assessed using a multivariate regression. Second, 5 angiographic scenarios were created in 2 anesthetized pigs. Fluoroscopic images were acquired at 2 SIDs (110 and 130 cm) and both collimations. Two blinded experienced readers compared image quality to the reference image using full field of view at an SID of 110 cm. Air kerma rate was obtained and compared using t tests. RESULTS: Using DEC, both CNR and air kerma rate increased significantly at longer SID and collimation below the air kerma rate limit. When using CEC, CNR was significantly less dependent of SID, collimation, and patient thickness. Air kerma rate decreased at longer SID and tighter collimation. After reaching the air kerma rate limit, CEC behaved similarly to DEC. In the animal study using DEC, image quality and air kerma rate increased with longer SID and collimation (P < 0.005). Using CEC, image quality was not significantly different than using longer SID or tighter collimation. Air kerma rate was not significantly different at longer SID but lower using collimation (P = 0.012). CONCLUSIONS: CEC maintains the image quality with varying SID and collimation stricter than DEC, does not increase the air kerma rate at longer SID and reduces it with tighter collimation. After reaching the air kerma rate limit, CEC and DEC perform similarly.

2.
Sci Rep ; 13(1): 22814, 2023 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-38129493

RESUMO

Persistent Genital Arousal Disorder (PGAD) is a rare condition-mostly in women-where patients perceive prolonged genital arousal without any sexual desire or stimulation. Etiopathological considerations reach from peripheral to central issues over local disturbance of the pudendal nerve to neuropathy, psychosocial, and pharmacological theories. Since well controlled clinical studies about PGAD in conjunction with a mental and somatic health status are missing, this study is a detailed clinical investigation of PGAD patients compared to healthy controls. 26 women who fulfilled diagnostic criteria for PGAD were compared to 26 age matched healthy controls. Investigations included comparison of vegetative, gynaecological and sexual history, psychiatric features as well as a (neuro-)radiological, neurophysiological and gynaecological examination. Moreover, a detailed clinical characterisation of PGAD symptoms was performed. PGAD symptoms were mostly characterised as tingling or prickling and were permanently present. In over 80%, PGAD symptoms were located in the clitoris. Almost 70% reported radiations to other regions of the body. Most frequent trigger factors were tight clothes, mental stress, driving a car/bus/bicycle and sexual intercourse. Relieving factors were mainly distraction, relaxation, physical exercise, masturbation and swimming. In group comparisons, PGAD presented with significant higher rates of sexual dysfunctions, spontaneous orgasms, swelling of the genitals, extraordinary lubrication as well as higher rates in depression, agoraphobia, generalized anxiety disorder and lifetime panic disorder. Significantly more PGAD patients were diagnosed with restless legs symptoms. In contrast childhood traumatization, somatization disorder, suicidality, gynaecological as well as neurophysiological examination of the pudendal nerve were not different between the groups. MRI of the brain, pelvis and spinal cord was unsuspicious and incidental findings - including Tarlov cysts or pelvic venous congestion - were equally distributed among the groups. In summary, our study provides a careful characterization of women with PGAD highlighting a serious mental burden, most probably as a consequence of PGAD. With the current set of clinical investigations there was no evidence of a clear causal relationship to a specific clinical finding as it has been previously discussed. Future studies and additional techniques will have to further explore where and how in the peripheral or central nervous systems PGAD develops.


Assuntos
Disfunções Sexuais Fisiológicas , Feminino , Humanos , Disfunções Sexuais Fisiológicas/etiologia , Comportamento Sexual/psicologia , Genitália , Nível de Alerta/fisiologia , Coito , Dor Pélvica
3.
Clin Exp Metastasis ; 40(1): 95-104, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36417096

RESUMO

Cholangiocarcinoma (CCA) are the second most common primary liver tumors and carry a dismal prognosis. Chemosaturation with percutaneous hepatic perfusion (PHP) is a palliative, intra-arterial therapeutic approach that provides a high dose chemotherapy of the liver with reduced systemic exposure. Aim of this retrospective, monocentric study was to analyze PHP as a palliative treatment for unresectable CCA. Toxicity, adverse events and complications were classified using the Common Terminology Criteria for Adverse Events (CTCAE v5.0). Overall response rate (ORR) and disease control rate (DCR) were evaluated according to the Response Evaluation Criteria in Solid Tumors (RECIST1.1). Median overall survival (mOS), median progression-free survival (mPFS) and hepatic mPFS (mhPFS) were computed using Kaplan-Meier estimation. In total 17 patients were treated with 42 PHP between 10/2014 and 09/2020. No significant complications occurred during the interventions. mOS was 27.6 (interquartile range (IQR) 16.5-37) months from first diagnosis and 9.9 (IQR 3.8-21) months from first PHP. mPFS was 4 (IQR 2-7) and mhPFS was 4 (IQR 3-10) months. ORR was 25% and DCR 75%. Significant, but transient hematotoxicity was frequent with grade 3/4 thrombopenia after 50%, leukopenia after 26% and anaemia after 21% of the interventions. An increase of transaminases (AST increase after 21% and ALT increase after 14% of the PHP) developed more often than a deterioration of the liver synthesis capacity. Salvage treatment with PHP has the potential to prolong life in selected patients with unresectable, refractory cholangiocarcinoma. The interventional procedure is safe. Post-interventional toxicity is frequent but manageable.


Assuntos
Neoplasias dos Ductos Biliares , Colangiocarcinoma , Neoplasias Hepáticas , Humanos , Melfalan , Quimioterapia do Câncer por Perfusão Regional/métodos , Estudos Retrospectivos , Cuidados Paliativos , Neoplasias Hepáticas/tratamento farmacológico , Colangiocarcinoma/tratamento farmacológico , Neoplasias dos Ductos Biliares/tratamento farmacológico , Ductos Biliares Intra-Hepáticos , Perfusão
4.
Cancer Imaging ; 22(1): 37, 2022 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-35908026

RESUMO

BACKGROUND: To evaluate effectivity of a 3D-motion correction algorithm in C-Arm CTs (CACT) with limited image quality (IQ) during transarterial chemoembolization (TACE). METHODS: From 1/2015-5/2021, 644 CACTs were performed in patients during TACE. Of these, 27 CACTs in 26 patients (18 m, 8f; 69.7 years ± 10.7 SD) of limited IQ were included. Post-processing of the original raw-data sets (CACTOrg) included application of a 3D-motion correction algorithm and bone segmentation (CACTMC_no_bone). Four radiologists (R1-4) compared the images by choosing their preferred dataset and recommending repeat acquisition in case of severe IQ-impairment. R1,2 performed additional grading of intrahepatic vessel visualization, presence/extent of movement artifacts, and overall IQ. RESULTS: R1,2 demonstrated excellent interobserver agreement for overall IQ (ICC 0.79,p < 0.01) and the five-point vessel visualization scale before and after post-processing of the datasets (ICC 0.78,p < 0.01). Post-processing caused significant improvement, with overall IQ improving from 2.63 (CACTOrg) to 1.39 (CACTMC_no_bone;p < 0.01) and a decrease in the mean distance of identifiable, subcapsular vessels to the liver capsule by 4 mm (p < 0.01). This proved especially true for datasets with low parenchymal and high hepatic artery contrast. A good interobserver agreement (ICC = 0.73) was recorded concerning the presence of motion artifacts, with significantly less discernible motion after post-processing (CACTOrg:1.31 ± 1.67, CACTMC_no_bone:1.00 ± 1.34, p < 0.01). Of the 27 datasets, ≥ 23 CACTMC_no_bone were preferred, with identical datasets chosen by the readers to show benefit from the algorithm. CONCLUSION: Application of a 3D-motion correction algorithm significantly improved IQ in diagnostically limited CACTs during TACE, with the potential to decrease repeat acquisitions.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Algoritmos , Artefatos , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia
5.
Eur Radiol Exp ; 6(1): 24, 2022 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-35578057

RESUMO

BACKGROUND: The aim of this animal study was to compare the fluoroscopic image quality (IQ) and radiation dose between a tantalum (Ta)-specific contrast-to-noise ratio-driven exposure control (Ta-CEC) and a detector dose-driven exposure control (DEC) in abdominal angiography. METHODS: Nine angiography scenarios were created in seven anaesthetised pigs using Ta-based embolisation material during percutaneous liver and kidney intervention. Fluoroscopic images were acquired using three DEC protocols with different dose levels and Ta-CEC protocols with different IQ levels, sampled in small steps. Polymethyl-methacrylate and aluminium plates were used to simulate attenuation of three water equivalent thicknesses (WET). Three blinded readers evaluated the IQ of DEC and dose equivalent Ta images and selected the Ta-IQ equivalent image corresponding to the DEC image. RESULTS: Interobserver agreement for the IQ assessment was 0.43 for DEC, 0.56 for Ta-CEC and for the assessment of incident air kerma at the interventional reference point (Ka,r) for the Ta-IQ equivalent image 0.73. The average IQ of the dose equivalent Ta images was superior compared to the DEC images (p < 0.001) and also for every WET (26, 31, or 36 cm) and dose level (p ≤ 0.022). The average Ka,r for the Ta-IQ equivalent images was 59 ± 16% (mean ± standard deviation) lower compared to the DEC images (p < 0.001). CONCLUSIONS: Compared to DEC, Ta-CEC significantly improved the fluoroscopic depiction of Ta, while maintaining the Ka,r. Alternatively, the Ka,r can be significantly reduced by using Ta-CEC instead of DEC, while maintaining equivalent IQ.


Assuntos
Angiografia , Tantálio , Angiografia/métodos , Animais , Fluoroscopia , Imagens de Fantasmas , Doses de Radiação , Suínos
6.
J Clin Med ; 10(17)2021 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-34501284

RESUMO

(1) Background: To comparatively analyze the uptake of hepatocellular carcinoma (HCC) on pre-therapeutic imaging modalities, the arterial phase multi-detector computed tomography (MDCT), the parenchymal phase C-arm computed tomography (CACT), the Technetium99m-macroaggregates of human serum albumin single-photon emission computed tomography/computed tomography (SPECT/CT), and the correlation to the post-therapeutic Yttrium90 positron emission tomography/computed tomography (PET/CT) in patients with selective internal radiation therapy (SIRT). (2) Methods: Between September 2013 and December 2016, 104 SIRT procedures were performed at our institution in 74 patients with HCC not suitable for curative surgery or ablation. Twenty-two patients underwent an identical sequence of pre-therapeutic MDCT, CACT, SPECT/CT, and post-therapeutic PET/CT with a standardized diagnostic and therapeutic protocol. In these 22 patients, 25 SIRT procedures were evaluated. The uptake of the HCC was assessed using tumor-background ratio (TBR). Therefore, regions of interest were placed on the tumor and the adjacent liver tissue on MDCT (TBRMDCT), CACT (TBRCACT), SPECT/CT (TBRSPECT/CT), and PET/CT (TBRPET/CT). Comparisons were made with the Friedman test and the Nemenyi post-hoc test. Correlations were analyzed using Spearman's Rho and the Benjamini-Hochberg method. The level of significance was p < 0.05. (3) Results: TBR on MDCT (1.4 ± 0.3) was significantly smaller than on CACT (1.9 ± 0.6) and both were significantly smaller compared to SPECT/CT (4.6 ± 2.0) (pFriedman-Test < 0.001; pTBRMDCT/TBRCACT = 0.012, pTBRMDCT/TBRSPECT/CT < 0.001, pTBRCACT/TBRSPECT/CT < 0.001). There was no significant correlation of TBR on MDCT with PET/CT (rTBRMDCT/TBRPET/CT = 0.116; p = 0.534). In contrast, TBR on CACT correlated to TBR on SPECT/CT (rTBRCACT/TBRSPECT/CT = 0.489; p = 0.004) and tended to correlate to TBR on PET/CT (rTBRCACT/TBRPET/CT =0.365; p = 0.043). TBR on SPECT/CT correlated to TBR on PET/CT (rTBRSPECT/CT/TBRPET/CT = 0.706; p < 0.001) (4) Conclusion: The uptake assessment on CACT was in agreement with SPECT/CT and might be consistent with PET/CT. In contrast, MDCT was not comparable to CACT and SPECT/CT, and had no correlation with PET/CT due to the different application techniques. This emphasizes the value of the CACT, which has the potential to improve the dosimetric assessment of the tumor and liver uptake for SIRT.

7.
Phys Med Biol ; 66(6): 065020, 2021 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-33709957

RESUMO

Conventional detector-dose driven exposure controls (DEC) do not consider the contrasting material of interest in angiography. Considering the latter when choosing the acquisition parameters should allow for optimization of x-ray quality and consecutively lead to a substantial reduction of radiation exposure. Therefore, the impact of a material-specific, contrast-to-noise ratio (CNR) driven exposure control (CEC) compared to DEC on radiation exposure was investigated. A 3D-printed phantom containing iron, tantalum, and platinum foils and cavities, filled with iodine, barium, and gas (carbon dioxide), was developed to measure the CNR. This phantom was placed within a stack of polymethylmethacrylate and aluminum plates simulating a patient equivalent thickness (PET) of 2.5-40 cm. Fluoroscopy and digital radiography (DR) were conducted applying either CEC or three, regular DEC protocols with parameter settings used in abdominal interventions. CEC protocols where chosen to achieve material-specific CNR values similar to those of DEC. Incident air kerma at the reference point(Ka,r), using either CEC or DEC, was assessed and possible Ka,r reduction for similar CNR was estimated. We show that CEC provided similar CNR as DEC at the same or lower Ka,r. When imaging barium, iron, and iodine Ka,r was substantially reduced below a PET of 20 cm and between 25 cm and 30 cm for fluoroscopy and Dr When imaging platinum and tantalum using fluoroscopy and DR and gas using DR, the Ka,r reduction was substantially higher. We estimate the Ka,r reduction for these materials between 15% and 84% for fluoroscopy and DR between 15% and 93% depending on the PET. The results of this study demonstrate a high potential for skin dose reduction in abdominal radiology when using a material-specific CEC compared to DEC. This effect is substantial in imaging materials with higher energy K-edges, which is beneficial, for example, in long-lasting embolization procedures with tantalum-based embolization material in young patients with arterio-venous malformations.


Assuntos
Angiografia/métodos , Meios de Contraste , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Bário , Fluoroscopia/métodos , Humanos , Imageamento Tridimensional/métodos , Iodo , Ferro , Tomografia por Emissão de Pósitrons , Doses de Radiação , Exposição à Radiação , Radiografia , Pele/efeitos da radiação , Raios X
8.
Rofo ; 193(8): 928-936, 2021 Aug.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-33535258

RESUMO

PURPOSE: Chemosaturation percutaneous hepatic perfusion (CS-PHP) allows selective intrahepatic delivery of high dose cytotoxic melphalan in patients with curatively untreatable liver tumors while limiting systemic toxicity through hemofiltration of the hepatic venous blood. Aim of this study was to investigate the response to therapy, survival and safety of the CS-PHP procedure in patients with liver-dominant metastatic uveal melanoma (UM). MATERIALS AND METHODS: Overall response rate (ORR) and disease control rate (DCR) were assessed according to Response Evaluation Criteria In Solid Tumors (RECIST1.1). Median overall survival (mOS), median progression-free survival (mPFS) and hepatic progression-free survival (mhPFS) were analyzed using Kaplan-Meier estimation. Adverse events were evaluated with Common Terminology Criteria for Adverse Events (CTCAE) v5. RESULTS: Overall, 30 patients were treated with 70 CS-PHP in a salvage setting from October 2014 to January 2019. In total, ORR and DCR were 42.3 % and 80.8 %, respectively. Overall, mOS was 12 (95 % confidence interval (CI) 7-15) months, and both, mPFS and mhPFS were 6 months, respectively (95 % CI 4-10; 95 % CI 4-13). Adverse events (AE) most frequently included significant but transient hematologic toxicities (87 % of grade 3/4 thrombocytopenia), less frequent AEs were hepatic injury extending to liver failure (3 %), cardiovascular events including one case of ischemic stroke (3 %). CONCLUSION: Salvage treatment with CS-PHP is effective in selected patients with UM. The interventional procedure is safe. Serious hepatic and cardiovascular events, although rare, require careful patient selection and should be closely monitored. KEY POINTS: · CS-PHP is safe for selected patients with liver-dominant metastatic uveal melanoma.. · CS-PHP resulted in hepatic disease control in 80 % of patients.. · Hematologic events following CS-PHP are common but manageable.. CITATION FORMAT: · Dewald CL, Hinrichs JB, Becker LS et al. Chemosaturation with Percutaneous Hepatic Perfusion: Outcome and Safety in Patients with Metastasized Uveal Melanoma. Fortschr Röntgenstr 2021; 193: 928 - 936.


Assuntos
Neoplasias Hepáticas , Neoplasias Uveais , Antineoplásicos Alquilantes/uso terapêutico , Quimioterapia do Câncer por Perfusão Regional , Humanos , Neoplasias Hepáticas/tratamento farmacológico , Melanoma , Perfusão , Neoplasias Uveais/tratamento farmacológico
9.
Cardiovasc Intervent Radiol ; 44(4): 610-618, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33280058

RESUMO

PURPOSE: The aim of this retrospective study was to evaluate the feasibility of a motion correction 3D reconstruction prototype technique for C-arm computed tomography (CACT). MATERIAL AND METHODS: We included 65 consecutive CACTs acquired during transarterial chemoembolization of 54 patients (47 m,7f; 67 ± 11.3 years). All original raw datasets (CACTOrg) underwent reconstruction with and without volume punching of high-contrast objects using a 3D image reconstruction software to compensate for motion (CACTMC_bone;CACTMC_no bone). Subsequently, the effect on image quality (IQ) was evaluated using objective (image sharpness metric) and subjective criteria. Subjective criteria were defined by vessel geometry, overall IQ, delineation of tumor feeders, the presence of foreign material-induced artifacts and need for additional imaging, assessed by two independent readers on a 3-(vessel geometry and overall IQ) or 2-point scale, respectively. Friedman rank-sum test and post hoc analysis in form of pairwise Wilcoxon signed-rank test were computed and inter-observer agreement analyzed using kappa test. RESULTS: Objective IQ as defined by an image sharpness metric, increased from 273.5 ± 28 (CACTOrg) to 328.5 ± 55.1 (CACTMC_bone) and 331 ± 57.8 (CACTMC_no bone; all p < 0.0001). These results could largely be confirmed by the subjective analysis, which demonstrated predominantly good and moderate inter-observer agreement, with best agreement for CACTMC_no bone in all categories (e.g., vessel geometry: CACTOrg: κ = 0.51, CACTMC_bone: κ = 0.42, CACTMC_no bone: κ = 0.69). CONCLUSION: The application of a motion correction algorithm was feasible for all data sets and led to an increase in both objective and subjective IQ parameters. LEVEL OF EVIDENCE: 3.


Assuntos
Algoritmos , Artefatos , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Imageamento Tridimensional/métodos , Neoplasias Hepáticas/terapia , Tomografia Computadorizada por Raios X/métodos , Idoso , Carcinoma Hepatocelular/diagnóstico , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico , Masculino , Estudos Retrospectivos
10.
Abdom Radiol (NY) ; 45(11): 3934-3943, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32451673

RESUMO

BACKGROUND: To assess the technical feasibility, success rate, puncture complications and procedural characteristics of transjugular intrahepatic portosystemic shunt (TIPS) placement using a three-dimensional vascular map (3D-VM) overlay based on image registration of pre-procedural contrast-enhanced (CE) multi-detector computed tomography (MDCT) for portal vein puncture guidance. MATERIALS AND METHODS: Overall, 27 consecutive patients (59 ± 9 years, 18male) with portal hypertension undergoing elective TIPS procedure were included. TIPS was guided by CE-MDCT overlay after image registration based on fluoroscopic images. A 3D-VM of the hepatic veins and the portal vein was created based on the pre-procedural CE-MDCT and superimposed on fluoroscopy in real-time. Procedural characteristics as well as hepatic vein catheterization time (HVCT), puncture time (PT), overall procedural time (OPT), fluoroscopy time (FT) and the dose area product (DAP) were evaluated. Thereafter, HVCT, PT, OPT and FT using 3D-VM (61 ± 9 years, 14male) were compared to a previous using classical fluoroscopic guidance (53 ± 9 years, 21male) for two interventional radiologist with less than 3 years of experience in TIPS placement. RESULTS: All TIPS procedure using of 3D/2D image registered 3D-VM were successful with a significant reduction of the PSG (p < 0.0001). No clinical significant complication occurred. HVCT was 14 ± 11 min, PT was 14 ± 6 min, OPT was 64 ± 29 min, FT was 21 ± 12 min and DAP was 107.48 ± 93.84 Gy cm2. HVCT, OPT and FT of the interventionalist with less TIPS experience using 3D/2D image registered 3D-VM were statistically different to an interventionalist with similar experience using fluoroscopic guidance (pHVCT = 0.0022; pOPT = 0.0097; pFT = 0.0009). PT between these interventionalists was not significantly different (pPT = 0.2905). CONCLUSION: TIPS placement applying registration-based CE-MDCT vessel information for puncture guidance is feasible and safe. It has the potential to improve hepatic vein catherization, portal vein puncture and radiation exposure.


Assuntos
Hipertensão Portal , Derivação Portossistêmica Transjugular Intra-Hepática , Fluoroscopia , Humanos , Hipertensão Portal/diagnóstico por imagem , Hipertensão Portal/cirurgia , Veia Porta/diagnóstico por imagem , Veia Porta/cirurgia , Punções , Resultado do Tratamento
11.
PLoS One ; 15(2): e0228501, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32012198

RESUMO

BACKGROUND: External validation of prognostic risk models is essential before they are implemented in clinical practice. This study evaluated the recently developed MEGNA score for survival prediction after resection of intrahepatic cholangiocarcinoma (ICC), with a focus on the direct comparison of its prognostic value to that of the current International Union Against Cancer (UICC)/American Joint Committee on Cancer (AJCC) Cancer staging system. MATERIAL AND METHODS: Between 1997 and 2018, 417 consecutive patients with ICC were referred to our tertiary care centre and were retrospectively identified out of a dedicated clinical database. Of this group, 203 patients underwent surgical resection and met the inclusion criteria. Multivariate analysis was performed to assess the predictors of the recently proposed MEGNA score regarding overall survival (OS). Concordance indices (C-indices) and integrated Brier scores (IBS) were calculated to assess the ability of both the MEGNA score and the current (8th) edition of the UICC/AJCC Cancer staging system to predict individual patient outcome. RESULTS: Stratification according to the MEGNA score resulted in a median OS of 34.5 months, 26.1 months, 21.5 months, and 16.6 months for MEGNA scores 0, 1, 2, and ≥3, respectively (log rank p < 0.001). However, of the five factors that contribute to the MEGNA score, age > 60 years was not a predictor for poor OS in our cohort. The C-index for the MEGNA score was 0.58, the IBS was 0.193. The 8th edition of the UICC/AJCC system performed slightly better, with a C-index of 0.61 and an IBS of 0.186. CONCLUSION: The ability of the MEGNA score to predict individual patient outcome was only moderate in this external validation. Its prognostic value did not reach that of the more widely known and used UICC/AJCC system. However, neither scoring system performed well enough to support clear-cut clinical decisions.


Assuntos
Neoplasias dos Ductos Biliares/diagnóstico , Colangiocarcinoma/diagnóstico , Oncologia/métodos , Estadiamento de Neoplasias/métodos , Idoso , Neoplasias dos Ductos Biliares/mortalidade , Neoplasias dos Ductos Biliares/patologia , Ductos Biliares Intra-Hepáticos/patologia , Colangiocarcinoma/mortalidade , Colangiocarcinoma/patologia , Estudos de Coortes , Feminino , Humanos , Agências Internacionais/normas , Masculino , Oncologia/normas , Pessoa de Meia-Idade , Estadiamento de Neoplasias/normas , Valor Preditivo dos Testes , Prognóstico , Projetos de Pesquisa/normas , Estudos Retrospectivos , Fatores de Risco , Análise de Sobrevida , Estados Unidos
12.
Abdom Radiol (NY) ; 45(10): 3326-3336, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-31781900

RESUMO

PURPOSE: To compare two different types of drug-eluting microspheres with regard to impact on HRQoL after first TACE, tumour response, peri-procedural complications, adverse events and 1-year survival in patients suffering from unresectable hepatocellular carcinoma (HCC). METHODS: HRQoL was prospectively assessed with validated questionnaires (EORTC QLQ-C30 and -HCC18) before and 2 weeks after treatment with their first drug-eluting beads (DEB-)TACE with either acrylamido-polyvinylalcohol-AMPS hydrogel microspheres (groupDCB; 20 patients) or polyvinyl alcohol-co-acrylic acid microspheres (groupHS; 16 patients). Baseline characteristics, peri-procedural complications, treatment-related adverse events and 1-year survival were compared between both types of microspheres. Treatment response and objective response rates (ORR) were analysed using established tumour response criteria. Subgroup analysis for pooled groups with small (groupSMALL; 21 patients) versus large particles (groupLARGE; 15 patients) was performed. RESULTS: At baseline, there were no significant differences between the treated microsphere groups. No significant differences were found in absolute HRQoL changes after first DEB-TACE between the different types of microspheres. Response rates and survival were comparable between the investigated microsphere groups. For groupSMALL, we found a significant difference in post-interventional deterioration of physical function (- 19.4%) compared to groupLARGE (- 8%; p = 0.025). Tumour response and ORR according to mRECIST were significantly higher in groupSMALL (p = 0.008; p = 0.009). CONCLUSION: DEB-TACE is generally well tolerated and effective, with comparable changes in HRQoL for both types of drug-eluting microspheres. Tumour response is better with small microspheres. A relevant deterioration of physical function underlines that an aggressive TACE using small beads should be well deliberated.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Preparações Farmacêuticas , Antibióticos Antineoplásicos/uso terapêutico , Carcinoma Hepatocelular/tratamento farmacológico , Doxorrubicina , Humanos , Neoplasias Hepáticas/tratamento farmacológico , Qualidade de Vida , Resultado do Tratamento
13.
J Intensive Care Med ; 35(2): 128-139, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31645176

RESUMO

BACKGROUND: Intensive care patients with nonocclusive mesenteric ischemia (NOMI) show mortality rates of 70% to 90%. Besides emergency surgery, different interventional local vasodilatory treatment (LVT) attempts have been described. We performed a systematic review and a meta-analysis to evaluate feasibility, efficacy, and tolerability of LVT in patients with life-threatening NOMI. METHODS: Searches of PubMed, EMBASE, Web of Science, and Cochrane Library databases were performed until February 2019. Measured outcomes included immediate technical success rates (as indicated by mesenteric vasodilation on angiography or clinical improvement) and adverse events (AEs). Therapeutic efficacy was measured by the assessment of overall mortality. RESULTS: Twelve studies (335 patients, 245 received LVT) from 1977 to 2018 were included. All studies were retrospective (4 comparative and 8 noncomparative). Different intra-arterial vasodilators (4× papaverine, 6× prostaglandin E1, 1× tolazoline/heparin, 1× tolazoline + iloprost) were reported. Initial technical success rate was 75.9% (95% confidence interval [CI], 55.1%-89%, P = .017) with an AE rate of 2.9% (95% CI: 1.3%-6.6%; P = .983). Overall mortality in LVT patients was 40.3% (95% CI: 28.7%-53%, P = .134). In 4 studies, outcomes were compared between patients receiving LVT to those who received standard of care (odds ratio for death in LVT patients was 0.261 [95% CI: 0.095-0.712, P = .009]). CONCLUSIONS: Local vasodilatory treatment appears to be safe in patients with NOMI and might have the potential to at least partially reverse mesenteric vasoconstriction features in control angiographies. However, with no randomized and prospective studies available yet, the overall quality of published studies has to be considered as low; therefore, it is not possible to draw generalizable conclusions from the present data concerning clinical end points. Its application might hold promise as a rescue treatment strategy and deserves further evaluation in randomized controlled trials.


Assuntos
Cuidados Críticos/métodos , Isquemia Mesentérica/tratamento farmacológico , Isquemia Mesentérica/mortalidade , Vasodilatadores/uso terapêutico , Humanos , Unidades de Terapia Intensiva , Razão de Chances , Estudos Retrospectivos , Padrão de Cuidado , Resultado do Tratamento , Vasodilatação
14.
Cardiovasc Intervent Radiol ; 42(10): 1441-1448, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31089781

RESUMO

PURPOSE: To evaluate the feasibility of 2D-perfusion angiography (2D-PA) for detecting leakage of the double-balloon catheter used for chemosaturation percutaneous hepatic perfusion (CS-PHP). MATERIALS AND METHODS: Overall, 112 CS-PHP (09/2015-09/2018) in 52 patients were retrospectively screened for leakage alongside the double-balloon catheter on standard venograms. Finally, 18 procedures with visually detected leakage were included. Fifteen consecutive procedures without leakage served as control. To evaluate 2D-PA for leakage detection, the acquired digital subtraction venograms were post-processed. For each balloon, two different target ROIs were evaluated to assess a possible impact of localization and shape of the ROIs. Time to peak (TTP), peak density (PD), area under the curve (AUC), and ratios of target ROI/reference ROIs (PDtROI/PDREF; AUCtROI/AUCREF; and TTPtROI/TTPREF) were calculated. RESULTS: Leakages were located as follows: 15/18 cranial and 3/18 caudal. At the cranial balloon both ROIs showed a significant decrease in PDtROI/PDREF and AUCtROI/AUCREF (ROI1: p < 0.0001; p < 0.0001; ROI2: p < 0.0001; p < 0.0001) and a significant increase in TTPtROI/TTPREF (ROI1: p = 0.0009; ROI2: p = 0.0003) after double-balloon correction. Following balloon adjustment, the 2D-PA ratios (PD and AUC) of the tested ROIs differed significantly (p < 0.05). The inter-individual comparison of the 2D-PA parameters of the group with leakage before balloon correction and the non-leakage group showed significantly different 2D-PA values for the cranial balloon in both ROIs (p < 0.05). No significant differences were found for the caudal balloon. CONCLUSION: 2D-PA provides a feasible tool for detecting leakages alongside the cranial portion of the double-balloon catheter used in CS-PHP. The shape and position of the ROIs used to assess perfusion and flow have an impact on the measurements.


Assuntos
Angiografia Digital/métodos , Antineoplásicos Alquilantes/uso terapêutico , Cateterismo/instrumentação , Quimioterapia do Câncer por Perfusão Regional/métodos , Neoplasias Hepáticas/tratamento farmacológico , Melfalan/uso terapêutico , Antineoplásicos Alquilantes/administração & dosagem , Cateterismo/métodos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Melfalan/administração & dosagem , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
15.
Abdom Radiol (NY) ; 43(5): 1245-1253, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28840307

RESUMO

PURPOSE: To analyze the feasibility of 2D-perfusion angiography (2D-PA) for the quantification of perfusion reduction following transarterial chemoembolization with drug-eluting beads (DEB-TACE). METHODS: Overall, 24 DEB-TACE procedures in 19 patients were included. To quantify changes in tumor perfusion following DEB-TACE using 2D-PA, the acquired digital subtraction angiography (DSA) series were post-processed. A reference region-of-interest (ROI) in a main hepatic artery and two, distal target ROIs in embolized tumor tissue and in non-target liver parenchyma were placed in corresponding areas on DSA pre- and post-DEB-TACE. The time to peak (TTP), peak density (PD), and the area under the curve (AUC) were assessed and the ratios reference ROI/target ROIs were calculated. RESULTS: In the embolized tumor, the 2D-PA ratios changed significantly (p < 0.05) after DEB-TACE, whereas no significant change was observed for non-target liver parenchyma (p > 0.05). PDtumor/PDinflow differed significantly to PDparenchyma/PDinflow pre-DEB-TACE (p < 0.0001), likewise AUCtumor/AUCinflow to AUCparenchyma/AUCinflow (p < 0.0001) with higher values in tumor tissue. The post-DEB-TACE ratios of AUC decreased significantly in the tumor tissue compared to the non-target liver parenchyma (p < 0.05). CONCLUSION: 2D-PA offers an objective approach to quantify the immediate perfusion reduction of embolized tumor tissue following DEB-TACE and may therefore be used to monitor peri-interventional stasis and to quantify technical success.


Assuntos
Angiografia Digital/métodos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Vias de Administração de Medicamentos , Estudos de Viabilidade , Feminino , Artéria Hepática/diagnóstico por imagem , Humanos , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA