Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Reg Anesth Pain Med ; 2024 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-39004441

RESUMO

BACKGROUND: Intraoperative pain during cesarean delivery with or without conversion to general anesthesia has been shown to negatively impact maternal and perinatal morbidity. Efforts to reduce these adverse events are a recent focus of obstetric anesthesia care. We aimed to assess rates of and risk factors for conversion to general anesthesia and intraoperative pain during intrapartum cesarean delivery with an indwelling epidural catheter in our academic center. METHODS: In this retrospective cohort study, all women undergoing cesarean delivery with an indwelling epidural catheter between January 2017 and June 2022 were included. Labor epidural analgesia was provided according to a standardized protocol, and conversion to epidural anesthesia was achieved in the operating room before surgery. We determined the conversion rate to general anesthesia and associated risk factors. Second, we examined the rate of administration of analgesics/sedatives and related risk factors in cesarean cases that were not converted to general anesthesia. RESULTS: Among the 1192 women undergoing intrapartum cesarean delivery with epidural anesthesia, there were 97 cases with conversion to general anesthesia (8.1%), of which 87 (89.7%) were due to a failed epidural. Higher age, higher weight, and higher gestational age were associated with decreased odds of conversion to general anesthesia. Higher gravidity and longer surgical time were associated with increased odds. An emergent indication was not associated with conversion to general anesthesia. Intravenous analgesic/sedative supplementation occurred in 141 cases (12.9%). Higher age was associated with decreased odds of supplementation, and longer surgical time was associated with increased odds. CONCLUSION: In our tertiary academic center, the rate of intraoperative conversion to general anesthesia and administration of analgesic/sedative medication among women undergoing intrapartum cesarean delivery with epidural anesthesia was relatively high. Emergency cesarean delivery was not associated with either of the above endpoints.

2.
Isr Med Assoc J ; 26(1): 24-29, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38420638

RESUMO

BACKGROUND: Pulmonary aspiration is a potentially lethal perioperative complication that can be precipitated by gastric insufflation. Face mask ventilation (FMV), a ubiquitous anesthetic procedure, can cause gastric insufflation. FMV with an inspiratory pressure of 15 cm H2O provides the best balance between adequate pulmonary ventilation and a low probability of gastric insufflation. There is no data about the effects of FMV > 120 seconds. OBJECTIVES: To investigate the effect of prolonged FMV on gastric insufflation. METHODS: We conducted a prospective observational study at a tertiary medical center with female patients who underwent oocyte retrieval surgery under general anesthesia FMV. Pre- and postoperative gastric ultrasound examinations measured the gastric antral cross-sectional area to detect gastric insufflation. Pressure-controlled FMV with an inspiratory pressure of 15 cm H2O was continued from the anesthesia induction until the end of the surgery. RESULTS: The study comprised 49 patients. Baseline preoperative gastric ultrasound demonstrated optimal and good image quality. All supine measurements were feasible. The median duration of FMV was 13 minutes (interquartile range 9-18). In the postoperative period, gastric insufflation was detected in only 2 of 49 patients (4.1%). There was no association between the duration of FMV and delta gastric antral cross-sectional area (ß -0.01; 95% confidence interval -0.04 to 0.01, P = 0.31). CONCLUSIONS: Pressure-controlled FMV with an inspiratory pressure of 15 cm H2O carries a low incidence of gastric insufflations, not only as a bridge to a definitive airway but as an alternative ventilation method for relatively short procedures in selective populations.


Assuntos
Insuflação , Máscaras Laríngeas , Feminino , Humanos , Anestesia Geral/efeitos adversos , Anestesia Geral/métodos , Insuflação/efeitos adversos , Máscaras Laríngeas/efeitos adversos , Respiração Artificial/efeitos adversos , Respiração Artificial/métodos , Estômago/diagnóstico por imagem , Estudos Prospectivos
3.
Acta Anaesthesiol Scand ; 67(1): 29-35, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36056463

RESUMO

BACKGROUND: Conversion from spinal anaesthesia to general anaesthesia (GA) was shown to be associated with more complications. It has been postulated that spinal injection of a low dose of local anaesthetic is a risk factor. We aimed to discover the rate of conversion from spinal anaesthesia to GA in women who received at least 10 mg heavy bupivacaine and opioids and assess its risk factors. METHODS: All women that underwent spinal anaesthesia for caesarean section from 1 January 2017 to 31 December 2020 were included in this analysis. Spinal anaesthesia was performed according to department protocol using heavy bupivacaine 0.5% 10-13 mg, fentanyl 20 µg, and morphine 0.1 mg. We examined rate of conversion from spinal anaesthesia to GA and rate of need for analgesia/sedation. RESULTS: There were 1.7% of women that required conversion to GA. Bupivacaine dose (OR 0.54 [95% CI 0.38 to 0.75], p < 0.001), surgery time (OR 1.03 [95% CI 1.02 to 1.04], p < 0.001), emergency caesarean section (OR 1.06 [95% CI 1.16 to 3.76], p = 0.015), and postpartum haemorrhage (OR 5.96 [95% CI 1.09 to 25.18], p = 0.025) were independent predictors of need for conversion to GA. Of the women who had CS under spinal anaesthesia, 4.1% of parturients required intraoperative analgesics/sedatives and 9.1% required anxiolysis. CONCLUSIONS: A small proportion of women required conversion to GA. This conversion occurred especially with emergency caesarean section and when low spinal bupivacaine doses were used.


Assuntos
Anestesia Obstétrica , Raquianestesia , Feminino , Gravidez , Humanos , Raquianestesia/efeitos adversos , Cesárea , Incidência , Anestesia Obstétrica/efeitos adversos , Anestésicos Locais , Bupivacaína , Anestesia Geral , Suplementos Nutricionais
4.
Acta Anaesthesiol Scand ; 66(5): 563-568, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35184286

RESUMO

BACKGROUND: Epidural blood patch is a common effective treatment for postdural puncture headache after accidental dural puncture during labor and may be done in conventional or fluoroscopy-guided methods. The aim of this study was to compare intensity of headache at the time of discharge from the hospital and to compare blood volumes injected in conventional epidural blood patches versus fluoroscopic-guided blood patches and evaluate the side effects of both method of treatment. METHODS: Between the years 2010 and 2020, 84 patients who were diagnosed with postdural puncture headache received either a conventional epidural blood patch or a fluoroscopic-guided blood patch. Blood volumes were compared and evaluation of side effects was made based on data collected during and after the procedure. RESULTS: Eighty-four patients were included in this study. Fifty-two women in the conventional epidural blood patch group and 32 in the fluoroscopic-guided blood patch group. Women in the conventional epidural blood patch group received statistically significantly higher doses of blood than women in the fluoroscopic-guided blood patch group: conventional method 29 ml IQR [23-36] versus fluoroscopic method 16 ml, IQR [12-18], p < .001 with no difference in headache pain intensity at hospital release. There was no difference between groups in hospital length of stay, or persistent PDPH. There was also no difference chronic headache or backache between the two groups. CONCLUSIONS: Women who received fluoroscopic epidural blood patch required a much lower volume of blood injected while there was no difference between groups in headache pain intensity at discharge.


Assuntos
Obstetrícia , Cefaleia Pós-Punção Dural , Placa de Sangue Epidural/métodos , Feminino , Cefaleia , Humanos , Cefaleia Pós-Punção Dural/terapia , Gravidez , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA