Eur J Radiol ; 156: 110548, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36209537

RESUMO

PURPOSE: To evaluate fetal doses from extremity CBCT examinations at different stages of pregnancy and to investigate different methods of fetal dose optimization. METHOD: Fetal doses were measured in an anthropomorphic phantom for two CBCT examination protocols - knee and elbow. The measurements were made at three different heights representing the three trimesters during pregnancy and three different depths in the phantom. The effect of soft tissue layer, tube voltage, add-on device shield and body angulation on fetal dose were investigated. RESULTS: The fetal doses in clinical examination protocols were in the range of 3.4 to 6.0 µGy during knee examinations and 2.9 to 7.7 µGy during elbow examinations depending on the depth of the fetus and the stage of pregnancy. A soft tissue layer representing variative body composition above abdomen region decreased the fetal dose up to 19 % in knee and up to 21 % in elbow examinations. Using lower tube voltage decreased the fetal doses up to 45 % (knee) and 51 % (elbow). An add-on device shield decreased the fetal doses up to 91 % (knee) and up to 75 % (elbow). Turning the body away from the device bore reduced the fetal doses up to 62 %. The conversion factor to convert an entrance surface dose to the fetal dose ranged from 0.4 to 0.6. CONCLUSIONS: The fetal doses from CBCT examinations of extremities are low and do not produce a concern about radiation detriment to the fetus. The most efficient way found to reduce the fetal dose was to use the add-on device shielding.

2.
Front Physiol ; 13: 934941, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35874533

RESUMO

Objectives: In thoracic aortic aneurysm (TAA) of the ascending aorta (AA), AA is progressively dilating due to the weakening of the aortic wall. Predicting and preventing aortic dissections and ruptures in TAA continues to be challenging, and more accurate assessment of the AA dilatation, identification of high-risk patients, and timing of repair surgery are required. We investigated whether wall shear stress (WSS) predicts pathological and biomechanical changes in the aortic wall in TAA. Methods: The study included 12 patients with bicuspid (BAV) and 20 patients with the tricuspid aortic valve (TAV). 4D flow magnetic resonance imaging (MRI) was performed a day before aortic replacement surgery. Biomechanical and histological parameters, including assessing of wall strength, media degeneration, elastin, and cell content were analyzed from the resected AA samples. Results: WSSs were greater in the outer curves of the AA compared to the inner curves in all TAA patients. WSSs correlated with media degeneration of the aortic wall (ρ = -0.48, p < 0.01), elastin content (ρ = 0.47, p < 0.01), and aortic wall strength (ρ = -0.49, p = 0.029). Subsequently, the media of the outer curves was thinner, more rigid, and tolerated lower failure strains. Failure values were shown to correlate with smooth muscle cell (SMC) density (ρ = -0.45, p < 0.02), and indicated the more MYH10+ SMCs the lower the strength of the aortic wall structure. More macrophages were detected in patients with severe media degeneration and the areas with lower WSSs. Conclusion: The findings indicate that MRI-derived WSS predicts pathological and biomechanical changes in the aortic wall in patients with TAA and could be used for identification of high-risk patients.

3.
Biomed Phys Eng Express ; 8(3)2022 04 22.
Artigo em Inglês | MEDLINE | ID: mdl-35354122

RESUMO

MOSFET dosimeters have widely been used to measure radiation doses caused by x-rays. When using the MOSFET dosimeters, calibration factors (CFs) have a direct effect on reliability of dose measurements. The aim of this paper was to study the effect of various calibration methods on the CFs of the MOSFET dosimeters. The CFs were measured on clinical digital x-ray angiography (XA) and computed tomography (CT) devices using a calibrated CT ionization chamber and a standard polymethyl methacrylate (PMMA) phantom. The measurements were conducted by having the dosimeters (1) in air, (2) on the surface of the PMMA phantom and (3) inside the phantom. A statistically significant difference was seen between the CFs measured on the XA and CT devices. The CFs measured on the CT device were 20%-165% higher than those measured with the XA device (p < 0.001) in every calibration geometry. Furthermore, the calibration geometry had a notable effect on the CFs on CT. The CFs on the surface of the phantom were 18%-25% higher than in air (p < 0.05), and the CFs inside the phantom were 32%-39% smaller than in air (p < 0.05). These results suggest that the calibration of the MOSFET dosimeters should be conducted with the same device that is used in actual dose measurements. Also, the scattering conditions and the calibration geometry should be similar in the calibration and subsequent dose measurements.


Assuntos
Radiologia , Calibragem , Humanos , Polimetil Metacrilato , Doses de Radiação , Dosímetros de Radiação , Radiometria/métodos , Reprodutibilidade dos Testes
4.
Eur Arch Otorhinolaryngol ; 279(9): 4407-4414, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35084532

RESUMO

PURPOSE: To compare the image quality produced by equivalent low-dose and default sinus imaging protocols of a conventional dental cone-beam computed tomography (CBCT) scanner, an extremity CBCT scanner and a clinical multidetector computed tomography (MDCT) scanner. METHODS: Three different phantoms were scanned using dose-neutral ultra-low-dose and low-dose sinus imaging protocols, as well as default sinus protocols of each device. Quantified parameters of image quality included modulation transfer function (MTF) to characterize the spatial response of the imaging system, contrast-to-noise ratio, low contrast visibility, image uniformity and Hounsfield unit accuracy. MTF was calculated using the line spread and edge spread functions (LSF and ESF). RESULTS: The dental CBCT had superior performance over the extremity CBCT in each studied parameter at similar dose levels. The MDCT had better contrast-to-noise ratio, low contrast visibility and image uniformity than the CBCT scanners. However, the CBCT scanners had better resolution compared to the MDCT. Accuracy of HU values for different materials was on the same level between the dental CBCT and MDCT, but substantially poorer performance was observed with the extremity CBCT. CONCLUSIONS: The studied dental CBCT scanner showed superior performance over the studied extremity CBCT scanner when using dose-neutral imaging protocols. In case a dental CBCT is not available, the given extremity CBCT is still a viable option as it provides the benefit of high resolution over a conventional MDCT.


Assuntos
Tomografia Computadorizada de Feixe Cônico Espiral , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Tomografia Computadorizada Multidetectores/métodos , Imagens de Fantasmas , Doses de Radiação
5.
Radiat Prot Dosimetry ; 188(2): 181-190, 2020 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-31838516

RESUMO

In contemporary interventional cardiology, for typical elderly patients, the most severe radiation-related harm to patients can be considered to come from skin exposures. In this paper, maximum local skin doses in cardiological procedures are explored with Gafchromic film dosimetry. Film and reader calibrations and reading were performed at the Secondary Standards Dosimetry Laboratory of the Radiation and Nuclear Safety Authority (STUK), and data were gathered from seven hospitals in Finland. As alert levels for early transient erythema, 200 Gycm2 kerma area product (KAP) and 2000 mGy air kerma levels for transcatheter aortic valve implantations (TAVI) procedures are proposed. The largest doses were measured in TAVI (4158.8 mGy) and percutaneous coronary interventions (PCI) (941.68 mGy). Accuracies of the GE DoseWatch and Siemens CareMonitor skin dose estimates were reasonable, but more results are needed to reliably assess and validate the tools' capabilities and reliabilities. Uncertainty of the Gafchromic dosimetry was estimated as 9.1% for a calibration with seven data points and 19.3% for a calibration with five data points.


Assuntos
Cardiologia , Intervenção Coronária Percutânea , Idoso , Finlândia , Fluoroscopia , Humanos , Doses de Radiação , Radiografia Intervencionista , Pele
6.
Radiat Prot Dosimetry ; 185(4): 483-493, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-30989216

RESUMO

The amount of interventional procedures such as percutaneous coronary intervention (PCI), transcatheter aortic valve implantation (TAVI), pacemaker implantation (PI) and ablations has increased within the previous decade. Simultaneously, novel fluoroscopy mainframes enable lower radiation doses for patients and operators. Therefore, there is a need to update the existing diagnostic reference levels (DRLs) and propose new ones for common or recently introduced procedures. We sought to assess patient radiation doses in interventional cardiology in a large sample from seven hospitals across Finland between 2014 and 2016. Data were used to set updated national DRLs for coronary angiographies (kerma-air product (KAP) 30 Gycm2) and PCIs (KAP 75 cm2), and novel levels for PIs (KAP 3.5 Gycm2), atrial fibrillation ablation procedures (KAP 25 Gycm2) and TAVI (KAP 90 Gycm2). Tentative KAP values were set for implantations of cardiac resynchronization therapy devices (CRT, KAP 22 Gycm2), electrophysiological treatment of atrioventricular nodal re-entry tachycardia (6 Gycm2) and atrial flutter procedures (KAP 16 Gycm2). The values for TAVI and CRT device implantation are published for the first time on national level. Dose from image acquisition (cine) constitutes the major part of the total dose in coronary and atrial fibrillation ablation procedures. For TAVI, patient weight is a good predictor of patient dose.


Assuntos
Cardiologia/normas , Doses de Radiação , Radiografia Intervencionista/métodos , Radiologia Intervencionista/normas , Radiometria , Idoso , Valva Aórtica/cirurgia , Nó Atrioventricular/patologia , Cardiologia/métodos , Angiografia Coronária , Eletrofisiologia , Feminino , Finlândia , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Radiologia Intervencionista/métodos , Valores de Referência , Taquicardia/patologia
7.
Otol Neurotol ; 39(9): e784-e793, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30199496

RESUMO

HYPOTHESIS: To evaluate the insertion results of a novel straight array (EVO) by detailed imaging and subsequent histology in human temporal bones (TB). BACKGROUND: The main focuses of modern cochlear implant surgery are to prevent damage to the intracochlear structures and to preserve residual hearing. This is often achievable with new atraumatic electrode arrays in combination with meticulous surgical techniques. METHODS: Twenty fresh-frozen TBs were implanted with the EVO. Pre- and postoperative cone beam computed tomography scans were reconstructed and fused for an artifact-free representation of the electrode. The array's vertical position was quantified in relation to the basilar membrane on basis of which trauma was classified (Grades 0-4). The basilar membrane location was modeled from previous histologic data. The TBs underwent subsequent histologic examination. RESULTS: The EVOs were successfully inserted in all TBs. Atraumatic insertion (Grades 0-1) were accomplished in 14 of 20 TBs (70%). There were three apical translocations, and two basal translocations due to electrode bulging. One TB had multiple translocations. The sensitivity and specificity of imaging for detecting insertion trauma (Grades 2-4) was 87.5% and 97.3.0%, respectively. CONCLUSION: Comparable insertion results as reported for other arrays were also found for the EVO. Insertion trauma can be mostly avoided with meticulous insertion techniques to prevent bulging and by limiting the insertion depth angle to 360 degrees. The image fusion technique is a reliable tool for evaluating electrode placement and is feasible for trauma grading.


Assuntos
Implante Coclear/efeitos adversos , Implante Coclear/instrumentação , Implante Coclear/métodos , Osso Temporal/cirurgia , Cadáver , Cóclea/cirurgia , Implantes Cocleares , Tomografia Computadorizada de Feixe Cônico , Técnicas Histológicas , Humanos
8.
PLoS One ; 11(7): e0158673, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27384417

RESUMO

OBJECTIVES: To prospectively compare the diagnostic performance and the visualization of the upper urinary tract (UUT) using a comprehensive 3.0T- magnetic resonance urography (MRU) protocol versus triple-phase computed tomography urography (CTU). METHODS: During the study period (January-2014 through December-2015), all consecutive patients in our tertiary university hospital scheduled by a urologist for CTU to exclude UUT malignancy were invited to participate. Diagnostic performance and visualization scores of 3.0T-MRU were compared to CTU using Wilcoxon matched-pairs test. RESULTS: Twenty patients (39 UUT excreting units) were evaluated. 3.0T-MRU and CTU achieved equal diagnostic performances. The benign etiology of seven UUT obstructions was clarified equally with both methods. Another two urinary tract malignant tumors and one benign extraurinary tumor were detected and confirmed. Diagnostic visualization was slightly better in the intrarenal cavity areas with CTU but worsened towards distal ureter. MRU showed consistently slightly better visualization of the ureter. In the comparison, full 100% visualizations were detected in all areas in 93.6% (with 3.0T-MRU) and 87.2% (with CTU) and >75% visualization in 100% (3.0T-MRU) and 93.6% (CTU). Mean CTU effective radiation dose was 9.2 mSv. CONCLUSIONS: Comprehensive 3.0T-MRU is an accurate imaging modality achieving comparable performance with CTU; since it does not entail exposure to radiation, it has the potential to become the primary investigation technique in selected patients. TRIAL REGISTRATION: ClinicalTrials.gov NCT02606513.


Assuntos
Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Sistema Urinário/diagnóstico por imagem , Urografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Neoplasias Urológicas/diagnóstico , Neoplasias Urológicas/diagnóstico por imagem