Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Semin Cardiothorac Vasc Anesth ; : 10892532241256020, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38842145

RESUMO

BACKGROUND: This survey aimed to explore the availability and accessibility of echocardiography during noncardiac surgery worldwide. METHODS: An internet-based 45-item survey was sent, followed by reminders from August 30, 2021, to August 20, 2022. RESULTS: 1189 responses were received from 62 countries. Nearly seventy-one percent of respondents had intraoperatively used transesophageal or transthoracic echocardiography (TEE and TTE, respectively) for monitoring or examination. The unavailability of echocardiography machines (30.3%), lack of trained personnel (30.2%), and absence of clinical indications (22.6%) were the top 3 reasons for not using intraoperative echocardiography in noncardiac surgery. About 61.5% of participants had access to at least one echocardiography machine. About 41% had access to at least 1 TEE probe, and 62.2% had access to at least 1 TTE probe. Seventy-four percent of centers had a procedure to request intraoperative echocardiography if needed for noncardiac cases. Intraoperative echocardiography service was immediately available in 58% of centers. CONCLUSIONS: Echocardiography machines and skilled echocardiographers are still unavailable at many centers worldwide. National societies should aim to train a critical mass of certified TEE/TTE anesthesiologists and provide all anesthesiologists access to perioperative TEE/TTE machines in anesthesiology departments, considering the increasing number of older and sicker surgical patients scheduled for noncardiac surgery.

3.
Can J Anaesth ; 71(3): 330-342, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38243094

RESUMO

PURPOSE: Biomarkers can aid in perioperative risk stratification. While preoperative copeptin has been associated with adverse events, intraoperative information is lacking and this association may rather reflect a baseline risk. Knowledge about correlations between postoperative copeptin measurements and clinically relevant outcomes is scarce. We examined the association of perioperative copeptin concentrations with postoperative all-cause mortality and/or major adverse cardiac and cerebrovascular events (MACCE) at 12 months and 30 days as well as with perioperative myocardial injury (PMI). METHODS: We conducted a prospective observational cohort study of adults undergoing noncardiac surgery with intermediate to high surgical risk in Basel, Switzerland, and Düsseldorf, Germany from February 2016 to December 2020. We measured copeptin and cardiac troponin before surgery, immediately after surgery (0 hr) and once between the second and fourth postoperative day (POD 2-4). RESULTS: A primary outcome event of a composite of all-cause mortality and/or MACCE at 12 months occurred in 48/502 patients (9.6%). Elevated preoperative copeptin (> 14 pmol·L-1), immediate postoperative copeptin (> 90 pmol·L-1), and copeptin on POD 2-4 (> 14 pmol·L-1) were associated with lower one-year MACCE-free and/or mortality-free survival (hazard ratio [HR], 2.89; 95% confidence interval [CI], 1.62 to 5.2; HR, 2.07; 95% CI, 1.17 to 3.66; and HR, 2.47; 95% CI, 1.36 to 4.46, respectively). Multivariable analysis continued to show an association for preoperative and postoperative copeptin on POD 2-4. Furthermore, elevated copeptin on POD 2-4 showed an association with 30-day MACCE-free survival (HR, 2.15; 95% CI, 1.18 to 3.91). A total of 64 of 489 patients showed PMI (13.1%). Elevated preoperative copeptin was not associated with PMI, while immediate postoperative copeptin was modestly associated with PMI. CONCLUSION: The results of the present prospective observational cohort study suggest that perioperative copeptin concentrations can help identify patients at risk for all-cause mortality and/or MACCE. Other identified risk factors were revised cardiac risk index, body mass index, surgical risk, and preoperative hemoglobin. TRIAL REGISTRATION: ClinicalTrials.gov (NCT02687776); first submitted 9 February 2016.


RéSUMé: OBJECTIF: Les biomarqueurs peuvent aider à la stratification du risque périopératoire. Bien que la copeptine préopératoire ait été associée à des événements indésirables, les informations peropératoires font défaut; plutôt, cette association pourrait refléter un risque de base. Les connaissances sur les corrélations entre les mesures postopératoires de la copeptine et les résultats cliniquement pertinents sont rares. Nous avons examiné l'association entre les concentrations de copeptine périopératoires et la mortalité postopératoire toutes causes confondues et/ou les événements indésirables cardiaques et cérébrovasculaires majeurs (EICCM/MACCE) à 12 mois et 30 jours ainsi qu'en cas de lésion myocardique périopératoire (LMP/PMI). MéTHODE: Nous avons réalisé une étude de cohorte observationnelle prospective d'adultes bénéficiant d'une chirurgie non cardiaque à risque chirurgical intermédiaire à élevé à Bâle, en Suisse, et à Düsseldorf, en Allemagne, de février 2016 à décembre 2020. Nous avons mesuré la copeptine et la troponine cardiaque avant la chirurgie, immédiatement après la chirurgie (0 h) et une fois entre le deuxième et le quatrième jour postopératoire (JPO 2-4). RéSULTATS: Un événement constituant un critère d'évaluation principal d'un composite de mortalité toutes causes confondues et/ou de MACCE à 12 mois est survenu chez 48/502 patient·es (9,6 %). Une élévation de la copeptine préopératoire (> 14 pmol·L−1), de la copeptine postopératoire immédiate (> 90 pmol·L−1) et de la copeptine aux JPO 2 à 4 (> 14 pmol·L−1) était associée à une survie sans MACCE et/ou sans mortalité à un an plus faible (rapport de risque [RR], 2,89; intervalle de confiance [IC] à 95 %, 1,62 à 5,2; RR, 2,07; IC 95 %, 1,17 à 3,66; et RR, 2,47; IC 95 %, 1,36 à 4,46, respectivement). L'analyse multivariée a aussi montré une association entre la copeptine préopératoire et postopératoire aux JPO 2 à 4. De plus, un taux élevé de copeptine aux JPO 2 à 4 a montré une association avec la survie sans MACCE à 30 jours (RR, 2,15; IC 95 %, 1,18 à 3,91). Au total, 64 des 489 patient·es présentaient une LMP (13,1 %). Un taux élevé de copeptine préopératoire n'a pas été associé à la LMP, tandis que la copeptine postopératoire immédiate était modestement associée à la LMP. CONCLUSION: Les résultats de la présente étude de cohorte observationnelle prospective suggèrent que les concentrations périopératoires de copeptine peuvent aider à identifier les personnes à risque de mortalité toutes causes confondues et/ou de MACCE. Les autres facteurs de risque identifiés étaient l'indice de risque cardiaque révisé, l'indice de masse corporelle, le risque chirurgical et l'hémoglobine préopératoire. ENREGISTREMENT DE L'éTUDE: ClinicalTrials.gov (NCT02687776); première soumission le 9 février 2016.


Assuntos
Glicopeptídeos , Complicações Pós-Operatórias , Adulto , Humanos , Estudos Prospectivos , Complicações Pós-Operatórias/epidemiologia , Fatores de Risco , Medição de Risco
4.
JAMA Netw Open ; 6(11): e2342527, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37938844

RESUMO

Importance: Nearly 16 million surgical procedures are conducted in North America yearly, and postoperative cardiovascular events are frequent. Guidelines suggest functional capacity or B-type natriuretic peptides (BNP) to guide perioperative management. Data comparing the performance of these approaches are scarce. Objective: To compare the addition of either N-terminal pro-BNP (NT-proBNP) or self-reported functional capacity to clinical scores to estimate the risk of major adverse cardiac events (MACE). Design, Setting, and Participants: This cohort study included patients undergoing inpatient, elective, noncardiac surgery at 25 tertiary care hospitals in Europe between June 2017 and April 2020. Analysis was conducted in January 2023. Eligible patients were either aged 45 years or older with a Revised Cardiac Risk Index (RCRI) of 2 or higher or a National Surgical Quality Improvement Program, Risk Calculator for Myocardial Infarction and Cardiac (NSQIP MICA) above 1%, or they were aged 65 years or older and underwent intermediate or high-risk procedures. Exposures: Preoperative NT-proBNP and the following self-reported measures of functional capacity were the exposures: (1) questionnaire-estimated metabolic equivalents (METs), (2) ability to climb 1 floor, and (3) level of regular physical activity. Main Outcome and Measures: MACE was defined as a composite end point of in-hospital cardiovascular mortality, cardiac arrest, myocardial infarction, stroke, and congestive heart failure requiring transfer to a higher unit of care. Results: A total of 3731 eligible patients undergoing noncardiac surgery were analyzed; 3597 patients had complete data (1258 women [35.0%]; 1463 (40.7%) aged 75 years or older; 86 [2.4%] experienced a MACE). Discrimination of NT-proBNP or functional capacity measures added to clinical scores did not significantly differ (Area under the receiver operating curve: RCRI, age, and 4MET, 0.704; 95% CI, 0.646-0.763; RCRI, age, and 4MET plus floor climbing, 0.702; 95% CI, 0.645-0.760; RCRI, age, and 4MET plus physical activity, 0.724; 95% CI, 0.672-0.775; RCRI, age, and 4MET plus NT-proBNP, 0.736; 95% CI, 0.682-0.790). Benefit analysis favored NT-proBNP at a threshold of 5% or below, ie, if true positives were valued 20 times or more compared with false positives. The findings were similar for NSQIP MICA as baseline clinical scores. Conclusions and relevance: In this cohort study of nearly 3600 patients with elevated cardiovascular risk undergoing noncardiac surgery, there was no conclusive evidence of a difference between a NT-proBNP-based and a self-reported functional capacity-based estimate of MACE risk. Trial Registration: ClinicalTrials.gov Identifier: NCT03016936.


Assuntos
Infarto do Miocárdio , Pré-Escolar , Feminino , Humanos , Biomarcadores , Estudos de Coortes , Complicações Pós-Operatórias/epidemiologia , Valor Preditivo dos Testes , Medição de Risco , Autorrelato
5.
Semin Cardiothorac Vasc Anesth ; 27(4): 283-291, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37654159

RESUMO

Right ventricular (RV) function is complex as a number of determinants beyond preload, inotropy and afterload play a fundamental role. In particular, arterial elastance (Ea), ventriculo-arterial coupling (VAC), and (systolic) ventricular interdependence play a vital role for the right ventricle. Understanding and actively visualizing these interactions in the failing RV as well as in the altered hemodynamic and morphological situation of left ventricular assist device (LVAD) implantation may aid clinicians in their understanding of RV dysfunction and failure. While, admittedly, hard data is scarce and invasive pressure-volume loop measurements will not become routine in cardiac surgery, we hope that clinicians will benefit from the comprehensive, simulation-based review of RV pathology. In particular, the aim of this article is to first, address and clarify the pathophysiologic hemodynamic factors that lead to RV dysfunction and then, second, expand upon this basis examining the changes occurring by LVAD implantation. This is illustrated using Harvi software which shows elastance, ventricular arterial coupling, and ventricular interdependence by simultaneously showing pressure volume loops of the right and left ventricle.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Procedimentos Cirúrgicos Torácicos , Disfunção Ventricular Direita , Humanos , Hemodinâmica , Ventrículos do Coração , Disfunção Ventricular Direita/terapia , Função Ventricular Direita , Insuficiência Cardíaca/cirurgia
6.
Br J Anaesth ; 130(6): 655-665, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37012173

RESUMO

BACKGROUND: Guidelines endorse self-reported functional capacity for preoperative cardiovascular assessment, although evidence for its predictive value is inconsistent. We hypothesised that self-reported effort tolerance improves prediction of major adverse cardiovascular events (MACEs) after noncardiac surgery. METHODS: This is an international prospective cohort study (June 2017 to April 2020) in patients undergoing elective noncardiac surgery at elevated cardiovascular risk. Exposures were (i) questionnaire-estimated effort tolerance in metabolic equivalents (METs), (ii) number of floors climbed without resting, (iii) self-perceived cardiopulmonary fitness compared with peers, and (iv) level of regularly performed physical activity. The primary endpoint was in-hospital MACE consisting of cardiovascular mortality, non-fatal cardiac arrest, acute myocardial infarction, stroke, and congestive heart failure requiring transfer to a higher unit of care or resulting in a prolongation of stay on ICU/intermediate care (≥24 h). Mixed-effects logistic regression models were calculated. RESULTS: In this study, 274 (1.8%) of 15 406 patients experienced MACE. Loss of follow-up was 2%. All self-reported functional capacity measures were independently associated with MACE but did not improve discrimination (area under the curve of receiver operating characteristic [ROC AUC]) over an internal clinical risk model (ROC AUCbaseline 0.74 [0.71-0.77], ROC AUCbaseline+4METs 0.74 [0.71-0.77], ROC AUCbaseline+floors climbed 0.75 [0.71-0.78], AUCbaseline+fitnessvspeers 0.74 [0.71-0.77], and AUCbaseline+physical activity 0.75 [0.72-0.78]). CONCLUSIONS: Assessment of self-reported functional capacity expressed in METs or using the other measures assessed here did not improve prognostic accuracy compared with clinical risk factors. Caution is needed in the use of self-reported functional capacity to guide clinical decisions resulting from risk assessment in patients undergoing noncardiac surgery. CLINICAL TRIAL REGISTRATION: NCT03016936.


Assuntos
Infarto do Miocárdio , Complicações Pós-Operatórias , Humanos , Estudos Prospectivos , Autorrelato , Complicações Pós-Operatórias/etiologia , Infarto do Miocárdio/etiologia , Medição de Risco , Fatores de Risco
8.
Semin Cardiothorac Vasc Anesth ; 26(3): 209-220, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35616448

RESUMO

BACKGROUND: Viscoelastic coagulation monitoring is recommended for coagulation management after cardiac surgery, but optimum target values are poorly defined. AIMS: To determine "to-be-expected" values in rotational thromboelastometry (ROTEM) after heparin reversal, to correlate ROTEM parameters with fibrinogen levels and platelet count, and to estimate the effect of hemoglobin levels on these measurements. METHODS: We retrospectively analyzed 571 consecutive adult patients undergoing cardiac surgery with cardiopulmonary bypass from 12/2018 to 08/2020. ROTEM and conventional laboratory measurements were performed 5 to 10 minutes after protamine administration. RESULTS: Clotting times in EXTEM, INTEM, and FIBTEM were significantly prolonged (72.6%, 96.1%, and 31.8% above reference ranges, respectively). Clot firmness parameters in EXTEM and INTEM were relevantly reduced (7.9% to 14.4% and 9.1% to 32.3% below the reference ranges, respectively). There was an excellent linear correlation of FIBTEM amplitude after 10 min (A10) and of maximal clot firmness (MCF) with fibrinogen concentrations (r = .81 and .80). Areas under receiver operating characteristic (AUROC) for identifying hypofibrinogenemia <1.5 g/L were between .80 and .87. No effect of hematocrit was observed. We also found a linear correlation of EXTEM, INTEM, and EXTEM-FIBTEM at both A10 and MCF with platelet counts (.32 to .68). The AUROCs for identifying thrombocytopenia (<100,000/µL) were .79 to .84, and were greater for A10 than for MCF measurements (P=.074, .001, and <.001, respectively). CONCLUSIONS: "To-be-expected" ROTEM values after CPB are different from the published reference ranges. ROTEM parameters might allow for reliable estimation of fibrinogen level and platelet count without being influenced by hematocrit.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Tromboelastografia , Adulto , Testes de Coagulação Sanguínea , Fibrinogênio , Humanos , Estudos Retrospectivos
9.
Minerva Anestesiol ; 88(6): 448-456, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35416465

RESUMO

BACKGROUND: Postoperative pain relief remains a key problem after surgery. Multimodal pain therapy has proven beneficial in alleviating pain to a certain extent. However, when combining non-opioids, the focus has been on NSAIDs and paracetamol, but effects of combined use are only moderate. Metamizole could be a potent adjunct, due to its preclusion in several countries, data on its combined use are sparse, despite its common use in many countries. The aim of this study was to examine whether the combination of metamizole and ibuprofen is superior in relieving postoperative pain to either drug alone. METHODS: For this randomized, placebo-controlled, cross-over study, 35 patients undergoing bilateral lower third molar extraction were randomized. Each patient received three applications of 1000 mg metamizole + 400 mg ibuprofen for surgery on one side and either 1000 mg metamizole + placebo or 400 mg ibuprofen + placebo on the other side. Pain ratings, rescue-medication (tramadol), and sleep were assessed for 18 hours. RESULTS: The combined treatment of metamizole and ibuprofen showed lower mean pain scores over 12 hours than ibuprofen (2.4±1.3 vs 3.8±1.6; P=0.005). Further, combined treatment showed lower mean pain scores over 6 hours than ibuprofen (2.0±1.2 vs. 3.1±1.6; P=0.022) or metamizole alone (2.0±1.2 vs. 3.3±1.7; P=0.015). Consumption of rescue medication was lowest in the combination-group (25% vs. 46%-metamizole; 50%-ibuprofen). The trial was stopped prematurely as the COVID-pandemic halted elective surgeries. CONCLUSIONS: Combined use enables superior pain control compared to ibuprofen after molar extraction and tends to be superior to metamizole alone. The premature study-termination may overestimate this effect.


Assuntos
COVID-19 , Ibuprofeno , Analgésicos/uso terapêutico , Estudos Cross-Over , Dipirona/uso terapêutico , Método Duplo-Cego , Humanos , Ibuprofeno/uso terapêutico , Dor Pós-Operatória/tratamento farmacológico
11.
Br J Anaesth ; 128(4): 599-602, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35086686

RESUMO

Preoperative anaemia is common and associated with increased postoperative morbidity and mortality after cardiac surgery. These findings are supported by a large Dutch cohort study including >35 000 patients published in this issue of the British Journal of Anaesthesia. Timely diagnosis and preoperative anaemia treatment seem to be reasonable targets for perioperative risk stratification and modification. However, implementation of anaemia therapy into clinical routines remains challenging, and evidence for improved outcome is currently limited.


Assuntos
Anemia , Procedimentos Cirúrgicos Cardíacos , Anemia/complicações , Anemia/diagnóstico , Anemia/terapia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Estudos de Coortes , Humanos , Cuidados Pré-Operatórios , Resultado do Tratamento
12.
Anesth Analg ; 132(5): 1400-1409, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33857980

RESUMO

BACKGROUND: Assessing diastolic dysfunction is essential and should be part of every routine echocardiography examination. However, clinicians routinely observe lower mitral annular velocities by transesophageal echocardiography (TEE) under anesthesia than described by awake transthoracic echocardiography (TTE). It would be important to know whether this difference persists under constant loading conditions. We hypothesized that mean early diastolic mitral annular velocity, measured by tissue Doppler imaging (TDI, JOURNAL/asag/04.03/00000539-202105000-00029/inline-graphic1/v/2021-04-15T211206Z/r/image-tiff) would be different in the midesophageal 4-chamber (ME 4Ch) than in the apical 4-chamber (AP 4Ch) view under unchanged or constant loading conditions. Secondarily we examined (1) JOURNAL/asag/04.03/00000539-202105000-00029/inline-graphic2/v/2021-04-15T211206Z/r/image-tiff in an alternative transesophageal view with presumed superior Doppler beam alignment, the deep transgastric view (DTG), compared to those in the AP 4Ch, and (2) early diastolic speckle tracking-based strain rate (JOURNAL/asag/04.03/00000539-202105000-00029/inline-graphic3/v/2021-04-15T211206Z/r/image-tiff), in the ME 4Ch and in the AP 4Ch. METHODS: Twenty-five consecutive adult patients undergoing on-pump cardiac surgery from February 2017 to July 2017 were included. Both TTE and TEE measurements were obtained under anesthesia in a randomized order in the AP 4Ch, ME 4Ch, and DTG views. Within-patient average values were compared by paired t tests with a Bonferroni adjustment. Box plots, correlation, and agreement by Bland-Altman were examined for all 3 comparisons. A second echocardiographer independently acquired and analyzed images; images were reanalyzed after 4 weeks. Image quality and reproducibility were also reported. RESULTS: Averaged JOURNAL/asag/04.03/00000539-202105000-00029/inline-graphic4/v/2021-04-15T211206Z/r/image-tiff measurements were lower in the ME 4Ch than in the AP 4Ch (6.6 ± 1.7 cm/s vs 7.0 ± 1.5 cm, P = .028; within-patient difference mean ± standard deviation: 0.6 ± 1.2 cm/s). An alternative TEE view for JOURNAL/asag/04.03/00000539-202105000-00029/inline-graphic5/v/2021-04-15T211206Z/r/image-tiff, the DTG, also exhibited lower mean values (6.0 ± 1.6 cm/s, P = .006; within-patient difference mean ± standard deviation: 1.1 ± 1.8 cm/s). JOURNAL/asag/04.03/00000539-202105000-00029/inline-graphic6/v/2021-04-15T211206Z/r/image-tiff strain rate showed a low degree of bias, but greater variability (ME 4Ch: 0.87 ± 0.32%/s vs AP 4Ch: 0.73 ± 0.18%/s, P = .078; within-patient difference mean ± standard deviation: -0.1 ± 0.2%/s). CONCLUSIONS: This study confirms that TEE modestly underestimates JOURNAL/asag/04.03/00000539-202105000-00029/inline-graphic7/v/2021-04-15T211206Z/r/image-tiff but not to a clinically relevant extent. While JOURNAL/asag/04.03/00000539-202105000-00029/inline-graphic8/v/2021-04-15T211206Z/r/image-tiff in the DTG is not a promising alternative, the future role for speckle tracking-based early diastolic strain rate is unknown.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ponte Cardiopulmonar , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Bélgica , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ponte Cardiopulmonar/efeitos adversos , Diástole , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Disfunção Ventricular Esquerda/fisiopatologia
14.
J Ultrasound Med ; 39(11): 2151-2164, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32426900

RESUMO

OBJECTIVES: A rapid, reliable quantitative assessment of left ventricular systolic and diastolic function is important for patient treatment in urgent and dynamic settings. Quantification of annular velocities based on a single 2-dimensional image loop, rather than on Doppler velocities, could be useful in point-of-care or focused cardiac ultrasound. We hypothesized that novel speckle-tracking-based mitral annular velocities would correlate with reference standard tissue Doppler imaging (TDI) velocities in a focused cardiac ultrasound-esque setting. METHODS: Two echocardiographers each performed transthoracic echocardiographic measurements before and after induction of anesthesia in supine patients undergoing cardiac surgery. Speckle-tracking echocardiography (STE)-based systolic (S'STE ) and diastolic (E'STE and A'STE ) velocities were compared to TDI and global longitudinal strain/strain rate. We also compared mitral annular displacement by speckle tracking with M-mode imaging. RESULTS: Twenty-five patients were included and examined in both preinduction and postinduction states. Speckle-tracking-based velocities correlated with TDI measurements in both states (S', r = 0.73 and 0.76; E', r = 0.87 and 0.65; and A', r = 0.65 and 0.73), showing a mean bias of 25% to 30% of the reference standard measurement. The correlation of S'STE with strain and the strain rate (S-wave) and E'STE with the strain rate (E-wave) was good in awake, spontaneously breathing patients but was less strong in the ventilated state. Similarly, displacement by speckle tracking correlated with M-mode measurements in both states (r = 0.91 and 0.84). Measurements required medians of 31 and 34 seconds; reproducibility was acceptable for S'STE and E'STE . CONCLUSIONS: Speckle-tracking-based mitral annular velocities and displacement correlate well with conventional measures as well as with deformation imaging. They may be clinically useful in rapidly assessing both systolic and diastolic function from a single 2-dimensional image loop.


Assuntos
Ecocardiografia , Sistemas Automatizados de Assistência Junto ao Leito , Diástole , Humanos , Reprodutibilidade dos Testes , Sístole , Função Ventricular Esquerda
15.
J Cardiothorac Vasc Anesth ; 34(8): 2152-2161, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32423734

RESUMO

OBJECTIVE: First, to compare tricuspid annular displacement and velocity in transthoracic and transesophageal echocardiography (TTE, TEE) using conventional angle-dependent technologies. Second, to evaluate both alternative TEE views as well as an alternative technology (speckle tracking) for overcoming proposed differences in TTE and TEE. DESIGN: Prospective, comparative, cross-over study with a randomized order of image acquisition. SETTING: University hospital. PARTICIPANTS: Adults undergoing cardiac surgery. INTERVENTIONS: Postinduction standardized image acquisition and analysis in TTE and TEE by 2 echocardiographers. MEASUREMENTS AND MAIN RESULTS: The authors measured tricuspid annular plane systolic excursion (TAPSE) by M-mode and velocity by tissue Doppler (S') in the apical 4-chamber TTE view and midesophageal 4-chamber TEE view (AP4C, ME4C). They then examined (1) the same measurements in alternative TEE views with proposed better ultrasound angulation; and (2) speckle tracking-based endpoints (TAPSE by speckle tracking, strain, and strain rate). Data were available in 24 of 25 patients. Conventional TAPSE by M-mode and velocity by tissue Doppler (TDI) were underestimated in the ME4C compared with the AP4C reference (mean ± standard deviation: TAPSE: 13.1 ± 3.8 mm v 17.3 ± 4.0 mm; S': 6.7 ± 2.1 cm/s v 9.1 ± 2.2 cm/s; both p < 0.001). Neither a modified deep transgastric view (TAPSE 14.5 ± 4.7 mm, p = 0.017; S' 6.8 ± 1.8 cm/s, p < 0.001) nor a transgastric right ventricular inflow view (TAPSE 12.3 ± 4.0 mm, p = 0.001; S' 6.0 ± 1.3 cm/s, p < 0.001) was similar to the AP4C. Speckle tracking TAPSE was unbiased but with high variability (mean bias = -0.3 mm, 95% limits of agreement = -9.1 to 8.4); strain and strain rate were higher in TEE than for TTE (-17.7 ± 3.6 v -12.6 ± 2.1, p < 0.001; -1.0 ± 0.2/s v -0.7 ± 0.1/s, p < 0.001). CONCLUSIONS: Right ventricular displacement, velocity, and myocardial deformation measured by TEE versus TTE are different. Neither alternative transesophageal echocardiography views nor speckle tracking-based deformation is promising; TAPSE by speckle tracking is unbiased but imprecise.


Assuntos
Ecocardiografia , Disfunção Ventricular Direita , Adulto , Estudos Cross-Over , Ecocardiografia Transesofagiana , Humanos , Estudos Prospectivos , Sístole , Função Ventricular Direita
16.
Eur J Anaesthesiol ; 36(11): 871-880, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31567573

RESUMO

BACKGROUND: Postoperative nausea and/or vomiting (PONV) is one of the anaesthesia-related effects most dreaded by patients and may delay hospital discharge. Although scores and risk factors are established, many were developed before contemporary anaesthesia regimens and without focussing on modifiable anaesthesia-related variables. OBJECTIVE: To examine whether, in association with a contemporary anaesthesia regimen, there is an association between intra-operative fentanyl dose and PONV, and, second, postoperative pain within the first 24 h. DESIGN: Prospective, observational cohort. SETTING: Single-centre university hospital. PATIENTS: Inclusion criteria were opioid-naive patients without chronic pain and with a simplified Apfel score at least 2 undergoing abdominal, gynaecological or otorhinolaryngological inpatient surgery. INTERVENTION: None. MAIN OUTCOME MEASURE: With logistic regression, we examined three models of increasing complexity exploring the relationship between PONV and fentanyl dosing: Model 1, simplified Apfel score + intra-operative fentanyl; Model 2, Model 1 + pre-emptive antiemetic prophylaxis; Model 3, Model 2 + postoperative morphine. Model 1 was the primary analysis. Second, we explored whether or not postoperative pain scores were associated with intra-operative fentanyl dosing. RESULTS: From the 363 patients, 163 (45%) experienced PONV, despite the use of total intravenous anaesthesia with propofol in more than 80% of the cohort, and some 66% of patients receiving additional antiemetic agents. After adjusting for the simplified Apfel score, higher intra-operative fentanyl dose was associated with PONV: odds ratio per µg h, 1.006 [95% confidence interval (CI) 1.002 to 1.010]. Including intra-operative fentanyl in the simplified Apfel score also increased the area under the receiver operator characteristics curve [0.601 (95% CI 0.555 to 0.662) vs. 0.651 (95% CI 0.594 to 0.707); P = 0.016]. Finally, a higher intra-operative fentanyl dose was associated with higher 24 h pain scores (P = 0.001) and a trend towards higher 24 h morphine requirements (P = 0.055). CONCLUSION: Even when using propofol and antiemetic agents, PONV within the first 24 h remained higher than expected. Intra-operative fentanyl, a modifiable risk factor, is associated with the incidence of PONV and postoperative pain. TRIAL REGISTRATION: ClinicalTrials.gov, NCT03201315.


Assuntos
Anestésicos Intravenosos/administração & dosagem , Antieméticos/administração & dosagem , Fentanila/administração & dosagem , Dor Pós-Operatória/epidemiologia , Náusea e Vômito Pós-Operatórios/epidemiologia , Adulto , Idoso , Analgésicos Opioides/administração & dosagem , Anestésicos Intravenosos/efeitos adversos , Estudos de Coortes , Relação Dose-Resposta a Droga , Feminino , Fentanila/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Morfina/administração & dosagem , Dor Pós-Operatória/prevenção & controle , Náusea e Vômito Pós-Operatórios/etiologia , Propofol/administração & dosagem , Estudos Prospectivos , Fatores de Risco
18.
J Cardiothorac Vasc Anesth ; 33(10): 2636-2644, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31345717

RESUMO

OBJECTIVES: A novel speckle-tracking-based option for measuring tricuspid annular velocities in the midesophageal 4-chamber view (ME4C) was compared with velocities measured by tissue Doppler in the apical-4 chamber view (AP4C). Because this method was based on a modified speckle-tracking-based measurement of tricuspid annular plane systolic excursion (TAPSE), the authors also compared TAPSE by speckle tracking in the ME4C with TAPSE by M-mode in the AP4C. The authors hypothesized that velocities measured by speckle tracking in transesophageal echocardiography (TEE) would be similar, correlate, and agree with those measured by tissue Doppler in transthoracic echocardiography (TTE). DESIGN: Prospective diagnostic study with randomization of the order of post-induction echocardiography views by TTE (AP4C) and TEE (ME4C). Images were both acquired and analyzed by 2 echocardiographers independently. The primary outcome was S'; secondary outcomes were E', A', and TAPSE. SETTING: Single university hospital. PARTICIPANTS: Consecutive adult patients undergoing cardiac surgery (mainly coronary artery bypass grafting). INTERVENTIONS: None. MAIN RESULTS: Complete data was available in 24 of 25 patients. For the primary outcome, S' measured by speckle tracking in the ME4C correlated and agreed with S' measured by tissue Doppler in the AP4C (S'STE = 0.87STDI + 0.60, p < 0.001, r = 0.78; mean bias -0.6 cm/s, 95% limits of agreement (LoA) -3.5 to 2.4 cm/s). Similarly results were found for E', but not A' (E'STE = 0.69E'TDI + 2.37, p < 0.001, r = 0.71; mean bias 0.1 cm/s, 95%LoA -2.5 to 2.8cm/s; A'STE = 0.15A'TDI + 11.17, p = 0.629). TAPSE measurements by the authors' modified speckle-tracking-based technique were similar to TAPSE by M-mode (18.2 ± 5.5 mm and 17.1 ± 3.9 mm, respectively). CONCLUSIONS: Tricuspid annular velocities (S'STE, E'STE) determined by speckle tracking in TEE seem to be promising surrogates for velocities measured in TTE. This may be important for perioperative assessment of the right ventricle.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Valva Tricúspide/diagnóstico por imagem , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Ecocardiografia Doppler/métodos , Ecocardiografia Transesofagiana/métodos , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Reprodutibilidade dos Testes , Valva Tricúspide/fisiopatologia , Função Ventricular Direita/fisiologia
19.
J Cardiothorac Vasc Anesth ; 33(4): 1022-1028, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30448072

RESUMO

OBJECTIVES: In this measurement validation study, the authors evaluated agreement between 2-dimensional (2D) and three-dimensional (3D) transesophageal echocardiography (TEE), measuring anterior mitral valve leaflet length by both novice and experienced echocardiographers. DESIGN: This was a retrospective, observational study. SETTING: Single university hospital. PARTICIPANTS: Analyses on datasets from 44 patients. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Fifty datasets from 44 patients with mitral regurgitation were analyzed by 4 observers (2 novices, 2 experts). All observers measured the anterior mitral valve leaflet length from end-systolic 2D TEE images from the midesophageal longitudinal axis view and 3D software-augmented TEE images. The overall mean anterior mitral valve leaflet length was significantly shorter with 3D versus 2D TEE measurements (24.6 ± 4.5 mm v 26.2 ± 5.3 mm; p < 0.001), with novices measuring shorter leaflets than experts for both techniques (p < 0.001 and p = 0.005, respectively). Bland-Altman plots of 3D and 2D TEE measurements showed mean biases (95% limits of agreement) of -1.6 mm (-9.0 to 5.9 mm), -1.8 mm (-9.6 to 6.0 mm), and -1.3 mm (-8.4 to 5.7 mm) for all observers, novices, and experts, respectively. For 2D measurements, interobserver reliability was very strong among experts and strong among novices (Pearson's r = 0.83 v 0.66; p = 0.055). For 3D measurements, interobserver reliability was strong in experts and moderate in novices (Pearson's r = 0.69 v 0.51; p = 0.168). CONCLUSION: For both novices and experts, 3D TEE measurements of the anterior mitral valve leaflet were significantly shorter than 2D measurements. Interobserver reliability was lowest for novices making 3D TEE measurements, indicating that reliable, quantitative evaluation of 3D TEE may require a greater amount of practice.


Assuntos
Competência Clínica/normas , Ecocardiografia Tridimensional/normas , Ecocardiografia/normas , Prova Pericial/normas , Insuficiência da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Idoso , Ecocardiografia/métodos , Ecocardiografia Tridimensional/métodos , Prova Pericial/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA