Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39077791

RESUMO

AIMS: We aimed to evaluate transcatheter mitral valve implantation (TMVI) using predominantly balloon-expandable transcatheter heart valves (THV) in patients with a landing zone for a percutaneously delivered prosthesis. BACKGROUND: Patients with a degenerated mitral valve bioprosthesis, annuloplasty ring, and mitral annulus calcification (MAC) considered at high surgical risk currently represent a treatment challenge. TMVI is an alternative treatment option. METHODS: Retrospective analysis of patients with symptomatic degenerated mitral valve bioprosthesis, or annuloplasty ring, and MAC treated with TMVI between November 2011 and April 2021. Endpoints were defined according to Mitral Valve Academic Research Consortium (MVARC) criteria and included device and procedure success at 30 days as well as mortality at 30 days and 1 year after the procedure. RESULTS: A total of 77 patients underwent TMVI (valve in valve [ViV = 56], valve in ring [ViR = 11], and valve in MAC [ViMAC = 10]). There was a trend toward higher technical success (all = 93.5%, ViV = 96.4%, ViR = 90.9%, ViMAC = 80%, p = 0.06) and lower 30-day (all = 11.7%, ViV = 10.7%, ViR = 9.1%, ViMAC = 20%, p = 0.49) and 1-year mortality (all = 26%, ViV = 23.2%, ViR = 27.3%, ViMAC= 40%, p = 0.36) after ViV and ViR compared to ViMAC. CONCLUSION: TMVI represents a reasonable treatment option in selected patients with MAC or who are poor candidates for redo mitral valve surgery. Technical success and survival up to 1 year were not significantly dependent on the subgroup in which TMVI was performed.

2.
J Card Surg ; 36(4): 1241-1248, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33484180

RESUMO

PURPOSE: The Sentinel Cerebral Protection System (Sentinel-CPS) is increasingly used in transcatheter aortic valve replacement (TAVR). However, the impact of inserting the Sentinel-CPS inside the brain-supplying arteries on cerebral perfusion and oxygenation is unknown. METHODS: Twenty patients undergoing transfemoral TAVR with (n = 10) and without (n = 10) cerebral embolic protection using the Sentinel-CPS were prospectively observed. All patients received conscious sedation and cerebral oxygen saturation (rSO2 ) was continuously measured with near-infrared spectroscopy (NIRS). The cumulative perioperative cerebral desaturation was calculated for each patient by multiplying rSO2 below an individualized desaturation threshold by time. In addition, rSO2 values at the time of Sentinel-CPS insertion, filter positioning, and device retraction were analyzed. RESULTS: There was no significant difference in cumulative cerebral desaturation in patients with Sentinel-CPS (median [IQR]) (0 [0/81] s%) and without (median [IQR]) (0 [0/23] s%), p = .762. A total of 6 patients (33.3%) experienced a perioperative decrease in rSO2 below the individualized desaturation threshold (n = 3 with Sentinel-CPS, n = 3 without Sentinel-CPS; p = 1.000). Cerebral desaturation was detected during valve deployment (n = 5) and after postdilatation (n = 1). No desaturation events occurred during Sentinel-CPS insertion, filter positioning, or retraction. CONCLUSION: Our pilot study revealed no difference in cumulative perioperative cerebral desaturation between TAVR with and without Sentinel-CPS. Catheter- and filter-based manipulations in the brain-supplying arteries for Sentinel-CPS application were not associated with a decrease of cerebral perfusion and oxygenation.


Assuntos
Estenose da Valva Aórtica , Dispositivos de Proteção Embólica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Oxigênio , Projetos Piloto , Estudos Prospectivos , Resultado do Tratamento
3.
Am J Cardiol ; 139: 71-78, 2021 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-33190811

RESUMO

We aimed to evaluate the efficacy and safety of a low-dose imaging protocol to reduce intraprocedural radiation during transcatheter aortic valve implantation (TAVI). Observational analysis: 802 transfemoral TAVI patients receiving balloon-expandable devices ≥23 mm at a high-volume centre. After propensity score matching, a standard-dose group (SD, n = 333) treated between January 2014 and February 2016 was compared with a low-dose group (LD, n = 333) treated between August 2017 and March 2019 after departmental uptake of a low-dose imaging protocol (reduced field size, high table height, use of "fluoro save," 3.75 frames/second acquisition, increased filtering). Primary end point was dose-area product (DAP). Secondary safety end points were VARC-2 device success and a composite of in-hospital complications. The LD protocol was associated with lower DAP (4.64 [2.93, 8.42] vs 22.73 [12.31, 34.58] Gy⋅cm2, p <0.001) and fluoroscopy time (10.4 [8.1, 13.9] vs 11.5 [9.1, 15.3] minutes, p = 0.001). Contrast use was higher in the LD group (LD 110 [94, 130] vs SD 100 [80, 135] milliliters, p = 0.042). Device success (LD 88.3% vs SD 91.3%, p = 0.25), and the composite end point (LD 8.1% vs SD 11.4%, p = 0.19) were similar. In multivariate analysis, the low-dose protocol was associated with a 19.8 Gy⋅cm2 reduction in procedural DAP (p <0.001). In conclusion, compared with standard imaging, a low-dose protocol for TAVI significantly reduced radiation dose without compromising outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Fluoroscopia/métodos , Lesões por Radiação/prevenção & controle , Cirurgia Assistida por Computador/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Fatores de Risco
4.
Heart Lung Circ ; 29(6): 904-913, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31182269

RESUMO

AIM: Psoas muscle cross-sectional area (CSA) is a proposed marker of frailty associated with mortality after transcatheter aortic valve implantation (TAVI). We assessed the impact of psoas CSA on medium-term mortality over 5 years in a large cohort, adjusted for pre-procedural variables. METHOD: This single-centre registry-derived analysis assessed 1,731 consecutive TAVI patients between 2007 and 31 April 2015 with available abdominal computed tomography scans. Sex-stratified, height-adjusted psoas CSA was measured mid-body of the fourth lumbar vertebra. Kaplan-Meier survival distributions across psoas CSA quartiles were compared. Cox and logistic regression models were used to assess baseline variables associated with the primary outcome, which was mortality within 5 years. RESULTS: Median age was 81 years (interquartile range, 77 - 85); 52.5% were women. The primary endpoint occurred in 555 patients over a mean follow-up of 775 days. Lower psoas CSA quartile patients were older, had a lower body mass index, lower creatinine clearance, and lower rates of previous cardiac surgery, with higher rates of diabetes, coronary artery disease, pacemaker, anaemia, hypoalbuminaemia, and higher European System for Cardiac Operative Risk Evaluation (EuroSCORE). Unadjusted survival by psoas CSA quartile was significantly different in men (log rank p=0.041) but not women (p=0.099). In Bonferroni-adjusted multivariate analysis, psoas CSA quartiles were not significantly associated with mortality. Hypoalbuminaemia (hazard ratio [HR], 2.10; 95% confidence interval [CI], 1.53 - 2.87 [p<0.001]) and increasing age (HR, 1.03 per year; 95% CI, 1.01 - 1.05 [p=0.002]) were associated with increased risk; female sex (HR, 0.63; 95% CI 0.51 - 0.78 [p<0.001]), and hypercholesterolaemia (HR, 0.67; 95%, CI 0.54 0.83 [p<0.001]) with reduced risk. CONCLUSIONS: Psoas CSA was not significantly associated with mortality after adjusting for pre-procedural variables. Hypoalbuminaemia, sex, hypercholesterolaemia, and age were significantly associated with mortality after TAVI.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Músculos Psoas/diagnóstico por imagem , Sistema de Registros , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Alemanha/epidemiologia , Humanos , Masculino , Músculos Psoas/cirurgia , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
5.
Am J Cardiol ; 124(9): 1442-1448, 2019 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-31474326

RESUMO

Patients referred for transcatheter aortic valve implantation (TAVI) are typically elderly with several co-morbidities, which might limit prognosis despite successful procedural outcome. To date, the prevalence and clinical impact of iron deficiency (ID) in patients with severe aortic stenosis who underwent TAVI remains poorly defined. This study included 495 patients who underwent transfemoral TAVI for severe symptomatic aortic stenosis. ID was defined as ferritin <100 ng/ml or ferritin 100 to 300 ng/ml, when transferrin saturation was <20%. The primary end point of the study was a composite of all-cause mortality, unplanned readmission for worsening heart failure or red blood cell transfusions during the first year after TAVI, which occurred in 22% (109 of 495) of the population. ID was present in 54% (268 of 495) of the entire cohort and was associated with a higher rate of the primary end point (27.6% [74 of 268] vs 15.4% [35 of 227]; p = 0.001). After multivariable adjustment, the association of ID with the primary end point remained significant (hazard ratio 1.64, 95% confidence interval [1.08 to 2.48]; p = 0.019). In a subgroup of ferropenic patients (n = 56), treatment with intravenous iron before TAVI was feasible, resulting in a considerable improvement of ferritin, transferrin saturation and symptoms at 30-day follow-up. In conclusion, ID is common in TAVI patients and is associated with adverse clinical outcome after TAVI. Correction of ID with intravenous iron seems feasible in contemporary TAVI patients. Whether this reduces transfusion rates and impacts clinical outcome after TAVI remains to be investigated in future prospective trials.


Assuntos
Anemia Ferropriva/epidemiologia , Estenose da Valva Aórtica/epidemiologia , Transfusão de Eritrócitos/estatística & dados numéricos , Insuficiência Cardíaca/epidemiologia , Mortalidade , Readmissão do Paciente/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter , Administração Intravenosa , Idoso , Idoso de 80 Anos ou mais , Anemia Ferropriva/tratamento farmacológico , Anemia Ferropriva/metabolismo , Estenose da Valva Aórtica/cirurgia , Feminino , Ferritinas/metabolismo , Alemanha/epidemiologia , Humanos , Ferro/uso terapêutico , Masculino , Cuidados Pré-Operatórios , Prevalência , Modelos de Riscos Proporcionais , Encaminhamento e Consulta , Índice de Gravidade de Doença , Oligoelementos/uso terapêutico , Transferrina/metabolismo
6.
PLoS One ; 14(1): e0210872, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30699164

RESUMO

OBJECTIVE: Transfemoral Transcatheter Aortic Valve Implantation (TAVI) has become a standard therapy for patients with aortic valve stenosis. Fluoroscopic imaging is essential for TAVI with the anesthesiologist's workplace close to patient's head side. While the use of lead-caps has been shown to be useful for interventional cardiologists, data are lacking for anesthesiologists. METHODS: A protective cap with a 0.35 lead-equivalent was worn on 15 working days by one anesthesiologist. Six detectors (three outside, three inside) were analyzed to determine the reduction of radiation. Literature search was conducted between April and October 2018. RESULTS: In the observational period, 32 TAVI procedures were conducted. A maximum radiation dose of 0.55 mSv was detected by the dosimeters at the outside of the cap. The dosimeters inside the cap, in contrast, displayed a constant radiation dose of 0.08 mSv. CONCLUSION: The anesthesiologist's head is exposed to significant radiation during TAVI and it can be protected by wearing a lead-cap.


Assuntos
Anestesiologistas , Fluoroscopia/efeitos adversos , Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica/instrumentação , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Cineangiografia/efeitos adversos , Feminino , Cabeça , Dispositivos de Proteção da Cabeça , Humanos , Chumbo , Masculino , Projetos Piloto , Roupa de Proteção , Doses de Radiação , Radiometria , Fatores de Risco
7.
Can J Anaesth ; 65(6): 647-657, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29464420

RESUMO

PURPOSE: Different sedation regimens have been described for use during transfemoral transcatheter aortic valve implantation (tf-TAVI) for treatment in patients with severe aortic stenosis. The purpose of this study was to compare dexmedetomidine (DEX) with a combination of propofol-opioid (PO) with respect to periprocedural gas exchange and hemodynamic support. METHODS: Data from a cohort of patients sedated with either DEX or PO for tf-TAVI were retrospectively analyzed from a prospectively maintained TAVI registry. Operative risk was determined from comorbidities and risk scores. Periprocedural partial pressure of carbon dioxide (PaCO2) was chosen as the primary endpoint. Other differences in gas exchange, need for catecholamine therapy, the frequency of conversion to general anesthesia, and need for sedative "rescue therapy" (in DEX patients) were secondary endpoints. Inverse probability of treatment weighting (IPTW) was used for analysis to minimize any selection bias. RESULTS: Of the 297 patients (140 PO, 157 DEX) included, the median [interquartile range] periprocedural PaCO2 values of DEX patients were significantly lower than in PO patients (40 [36-45] mmHg vs 44 [40-49] mmHg, respectively; median difference -4 mmHg; 95% confidence interval, -5 to -3 mmHg; P < 0.001). Hypercapnia (PaCO2 > 45 mmHg) was significantly less frequent in DEX patients compared with the PO group (25% vs 42%, respectively; P = 0.005). Vasopressor support was more frequent in the PO group compared with DEX (68% vs 25%, respectively; P < 0.001). Conversion to general anesthesia was not different between groups (9%, PO vs 3%, DEX; P = 0.051). Additional sedatives/opioids were required in 25 (16%) of the DEX patients. CONCLUSIONS: In sedated TAVI patients, DEX was associated with lower PaCO2 values and reduced requirements for vasopressor support, making it a promising alternative to PO for sedation during TAVI. TRIAL REGISTRATION: www.ClinicalTrials.gov (NCT01390675). Registered 11 July 2011.


Assuntos
Analgésicos Opioides , Sedação Consciente/métodos , Dexmedetomidina , Hipnóticos e Sedativos , Propofol , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Anestesia Geral , Estenose da Valva Aórtica/cirurgia , Dióxido de Carbono/sangue , Estudos de Coortes , Determinação de Ponto Final , Feminino , Hemodinâmica , Humanos , Masculino , Troca Gasosa Pulmonar , Estudos Retrospectivos , Medição de Risco
8.
Catheter Cardiovasc Interv ; 92(1): 149-156, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29130616

RESUMO

BACKGROUND: Although the incidence of periprocedural complications has decreased in transcatheter aortic valve implantation (TAVI), life-threatening complications occur and emergency veno-arterial extracorporeal membrane oxygenation (vaECMO) can provide immediate circulatory stabilization. We report our two-center experience of vaECMO during life-threatening complications in TAVI. METHODS: From January 2010 to December 2015, 1,810 consecutive patients underwent TAVI at two centers. Clinical characteristics, type of complication, outcome and temporal trends in the requirement of emergency vaECMO were evaluated. RESULTS: Life-threatening complications requiring vaECMO occurred in 1.8% of cases (33 patients; 22 transfemoral, 11 transapical). Indications for vaECMO were ventricular rupture (30%, 10/33), low output (15%, 5/33), bleeding (12%, 4/33), coronary artery impairment (9%, 3/33), ventricular arrhythmias (6%, 2/33), severe aortic regurgitation (6%, 2/33), aortic annular rupture (6%, 2/33), and aortic dissection (3%, 1/33). In 4 cases, no definite cause for hemodynamic instability was identified. Conversion to open heart surgery was necessary in 42% of patients (14/33). Percutaneous coronary intervention was performed in all cases with coronary artery impairment (9%, 3/33). Patients with severe aortic regurgitation (6%, 2/33) underwent emergency valve-in-valve implantation. Other patients received, in addition to vaECMO support conservative treatment (42%, 14/33). In-hospital mortality and 30-day mortality were 46% (15/33). Of patients discharged, 67% (12/18) had no neurological impairment, whereas mild and severe neurological impairment was found in 11% (2/18) and 22% (4/18), respectively. From 2010 to 2015, with increasing procedures (from n = 43 to n = 553) requirement of vaECMO decreased from 9.3% to 0.9% (P for the trend <0.001). CONCLUSION: Over a 6-year period, need for emergency vaECMO during TAVI significantly decreased over time. Despite high in-hospital mortality, vaECMO represents a feasible strategy for hemodynamic support in case of life-threatening complications.


Assuntos
Valva Aórtica/cirurgia , Oxigenação por Membrana Extracorpórea , Doenças das Valvas Cardíacas/cirurgia , Complicações Pós-Operatórias/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Emergências , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/mortalidade , Feminino , Alemanha , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Mortalidade Hospitalar , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/mortalidade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
9.
Int J Cardiol ; 244: 93-99, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-28645804

RESUMO

INTRODUCTION: Anemia is frequent in patients undergoing transcatheter aortic valve implantation (TAVI) with a strong negative prognostic impact. The prevalence and prognosis of anemia and separately of iron-deficiency anemia in contemporary patients are unclear. METHODS AND RESULTS: In total, 549 consecutive patients undergoing transfemoral TAVI were included in the single-center study. Baseline anemia was defined as a hemoglobin level <13g/dL in men and <12g/dL in women. In an unselected subgroup of anemic patients (n=115), a complete iron status was obtained and anemia was classified as iron-deficiency versus non-iron-deficiency. The primary endpoint was death or re-hospitalization for worsening heart failure within one year after TAVI. Anemia was present in 45% (249/549) of the population and was significantly associated with a higher rate of the primary endpoint (25% (63/249) vs. 8% (25/300); p<0.001). In a multivariable model adjusted for variables associated with the primary endpoint, baseline anemia was an independent predictor of the primary endpoint (hazard ratio 2.81, 95% confidence interval [1.69-4.67]; p<0.001). Iron-deficiency anemia was present in 79% (91/115) of the subgroup and the rate of the primary endpoint was comparable to non-iron-deficiency anemia (31% (28/91) vs. 21% (5/24); p=0.338). CONCLUSION: In contemporary TAVI patients, anemia remains a common comorbidity and independently predicts adverse outcome. In an unselected subgroup of anemic patients, iron-deficiency was common and had similar clinical outcome compared to non-iron-deficiency. Whether correction of iron-deficiency anemia impacts prognosis remains to be investigated.


Assuntos
Anemia Ferropriva/diagnóstico , Anemia Ferropriva/cirurgia , Substituição da Valva Aórtica Transcateter/tendências , Idoso , Idoso de 80 Anos ou mais , Anemia/diagnóstico , Anemia/mortalidade , Anemia/cirurgia , Anemia Ferropriva/mortalidade , Estudos de Coortes , Feminino , Humanos , Masculino , Readmissão do Paciente/tendências , Prognóstico , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/mortalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA