Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Radiol Clin North Am ; 60(6): 941-950, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36202480

RESUMO

Lung injury associated with smoking tobacco or other substances results in a variety of clinical presentations and imaging patterns, depending on mechanism of injury and substance inhaled. Patients may present in the acute setting, as in the case of acute eosinophilic pneumonia, e-cigarette or vaping product use-associated lung injury, crack lung, or heroin inhalation. They may present with subacute shortness of breath and demonstrate findings of pulmonary Langerhans cell histiocytosis, respiratory bronchiolitis, or desquamative interstitial pneumonia. Alternatively, they may present with chronic dyspnea and demonstrate findings of emphysema or smoking-related interstitial lung fibrosis.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Lesão Pulmonar , Vaping , Heroína , Humanos , Lesão Pulmonar/diagnóstico por imagem , Lesão Pulmonar/etiologia , Fumar , Vaping/efeitos adversos
2.
J Am Coll Radiol ; 18(9): 1267-1279, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34246574

RESUMO

The ACR Incidental Findings Committee presents recommendations for managing incidentally detected lung findings on thoracic CT. The Chest Subcommittee is composed of thoracic radiologists who endorsed and developed the provided guidance. These recommendations represent a combination of current published evidence and expert opinion and were finalized by informal iterative consensus. The recommendations address commonly encountered incidental findings in the lungs and are not intended to be a comprehensive review of all pulmonary incidental findings. The goal is to improve the quality of care by providing guidance on management of incidentally detected thoracic findings.


Assuntos
Achados Incidentais , Tomografia Computadorizada por Raios X , Consenso , Humanos , Pulmão , Radiologistas
3.
Radiology ; 301(1): 211-220, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34313473

RESUMO

Background Recent studies demonstrate that antifibrotic drugs previously reserved for idiopathic pulmonary fibrosis (IPF) may slow progression in other interstitial lung diseases (ILDs), creating an urgent need for tools that can sensitively assess disease activity, progression, and therapy response across ILDs. Hyperpolarized xenon 129 (129Xe) MRI and spectroscopy have provided noninvasive measurements of regional gas-exchange abnormalities in IPF. Purpose To assess gas exchange function using 129Xe MRI in a group of study participants with nonspecific interstitial pneumonia (NSIP) compared with healthy control participants. Materials and Methods In this prospective study, participants with NSIP and healthy control participants were enrolled between November 2017 and February 2020 and underwent 129Xe MRI and spectroscopy. Quantitative imaging provided three-dimensional maps of ventilation, interstitial barrier uptake, and transfer into the red blood cell (RBC) compartment. Spectroscopy provided parameters of the static RBC and barrier uptake compartments, as well as cardiogenic oscillations in RBC signal amplitude and chemical shift. Differences between NSIP and healthy control participants were assessed using the Wilcoxon rank-sum test. Results Thirty-six participants with NSIP (mean age, 57 years ± 11 [standard deviation]; 27 women) and 15 healthy control participants (mean age, 39 years ± 18; two women) were evaluated. Participants with NSIP had no difference in ventilation compared with healthy control participants (median, 4.4% [first quartile, 1.5%; third quartile, 8.7%] vs 6.0% [first quartile, 2.8%; third quartile, 6.9%]; P = .91), but they had a higher barrier uptake (median, 6.2% [first quartile, 1.8%; third quartile, 23.9%] vs 0.53% [first quartile, 0.33%; third quartile, 2.9%]; P = .003) and an increased RBC transfer defect (median, 20.6% [first quartile, 11.6%; third quartile, 27.8%] vs 2.8% [first quartile, 2.3%; third quartile, 4.9%]; P < .001). NSIP participants also had a reduced ratio of RBC-to-barrier peaks (median, 0.24 [first quartile, 0.19; third quartile, 0.31] vs 0.57 [first quartile, 0.52; third quartile, 0.67]; P < .001) and a reduced RBC chemical shift (median, 217.5 ppm [first quartile, 217.0 ppm; third quartile, 218.0 ppm] vs 218.2 ppm [first quartile, 217.9 ppm; third quartile, 218.6 ppm]; P = .001). Conclusion Participants with nonspecific interstitial pneumonia had increased barrier uptake and decreased red blood cell (RBC) transfer compared with healthy controls measured using xenon 129 gas-exchange MRI and reduced RBC-to-barrier ratio and RBC chemical shift measured using spectroscopy. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Wild in this issue.


Assuntos
Doenças Pulmonares Intersticiais/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Troca Gasosa Pulmonar , Isótopos de Xenônio , Adulto , Estudos Transversais , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Análise Espectral/métodos
5.
NMR Biomed ; 32(1): e4029, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30457202

RESUMO

The spectral parameters of hyperpolarized 129 Xe exchanging between airspaces, interstitial barrier, and red blood cells (RBCs) are sensitive to pulmonary pathophysiology. This study sought to evaluate whether the dynamics of 129 Xe spectroscopy provide additional insight, with particular focus on quantifying cardiogenic oscillations in the RBC resonance. 129 Xe spectra were dynamically acquired in eight healthy volunteers and nine subjects with idiopathic pulmonary fibrosis (IPF). 129 Xe FIDs were collected every 20 ms (TE  = 0.932 ms, 512 points, dwell time = 32 µs, flip angle ≈ 20°) during a 16 s breathing maneuver. The FIDs were pre-processed using the spectral improvement by Fourier thresholding technique (SIFT) and fit in the time domain to determine the airspace, interstitial barrier, and RBC spectral parameters. The RBC and gas resonances were fit to a Lorentzian lineshape, while the barrier was fit to a Voigt lineshape to account for its greater structural heterogeneity. For each complex resonance the amplitude, chemical shift, linewidth(s), and phase were calculated. The time-averaged spectra confirmed that the RBC to barrier amplitude ratio (RBC:barrier ratio) and RBC chemical shift are both reduced in IPF subjects. Their temporal dynamics showed that all three 129 Xe resonances are affected by the breathing maneuver. Most notably, several RBC spectral parameters exhibited prominent oscillations at the cardiac frequency, and their peak-to-peak variation differed between IPF subjects and healthy volunteers. In the IPF cohort, oscillations were more prominent in the RBC amplitude (16.8 ± 5.2 versus 9.7 ± 2.9%; P = 0.008), chemical shift (0.43 ± 0.33 versus 0.083 ± 0.05 ppm; P < 0.001), and phase (7.7 ± 5.6 versus 1.4 ± 0.8°; P < 0.001). Dynamic 129 Xe spectroscopy is a simple and sensitive tool that probes the temporal variability of gas exchange and may prove useful in discerning the underlying causes of its impairment.


Assuntos
Fibrose Pulmonar Idiopática/diagnóstico por imagem , Espectroscopia de Ressonância Magnética , Isótopos de Xenônio/química , Adulto , Idoso , Eritrócitos/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Adulto Jovem
6.
Magn Reson Med ; 78(4): 1306-1315, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28940334

RESUMO

PURPOSE: The purpose of this work was to accurately characterize the spectral properties of hyperpolarized 129 Xe in patients with idiopathic pulmonary fibrosis (IPF) compared to healthy volunteers. METHODS: Subjects underwent hyperpolarized 129 Xe breath-hold spectroscopy, during which 38 dissolved-phase free induction decays (FIDs) were acquired after reaching steady state (echo time/repetition time = 0.875/50 ms; bandwidth = 8.06 kHz; flip angle≈22 °). FIDs were averaged and then decomposed into multiple spectral components using time-domain curve fitting. The resulting amplitudes, frequencies, line widths, and starting phases of each component were compared among groups using a Mann-Whitney-Wilcoxon U test. RESULTS: Three dissolved-phase resonances, consisting of red blood cells (RBCs) and two barrier compartments, were consistently identified in all subjects. In subjects with IPF relative to healthy volunteers, the RBC frequency was 0.70 parts per million (ppm) more negative (P = 0.05), the chemical shift of barrier 2 was 0.6 ppm more negative (P = 0.009), the line widths of both barrier peaks were ∼2 ppm narrower (P < 0.001), and the starting phase of barrier 1 was 20.3 ° higher (P = 0.01). Moreover, the ratio RBC:barriers was reduced by 52.9% in IPF (P < 0.001). CONCLUSIONS: The accurate decomposition of 129 Xe spectra not only has merit for developing a global metric of pulmonary function, but also provides necessary insights to optimize phase-sensitive methods for imaging 129 Xe gas transfer. Magn Reson Med 78:1306-1315, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Fibrose Pulmonar Idiopática/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Isótopos de Xenônio/uso terapêutico , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Processamento de Sinais Assistido por Computador , Adulto Jovem
7.
Med Phys ; 44(6): 2415-2428, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28382694

RESUMO

PURPOSE: Hyperpolarized 129 Xe magnetic resonance imaging (MRI) using Dixon-based decomposition enables single-breath imaging of 129 Xe in the airspaces, interstitial barrier tissues, and red blood cells (RBCs). However, methods to quantitatively visualize information from these images of pulmonary gas transfer are lacking. Here, we introduce a novel method to transform these data into quantitative maps of pulmonary ventilation, and 129 Xe gas transfer to barrier and RBC compartments. METHODS: A total of 13 healthy subjects and 12 idiopathic pulmonary fibrosis (IPF) subjects underwent thoracic 1 H MRI and hyperpolarized 129 Xe MRI with one-point Dixon decomposition to obtain images of 129 Xe in airspaces, barrier and red blood cells (RBCs). 129 Xe images were processed into quantitative binning maps of all three compartments using thresholds based on the mean and standard deviations of distributions derived from the healthy reference cohort. Binning maps were analyzed to derive quantitative measures of ventilation, barrier uptake, and RBC transfer. This method was also used to illustrate different ventilation and gas transfer patterns in a patient with emphysema and one with pulmonary arterial hypertension (PAH). RESULTS: In the healthy reference cohort, the mean normalized signals were 0.51 ± 0.19 for ventilation, 4.9 ± 1.5 x 10-3 for barrier uptake and 2.6 ± 1.0 × 10-3 for RBC (transfer). In IPF patients, ventilation was similarly homogenous to healthy subjects, although shifted toward slightly lower values (0.43 ± 0.19). However, mean barrier uptake in IPF patients was nearly 2× higher than in healthy subjects, with 47% of voxels classified as high, compared to 3% in healthy controls. Moreover, in IPF, RBC transfer was reduced, mainly in the basal lung with 41% of voxels classified as low. In healthy volunteers, only 15% of RBC transfer was classified as low and these voxels were typically in the anterior, gravitationally nondependent lung. CONCLUSIONS: This study demonstrates a straightforward means to generate semiquantitative binning maps depicting 129 Xe ventilation and gas transfer to barrier and RBC compartments. These initial results suggest that the method could be valuable for characterizing both normal physiology and pathophysiology associated with a wide range of pulmonary disorders.


Assuntos
Imageamento por Ressonância Magnética , Enfisema Pulmonar/diagnóstico por imagem , Ventilação Pulmonar , Humanos , Pulmão , Isótopos de Xenônio
8.
Radiology ; 282(1): 236-250, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27439324

RESUMO

Purpose To conduct a multi-institutional, multireader study to compare the performance of digital tomosynthesis, dual-energy (DE) imaging, and conventional chest radiography for pulmonary nodule detection and management. Materials and Methods In this binational, institutional review board-approved, HIPAA-compliant prospective study, 158 subjects (43 subjects with normal findings) were enrolled at four institutions. Informed consent was obtained prior to enrollment. Subjects underwent chest computed tomography (CT) and imaging with conventional chest radiography (posteroanterior and lateral), DE imaging, and tomosynthesis with a flat-panel imaging device. Three experienced thoracic radiologists identified true locations of nodules (n = 516, 3-20-mm diameters) with CT and recommended case management by using Fleischner Society guidelines. Five other radiologists marked nodules and indicated case management by using images from conventional chest radiography, conventional chest radiography plus DE imaging, tomosynthesis, and tomosynthesis plus DE imaging. Sensitivity, specificity, and overall accuracy were measured by using the free-response receiver operating characteristic method and the receiver operating characteristic method for nodule detection and case management, respectively. Results were further analyzed according to nodule diameter categories (3-4 mm, >4 mm to 6 mm, >6 mm to 8 mm, and >8 mm to 20 mm). Results Maximum lesion localization fraction was higher for tomosynthesis than for conventional chest radiography in all nodule size categories (3.55-fold for all nodules, P < .001; 95% confidence interval [CI]: 2.96, 4.15). Case-level sensitivity was higher with tomosynthesis than with conventional chest radiography for all nodules (1.49-fold, P < .001; 95% CI: 1.25, 1.73). Case management decisions showed better overall accuracy with tomosynthesis than with conventional chest radiography, as given by the area under the receiver operating characteristic curve (1.23-fold, P < .001; 95% CI: 1.15, 1.32). There were no differences in any specificity measures. DE imaging did not significantly affect nodule detection when paired with either conventional chest radiography or tomosynthesis. Conclusion Tomosynthesis outperformed conventional chest radiography for lung nodule detection and determination of case management; DE imaging did not show significant differences over conventional chest radiography or tomosynthesis alone. These findings indicate performance likely achievable with a range of reader expertise. © RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/terapia , Intensificação de Imagem Radiográfica/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Radiografia Torácica , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Suécia , Tomografia Computadorizada por Raios X , Estados Unidos , Ecrans Intensificadores para Raios X
9.
Diagn Interv Radiol ; 22(3): 224-30, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27015318

RESUMO

PURPOSE: We aimed to describe our initial experience with percutaneous transthoracic localization (PTL) of pulmonary nodules using a C-arm cone-beam CT (CBCT) virtual navigation guidance system. METHODS: From February 2013 to March 2014, 79 consecutive patients (mean age, 61±10 years) with 81 solid or ground-glass nodules (mean size, 12.36±7.21 mm; range, 4.8-25 mm) underwent PTLs prior to video-assisted thoracoscopic surgery (VATS) excision under CBCT virtual navigation guidance using lipiodol (mean volume, 0.18±0.04 mL). Their procedural details, radiation dose, and complication rates were described. RESULTS: All 81 target nodules were successfully localized within 10 mm (mean distance, 2.54±3.24 mm) from the lipiodol markings. Mean number of CT acquisitions was 3.2±0.7, total procedure time was 14.6±5.14 min, and estimated radiation exposure during the localization was 5.21±2.51 mSv. Postprocedural complications occurred in 14 cases (17.3%); complications were minimal pneumothorax (n=10, 12.3%), parenchymal hemorrhage (n=3, 3.7%), and a small amount of hemoptysis (n=1, 1.2%). All target nodules were completely resected; pathologic diagnosis included invasive adenocarcinoma (n=53), adenocarcinoma-in-situ (n=10), atypical adenomatous hyperplasia (n=4), metastasis (n=7), and benign lesions (n=7). CONCLUSION: PTL procedures can be performed safely and accurately under the guidance of a CBCT virtual navigation system.


Assuntos
Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/cirurgia , Idoso , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista/métodos , Radiografia Torácica/métodos , Cirurgia Torácica Vídeoassistida/métodos
10.
Eur Radiol ; 26(6): 1529-37, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26385803

RESUMO

OBJECTIVE: To investigate the natural course of persistent pulmonary subsolid nodules (SSNs) with solid portions ≤5 mm and the clinico-radiological features that influence interval growth over follow-ups. METHODS: From 2005 to 2013, the natural courses of 213 persistent SSNs in 213 patients were evaluated. To identify significant predictors of interval growth, Kaplan-Meier analysis and Cox proportional hazard regression analysis were performed. RESULTS: Among the 213 nodules, 136 were pure ground-glass nodules (GGNs; growth, 18; stable, 118) and 77 were part-solid GGNs with solid portions ≤5 mm (growth, 24; stable, 53). For all SSNs, lung cancer history (p = 0.001), part-solid GGNs (p < 0.001), and nodule diameter (p < 0.001) were significant predictors for interval growth. On subgroup analysis, nodule diameter was an independent predictor for the interval growth of both pure GGNs (p < 0.001), and part-solid GGNs (p = 0.037). For part-solid GGNs, lung cancer history (p = 0.002) was another significant predictor of the interval growth. Interval growth of pure GGNs ≥10 mm and part-solid GGNs ≥8 mm were significantly more frequent than in pure GGNs <10 mm (p < 0.001) and part-solid GGNs <8 mm (p = 0.003), respectively. CONCLUSION: The natural course of SSNs with solid portions ≤5 mm differed significantly according to their nodule type and nodule diameters, with which their management can be subdivided. KEY POINTS: • Pure GGNs ≥10 mm have significantly more frequent interval growth than those <10 mm. • Part-solid GGNs ≥8 mm have significantly more frequent interval growth than those <8 mm. • Management of SSNs with solid portions ≤5 mm can be subdivided by diameter.


Assuntos
Adenocarcinoma in Situ/diagnóstico por imagem , Adenocarcinoma/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulo Pulmonar Solitário/diagnóstico por imagem , Adenocarcinoma/patologia , Adenocarcinoma in Situ/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Progressão da Doença , Feminino , Humanos , Estimativa de Kaplan-Meier , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Nódulos Pulmonares Múltiplos/patologia , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Nódulo Pulmonar Solitário/patologia , Tomografia Computadorizada por Raios X , Carga Tumoral , Adulto Jovem
11.
Magn Reson Imaging ; 33(7): 877-85, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25936684

RESUMO

PURPOSE: The aim of this study was to evaluate the effect of hyperpolarized (129)Xe dose on image signal-to-noise ratio (SNR) and ventilation defect conspicuity on both multi-slice gradient echo and isotropic 3D-radially acquired ventilation MRI. MATERIALS AND METHODS: Ten non-smoking older subjects (ages 60.8±7.9years) underwent hyperpolarized (HP) (129)Xe ventilation MRI using both GRE and 3D-radial acquisitions, each tested using a 71ml (high) and 24ml (low) dose equivalent (DE) of fully polarized, fully enriched (129)Xe. For all images SNR and ventilation defect percentage (VDP) were calculated. RESULTS: Normalized SNR (SNRn), obtained by dividing SNR by voxel volume and dose was higher for high-DE GRE acquisitions (SNRn=1.9±0.8ml(-2)) than low-DE GRE scans (SNRn=0.8±0.2ml(-2)). Radially acquired images exhibited a more consistent, albeit lower SNRn (High-DE: SNRn=0.5±0.1ml(-2), low-DE: SNRn=0.5±0.2ml(-2)). VDP was indistinguishable across all scans. CONCLUSIONS: These results suggest that images acquired using the high-DE GRE sequence provided the highest SNRn, which was in agreement with previous reports in the literature. 3D-radial images had lower SNRn, but have advantages for visual display, monitoring magnetization dynamics, and visualizing physiological gradients. By evaluating normalized SNR in the context of dose-equivalent formalism, it should be possible to predict (129)Xe dose requirements and quantify the benefits of more efficient transmit/receive coils, field strengths, and pulse sequences.


Assuntos
Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ventilação Pulmonar , Transtornos Respiratórios/diagnóstico por imagem , Processamento de Sinais Assistido por Computador , Isótopos de Xenônio/administração & dosagem , Administração por Inalação , Algoritmos , Meios de Contraste/administração & dosagem , Relação Dose-Resposta a Droga , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído , Ultrassonografia
12.
J Appl Physiol (1985) ; 115(6): 850-60, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23845983

RESUMO

Although some central aspects of pulmonary function (ventilation and perfusion) are known to be heterogeneous, the distribution of diffusive gas exchange remains poorly characterized. A solution is offered by hyperpolarized 129Xe magnetic resonance (MR) imaging, because this gas can be separately detected in the lung's air spaces and dissolved in its tissues. Early dissolved-phase 129Xe images exhibited intensity gradients that favored the dependent lung. To quantitatively corroborate this finding, we developed an interleaved, three-dimensional radial sequence to image the gaseous and dissolved 129Xe distributions in the same breath. These images were normalized and divided to calculate "129Xe gas-transfer" maps. We hypothesized that, for healthy volunteers, 129Xe gas-transfer maps would retain the previously observed posture-dependent gradients. This was tested in nine subjects: when the subjects were supine, 129Xe gas transfer exhibited a posterior-anterior gradient of -2.00 ± 0.74%/cm; when the subjects were prone, the gradient reversed to 1.94 ± 1.14%/cm (P < 0.001). The 129Xe gas-transfer maps also exhibited significant heterogeneity, as measured by the coefficient of variation, that correlated with subject total lung capacity (r = 0.77, P = 0.015). Gas-transfer intensity varied nonmonotonically with slice position and increased in slices proximal to the main pulmonary arteries. Despite substantial heterogeneity, the mean gas transfer for all subjects was 1.00 ± 0.01 while supine and 1.01 ± 0.01 while prone (P = 0.25), indicating good "matching" between gas- and dissolved-phase distributions. This study demonstrates that single-breath gas- and dissolved-phase 129Xe MR imaging yields 129Xe gas-transfer maps that are sensitive to altered gas exchange caused by differences in lung inflation and posture.


Assuntos
Imageamento por Ressonância Magnética/métodos , Troca Gasosa Pulmonar/fisiologia , Isótopos de Xenônio , Adulto , Idoso , Feminino , Voluntários Saudáveis , Humanos , Imageamento Tridimensional , Pulmão/fisiologia , Masculino , Pessoa de Meia-Idade , Decúbito Ventral/fisiologia , Decúbito Dorsal/fisiologia , Adulto Jovem
13.
Chest ; 144(4): 1300-1310, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23722696

RESUMO

BACKGROUND: Fluorine-enhanced MRI is a relatively inexpensive and straightforward technique that facilitates regional assessments of pulmonary ventilation. In this report, we assess its suitability through the use of perfluoropropane (PFP) in a cohort of human subjects with normal lungs and subjects with lung disease. METHODS: Twenty-eight subjects between the ages of 18 and 71 years were recruited for imaging and were classified based on spirometry findings and medical history. Imaging was carried out on a Siemens TIM Trio 3T MRI scanner using two-dimensional, gradient echo, fast low-angle shot and three-dimensional gradient echo, volumetric, interpolated, breath-hold examination sequences for proton localizers and PFP functional scans, respectively. Respiratory waveforms and physiologic signals of interest were monitored throughout the imaging sessions. A region-growing algorithm was applied to the proton localizers to define the lung field of view for analysis of the PFP scans. RESULTS: All subjects tolerated the gas mixture well with no adverse side effects. Images of healthy lungs demonstrated a homogeneous distribution of the gas with sufficient signal-to-noise ratios, while lung images from asthmatic and emphysematous lungs demonstrated increased heterogeneity and ventilation defects. CONCLUSIONS: Fluorine-enhanced MRI using a normoxic PFP gas mixture is a well-tolerated, radiation-free technique for regionally assessing pulmonary ventilation. The inherent physical characteristics and applicability of the gaseous agent within a magnetic resonance setting facilitated a clear differentiation between normal and diseased lungs.


Assuntos
Meios de Contraste , Fluorocarbonos , Pneumopatias/diagnóstico , Imageamento por Ressonância Magnética , Adolescente , Adulto , Idoso , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
14.
Clin Imaging ; 36(5): 515-21, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22920355

RESUMO

The purpose of this study was to investigate gray-scale inversion in nodule detection on chest radiography. Simulated nodules were superimposed randomly onto normal chest radiographs. Six radiologists interpreted 144 chest radiographs during three reading sessions: traditional presentation, inverted gray-scale, and a choice session allowing use of traditional and gray-scale inverted views. Sensitivity and specificity were used to assess accuracy based on presence or absence of a nodule. Gray-scale inversion and choice display sessions resulted in significantly higher nodule detection specificity and decreased sensitivity compared to traditional display. Gray-scale inversion may decrease false-positive nodule findings during chest X-ray interpretation.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Radiografia Torácica/métodos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Competência Clínica , Diagnóstico Diferencial , Humanos , Neoplasias Pulmonares/patologia , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade , Nódulo Pulmonar Solitário/patologia
15.
J Digit Imaging ; 25(4): 520-6, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22349990

RESUMO

Under typical dark chest radiography reading room conditions, a radiologist's pupils contract and dilate as their visual focus intermittently shifts between the high luminance monitor and the darker background wall, resulting in increased visual fatigue and degradation of diagnostic performance. A controlled increase of ambient lighting may minimize these visual adjustments and potentially improve comfort and accuracy. This study was designed to determine the effect of a controlled increase of ambient lighting on chest radiologist nodule detection performance. Four chest radiologists read 100 radiographs (50 normal and 50 containing a subtle nodule) under low (E=1 lx) and elevated (E=50 lx) ambient lighting levels on a DICOM-calibrated, medical-grade liquid crystal display. Radiologists were asked to identify nodule locations and rate their detection confidence. A receiver operating characteristic (ROC) analysis of radiologist results was performed and area under ROC curve (AUC) values calculated for each ambient lighting level. Additionally, radiologist selection times under both illuminance conditions were determined. Average AUC values did not significantly differ (p>0.05) between ambient lighting levels (estimated mean difference=-0.03; 95% CI, (-0.08, 0.03)). Average selection times decreased or remained constant with increased illuminance. The most considerable decreases occurred for false positive identification times (35.4±18.8 to 26.2±14.9 s) and true positive identification times (29.7±18.3 to 24.5±15.5 s). No performance differences were statistically significant. Study findings suggest that a controlled increase of ambient lighting within darkly lit chest radiology reading rooms, to a level more suitable for performance of common radiological tasks, does not appear to have a statistically significant effect on nodule detection performance.


Assuntos
Apresentação de Dados , Iluminação/métodos , Neoplasias Pulmonares/diagnóstico , Pulmão/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Percepção Visual , Área Sob a Curva , Humanos , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
J Digit Imaging ; 25(1): 137-47, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21618054

RESUMO

The objective of this study was to implement and evaluate the performance of a biplane correlation imaging (BCI) technique aimed to reduce the effect of anatomic noise and improve the detection of lung nodules in chest radiographs. Seventy-one low-dose posterior-anterior images were acquired from an anthropomorphic chest phantom with 0.28° angular separations over a range of ±10° along the vertical axis within an 11 s interval. Similar data were acquired from 19 human subjects with institutional review board approval and informed consent. The data were incorporated into a computer-aided detection (CAD) algorithm in which suspect lesions were identified by examining the geometrical correlation of the detected signals that remained relatively constant against variable anatomic backgrounds. The data were analyzed to determine the effect of angular separation, and the overall sensitivity and false-positives for lung nodule detection. The best performance was achieved for angular separations of the projection pairs greater than 5°. Within that range, the technique provided an order of magnitude decrease in the number of false-positive reports when compared with CAD analysis of single-view images. Overall, the technique yielded ~1.1 false-positive per patient with an average sensitivity of 75%. The results indicated that the incorporation of angular information can offer a reduction in the number of false-positives without a notable reduction in sensitivity. The findings suggest that the BCI technique has the potential for clinical implementation as a cost-effective technique to improve the detection of subtle lung nodules with lowered rate of false-positives.


Assuntos
Algoritmos , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Adulto , Idoso , Artefatos , Reações Falso-Positivas , Estudos de Viabilidade , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Pessoa de Meia-Idade , Reconhecimento Automatizado de Padrão/métodos , Curva ROC , Estudos de Amostragem
17.
Magn Reson Med ; 65(4): 1154-65, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21413080

RESUMO

Given its greater availability and lower cost, (129) Xe apparent diffusion coefficient (ADC) MRI offers an alternative to (3) He ADC MRI. To demonstrate the feasibility of hyperpolarized (129) Xe ADC MRI, we present results from healthy volunteers (HV), chronic obstructive pulmonary disease (COPD) subjects, and age-matched healthy controls (AMC). The mean parenchymal ADC was 0.036 ± 0.003 cm(2) sec(-1) for HV, 0.043 ± 0.006 cm(2) sec(-1) for AMC, and 0.056 ± 0.008 cm(2) sec(-1) for COPD subjects with emphysema. In healthy individuals, but not the COPD group, ADC decreased significantly in the anterior-posterior direction by ∼ 22% (P = 0.006, AMC; 0.0059, HV), likely because of gravity-induced tissue compression. The COPD group exhibited a significantly larger superior-inferior ADC reduction (∼ 28%) than the healthy groups (∼ 24%) (P = 0.00018, HV; P = 3.45 × 10(-5) , AMC), consistent with smoking-related tissue destruction in the superior lung. Superior-inferior gradients in healthy subjects may result from regional differences in xenon concentration. ADC was significantly correlated with pulmonary function tests (forced expiratory volume in 1 sec, r = -0.77, P = 0.0002; forced expiratory volume in 1 sec/forced vital capacity, r = -0.77, P = 0.0002; diffusing capacity of carbon monoxide in the lung/alveolar volume (V(A) ), r = -0.77, P = 0.0002). In healthy groups, ADC increased with age by 0.0002 cm(2) sec(-1) year(-1) (r = 0.56, P = 0.02). This study shows that (129) Xe ADC MRI is clinically feasible, sufficiently sensitive to distinguish HV from subjects with emphysema, and detects age- and posture-dependent changes.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Compostos Radiofarmacêuticos , Isótopos de Xenônio , Administração por Inalação , Adulto , Idoso , Meios de Contraste/administração & dosagem , Feminino , Humanos , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/administração & dosagem , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Isótopos de Xenônio/administração & dosagem
18.
PLoS One ; 5(8): e12192, 2010 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-20808950

RESUMO

BACKGROUND: One of the central physiological functions of the lungs is to transfer inhaled gases from the alveoli to pulmonary capillary blood. However, current measures of alveolar gas uptake provide only global information and thus lack the sensitivity and specificity needed to account for regional variations in gas exchange. METHODS AND PRINCIPAL FINDINGS: Here we exploit the solubility, high magnetic resonance (MR) signal intensity, and large chemical shift of hyperpolarized (HP) (129)Xe to probe the regional uptake of alveolar gases by directly imaging HP (129)Xe dissolved in the gas exchange tissues and pulmonary capillary blood of human subjects. The resulting single breath-hold, three-dimensional MR images are optimized using millisecond repetition times and high flip angle radio-frequency pulses, because the dissolved HP (129)Xe magnetization is rapidly replenished by diffusive exchange with alveolar (129)Xe. The dissolved HP (129)Xe MR images display significant, directional heterogeneity, with increased signal intensity observed from the gravity-dependent portions of the lungs. CONCLUSIONS: The features observed in dissolved-phase (129)Xe MR images are consistent with gravity-dependent lung deformation, which produces increased ventilation, reduced alveolar size (i.e., higher surface-to-volume ratios), higher tissue densities, and increased perfusion in the dependent portions of the lungs. Thus, these results suggest that dissolved HP (129)Xe imaging reports on pulmonary function at a fundamental level.


Assuntos
Imageamento por Ressonância Magnética/métodos , Alvéolos Pulmonares/fisiologia , Troca Gasosa Pulmonar , Adulto , Artefatos , Volume Sanguíneo , Estudos de Viabilidade , Humanos , Imageamento Tridimensional , Pessoa de Meia-Idade , Respiração , Fatores de Tempo , Isótopos de Xenônio , Adulto Jovem
19.
Radiographics ; 29(3): 839-59, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19448119

RESUMO

The sternum and sternoclavicular joints--critical structures of the anterior chest wall--may be affected by various anatomic anomalies and pathologic processes, some of which require treatment. Pectus excavatum and pectus carinatum are common congenital anomalies that are usually benign but may warrant surgical treatment if they cause compression of vital internal structures. By contrast, developmental variants such as the sternal foramen are asymptomatic and do not require further evaluation or treatment. Arthritides of the sternoclavicular joint (osteoarthritis, septic arthritis, and seronegative arthropathies) are common and must be differentiated before an appropriate management method can be selected. The recognition of complications of sternotomy (eg, sternal dehiscence, secondary osteomyelitis) is critical to avoid life-threatening sequelae such as acute mediastinitis. Likewise, the detection of sternal fractures and sternoclavicular dislocations is important, especially where they impinge on vital structures. In addition, sternal malignancies (most commonly, metastases and chondrosarcoma) must be distinguished from benign neoplasms. To achieve accurate and timely diagnoses that facilitate appropriate treatment, radiologists must be familiar with the appearances of these normal anatomic variants and diseases of the sternum.


Assuntos
Articulação Esternoclavicular/diagnóstico por imagem , Esterno/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Idoso , Artrite/diagnóstico por imagem , Neoplasias Ósseas/diagnóstico por imagem , Feminino , Fraturas Ósseas/diagnóstico por imagem , Tórax em Funil/diagnóstico por imagem , Humanos , Luxações Articulares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Osteomielite/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Articulação Esternoclavicular/lesões , Articulação Esternoclavicular/cirurgia , Esterno/anormalidades , Esterno/lesões , Esterno/cirurgia , Adulto Jovem
20.
IEEE Trans Nucl Sci ; 56(1): 36-45, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29375155

RESUMO

Overlapping anatomical structures may confound the detection of abnormal pathology, including lung nodules, in conventional single-projection chest radiography. To minimize this fundamental limiting factor, a dedicated digital multi-projection system for chest imaging was recently developed at the Radiology Department of Duke University. We are reporting the design of the multi-projection imaging system and its initial performance in an ongoing clinical trial. The system is capable of acquiring multiple full-field projections of the same patient along both the horizontal and vertical axes at variable speeds and acquisition frame rates. These images acquired in rapid succession from slightly different angles about the posterior-anterior (PA) orientation can be correlated to minimize the influence of overlying anatomy. The developed system has been tested for repeatability and motion blur artifacts to investigate its robustness for clinical trials. Excellent geometrical consistency was found in the tube motion, with positional errors for clinical settings within 1%. The effect of tube-motion on the image quality measured in terms of impact on the Modulation Transfer Function (MTF) was found to be minimal. The system was deemed clinic-ready and a clinical trial was subsequently launched. The flexibility of image acquisition built into the system provides a unique opportunity to easily modify it for different clinical applications, including tomosynthesis, correlation imaging (CI), and stereoscopic imaging.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA