Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Int J Med Robot ; 17(5): e2293, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34080270

RESUMO

BACKGROUND: Many centres deny obese patients with a body mass index (BMI) >35 access to kidney transplantation due to increased intraoperative and postoperative complications. METHODS: From August 2017 to December 2019, 73 consecutive cases of kidney transplantation in morbidly obese patients were enrolled at a single university at the initiation of a robotic transplant surgery program. Outcomes of patients who underwent robotic assisted kidney transplant (RAKT) were compared to frequency-matched patients undergoing open kidney transplant (OKT). RESULTS: A total of 24 morbidly obese patients successfully underwent RAKT, and 49 obese patients received an OKT. The RAKT group developed fewer surgical site infections (SSI) than the OKT group. Graft function, creatinine, and glomerular filtration rate (GFR) were similar between groups 1 year after surgery. Graft and patient survival were 100% for both groups. CONCLUSIONS: RAKT offers a safe alternative for morbidly obese patients, who may otherwise be denied access to OKT.


Assuntos
Falência Renal Crônica , Transplante de Rim , Obesidade Mórbida , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Falência Renal Crônica/complicações , Falência Renal Crônica/cirurgia , Obesidade Mórbida/complicações , Obesidade Mórbida/cirurgia , Duração da Cirurgia , Resultado do Tratamento
2.
J Oncol ; 2012: 146943, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22956950

RESUMO

A pilot study is underway to quantify in vivo the uptake and distribution of Tc-99m Sestamibi in subjects without previous history of breast cancer using a dedicated SPECT-CT breast imaging system. Subjects undergoing diagnostic parathyroid imaging studies were consented and imaged as part of this IRB-approved breast imaging study. For each of the seven subjects, one randomly selected breast was imaged prone-pendant using the dedicated, compact breast SPECT-CT system underneath the shielded patient support. Iteratively reconstructed and attenuation and/or scatter corrected images were coregistered; CT images were segmented into glandular and fatty tissue by three different methods; the average concentration of Sestamibi was determined from the SPECT data using the CT-based segmentation and previously established quantification techniques. Very minor differences between the segmentation methods were observed, and the results indicate an average image-based in vivo Sestamibi concentration of 0.10 ± 0.16 µCi/mL with no preferential uptake by glandular or fatty tissues.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA