1.
Arthroscopy ; 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38925233

RESUMO

PURPOSE: To investigate the effectiveness of bursal acromial resurfacing (acromiograft) on acromiohumeral distance, subacromial contact area, and pressure in a cadaveric model of massive rotator cuff tear. METHODS: Eight fresh-frozen cadaveric shoulders were tested using a customized shoulder testing system. Humeral head translation, subacromial contact pressure, and the subacromial contact area were evaluated across four conditions: (1) intact shoulder; (2) simulated massive rotator cuff tear; (3) 3-mm acromiograft condition; (4) 6-mm acromiograft condition. The acromiografts were simulated using Teflon and a reported technique. The values were measured at 0°, 20°, and 40° abduction and 0°, 30°, 60°, and 90° external rotation (ER) for each abduction status. RESULTS: Compared with a massive cuff tear, the 6-mm acromiograft significantly reduced the superior translation of the humeral head at all abduction/ER angles (P<0.05). The 3-mm acromiograft also decreased superior translation of the humeral head compared to massive cuff tear, but not all differences were significant. The 3- and 6-mm acromiografts significantly decreased the subacromial contact pressure and increased the subacromial contact area in almost all positions (P<0.05). The 3-mm acromiograft maintained biomechanical properties similar to the intact condition, whereas the 6-mm acromiograft increased the contact area. CONCLUSIONS: This biomechanical study demonstrated that both 3- and 6- mm acromiografts using Teflon in a cadaveric model of a massive cuff tear resulted in recentering of the superiorly migrated humeral head, increased the subacromial contact area, and decreased the subacromial contact pressure. The 3- mm graft was sufficient for achieving the intended therapeutic effects. CLINICAL RELEVANCE: The acromiograft can normalize altered biomechanics and may aid the treatment of massive cuff tears. As grafting the acromion's undersurface is new with limited clinical outcomes, further observation is crucial. Using Teflon instead of ADM allograft for bursal acromial resurfacing could yield different results, requiring careful interpretation.

2.
Am J Sports Med ; 52(6): 1419-1427, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38544363

RESUMO

BACKGROUND: Superior capsular reconstruction (SCR) and lower trapezius tendon transfer (LTT) have recently been used to manage irreparable posterosuperior rotator cuff tears (PSRCTs). There has been a paucity of comparative biomechanical considerations between the 2 procedures. PURPOSE: To compare the glenohumeral stability and biomechanical properties between SCR and LTT in PSRCTs involving the entire infraspinatus tendon region. STUDY DESIGN: Controlled laboratory study. METHODS: Eight fresh-frozen cadaveric shoulders were tested at 0°, 20°, and 40° of shoulder abduction. Maximum internal, external, and total humeral range of motion (ROM), superior translation of the humeral head, and subacromial contact characteristics were compared among 4 conditions: (1) intact rotator cuff, (2) PSRCTs involving the entire infraspinatus tendon region, (3) LTT using Achilles allograft (12 N and 24 N of loading), and (4) SCR using fascia lata allograft. RESULTS: Although a decrease in total ROM was noted in LTT with 12 N compared with the tear condition, LTT with both 12 N and 24 N as well as SCR did not restrict total rotational ROM compared with the intact condition. LTT had decreased total ROM compared with tear condition at 20° of abduction (P = .042), while no significant decrease was confirmed at all abduction angles after SCR. SCR and LTT with 24 N decreased superior translation compared with the PSRCT condition at 0° and 20° of abduction (P < .037) but not significantly at 40° of abduction, whereas LTT with a 24-N load decreased glenohumeral superior translation at all abduction angles (P < .039). Both SCR and LTT decreased subacromial contact pressure compared with the tear condition (P < .014) at all abduction angles. SCR decreased subacromial contact pressure at 0° and 40° of abduction (P = .019 and P = .048, respectively) compared with LTT with 12 N of loading, while there was no difference between SCR and LTT with 24 N of loading in all abduction angles. SCR increased the contact area compared with the PSRCT condition at all abduction angles (P < .023), whereas LTT did not increase the contact area. CONCLUSION: SCR and LTT decreased glenohumeral superior translation and contact pressure compared with PSRCT conditions. The LTT was superior to SCR in terms of superior translation of the humeral head at a higher shoulder abduction angle, whereas the SCR showed more advantageous subacromial contact characteristics compared with LTT. CLINICAL RELEVANCE: These biomechanical findings provide insights into these 2 fundamentally different procedures for the treatment of young and active patients with PSRCTs involving the entire infraspinatus tendon region.


Assuntos
Cadáver , Amplitude de Movimento Articular , Lesões do Manguito Rotador , Articulação do Ombro , Transferência Tendinosa , Humanos , Transferência Tendinosa/métodos , Lesões do Manguito Rotador/cirurgia , Fenômenos Biomecânicos , Pessoa de Meia-Idade , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Articulação do Ombro/fisiologia , Idoso , Masculino , Feminino , Músculos Superficiais do Dorso/transplante , Manguito Rotador/cirurgia , Fascia Lata/transplante , Procedimentos de Cirurgia Plástica/métodos
3.
J Shoulder Elbow Surg ; 33(8): 1762-1770, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38242527

RESUMO

BACKGROUND: The utilization of short humeral stems in reverse total shoulder arthroplasty has gained attention in recent times. However, concerns regarding the risk of misalignment during implant insertion are associated with their use. METHODS: Eight fresh-frozen cadaveric shoulders were prepared for dissection and biomechanical testing. A bespoke humeral implant was fabricated to facilitate assessment of neutral, varus, and valgus alignments using a single stem, and 10° was established as the maximum permissible angle for misalignments. Shift in humerus position and changes in deltoid length attributable to misalignments relative to the neutral position were evaluated using a Microscribe 3DLx system. The impingement-free range of motion, encompassing abduction, adduction, internal rotation, and external rotation (ER), was gauged using a digital goniometer. The capacity for abduction was evaluated at maximal abduction angles under successive loading on the middle deltoid. A specialized traction system coupled with a force transducer was employed to measure anterior dislocation forces. RESULTS: Relative to the neutral alignment, valgus alignment resulted in a more distal (10.5 ± 2.4 mm) and medial (8.3 ± 2.2 mm) translation of the humeral component, whereas the varus alignment resulted in the humerus shifting more superiorly (11.2 ± 1.3 mm) and laterally (9.9 ± 0.9 mm) at 0° abduction. The valgus alignment exhibited the highest abduction angle than neutral alignment (86.2°, P < .001). Conversely, the varus alignment demonstrated significantly higher adduction (18.4 ± 7.4°, P < .001), internal rotation (68.9 ± 15.0°, P = .014), and ER (45.2 ± 10.5°, P = .002) at 0° abduction compared to the neutral alignments. Anterior dislocation forces were considerably lower (23.8 N) in the varus group compared to the neutral group at 0°ER (P = .047). Additionally, abduction capability was markedly higher in varus alignment at low deltoid loads than the neutral alignment (5N, P = .009; 7.5 N, P = .007). CONCLUSIONS: The varus position enhances rotational range of motion (ROM) but increases instability, while the valgus position does not significantly impact ROM or instability compared to the neutral position.


Assuntos
Artroplastia do Ombro , Cadáver , Úmero , Amplitude de Movimento Articular , Articulação do Ombro , Prótese de Ombro , Humanos , Artroplastia do Ombro/métodos , Úmero/cirurgia , Idoso , Articulação do Ombro/cirurgia , Masculino , Feminino , Desenho de Prótese , Fenômenos Biomecânicos , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais
4.
Hand Surg Rehabil ; 43(2): 101643, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38228245

RESUMO

This study investigated whether dorsoradial ligament repair with internal brace augmentation provided more immediate stability in the trapeziometacarpal joint than dorsoradial ligament repair alone. Seven matched pairs of cadaveric hands were used. One specimen from each pair was assigned to the repair-only group and the other to the repair + internal brace augmentation group. Trapeziometacarpal joint range of motion and translation were quantified under different conditions for both groups: (1) intact, (2) transected dorsoradial ligament, and (3) repaired dorsoradial ligament or repaired dorsoradial ligament plus internal brace augmentation. Load-to-failure tests were performed after repair. Range of motion and translation were increased by dorsoradial ligament transection and were decreased by dorsoradial ligament repair; however, compared to the intact condition, the repair-only group demonstrated greater flexion/extension range, while the repair + internal brace group showed no significant difference in range of motion. Mean loads at 2- and 3-mm displacements were greater in the repair + internal brace group than in the repair-only group (18.0 ± 1.8 N vs. 10.8 ± 1.3 N for 2 mm displacement and 35.3 ± 3.7 N vs. 23.1 ± 2.9 N for 3 mm displacement, respectively). Internal brace augmentation improved the load-to-failure characteristics of dorsoradial ligament repair without compromising range of motion. LEVEL OF EVIDENCE: IV.


Assuntos
Braquetes , Cadáver , Articulações Carpometacarpais , Ligamentos Articulares , Amplitude de Movimento Articular , Humanos , Ligamentos Articulares/cirurgia , Amplitude de Movimento Articular/fisiologia , Fenômenos Biomecânicos , Articulações Carpometacarpais/cirurgia , Articulações Carpometacarpais/fisiopatologia , Feminino , Masculino , Pessoa de Meia-Idade , Idoso
5.
J Shoulder Elbow Surg ; 33(4): 757-764, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37871791

RESUMO

BACKGROUND: The treatment of shoulder instability in patients with subcritical glenoid bone loss poses a difficult problem for surgeons as new evidence supports a higher failure rate when a standard arthroscopic Bankart repair is used. The purpose of this study was to compare a conjoint tendon transfer (soft-tissue Bristow) to an open Bankart repair in a cadaveric instability model of 10% glenoid bone loss. METHODS: Eight cadaveric shoulders were tested using a custom testing system that allows for a 6-degree-of-freedom positioning of the glenohumeral joint. The rotator cuff muscles were loaded to simulate physiologic muscle conditions. Four conditions were tested: (1) intact, (2) Bankart lesion with 10% bone loss, (3) conjoint tendon transfer, and (4) open Bankart repair. Range of motion, glenohumeral kinematics, and anterior-inferior translation at 60° of external rotation with 20 N, 30 N, and 40 N were measured in the scapular and coronal planes. Glenohumeral joint translational stiffness was calculated as the linear fit of the translational force-displacement curve. Force to anterior-inferior dislocation was also measured in the coronal plane. Repeated measures analysis of variance with a Bonferroni correction was used for statistical analysis. RESULTS: A Bankart lesion with 10% bone loss increased the range of motion in both the scapular (P = .001) and coronal planes (P = .001). The conjoint tendon transfer had a minimal effect on the range of motion (vs. intact P = .019, .002), but the Bankart repair decreased the range of motion to intact (P = .9, .4). There was a significant decrease in glenohumeral joint translational stiffness for the Bankart lesion compared with intact in the coronal plane (P = .021). The conjoint tendon transfer significantly increased stiffness in the scapular plane (P = .034), and the Bankart repair increased stiffness in the coronal plane (P = .037) compared with the Bankart lesion. The conjoint tendon transfer shifted the humeral head posteriorly at 60° and 90° of external rotation in the scapular plane. The Bankart repair shifted the head posteriorly in maximum external rotation in the coronal plane. There was no significant difference in force to dislocation between the Bankart repair (75.8 ± 6.6 N) and the conjoint tendon transfer (66.5 ± 4.4 N) (P = .151). CONCLUSION: In the setting of subcritical bone loss, both the open Bankart repair and conjoint tendon transfer are biomechanically viable options for the treatment of anterior shoulder instability; further studies are needed to extrapolate these data to the clinical setting.


Assuntos
Lesões de Bankart , Doenças Ósseas Metabólicas , Luxações Articulares , Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Humanos , Articulação do Ombro/cirurgia , Articulação do Ombro/patologia , Transferência Tendinosa , Ombro/patologia , Instabilidade Articular/cirurgia , Lesões de Bankart/patologia , Luxação do Ombro/cirurgia , Fenômenos Biomecânicos , Amplitude de Movimento Articular/fisiologia , Cadáver
6.
J Shoulder Elbow Surg ; 33(6): 1366-1376, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38104718

RESUMO

BACKGROUND: Middle trapezius tendon (MTT) transfer has been suggested for promising treatment of irreparable isolated supraspinatus tendon tears (IISTTs). However, there have been no attempts to assess the biomechanical efficacy of MTT transfer. This study aims to evaluate the biomechanical efficacy of MTT transfer in the setting of IISTTs. METHODS: Eight fresh frozen cadaveric shoulders were tested in 3 conditions: (1) intact rotator cuff, (2) IISTT, and (3) MTT transfer using Achilles allograft for IISTTs. Total humeral rotational range of motion (ROM), superior translation of the humeral head, and subacromial contact characteristics were measured at 0°, 20°, and 40° glenohumeral abduction (representing 0°, 30°, and 60° shoulder abduction). Superior translation and subacromial contact pressures were measured at 0°, 30°, 60°, and 90° external rotation (ER). Two different MTT muscle loading conditions were investigated. A linear mixed effects model and Tukey post hoc test were used for statistical analysis. RESULTS: Total ROM was significantly increased after IISTT at 20° abduction (P = .037). There were no changes in total ROM following MTT transfer compared to the IISTT condition (P > .625 for all comparisons). The IISTT condition significantly increased superior translation compared to the intact rotator cuff condition in 0° and 20° abduction with all ER angles (P < .001), 40° abduction-30° ER (P = .016), and 40° abduction-60° ER (P = .002). MTT transfer significantly decreased superior translation of the humeral head at all abduction angles compared to the IISTT condition (P < .026). MTT transfer significantly decreased peak contact pressure by 638.7 kPa (normal loading) and 726.8 kPa (double loading) at 0° abduction-30° ER compared to the IISTT condition (P < .001). Mean contact pressure was decreased by 102.8 kPa (normal loading) and 118.0 kPa (double loading) at 0° abduction-30° ER (P < .001) and 101.0 kPa (normal loading) and 99.2 kPa (double loading) at 0° abduction-60° ER (P < .001). MTT transfer at 20° abduction-30° ER with 24 N loading significantly decreased contact pressure by 91.2 kPa (P = .035). CONCLUSIONS: The MTT transfer biomechanically restored the superior humeral head translation and reduced the subacromial contact pressure in a cadaveric model of IISTT, while not restricting total ROM. These findings suggest that MTT transfer may have potential as a surgical treatment for IISTTs.


Assuntos
Tendão do Calcâneo , Cadáver , Cabeça do Úmero , Amplitude de Movimento Articular , Lesões do Manguito Rotador , Transferência Tendinosa , Humanos , Transferência Tendinosa/métodos , Lesões do Manguito Rotador/cirurgia , Cabeça do Úmero/cirurgia , Fenômenos Biomecânicos , Masculino , Idoso , Tendão do Calcâneo/cirurgia , Tendão do Calcâneo/lesões , Feminino , Aloenxertos , Pessoa de Meia-Idade , Articulação do Ombro/cirurgia , Músculos Superficiais do Dorso/transplante , Instabilidade Articular , Manguito Rotador/cirurgia
7.
Clin Orthop Surg ; 15(4): 616-626, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37529193

RESUMO

Background: Disruption of the rotator cuff muscles compromises concavity compression force, which leads to superior migration of the humeral head and loss of stability. A novel idea of using the magnetic force to achieve shoulder stabilization in massive rotator cuff tears (MRCTs) was considered because the magnets can stabilize two separate entities with an attraction force. This study aimed to investigate the biomechanical effect of the magnetic force on shoulder stabilization in MRCTs. Methods: Seven fresh frozen cadaveric specimens were used with a customized shoulder testing system. Three testing conditions were set up: condition 1, intact rotator cuff without magnets; condition 2, an MRCT without magnets; condition 3, an MRCT with magnets. For each condition, anterior-posterior translation, superior translation, superior migration, and subacromial contact pressure were measured at 0°, 30°, and 60° of abduction. The abduction capability of condition 2 was compared with that of condition 3. Results: The anterior-posterior and superior translations increased in condition 2; however, they decreased compared to condition 2 when the magnets were applied (condition 3) in multiple test positions and loadings (p < 0.05). Abduction capability improved significantly in condition 3 compared with that in condition 2, even for less deltoid loading (p < 0.05). Conclusions: The magnet biomechanically played a positive role in stabilizing the shoulder joint and enabled abduction with less deltoid force in MRCTs. However, to ensure that the magnet is clinically applicable as a stabilizer for the shoulder joint, it is necessary to thoroughly verify its safety in the human body and to conduct further research on technical challenges.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Humanos , Lesões do Manguito Rotador/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiologia , Imãs , Fenômenos Biomecânicos , Cadáver , Amplitude de Movimento Articular/fisiologia
8.
Clin Orthop Surg ; 15(3): 508-515, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37274497

RESUMO

Background: The purpose of this study was to quantify and compare the biomechanical characteristics of a new locking loop stitch (LLS), developed utilizing the concepts of both running locking stitch and needleless stitch, to the traditional Krackow stitch. Methods: The Krackow stitch with No.2 braided suture and the LLS with 1.3-mm augmented polyblend suture tape were compared biomechanically. The LLS was performed with single strand locking loops and wrapping suture around the tendon, resulting in half the needle penetrations through the graft compared to the Krackow stitch. Twenty bovine extensor tendons were divided randomly into two groups. The tendons were prepared to match equal thickness and cross-sectional area. Each suture-tendon was stitched and preloaded to 5 N for 60 seconds, cyclically loaded to 20 N, 40 N, and 60 N for 10 cycles each, and then loaded to failure. The deformation of the suture-tendon construct, stiffness, yield load, and ultimate load were measured. Results: The LLS had significantly less deformation of the suture-tendon construct at 100 N, 200 N, 300 N, and at ultimate load compared to the Krackow stitch (Krackow stitch and LLS at 100 N: 1.3 ± 0.1 mm and 1.0 ± 0.2 mm, p < 0.001; 200 N: 3.0 ± 0.3 mm and 1.9 ± 0.2 mm, p < 0.001; 300 N: 5.1 ± 0.6 mm and 2.9 ± 0.4 mm, p < 0.001; ultimate load: 12.8 ± 2.8 mm and 5.0 ± 1.2 mm, p < 0.001). The LLS had significantly greater stiffness (Krackow stitch and LLS: 97.5 ± 6.9 N/mm and 117.2 ± 13.9 N/mm, p < 0.001) and yield load (Krackow stitch and LLS: 66.2 ± 15.9 N and 237.9 ± 93.6 N, p < 0.001) compared to the Krackow stitch. There was no significant difference in ultimate load (Krackow stitch: 450.2 ± 49.4 N; LLS: 472.6 ± 59.8 N; p = 0.290). Conclusions: The LLS had significantly smaller deformation of the suture-tendon construct compared to the Krackow stitch. The LLS may be a viable surgical alternative to the Krackow stitch for graft fixation when secure fixation is necessary.


Assuntos
Procedimentos Ortopédicos , Técnicas de Sutura , Animais , Bovinos , Humanos , Fenômenos Biomecânicos , Tendões/transplante , Suturas , Resistência à Tração
9.
J Shoulder Elbow Surg ; 32(8): 1662-1672, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37044302

RESUMO

BACKGROUND: The objective of our study was to quantify the biomechanical effectiveness of lateralization in RTSA with respect to glenoid and humeral component configurations. METHODS: Eight cadaveric shoulders were tested in a custom shoulder testing system. Three parameters, including the glenosphere thickness, humeral tray offset, and insert thickness, were assessed by implanting 8 configurations on each specimen. Humeral position, maximum internal rotation, and maximum external rotation (ER) before impingement were quantified at 0° and 30° glenohumeral abduction. The adduction angle at which the humeral component contacted the inferior scapular neck and the abduction angle where acromial notching occurred were also measured. The simulated active range of motion, including ER and abduction capability, was tested by increasing the load applied to the remaining posterior cuff and middle deltoid, respectively. Stability was evaluated by the forces that induced anterior dislocation at 30° abduction. RESULTS: The thicker glenosphere affected only lateralization, whereas the centric humeral tray and thicker insert significantly affected humeral lateralization and distalization simultaneously. Greater adduction and ER angles were found in more lateralized humerus. A significant positive correlation between humeral lateralization and ER capability was observed; however, lateralization did not significantly improve implant stability in this cadaveric testing system. CONCLUSION: Lateralization is achievable at both the glenoid and humeral sides but has different effects; therefore, lateralized implant options should be selected according to patients' needs. Lateralization is an effective strategy for reducing adduction notching while increasing ER capability. Thicker glenospheres only affected humeral lateralization. The centric humeral tray would be selected for less distalization to avoid overlengthening, whereas an eccentric humeral tray is the most effective for distalization and medialization in reducing abduction notching to the acromion and for patients with pseudoparalysis.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Artroplastia do Ombro/métodos , Articulação do Ombro/cirurgia , Desenho de Prótese , Amplitude de Movimento Articular , Cadáver , Úmero/cirurgia , Fenômenos Biomecânicos
10.
Arch Orthop Trauma Surg ; 143(9): 5759-5766, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37069412

RESUMO

INTRODUCTION: Limitation of active Internal Rotation (IR) following Reverse Shoulder Arthroplasty (RSA) in patients with massive Rotator Cuff Tears (mRCTs) with subscapularis insufficiency remains a challenge. Recently, RSA with Latissimus dorsi and Teres major (LDTM) transfer in patients with limited active IR has been demonstrated as a reliable treatment option. The purpose of this study was to biomechanically compare the IR torque following LDTM transfer with RSA in mRCT with subscapularis insufficiency to RSA without tendon transfer. METHODS: Eight cadaveric shoulders were tested (mean age: 64.5 ± 1.9 years) using a custom shoulder testing system that permits loading conditions of mRCT with subscapularis insufficiency. Two conditions were tested and compared. The first condition was RSA alone and the second condition was RSA with LDTM transfer. RSA with a medialized glenoid and lateralized humerus design was used for all specimens. The specimens were tested at 0°, 20° and 40° abduction at three different muscle loads: baseline, double, and triple, while the Teres minor and deltoid loads were kept constant. IR torque was measured with a torque wrench at 0°, 20°, and 40° abduction and 60° and 45° IR positions. Force required for anterior dislocation was measured at 20° abduction and 10° IR position. RESULTS: RSA with LDTM transfer had significantly higher IR torque at all abductions and muscle loading compared with RSA without transfer (average at all positions; RSA without transfer: 0.80 ± 0.02 Nm, LDTM transfer for all loads: 1.43 ± 0.10 Nm). RSA with LDTM transfer (91.4 ± 3.9 N) needed higher force for anterior dislocation compared to RSA alone (89.4 ± 4.1 N), but there was no significant difference. CONCLUSION: LDTM transfer with RSA increases IR torque compared to RSA without tendon transfer in a cadaveric model. LDTM transfer with RSA may be a reliable treatment option for patients with mRCT and subscapularis insufficiency who are expected to have limited active IR following RSA.


Assuntos
Artroplastia do Ombro , Lesões do Manguito Rotador , Articulação do Ombro , Músculos Superficiais do Dorso , Humanos , Pessoa de Meia-Idade , Idoso , Manguito Rotador/cirurgia , Articulação do Ombro/cirurgia , Transferência Tendinosa , Torque , Lesões do Manguito Rotador/cirurgia , Cadáver , Amplitude de Movimento Articular/fisiologia
11.
Am J Sports Med ; 51(3): 758-767, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36745049

RESUMO

BACKGROUND: PARP-1 (poly[ADP-ribose]) was shown to influence the inflammatory response after rotator cuff tear, leading to fibrosis, muscular atrophy, and fatty infiltration in mouse rotator cuff degeneration. So far, it is not known how PARP-1 influences enthesis healing after rotator cuff tear repair. HYPOTHESIS/PURPOSE: This study aimed to examine the feasibility of oral PARP-1 inhibition and investigate its influence on rat supraspinatus enthesis and muscle healing after rotator cuff repair. The hypothesis was that oral PARP-1 inhibition would improve enthesis healing after acute rotator cuff repair in a rat model. STUDY DESIGN: Controlled laboratory study. METHODS: In 24 Sprague-Dawley rats, the supraspinatus tendon was sharply detached and immediately repaired with a single transosseous suture. The rats were randomly allocated into 2 groups, with the rats in the inhibitor group receiving veliparib with a target dose of 12.5 mg/kg/d via drinking water during the postoperative recovery period. The animals were sacrificed 8 weeks after surgery. For the analysis, macroscopic, biomechanical, and histologic methods were used. RESULTS: Oral veliparib was safe for the rats, with no adverse effects observed. In total, the inhibitor group had a significantly better histologic grading of the enthesis with less scar tissue formation. The macroscopic cross-sectional area of the supraspinatus muscles was 10.5% higher (P = .034) in the inhibitor group, which was in agreement with an 8.7% higher microscopic muscle fiber diameter on histologic sections (P < .0001). There were no statistically significant differences in the biomechanical properties between the groups. CONCLUSION: This study is the first to investigate the influence of PARP-1 inhibition on healing enthesis. On the basis of these findings, we conclude that oral veliparib, which was previously shown to inhibit PARP-1 effectively, is safe to apply and has beneficial effects on morphologic enthesis healing and muscle fiber size. CLINICAL RELEVANCE: Modulating the inflammatory response through PARP-1 inhibition during the postoperative healing period is a promising approach to improve enthesis healing and reduce rotator cuff retearing. With substances already approved by the Food and Drug Administration, PARP-1 inhibition bears high potential for future translation into clinical application.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador , Ratos , Camundongos , Animais , Manguito Rotador/patologia , Lesões do Manguito Rotador/tratamento farmacológico , Lesões do Manguito Rotador/cirurgia , Lesões do Manguito Rotador/patologia , Cicatrização/fisiologia , Estudos de Viabilidade , Inibidores de Poli(ADP-Ribose) Polimerases/farmacologia , Inibidores de Poli(ADP-Ribose) Polimerases/uso terapêutico , Ratos Sprague-Dawley , Fenômenos Biomecânicos
12.
J Shoulder Elbow Surg ; 32(6): 1285-1294, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36803947

RESUMO

BACKGROUND: The objective of this study was to quantify the valgus laxity and strain of the elbow ulnar collateral ligament (UCL) complex after repeated valgus stretching and subsequent recovery. Understanding these changes may have important implications in improving strategies for injury prevention and treatment. The hypothesis was that the UCL complex will demonstrate a permanent increase in valgus laxity and region-specific increase in strain as well as region-specific recovery characteristics. METHODS: Ten cadaveric elbows (7M, 3F, 61.7 ± 2.7 years) were used. Valgus angle and strain of the anterior and posterior bands of the anterior bundle and the posterior bundle were measured at 1 Nm, 2.5 Nm, 5 Nm, 7.5 Nm, and 10 Nm of valgus torque at 70° of flexion for: (1) intact UCL, (2) stretched UCL, and (3) rested UCL. To stretch the UCL, elbows were cycled with increasing valgus torque at 70° of flexion (10 Nm-20 Nm in 1 Nm increments) until the valgus angle increased 8° from the intact valgus angle measured at 1Nm. This position was held for 30 minutes. Specimens were then unloaded and rested for 2 hours. Linear mixed effects model with Tukey's post hoc test was used for statistical analysis. RESULTS: Stretching significantly increased valgus angle compared to the intact condition 3.2° ± 0.2° (P < .001). Strains of both the anterior and posterior bands of the anterior bundle were significantly increased from intact by 2.8% ± 0.9% (P = .015) and 3.1% ± 0.9% (P = .018), respectively at 10 Nm. Strain in the distal segment of the anterior band was significantly higher than the proximal segment with loads of 5 Nm and higher (P < .030). After resting, the valgus angle significantly decreased from the stretched condition by 1.0° ± 0.1° (P < .001) but failed to recover to intact levels (P < .004). After resting, the posterior band had a significantly increased strain compared to the intact state of 2.6% ± 1.4% (P = .049) while the anterior band was not significantly different from intact. CONCLUSION: After repeated valgus loading and subsequent resting, the UCL complex demonstrated permanent stretching with some recovery but not to intact levels. The anterior band demonstrated increased strain in the distal segment compared to the proximal segment with valgus loading. The anterior band was able to recover to strain levels similar to intact after resting, while the posterior band did not.


Assuntos
Ligamento Colateral Ulnar , Ligamentos Colaterais , Articulação do Cotovelo , Humanos , Cotovelo , Ligamento Colateral Ulnar/lesões , Cadáver , Fenômenos Biomecânicos , Ligamentos Colaterais/lesões
13.
Arch Orthop Trauma Surg ; 143(8): 4731-4739, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36658364

RESUMO

INTRODUCTION: Latissimus dorsi and teres major (LDTM) tendon transfer has demonstrated better clinical outcomes compared to Latissimus dorsi (LD) transfer for irreparable anterosuperior cuff (subscapularis/supraspinatus) tears; however, the biomechanical effects of these procedures are unknown. Therefore, the objective of this study was to compare kinematics and internal rotation of LDTM transfer to LD transfer for anterosuperior cuff tear. METHODS: Eight cadaveric shoulders were tested in four conditions; (1) intact, (2) anterosuperior rotator cuff tear, (3) LDTM transfer, and (4) LD transfer. Glenohumeral kinematics and internal rotation at 0°, 30°, and 60° of glenohumeral abduction in the scapular plane were measured. Muscle loading was applied based on physiological cross-sectional area ratios with three muscle loading conditions to simulate potentially increased tension due to the advanced insertion site of the transferred tendons. RESULTS: The anterosuperior rotator cuff tear leads to a significant superior shift of the humeral head compared to intact at 0° and 30° abduction (p < 0.039). Both the LDTM (p < 0.047) and LD transfers (p < 0.032) significantly shifted the humeral head inferiorly compared to the tear condition.; however, the LDTM transfer shifted the head in the anteroinferior direction compared to the LD transfer at 60° abduction and 30° ER (p < 0.045). Both LDTM and LD transfer significantly increased internal resting rotation (p < 0.008) and maximum internal rotation (p < 0.008) compared to anterosuperior rotator cuff tear and intact at 30° and 60° abduction. LDTM transfer resulted in a significant internal resting rotation compared with the LD transfer at 30° abduction with double muscle loading (p = 0.02). At 0° abduction, the LDTM transfer (p < 0.027) significantly increased maximum internal rotation compared to anterosuperior rotator cuff tear and intact. CONCLUSION: Although both LDTM and LD tendon transfer improved the abnormal humeral head apex position and internal rotation compared with the tear condition, the LDTM transfer was biomechanically superior to the LD transfer in a cadaveric model.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Músculos Superficiais do Dorso , Humanos , Lesões do Manguito Rotador/cirurgia , Transferência Tendinosa/métodos , Fenômenos Biomecânicos , Manguito Rotador/cirurgia , Amplitude de Movimento Articular/fisiologia , Cadáver
14.
J Shoulder Elbow Surg ; 32(4): 703-712, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36529382

RESUMO

BACKGROUND: Irreparable anterosuperior rotator cuff tears (IASRCTs) can result in a gradual loss of active elevation and internal rotation, superior and anterior translation of the humeral head, and cuff tear arthropathy. Joint-preserving treatment options for IASRCTs in young and high-demand elderly patients remain a subject of ongoing debate. The aim of the study was to evaluate the biomechanical efficacy of the combined latissimus dorsi and teres major tendon (LDTM) transfer and compare it to an isolated latissimus dorsi (LD) transfer in a cadaveric IASRCT model. METHODS: Eight cadaveric shoulders (mean age, 68.3 ± 5.2 years; range 58-71) were tested with a custom shoulder testing system. All specimens were tested at 0°, 30°, and 60° of glenohumeral abduction in the scapular plane under 4 conditions: (1) intact, (2) IASRCT, (3) combined LDTM transfer, and (4) isolated LD transfer. The superior and anteroinferior translation and subacromial contact pressure were measured. The effects of 3 different LD and LDTM muscle loading conditions were investigated to determine the effectiveness of the muscle transfer conditions. A linear mixed effect model was used for statistical analysis, followed by a Tukey post hoc test. RESULTS: IASRCTs significantly increased superior translation, anteroinferior translation, and subacromial peak contact pressure. Combined LDTM transfer significantly decreased superior and anteroinferior translation compared with IASRCTs in all positions and muscle loadings. Isolated LD transfer did not significantly decrease superior (P > .115) and anteroinferior translation (P > .151) compared to IASRCT at any abduction and muscle loads except superior translation at 60° abduction and 90° of external rotation (ER) (P < .036). LDTM transfer also significantly decreased peak contact pressure from the IASRCT condition at every abduction angle (P < .046). However, isolated LD transfer significantly decreased subacromial peak contact pressure only at 30° abduction and 0° and 30° of ER with triple loading (P < .048), as well as at 60° abduction and 90° of ER (P < .003). CONCLUSIONS: Combined LDTM transfer decreased superior translation, anteroinferior translation, and subacromial contact pressure compared with the IASRCT condition. Isolated LD transfer did not improve glenohumeral translation and subacromial contact pressure. Combined LDTM transfer may be a more reliable treatment option than isolated LD transfer in patients with an IASRCT.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Músculos Superficiais do Dorso , Humanos , Idoso , Pessoa de Meia-Idade , Ombro , Lesões do Manguito Rotador/cirurgia , Manguito Rotador/cirurgia , Transferência Tendinosa , Articulação do Ombro/cirurgia , Tendões , Cadáver , Fenômenos Biomecânicos , Amplitude de Movimento Articular/fisiologia
15.
Arthroscopy ; 39(1): 20-28, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35988793

RESUMO

PURPOSE: The purpose of this study was to compare the biomechanical characteristics of a fascia lata superior capsule reconstruction (FL-SCR) to the native superior capsule. METHODS: The native superior capsule of 8 cadaveric shoulders was tested with cyclic loading from 10 to 50 N for 30 cycles in 20° of glenohumeral abduction followed by load to failure at 60 mm/min. Following native superior capsule testing, FL-SCR was performed, which was tested as described for the native capsule. Paired t test was used for statistical analyses with P < .05 for significance. RESULTS: The stiffness for cycle 1 to 50 N was significantly higher for the native superior capsule compared to the FL-SCR (P = .001). By cycle 30, the stiffness between the two was not statistically different (P = .734). During load to failure, the initial stiffness to 2 mm for the FL-SCR and the native superior capsule was not statistically different (P = .262). The linear stiffness and yield load of the native superior capsule were significantly greater than that of the FL-SCR (94.5 vs 28.0 N/mm, P = .013; 386.9 vs 123.8 N, P = .029). There was no significant difference in ultimate load between the native superior capsule and the FL-SCR (444.9 vs 369.0 N, P = .413). CONCLUSIONS: FL-SCR has initial stiffness and ultimate load similar to the native superior capsule. CLINICAL RELEVANCE: The biomechanical properties of FL allograft make it an appealing option as a graft choice for superior capsule reconstruction.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Humanos , Ombro , Lesões do Manguito Rotador/cirurgia , Articulação do Ombro/cirurgia , Fascia Lata/transplante , Fenômenos Biomecânicos , Aloenxertos , Cadáver
16.
Clin Orthop Surg ; 14(4): 613-621, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36518934

RESUMO

Background: This study aimed to compare the biomechanical strength of 360° scapholunate interosseous ligament (SLIL) reconstruction only using an artificial material (AM), double dorsal limb (DDL) SLIL reconstruction only using AM, and the modified Brunelli technique (MBT) with ligament. Methods: Eight cadaver wrists were used for this study. The SL interval, SL angle, and radiolunate (RL) angle were recorded with MicroScribe. The SL distance was measured after dividing the volar and dorsal aspects. We utilized four different wrist postures (neutral, flexion, extension, and clenched fist) to compare five conditions: intact wrist, SLIL resection, 360° SLIL reconstruction using AM, DDL SLIL reconstruction using AM, and MBT SLIL reconstruction with ligament. Results: The dorsal SL distance in the SLIL resection was widened in all wrist positions. The dorsal SL distance was restored with all three techniques and in all wrist positions. The volar SL distance in the wrist extension position was widened in the SLIL resection condition. The volar SL distance was restored in the extension position after 360° SLIL reconstruction using AM condition. There were no statistically significant differences in SL and RL angles among the conditions. Conclusions: All three reconstruction techniques could restore the dorsal SL distance. However, only the 360° SLIL reconstruction using AM restored the volar SL distance in the wrist extension position. DDL SLIL reconstruction using AM tended to overcorrect, whereas 360° SLIL reconstruction using AM effectively stopped volar SL interval widening.


Assuntos
Instabilidade Articular , Osso Semilunar , Osso Escafoide , Humanos , Osso Semilunar/cirurgia , Osso Escafoide/cirurgia , Articulação do Punho/cirurgia , Ligamentos Articulares/cirurgia , Cadáver , Instabilidade Articular/cirurgia , Fenômenos Biomecânicos
17.
J Hand Surg Eur Vol ; 47(9): 944-951, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35360977

RESUMO

Clinical studies suggest that even untreated basal ulnar styloid fractures may not affect patient outcomes. This may be due to the remaining parts of the distal radioulnar ligament still attached providing sufficient residual stability of the distal radioulnar joint. We tested this hypothesis in a biomechanical cadaveric model. Dorsopalmar translation of the distal radioulnar joint and forearm rotation were measured. Seventeen specimens were tested after a simulated ulnar styloid fracture including the fovea, followed by transection of the remaining palmar (n = 9) or dorsal (n = 8) portions of the distal radioulnar ligament and finally with all remnants transected. Rotation and translation both increased significantly after the final transection compared with the foveal fracture. The increase in translation was larger after transection of the dorsal remnants. We conclude that in an ulnar styloid fracture including the fovea, some ligament components are still attached to the ulnar head, giving residual stability to the distal radioulnar joint.


Assuntos
Fraturas da Ulna , Articulação do Punho , Progressão da Doença , Antebraço , Humanos , Ligamentos , Ulna , Fraturas da Ulna/cirurgia , Articulação do Punho/cirurgia
18.
Orthop Traumatol Surg Res ; 108(3): 103224, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35104628

RESUMO

INTRODUCTION: There is much controversy about the practical role of the anterolateral ligament (ALL) and its relation to other anterolateral knee structures including the anterolateral capsule (ALC) and iliotibial band (ITB). The purpose of this cadaveric study was to investigate the effect of the ALL and ALC injuries on knee laxity with the iliotibial band (ITB) preserved in the anterior cruciate ligament (ACL)-injured knee. HYPOTHESIS: The ALL and ALC would contribute to knee joint stability during anterior translation and internal rotation of the tibia in an ACL-injured knee. MATERIAL AND METHODS: For 10 fresh-frozen cadaveric knees, we measured knee laxity with the following state of knee injuries with ITB preserved: (1) intact knee, (2) ACL-sectioned knee (ACL-), (3) additional sectioning of the ALL (ACL-/ALL-), and (4) additional sectioning of the ALC (ACL-/ALL-/ALC-). We did biomechanical measurements in internal-external rotation, anterior-posterior translation, and varus-valgus angulation for each condition at knee flexion angles of 0°, 30°, 60°, and 90°. RESULTS: After we sectioned the ALL (ACL-/ALL-), the mean IR at 0°, 30°, 60°, and 90° of knee flexion were significantly increased, compared to the intact knee (p=<0.001, <0.001, <0.001, and 0.002) and ACL- (p=<0.001, <0.001, <0.001, and 0.002). The additional transection of the ALC (ACL-/ALL-/ALC-) significantly increased IR laxity from the ACL-/ALL- at 30°, 60°, and 90° (p=0.005, 0.003, and 0.047). For anterior laxity, ACL-/ALL- resulted in significantly increased anterior laxity from the ACL- at 30° and 60° (p=0.003 and 0.019), and ACL-/ALL-/ALC- significantly increased anterior laxity even from the ACL-/ALL- at 30° and 60° (p=0.007 and 0.011). For varus laxity, ACL-/ALL- resulted in significantly increased varus laxity from both the intact knee and ACL- at 60° (p=0.004 and 0.007) and 90° (p=<0.001 and<0.001). ACL-/ALL-/ALC- resulted in significantly increased varus from ACL-/ALL- at 60° and 90° (p=<0.001 and 0.003). CONCLUSION: The anterolateral ligament and anterolateral capsule injuries in ACL-injured knees even with ITB preserved had a synergistic effect on knee laxity in the aspects of internal rotation, anterior translation, and varus angulation. LEVEL OF EVIDENCE: II, Controlled laboratory study.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Instabilidade Articular , Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/complicações , Lesões do Ligamento Cruzado Anterior/cirurgia , Fenômenos Biomecânicos , Cadáver , Humanos , Instabilidade Articular/etiologia , Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Amplitude de Movimento Articular
19.
Arthroscopy ; 38(3): 719-728, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34352334

RESUMO

PURPOSE: The purpose of this study was to biomechanically assess superior stability, subacromial contact pressures, and glenohumeral kinematics of a V-shaped anterior cable reconstruction with semitendinosus allograft (VST) in a massive rotator cuff tear (MCT) model. METHODS: Eight cadaveric shoulders (mean age, 66 years; range, 48 to 72 years) were tested with a custom testing system used to evaluate superior translation, subacromial contact pressure, and glenohumeral kinematics at 0°, 20°, and 40° glenohumeral abduction and 0°, 30°, 60°, and 90° of external rotation (ER). Conditions tested included (1) native state, (2) MCT (complete supraspinatus and ½ infraspinatus), a (3) VST. The VST was secured medially on the glenoid with 1 anchor and on the greater tuberosity with a double-row configuration using 4 anchors. RESULTS: The VST significantly decreased superior translation compared to the MCT at 0° and 20° glenohumeral abduction for 0°, 30°, and 60° humeral rotation and at 40° abduction and 0° degrees humeral rotation (P < .05). Superior translation following the VST remained significantly greater than the intact state at 0° abduction and 60° and 90° ER (P = .039 and 0.007, respectively) and 20° abduction and 30°, 60°, and 90° ER (P = .048, .003, and .004, respectively). The VST restored peak subacromial contact pressure to intact levels for all positions except 40° abduction and 60° ER. The VST did not statistically affect humeral head kinematics compared to the intact condition. CONCLUSIONS: In a biomechanical model, a VST anterior cable reconstruction partially restores superior stability and reduces peak subacromial contact pressure associated with an MCT, without affecting glenohumeral kinematics. The technique may be a consideration in the treatment of an irreparable MCT with isolated anterior cable disruption. CLINICAL RELEVANCE: The VST may provide an option for treatment of irreparable MCTs with anterior rotator cable disruption.


Assuntos
Músculos Isquiossurais , Lesões do Manguito Rotador , Articulação do Ombro , Idoso , Aloenxertos , Fenômenos Biomecânicos , Cadáver , Humanos , Amplitude de Movimento Articular , Lesões do Manguito Rotador/cirurgia , Articulação do Ombro/cirurgia
20.
Arthroscopy ; 38(5): 1398-1407, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34785299

RESUMO

PURPOSE: To compare the biomechanical effects of superior capsule reconstruction (SCR) graft fixation length determined at 20° and 40° of glenohumeral (GH) abduction. METHODS: Humeral translation, rotational range of motion (ROM), and subacromial contact pressure were quantified at 0°, 30°, and 60° of GH abduction in the scapular plane in 6 cadaveric shoulders for the following states: intact, massive rotator cuff tear, SCR with dermal allograft fixed at 20° of GH abduction (SCR 20), and SCR with dermal allograft fixed at 40° of GH abduction (SCR 40). Statistical analysis was conducted using a repeated-measures analysis of variance and a paired t test (P < .05). RESULTS: A massive cuff tear significantly increased total ROM compared with the intact state at 0° and 60° of abduction. SCR 20 or SCR 40 did not affect ROM. Compared with the intact state, the massive cuff tear model significantly increased superior translation by an average of 4.6 ± 0.5 mm in 9 of 12 positions (P ≤ .002). Both SCR 20 and SCR 40 reduced superior translation compared with the massive cuff tear model (P < .05); however, SCR 40 significantly decreased superior translation compared with SCR 20 at 0° of abduction (P ≤ .046). Peak subacromial pressure for the massive cuff tear model increased by an average of 486.8 ± 233.9 kPa relative to the intact state in 5 of 12 positions (P ≤ .037). SCR 20 reduced peak subacromial pressure in 2 of 12 positions (P ≤ .012), whereas SCR 40 achieved this in 6 of 12 positions (P ≤ .024). CONCLUSIONS: SCR with dermal allograft fixed at 20° or 40° of GH abduction decreases GH translation and subacromial pressure without decreasing ROM. CLINICAL RELEVANCE: With an increasing abduction angle for graft fixation, the medial-to-lateral graft length is decreased and the graft tension is effectively increased. Surgeons may increase shoulder stability without restricting ROM by fixing the graft at higher abduction angles. However, surgeons should remain cognizant of potential graft failure due to increased tension.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Aloenxertos/transplante , Fenômenos Biomecânicos , Cadáver , Humanos , Amplitude de Movimento Articular , Lesões do Manguito Rotador/cirurgia , Ruptura , Articulação do Ombro/cirurgia