Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
1.
Front Oncol ; 14: 1379596, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38894866

RESUMO

Introduction: We aimed to establish if stereotactic body radiotherapy to the prostate can be delivered safely using reduced clinical target volume (CTV) to planning target volume (PTV) margins on the 1.5T MR-Linac (MRL) (Elekta, Stockholm, Sweden), in the absence of gating. Methods: Cine images taken in 3 orthogonal planes during the delivery of prostate SBRT with 36.25 Gray (Gy) in 5 fractions on the MRL were analysed. Using the data from 20 patients, the percentage of radiotherapy (RT) delivery time where the prostate position moved beyond 1, 2, 3, 4 and 5 mm in the left-right (LR), superior-inferior (SI), anterior-posterior (AP) and any direction was calculated. Results: The prostate moved less than 3 mm in any direction for 90% of the monitoring period in 95% of patients. On a per-fraction basis, 93% of fractions displayed motion in all directions within 3 mm for 90% of the fraction delivery time. Recurring motion patterns were observed showing that the prostate moved with shallow drift (most common), transient excursions and persistent excursions during treatment. Conclusion: A 3 mm CTV-PTV margin is safe to use for the treatment of 5 fraction prostate SBRT on the MRL, without gating. In the context of gating this work suggests that treatment time will not be extensively lengthened when an appropriate gating window is applied.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38595787

RESUMO

The radiation therapy (RT) landscape is continuously evolving, necessitating adaptation in roles and responsibilities of radiation therapists (RTTs). Advanced Practice Radiation Therapists (APRTs) have taken on a proactive role in expanding services and assuming responsibilities within multi-professional teams. A European Society for Radiotherapy and Oncology (ESTRO) brought geographically diverse and experienced RTTs together, to discuss how advanced practice (AP) in the RTT profession should be future-proofed and create a global platform for collaboration. Challenges in achieving consensus and standardisation of APRT was identified across jurisdictions, emphasising the importance of international collaboration. Whilst highlighting the pivotal role of APRTs in driving innovation, improving patient care, and navigating the complexities of modern RT practice, this position paper presents outcomes and recommendations from the workshop. Discussions highlighted the need for standardised role definitions, education frameworks, regulatory support, and career development pathways to enable the advancement of APRT effectively. Increasing networks and collaboration is recommended to ensure APRTs can shape the future of RT.

3.
Adv Radiat Oncol ; 9(6): 101490, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38681895

RESUMO

Purpose: Swallow-related motion of the larynx is most significant in the cranio-caudal directions and of` short duration. Conventional target definition for radical radiation therapy includes coverage of the whole larynx. This study longitudinally examined respiration- and swallow-related laryngeal motions using cine-magnetic resonance imaging. We further analyzed the dosimetry to organs at risk by comparing 3D-conformal radiation therapy (3D-CRT), volumetric modulated arc therapy (VMAT), and intensity modulated radiation therapy (IMRT) techniques. Methods: Fifteen patients with T1-2 N0 glottic squamous cell carcinomas were prospectively recruited for up to 3 cine-MRI scans on the Elekta Unity MR-Linear accelerator, at the beginning, middle, and end of a course of radical radiation therapy. Swallow frequency and motion of the hyoid bone, cricoid and thyroid cartilages, and vocal cords were recorded during swallow and rest. Adapted treatment volumes consisted of gross tumor volume + 0.5-1 cm to a clinical target volume with an additional internal target volume (ITV) for personalized resting-motion. Swallow-related motion was deemed infrequent and was not accounted for in the ITV. We compared radiation therapy plans for 3D-CRT (whole larynx), VMAT (whole larynx), and VMAT and IMRT (ITV for resting motion). Results: Resting- and swallow-related motions were most prominent in the cranio-caudal plane. There were no significant changes in the magnitude of motion over the course of radiation therapy. There was a trend of a progressive reduction in the frequency of swallow. Treatment of partial larynx volumes with intensity modulated methods significantly reduced the dose to carotid arteries, compared with treatment of whole larynx volumes. Robustness analysis demonstrated that when accounting for intrafraction swallow, the total dose delivered to the ITV/planning target volume was maintained at above 95%. Conclusions: Swallow-related motions are infrequent and accounting for resting motion in an ITV is sufficient. VMAT/IMRT techniques that treat more conformal targets can significantly spare critical organs at risk such as the carotid arteries and thyroid gland, potentially reducing the risk of carotid artery stenosis-related complications and other long-term complications.

4.
Phys Imaging Radiat Oncol ; 29: 100554, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38419803

RESUMO

Background and purpose: Interfraction motion during cervical cancer radiotherapy is substantial in some patients, minimal in others. Non-adaptive plans may miss the target and/or unnecessarily irradiate normal tissue. Adaptive radiotherapy leads to superior dose-volume metrics but is resource-intensive. The aim of this study was to predict target motion, enabling patient selection and efficient resource allocation. Materials and methods: Forty cervical cancer patients had CT with full-bladder (CT-FB) and empty-bladder (CT-EB) at planning, and daily cone-beam CTs (CBCTs). The low-risk clinical target volume (CTVLR) was contoured. Mean coverage of the daily CTVLR by the CT-FB CTVLR was calculated for each patient. Eighty-three investigated variables included measures of organ geometry, patient, tumour and treatment characteristics. Models were trained on 29 patients (171 fractions). The Two-CT multivariate model could use all available data. The Single-CT multivariate model excluded data from the CT-EB. A univariate model was trained using the distance moved by the uterine fundus tip between CTs, the only method of patient selection found in published cervix plan-of-the-day studies. Models were tested on 11 patients (68 fractions). Accuracy in predicting mean coverage was reported as mean absolute error (MAE), mean squared error (MSE) and R2. Results: The Two-CT model was based upon rectal volume, dice similarity coefficient between CT-FB and CT-EB CTVLR, and uterine thickness. The Single-CT model was based upon rectal volume, uterine thickness and tumour size. Both performed better than the univariate model in predicting mean coverage (MAE 7 %, 7 % and 8 %; MSE 82 %2, 65 %2, 110 %2; R2 0.2, 0.4, -0.1). Conclusion: Uterocervix motion is complex and multifactorial. We present two multivariate models which predicted motion with reasonable accuracy using pre-treatment information, and outperformed the only published method.

5.
J Med Imaging Radiat Sci ; 54(4): 603-610, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37479627

RESUMO

PURPOSE: Patients undergoing radiotherapy are positioned to restrict motion, ensuring treatment accuracy. Immobilisation can be uncomfortable which may impact treatment accuracy. Therapeutic radiographers (TR) are responsible for managing patient comfort, yet there is little evidence to guide practice. The objective was to explore patient and RT experience of comfort management during radiotherapy and identify solutions for how comfort may be managed. MATERIALS AND METHODS: Twenty-five adult patients were purposefully recruited from Somerset NHS FT (SFT NHS) from those referred for, receiving or who had received radiotherapy within 3 months. Further criteria were that treatment delivery time on the couch exceeded 10 min (the time the patient was immobilised on the radiotherapy couch). 25 practicing TRs were recruited across the United Kingdom (UK) with experience of treatment delivery times exceeding 10 min. Semi structured interviews were conducted by the researcher at SFT NHS or in patients own homes and via telephone for TRs. Interviews were audio-recorded and transcribed verbatim. Thematic analysis was performed by SG and after familiarisation with data, generation of codes, the themes defined were reviewed by researchers and patient partners. FINDINGS: For patients, the three themes were: Supported Coping, Modification to Position or Immobilisation and Information Communication and Preparation. For TRs three main themes emerged: Supported Coping, Supporting and Adjusting Patients to Maintain Position and Preparational Approaches. CONCLUSION: This qualitative paper provided a shared voice of how comfort can be best managed from the perspective of patients and TRs. Patient and TR views of how comfort is best managed has provided solutions that may be used during radiotherapy. The study has highlighted some of the positive and negative experiences of comfort solutions based on current UK practice. This information will be used to develop recommendations in a radiotherapy comfort intervention package.


Assuntos
Adaptação Psicológica , Pessoal Técnico de Saúde , Adulto , Humanos , Pesquisa Qualitativa , Reino Unido , Comunicação
6.
Radiother Oncol ; 185: 109734, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37301263

RESUMO

The use of breath-hold techniques in radiotherapy, such as deep-inspiration breath hold, is increasing although guidelines for clinical implementation are lacking. In these recommendations, we aim to provide an overview of available technical solutions and guidance for best practice in the implementation phase. We will discuss specific challenges in different tumour sites including factors such as staff training and patient coaching, accuracy, and reproducibility. In addition, we aim to highlight the need for further research in specific patient groups. This report also reviews considerations for equipment, staff training and patient coaching, as well as image guidance for breath-hold treatments. Dedicated sections for specific indications, namely breast cancer, thoracic and abdominal tumours are also included.


Assuntos
Neoplasias da Mama , Suspensão da Respiração , Humanos , Feminino , Reprodutibilidade dos Testes , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias da Mama/radioterapia , Dosagem Radioterapêutica
7.
Br J Radiol ; 96(1146): 20220852, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37001054

RESUMO

OBJECTIVES: To measure the magnitude of intra-fraction prostate motion (IFPM) during stereotactic radiotherapy (SBRT) delivered without intra-fraction tracking.To assess if current margins adequately cover IFPM.To derive margins using new guidelines. METHODS: IFPM was determined in 20 patients receiving 36.25 Gy in 5 fractions using 97 pairs of pre- and post-treatment cone beam CT (CBCT) scans. Correlation of time between CBCT acquisitions and motion was determined. The magnitude of IFPM was compared to current margins (6 mm isotropic, 3 mm posterior). Margins were calculated using IFPM alone and updated guidelines. RESULTS: The averaged 3D root mean square IFPM was 2.5 mm (4.2 mm). Independent prostate motion was predominantly posterior (70%) and inferior (63%). There was weak correlation between posterior (ρ = 0.38) and inferior (ρ = 0.36) IFPM and time. IFPM greater than current margins occurred in 8 of 97 fractions, six in the posterior direction. Margins were ≤3.5 mm using IFPM alone and ≤3.3 mm Left 3.5 mm Right, 7.0 mm inferior, 3.7 mm superior, 4.4 mm anterior and 3.3 mm posterior using new guidelines, compensating for motion in 92% of fractions. CONCLUSIONS: Our current SBRT margins account for 92% of IFPM, predominantly posterior and inferior. Although updated guidelines suggest an increase in margins inferiorly, any increase must be balanced against the possibility of increased toxicity, particularly if biochemical control and side-effects are favourable with current practice. ADVANCES IN KNOWLEDGE: The difference between current clinical margins and those determined using updated guidance is demonstrated. The implications must be considered against clinical outcomes.


Assuntos
Neoplasias da Próstata , Radiocirurgia , Radioterapia Guiada por Imagem , Masculino , Humanos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Incerteza , Movimento (Física) , Tomografia Computadorizada de Feixe Cônico , Planejamento da Radioterapia Assistida por Computador
8.
Radiography (Lond) ; 29 Suppl 1: S24-S31, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36841685

RESUMO

INTRODUCTION: There is little research regarding the experiences of patient comfort and how it is best managed in radiotherapy. The aim of this study was to explore the experiences of patient and therapeutic radiographer views of comfort during radiotherapy. METHODS: This qualitative study involved semi-structured interviews, with cancer patients (n = 25) and therapeutic radiographers (n = 25), conducted between January-July 2019. Patients were recruited from one radiotherapy clinic and therapeutic radiographers were recruited from across the United Kingdom via specialist interest groups and social media. Interviews were audio-recorded and transcribed verbatim. Thematic analysis was used to analyse the data separately between both groups and shared themes were identified. RESULTS: Four themes were identified of which two themes were shared among both the patients and therapeutic radiographer. Emotional Health was a shared theme highlighting experiences such as stress, vulnerability and privacy. The second shared theme, Positioning and Immobilisation Experiences, concerned how patients' experience being physically positioned and using immobilisation for accurate radiotherapy. The theme Information and Communication Experience was derived from patients highlighting concerns over sharing and provision of information and ways of communication. The last theme, Environmental Experience, emerged from the patient interviews and related to the first impressions of the radiotherapy environment such as reception or treatment rooms and how this effects the overall feelings of comfort. CONCLUSION: This qualitative study has provided the shared voice of patients and therapeutic radiographers and their experiences of comfort during radiotherapy. These shared experiences emphasise the importance of considering comfort holistically and not just from a physical context. This information can be used by therapeutic radiographers to better understand their patients experiences and needs to provide better comfort during radiotherapy to improve patients' outcomes. IMPLICATIONS FOR PRACTICE: The clinical implications of our study can encourage Therapeutic Radiographers to provide holistic care for their patients throughout the pathway and specifically to comfort patients while they are having treatment. In the short term this could be via simple adaptions to practice while in the long term, research is needed to develop comfort interventions for patients receiving radiotherapy.


Assuntos
Radioterapia (Especialidade) , Humanos , Pesquisa Qualitativa , Reino Unido
9.
Radiother Oncol ; 180: 109457, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36608770

RESUMO

BACKGROUND AND PURPOSE: The implementation of MRI-guided online adaptive radiotherapy has facilitated the extension of therapeutic radiographers' roles to include contouring, thus releasing the clinician from attending daily treatment. Following undergoing a specifically designed training programme, an online interobserver variability study was performed. MATERIALS AND METHODS: 117 images from six patients treated on a MR Linac were contoured online by either radiographer or clinician and the same images contoured offline by the alternate profession. Dice similarity coefficient (DSC), mean distance to agreement (MDA), Hausdorff distance (HD) and volume metrics were used to analyse contours. Additionally, the online radiographer contours and optimised plans (n = 59) were analysed using the offline clinician defined contours. After clinical implementation of radiographer contouring, target volume comparison and dose analysis was performed on 20 contours from five patients. RESULTS: Comparison of the radiographers' and clinicians' contours resulted in a median (range) DSC of 0.92 (0.86 - 0.99), median (range) MDA of 0.98 mm (0.2-1.7) and median (range) HD of 6.3 mm (2.5-11.5) for all 117 fractions. There was no significant difference in volume size between the two groups. Of the 59 plans created with radiographer online contours and overlaid with clinicians' offline contours, 39 met mandatory dose constraints and 12 were acceptable because 95 % of the high dose PTV was covered by 95 % dose, or the high dose PTV was within 3 % of online plan. A clinician blindly reviewed the eight remaining fractions and, using trial quality assurance metrics, deemed all to be acceptable. Following clinical implementation of radiographer contouring, the median (range) DSC of CTV was 0.93 (0.88-1.0), median (range) MDA was 0.8 mm (0.04-1.18) and HD was 5.15 mm (2.09-8.54) respectively. Of the 20 plans created using radiographer online contours overlaid with clinicians' offline contours, 18 met the dosimetric success criteria, the remaining 2 were deemed acceptable by a clinician. CONCLUSION: Radiographer and clinician prostate and seminal vesicle contours on MRI for an online adaptive workflow are comparable and produce clinically acceptable plans. Radiographer contouring for prostate treatment on a MR-linac can be effectively introduced with appropriate training and evaluation. A DSC threshold for target structures could be implemented to streamline future training.


Assuntos
Neoplasias da Próstata , Radioterapia Guiada por Imagem , Masculino , Humanos , Próstata , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Glândulas Seminais , Pelve , Radioterapia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
10.
Artigo em Inglês | MEDLINE | ID: mdl-36654720

RESUMO

The implementation of MRI-guided online adaptive radiotherapy has enabled extension of therapeutic radiographers' roles to include contouring. An offline interobserver variability study compared five radiographers' and five clinicians' contours on 10 MRIs acquired on a MR-Linac from 10 patients. All contours were compared to a "gold standard" created from an average of clinicians' contours. The median (range) DSC of radiographers' and clinicians' contours compared to the "gold standard" was 0.91 (0.86-0.96), and 0.93 (0.88-0.97) respectively illustrating non-inferiority of the radiographers' contours to the clinicians. There was no significant difference in HD, MDA or volume size between the groups.

11.
Pract Radiat Oncol ; 13(2): 132-147, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36481683

RESUMO

PURPOSE: Radiation therapy is the key treatment for locally advanced cervical cancer. Organ motion presents a challenge to accurate targeting of external beam radiation therapy. The plan-of-the-day (PotD) adaptive approach is therefore an attractive option. We present our experience and the procedural steps required to implement PotD for cervix cancer. METHODS AND MATERIALS: We reviewed relevant studies on organ motion and adaptive radiation therapy identified through a literature search and cross referencing. These included 10 dosimetric and 3 quality of life studies directly assessing the PotD approach to radiation therapy in cervix cancer. RESULTS: Studies show improvements in target coverage and reduction of dose received by normal tissues and suggest improved toxicity. Clinical implementation of PotD has been slow because of a number of difficulties and uncertainties, which we discuss with the aim of helping teams to implement PotD at their center. CONCLUSIONS: The PotD approach improves dosimetry and may improve toxicity. We describe a framework to assist with practical implementation.


Assuntos
Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Qualidade de Vida , Colo do Útero , Dosagem Radioterapêutica
12.
Int J Radiat Oncol Biol Phys ; 115(2): 305-316, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36150450

RESUMO

PURPOSE: Our purpose was to report 5-year efficacy and toxicity of intraprostatic lesion boosting using standard and hypofractionated radiation therapy. METHODS AND MATERIALS: DELINEATE (ISRCTN 04483921) is a single center phase 2 multicohort study including standardly fractionated (cohort A: 74 Gy/37F to prostate and seminal vesicles [PSV]; cohort C 74 Gy/37F to PSV plus 60 Gy/37F to pelvic lymph nodes) and moderately hypofractionated (cohort B: 60 Gy/20F to PSV) prostate intensity-modulated radiation therapy patients with National Comprehensive Cancer Network intermediate/high-risk disease. Patients received an integrated boost of 82 Gy (cohorts A and C) or 67 Gy (cohort B) to multiparametric magnetic resonance imaging identified lesion(s). Primary endpoint was late Radiation Therapy Oncology Group (RTOG) gastrointestinal (GI) toxicity at 1 year. Secondary endpoints were acute and late toxicity (clinician and patient reported) and freedom from biochemical/clinical failure at 5 years. RESULTS: Two hundred and sixty-five men were recruited and 256 were treated (55 cohort A, 153 cohort B, and 48 cohort C). Median follow-up for each cohort was >5 years. Cumulative late RTOG grade 2+ GI toxicity at 1 year was 3.6% (95% confidence interval [CI], 0.9%-13.8%) (cohort A), 7.2% (95% CI, 4%-12.6%) (cohort B), and 8.4% (95% CI, 3.2%-20.8%) (cohort C). Cumulative late RTOG grade 2+ GI toxicity to 5 years was 12.8% (95% CI, 6.3%-25.1%) (cohort A), 14.6% (95% CI, 9.9%-21.4%) (cohort B), and 20.7% (95% CI, 11.2%-36.2%) (cohort C). Cumulative RTOG grade 2+ genitourinary toxicity to 5 years was 12.9% (95% CI, 6.4%-25.2%) (cohort A), 18.2% (95% CI, 12.8%-25.4%) (cohort B), and 18.2% (95% CI, 9.5%-33.2%) (cohort C). Five-year freedom from biochemical/clinical failure was 98.2% (95% CI, 87.8%-99.7%) (cohort A), 96.7% (95% CI, 91.3%- 98.8%) (cohort B), and 95.1% (95% CI, 81.6-98.7%) (cohort C). CONCLUSIONS: The DELINEATE trial has shown safety, tolerability, and feasibility of focal boosting in 20 or 37 fractions. Efficacy results indicate a low chance of prostate cancer recurrence 5 years after radiation therapy. Evidence from ongoing phase 3 randomized trials is awaited.


Assuntos
Gastroenteropatias , Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Humanos , Masculino , Gastroenteropatias/etiologia , Recidiva Local de Neoplasia/etiologia , Próstata/patologia , Neoplasias da Próstata/patologia , Hipofracionamento da Dose de Radiação , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos
13.
Artigo em Inglês | MEDLINE | ID: mdl-35243043

RESUMO

The implementation of adaptive radiotherapy for prostate cancer compensates for inter-fraction motion, at the penalty of increased time in room. The subsequent increase in bladder filling may impact dosimetry, which we have investigated on ten patients treated on the MR-linac. Patients drank water before treatment, to achieve a bladder volume of 200-300 cm3. Bladder and bowel were re-outlined offline on 140 images and plans recalculated. All mandatory bladder dose constraints and 99.1% of bowel constraints were achieved at time of treatment, despite varying bladder volumes and varying adherence to original bladder filling guidance.

14.
BMJ Open ; 12(3): e050288, 2022 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-35296471

RESUMO

OBJECTIVE: The aim of this study was to elicit the views of relevant stakeholders on the design of a device using simulated affective touch to reduce procedural anxiety surrounding radiotherapy and imaging. DESIGN: This qualitative study collected data from focus groups which were then analysed using inductive thematic analysis in line with Braun and Clarke's methods. PARTICIPANTS AND SETTING: Twenty patients and carers were recruited, as well as 10 healthcare practitioners involved in either delivering radiotherapy or imaging procedures. RESULTS: Patients, carers and healthcare practitioners agreed on some aspects of the device design, such as ensuring the device is warm and flexible in where it can be used on the body. However, patient and healthcare practitioner cohorts had at times differing viewpoints. For example, healthcare practitioners provided professional perspectives and required easy cleaning of the device. Meanwhile patients focused on anxiety-relieving factors, such as the tactile sensation of the device being either a vibration or pulsation. There was no consensus on who should control the device. CONCLUSIONS: The desired features of a simulated affective touch device have been investigated. Different priorities of patients and their carers and healthcare practitioners were evident. Any design must incorporate such features as to appease both groups. Areas where no consensus was reached could be further explored, alongside including further patient and public involvement in the form of a project advisory group.


Assuntos
Cuidadores , Tato , Ansiedade/prevenção & controle , Diagnóstico por Imagem/psicologia , Grupos Focais , Humanos , Pesquisa Qualitativa , Radioterapia/psicologia
15.
Eur J Cancer Care (Engl) ; 31(2): e13564, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35191096

RESUMO

OBJECTIVE: Little is understood about the anxiety experienced by cancer patients undergoing radiotherapy or investigative imaging. Our aim was to identify sources of anxiety, the points along the cancer journey where anxiety occurred and methods to alleviate it. METHODS: Six focus groups were conducted with cancer patients (n = 17), caregivers (n = 3) and healthcare practitioners (HCPs; n = 10) in the radiotherapy department. Patients described specific elements in the care pathway which induced anxiety, while HCPs focused on their perception of the patient experience. Thematic analysis was used to analyse data. RESULTS: Three broad themes emerged: The Environment, The Individual and The Unknown. The physical environment of the hospital, inside the scanner for example, emerged as a key source of anxiety. The impact of cancer on patients' individual lives was significant, with many feeling isolated. The majority of participants described anxiety associated with the unknown. HCPs reported difficulty in identifying the anxious patient. CONCLUSIONS: Anxiety is experienced throughout the cancer pathway. Common sources include the physical environment and the uncertainty associated with having cancer. Identifying both anxiety-inducing factors, and the anxious patients themselves, is crucial to enable targeted interventions to alleviate anxiety.


Assuntos
Ansiedade , Cuidadores , Ansiedade/etiologia , Medo , Humanos , Cuidados Paliativos , Pesquisa Qualitativa
16.
Artigo em Inglês | MEDLINE | ID: mdl-35198744

RESUMO

Two multicentre adaptive radiotherapy trials utilising Plan of the Day (PoD) with a library of plans were introduced in 35 centres. The common issues that arose from all centres when introducing PoD were collated retrospectively, through reviewing the data pertaining to the pre-trial and on-trial quality assurance programme. It was found that 1,295 issues arose when introducing PoD in outlining, planning, treatment delivery i.e., PoD selection, and in the overall process of delivering PoD. There was no difference in the number of issues that arose from pre-trial to on-trial. Thus, it is recommended that the implementation of PoD is supported by guidance, reviews, and continuous monitoring.

17.
Radiat Oncol ; 16(1): 183, 2021 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-34544481

RESUMO

Hybrid magnetic resonance (MR)-guided linear accelerators represent a new horizon in the field of radiation oncology. By harnessing the favorable combination of on-board MR-imaging with the possibility to daily recalculate the treatment plan based on real-time anatomy, the accuracy in target and organs-at-risk identification is expected to be improved, with the aim to provide the best tailored treatment. To date, two main MR-linac hybrid machines are available, Elekta Unity and Viewray MRIdian. Of note, compared to conventional linacs, these devices raise practical issues due to the positioning phase for the need to include the coil in the immobilization procedure and in order to perform the best reproducible positioning, also in light of the potentially longer treatment time. Given the relative novelty of this technology, there are few literature data regarding the procedures and the workflows for patient positioning and immobilization for MR-guided daily adaptive radiotherapy. In the present narrative review, we resume the currently available literature and provide an overview of the positioning and setup procedures for all the anatomical districts for hybrid MR-linac systems.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias/radioterapia , Aceleradores de Partículas , Posicionamento do Paciente , Radioterapia Guiada por Imagem/métodos , Neoplasias Abdominais/radioterapia , Neoplasias Encefálicas/radioterapia , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Neoplasias Torácicas/radioterapia
18.
Phys Imaging Radiat Oncol ; 18: 68-77, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34258411

RESUMO

BACKGROUND AND PURPOSE: Transperineal ultrasound (TPUS) is used clinically for directly assessing prostate motion. Factors affecting accuracy and precision in TPUS motion estimation must be assessed to realise its full potential. METHODS AND MATERIALS: Patients were imaged using volumetric TPUS during the Clarity-Pro trial (NCT02388308). Prostate motion was measured online at patient set-up and offline by experienced observers. Cone beam CT with markers was used as a comparator and observer performance was also quantified. The influence of different clinical factors was examined to establish specific recommendations towards efficacious ultrasound guided radiotherapy. RESULTS: From 330 fractions in 22 patients, offline observer random errors were 1.5 mm, 1.3 mm, 1.9 mm (left-right, superior-inferior, anteroposterior respectively). Errors increased in fractions exhibiting poor image quality to 3.3 mm, 3.3 mm and 6.8 mm. Poor image quality was associated with inconsistent probe placement, large anatomical changes and unfavourable imaging conditions within the patient. Online matching exhibited increased observer errors of: 3.2 mm, 2.9 mm and 4.7 mm. Four patients exhibited large systematic residual errors, of which three had poor quality images. Patient habitus showed no correlation with observer error, residual error, or image quality. CONCLUSIONS: TPUS offers the unique potential to directly assess inter- and intra-fraction motion on conventional linacs. Inconsistent image quality, inexperienced operators and the pressures of the clinical environment may degrade precision and accuracy. Experienced operators are essential and cross-centre standards for training and QA should be established that build upon current guidance. Greater use of automation technologies may further minimise uncertainties.

19.
Clin Transl Radiat Oncol ; 30: 31-37, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34307911

RESUMO

INTRODUCTION: With the implementation of new radiotherapy technology, it is imperative that patient experience is investigated alongside efficacy and outcomes. This paper presents the development of a specifically designed validated questionnaire and a first report of international multi-institutional preliminary patient experience of MRI-guided adaptive radiotherapy (MRgART) on the 1.5 T MR-Linac (MRL). METHODS: A patient experience questionnaire was developed and validated before being distributed to the Elekta MRL Consortium, to gather first patient-reported experience from participating centres worldwide. The final version of the questionnaire contains 18 questions covering a range of themes and was scored on a Likert scale of 0-3. Responses were post-processed so that a score of 0 represents a negative response and 3 represents the most favourable response. These results were analysed for patient-reported experience of treatment on the MRL. Results were also analysed for internal consistency of the questionnaire using Chronbach's Alpha and the questionnaire contents were validated for relevance using content validity indexes (CVI). RESULTS: 170 responses were received from five centres, representing patients with a wide range of tumour treatment sites from four different countries. MRgART was well tolerated with an 84% favourable response across all questions and respondents. When analysed by theme, all reported the highest percentage of results in the favourable categories (2 and 3). Internal consistency in the questionnaire was high (Cronbach's α = 0.8) and the item-level CVI for each question was 0.78 or above and the Scale-level CVI was 0.93, representing relevant content. CONCLUSION: The developed questionnaire has been validated as relevant and appropriate for use in reporting experience of patients undergoing treatment on the MRL. The overall patient-reported experience and satisfaction from multiple centres within the Elekta MRL Consortium was consistently high. These results can reinforce user confidence in continuing to expand and develop MRL use in adaptive radiotherapy.

20.
Artigo em Inglês | MEDLINE | ID: mdl-34013073

RESUMO

More than 60,000 plastic cups were used annually for bladder preparation in one radiotherapy centre. As an alternative, patients were provided with a specifically designed reusable water bottle, aiming to reduce waste and improve bladder filling compliance. Cup usage and bladder volume at treatment were calculated pre- and post-implementation. Bladder volume was measured as a percentage of the planned volume and grouped for analysis. Cup usage halved from 12,000 cups to 6000 cups. Percentage of bladder volumes in the optimal group increased from 47% to 54%. The introduction of water bottles reduced plastic cup usage and increased bladder filling compliance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA