Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
J Comput Assist Tomogr ; 48(5): 675-682, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38595174

RESUMO

OBJECTIVE: The aim of this study was to compare portal venous phase photon-counting CT (PCCT) using 20 cc less than weight-based contrast dosing with energy-integrating detector CT (EID-CT) using weight-based dosing by quantitative and qualitative analysis. METHODS: Fifty adult patients who underwent a reduced intravenous contrast dose portal venous phase PCCT from May 1, 2023, to August 10, 2023, and a prior portal-venous EID-CT with weight-based contrast dosing were retrospectively identified. Hounsfield units (HU) and noise (SD of HU) were obtained from region-of-interest measurements on 70-keV PCCT and EID-CT in 4 hepatic segments, the main and right portal vein, and both paraspinal muscles. Signal-to-noise and contrast-to-noise ratios were computed. Three abdominal radiologists qualitatively assessed overall image quality, hepatic enhancement, and confidence for metastasis identification on 5-point Likert scales. Readers also recorded the presence/absence of hepatic metastases. Quantitative variables were compared with paired t tests, and multiple comparisons were accounted for with a Bonferroni-adjusted α level of .0016. Ordinal logistic regression was used to evaluate qualitative assessments. Interreader agreement for hepatic metastases was calculated using Fleiss' κ. RESULTS: Fifty patients (32 women; mean [SD] age, 64 [13] years) were included. There was no significant difference in hepatic HU, portal vein HU, noise, and signal-to-noise or contrast-to-noise ratio between reduced contrast dose portal venous phase PCCT versus EID-CT (all P s > 0.0016). Image quality, degree of hepatic enhancement, and confidence for metastasis identification were not different for reduced dose PCCT 70-keV images and EID-CT ( P = 0.06-0.69). κ Value for metastasis identification was 0.86 (95% confidence interval, 0.70-1.00) with PCCT and 0.78 (95% confidence interval, 0.59-0.98) with EID-CT. CONCLUSION: Reduced intravenous contrast portal venous phase PCCT 70-keV images had similar attenuation and image quality as EID-CT with weight-based dosing. Metastases were identified with near-perfect agreement in reduced dose PCCT 70-keV images.


Assuntos
Meios de Contraste , Veia Porta , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Meios de Contraste/administração & dosagem , Veia Porta/diagnóstico por imagem , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Idoso , Estudos Retrospectivos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Adulto , Idoso de 80 Anos ou mais , Razão Sinal-Ruído , Fótons
2.
Eur J Radiol ; 175: 111437, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38520805

RESUMO

PURPOSE: To calculate the prevalence of pancreatic cysts on photon counting CT (PCCT) and compare with that of 128-slice conventional energy-integrating detector CT (EIDCT). METHOD: A retrospective single institution database search identified all contrast-enhanced abdominal CT examinations performed at an outpatient facility that has both a PCCT and EIDCT between 4/11/2022 and 7/26/2022. The presence and size of pancreatic cysts were recorded. In patients with PCCT reported pancreatic cysts, prior CT imaging (EIDCT) was reviewed for reported pancreatic cysts. Fisher's exact test was used to compare the pancreatic cyst detection rate for PCCT and EIDCT. Wilcoxon rank sum test was used to compare cyst size and patient age. A p <.05 indicated statistical significance. RESULTS: 2494 patients were included. Our pancreatic cyst detection rate was 4.9 % (49/1009) with PCCT and 3.0 % (44/1485) for EIDCT (p =.017). For CT angiograms, pancreatic cysts were detected in 6.6 % (21/319) with PCCT and 0.0 % (0/141) with EIDCT (p <.001). Pancreatic cyst detection rate was not statistically different for portal venous, enterography, renal mass, pancreas, 3-phase liver, or venogram protocols (all p >.05). Mean[SD] pancreatic cyst size was 13.7[9.7]mm for PCCT and 15.3[14.7] for EIDCT (p =.95). 55.1 % (27/49) of PCCT and 61.4 % (27/44) of EIDCT that described pancreatic cysts had prior contrast-enhanced EIDCTs. Of these, 40.7 % (11/27) of PCCT and 14.8 % (4/27) of EIDCT described pancreatic cysts were not previously reported (p =.027). CONCLUSIONS: Photon-counting CT afforded greater pancreatic cyst detection than conventional energy-integrating detector CT, particularly with CT angiograms.


Assuntos
Cisto Pancreático , Fótons , Tomografia Computadorizada por Raios X , Humanos , Cisto Pancreático/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Idoso , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso de 80 Anos ou mais , Meios de Contraste
3.
Abdom Radiol (NY) ; 49(1): 271-278, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37814149

RESUMO

PURPOSE: To determine optimal iodine density thresholds for active inflammation in CD patients with PCCT enterography and determine if iodine density can be used to stratify CD activity severity. METHODS: A retrospective PACS search identified patients with CD imaged with PCCT enterography from 4/11/2022 to 10/30/2022 and with clinical notes, endoscopic/surgical pathology and available source PCCT data for iodine density analysis. Two abdominal radiologists with expertise in CD each drew two region of interest measurements within the visibly most affected region of terminal or neoterminal ileum wall on commercially available system (SyngoVia). Radiologists were blinded to clinical information and pathologic findings. Disease activity and severity were recorded from the pathology report. Harvey-Bradshaw Index, medications, and laboratory values were recorded. Receiver operating characteristic (ROC) curves were utilized to determine the optimum iodine density threshold for active inflammation and mild versus moderate-to-severe inflammation. Intra- and inter-reader agreement was assessed by intra-class correlation coefficient (ICC). RESULTS: 23 CD patients (15 females; mean [SD] age: 52 [17] years) imaged with PCCT enterography were included. 15/23 had active inflammation: 9/15 mild, 4/15 moderate, and 2/15 severe active inflammation. The optimal iodine density threshold for active inflammation was 2.7 mg/mL, with 97% sensitivity, 100% specificity, and 98% accuracy (AUC = 1.00). The optimal iodine density threshold for distinguishing mild from moderate-to-severe inflammation was 3.4 mg/mL, with 83% sensitivity, 89% specificity, and 87% accuracy (AUC = 0.85). Intra-reader reliability (R1/R2) ICC was 0.81/0.86. Inter-reader reliability ICC was 0.94. CONCLUSION: Iodine density from PCCT enterography can distinguish mild from moderate-to-severe active inflammation.


Assuntos
Doença de Crohn , Iodo , Feminino , Humanos , Pessoa de Meia-Idade , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/patologia , Estudos Retrospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Inflamação/diagnóstico por imagem , Inflamação/patologia
4.
Gastrointest Endosc Clin N Am ; 33(3): 519-531, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37245933

RESUMO

This article reviews the types of pancreatic cysts encountered in Radiologic practice. It summarizes the malignancy risk of each of the following: serous cystadenoma, mucinous cystic tumor, intraductal papillary mucinous neoplasm main duct and side branch, and some miscellaneous cysts such as neuroendocrine tumor and solid pseudopapillary epithelial neoplasm. Specific reporting recommendations are given. The choice between radiology follow-up versus endoscopic analysis is discussed.


Assuntos
Neoplasias Císticas, Mucinosas e Serosas , Cisto Pancreático , Neoplasias Pancreáticas , Radiologia , Humanos , Cisto Pancreático/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Radiografia
5.
Gastrointest Endosc Clin N Am ; 33(3): 533-546, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37245934

RESUMO

Pancreatic cystic lesions are frequently identified on cross-sectional imaging. As many of these are presumed branch-duct intraductal papillary mucinous neoplasms, these lesions generate much anxiety for the patients and clinicians, often necessitating long-term follow-up imaging and even unnecessary surgical resections. However, the incidence of pancreatic cancer is overall low for patients with incidental pancreatic cystic lesions. Radiomics and deep learning are advanced tools of imaging analysis that have attracted much attention in addressing this unmet need, however, current publications on this topic show limited success and large-scale research is needed.


Assuntos
Adenocarcinoma Mucinoso , Carcinoma Ductal Pancreático , Cisto Pancreático , Neoplasias Pancreáticas , Humanos , Carcinoma Ductal Pancreático/patologia , Carcinoma Ductal Pancreático/cirurgia , Adenocarcinoma Mucinoso/patologia , Adenocarcinoma Mucinoso/cirurgia , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Pâncreas/patologia , Cisto Pancreático/diagnóstico por imagem
6.
Abdom Radiol (NY) ; 48(7): 2219-2227, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37097450

RESUMO

PURPOSE: To compare dual-source dual-energy CT enterography (dsDECTE) obtained iodine density (I) (mg/mL) and I normalized to the aorta (I%) with Crohn's disease (CD) phenotypes defined by the SAR-AGA small bowel CD consensus statement. METHODS: Fifty CD patients (31 male, 19 female; mean [SD] age: 50.4 [15.2] years) who underwent dsDECTE were retrospectively identified. Two abdominal radiologists assigned CD phenotypes: no active inflammation (group-2), active inflammation without (group-3) or with luminal narrowing (group-4), stricture with active inflammation (group-5), stricture without active inflammation (group-1), and penetrating disease (group-6). Semiautomatic prototype software was used to determine the median I and I% of CD-affected small bowel mucosa for each patient. The means of the I and I% medians were compared among 4 groups ("1 + 2", "3 + 4", "5", "6") using one-way ANOVA (significance level 0.05 for each outcome) for each outcome individually followed by Tukey's range test for pairwise comparisons with adjusted p-values (overall alpha = 0.05). RESULTS: Mean [SD] I was 2.14 [1.07] mg/mL for groups 1 + 2 (n = 16), 3.54 [1.71] mg/mL for groups 3 + 4 (n = 15), 5.5 [3.27] mg/mL for group- "5" (n = 9), and 3.36 [1.43] mg/mL for group-"6" (n = 10) (ANOVA p = .001; group "1 + 2" versus "5" adj-p = .0005). Mean [SD] I% was 21.2 [6.13]% for groups 1 + 2, 39.47 [9.71]% for groups 3 + 4, 40.98 [11.76]% for group-5, and 35.01 [7.58]% for group-6 (ANOVA p < .0001; groups "1 + 2" versus "3 + 4" adj-p < .0001, group "1 + 2" versus "5" adj-p < .0001, and groups "1 + 2" versus "6" adj-p = .002). CONCLUSION: Iodine density obtained from dsDECTE significantly differed among CD phenotypes defined by SAR-AGA, with I (mg/mL) increasing with phenotype severity and decreasing for penetrating disease. I and I% can be used to phenotype CD.


Assuntos
Doença de Crohn , Iodo , Masculino , Feminino , Humanos , Doença de Crohn/diagnóstico por imagem , Constrição Patológica , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Inflamação , Fenótipo , Imageamento por Ressonância Magnética
7.
Abdom Radiol (NY) ; 48(9): 2978-2985, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36871233

RESUMO

PURPOSE: Given that ileal pouch-anal anastomosis (IPAA) surgery is a technically challenging and high-morbidity procedure, there are numerous pertinent imaging findings that need to be clearly and efficiently communicated to the IBD surgeons for essential patient management and surgical planning. Structured reporting has been increasingly used over the past decade throughout various radiology subspecialties to improve reporting clarity and completeness. We compare structured versus non-structured reporting of pelvic MRI for ileal pouch to evaluate for clarity and effectiveness. METHODS: 164 consecutive pelvic MRI's for ileal pouch evaluation, excluding subsequent exams for the same patient, acquired between 1/1/2019 and 7/31/2021 at one institution were included, before and after implementation (11/15/2020) of a structured reporting template, which was created with institutional IBD surgeons. Reports were assessed for the presence of 18 key features required for complete ileal pouch assessment: anastomosis (IPAA, tip of J, pouch body), cuff (length, cuffitis), pouch body (size, pouchitis, stricture), pouch inlet/pre-pouch ileum (stricture, inflammation, sharp angulation), pouch outlet (stricture), peripouch mesentery (position, mesentery twist), pelvic abscess, peri-anal fistula, pelvic lymph nodes, and skeletal abnormalities. Subgroup analysis was performed based on reader experience and divided into three categories: experienced (n = 2), other intra-institutional (n = 20), or affiliate site (n = 6). RESULTS: 57 (35%) structured and 107 (65%) non-structured pelvic MRI reports were reviewed. Structured reports contained 16.6 [SD:4.0] key features whereas non-structured reports contained 6.3 [SD:2.5] key features (p < .001). The largest improvement following template implementation was for reporting sharp angulation of the pouch inlet (91.2% vs. 0.9%, p < .001), tip of J suture line and pouch body anastomosis (both improved to 91.2% from 3.7%). Structured versus non-structured reports contained mean 17.7 versus 9.1 key features for experienced readers, 17.0 versus 5.9 for other intra-institutional readers, and 8.7 versus 5.3 for affiliate site readers. CONCLUSION: Structured reporting of pelvic MRI guides a systematic search pattern and comprehensive evaluation of ileal pouches, and therefore facilitates surgical planning and clinical management. This standardized reporting template can serve as baseline at other institutions for adaptation based on specific radiology and surgery preferences, fostering a collaborative environment between radiology and surgery, and ultimately improving patient care.


Assuntos
Bolsas Cólicas , Doenças Inflamatórias Intestinais , Proctocolectomia Restauradora , Humanos , Constrição Patológica/cirurgia , Proctocolectomia Restauradora/métodos , Imageamento por Ressonância Magnética , Complicações Pós-Operatórias
8.
Abdom Radiol (NY) ; 47(10): 3406-3413, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35833999

RESUMO

PURPOSE: To compare terminal ileum (TI) mucosal iodine density obtained at dual-energy CT enterography (DECTE) with conventional CT interpretation and endoscopy in patients with Crohn's disease (CD). MATERIALS AND METHODS: Twenty-three CD patients (14 men; mean[SD] age:48.1[16.7] years) with endoscopy within 30 days of DECTE were retrospectively identified. An inflammatory bowel disease gastroenterologist reviewed endoscopic images. Two radiologists qualitatively assessed the presence of active TI inflammation. Mean iodine density normalized to the aorta (I%), mean absolute iodine density (I), and iodine density standard deviation (ISD) from the distal 2 cm ileum (TI) mucosa obtained using semiautomatic prototype software were compared with endoscopic assessment using Mann Whitney tests. The optimal threshold I% and I were determined from receiver operating curves (ROC). Sensitivity and specificity of conventional interpretation and determined iodine thresholds were compared using McNemar's test. Inter-reader agreement was assessed using kappa. A p < 0.05 indicated statistical significance. RESULTS: Twelve (52.1%) patients had endoscopic active inflammation. I% was 37.9[13.3]% for patients with and 21.7[7.5]% for patients without endoscopic active inflammation (p = 0.001). The optimal ROC threshold 24.6% had 100% sensitivity and 81.8% specificity (AUC = 0.909, 95% CI 0.777-1). I was 2.44[0.73]mg/mL for patients with and 1.77[1.00]mg/mL for patients without active endoscopic inflammation (p = 0.0455). The optimal ROC threshold 1.78 mg/mL I had 91.7% sensitivity and 63.6% specificity (AUC = 0.75, 95% CI 0.532-0.968). ISD was similar for patients with and without endoscopic active inflammation (0.82[0.33]mg/mL and 0.77[0.28]mg/mL, respectively, p = 0.37). Conventional interpretation sensitivity and specificity (R1/R2) were 83.3%/91.7% and 72.7%/54.5%, respectively (all p > 0.05) with moderate inter-reader agreement (Κ = 0.542[95% CI 0.0202-0.088]). CONCLUSION: Mean normalized iodine density is highly sensitive and specific for endoscopic active inflammation. DECTE could be considered as a surrogate to endoscopy in CD patients. Despite trends towards improved sensitivity and specificity compared with conventional interpretation, future larger studies are needed.


Assuntos
Doença de Crohn , Iodo , Meios de Contraste , Doença de Crohn/diagnóstico por imagem , Endoscopia Gastrointestinal , Humanos , Inflamação/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
9.
AJR Am J Roentgenol ; 219(6): 903-914, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35856454

RESUMO

Pancreatic ductal adenocarcinoma (PDAC) is one of the most aggressive malignancies, with a dismal survival rate. Screening the general population for early detection of PDAC is not recommended, but because early detection improves survival, high-risk individuals, defined as those meeting criteria based on a family history of PDAC and/or the presence of known pathogenic germline variant genes with PDAC risk, are recommended to undergo screening with MRI and/or endoscopic ultrasound at regular intervals. The Pancreatic Cancer Early Detection (PRECEDE) Consortium was formed in 2018 and is composed of gastroenterologists, geneticists, pancreatic surgeons, radiologists, statisticians, and researchers from 40 sites in North America, Europe, and Asia. The overarching goal of the PRECEDE Consortium is to facilitate earlier diagnosis of PDAC for high-risk individuals to increase survival of the disease. A standardized MRI protocol and reporting template are needed to enhance the quality of screening examinations, improve consistency of clinical management, and facilitate multiinstitutional research. We present a consensus statement to standardize MRI screening and reporting for individuals with elevated risk of pancreatic cancer.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Humanos , Detecção Precoce de Câncer , Carcinoma Ductal Pancreático/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/genética , Imageamento por Ressonância Magnética , Padrões de Referência , Neoplasias Pancreáticas
10.
Radiology ; 301(1): 144-151, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34342502

RESUMO

Background Dual-energy CT enterography (DECTE) has been shown to be useful in characterizing Crohn disease activity compared with clinical markers of inflammation but, to the knowledge of the authors, comparison has not been made with histopathologic specimens. Purpose To compare mucosal iodine density obtained at DECTE from Crohn disease-affected bowel with histopathologic specimens from surgically resected ileocolectomy bowel segments or terminal ileum colonoscopic biopsies in the same patients. Materials and Methods This was a retrospective study. Bowel segments in adults with Crohn disease who underwent DECTE from January 2017 to April 2019 within 90 days of ileocolectomy or colonoscopy were retrospectively evaluated with prototype software allowing the semiautomatic determination of inner hyperdense bowel wall (mucosal) mean iodine density, normalized to the aorta. Mean normalized iodine density and clinical activity indexes (Crohn Disease Activity Index [CDAI] and Harvey-Bradshaw Index [HBI]) were compared with histologic active inflammation grades by using two-tailed t tests. Receiver operating characteristic curves were generated for mean normalized iodine density, CDAI, and HBI to determine sensitivity, specificity, and accuracy. A P value less than .05 was considered to indicate statistical significance. Results The following 16 patients were evaluated (mean age, 41 years ± 14 [standard deviation]): 10 patients (five men, five women; mean age, 41 years ± 15) with 19 surgical resection specimens and six patients with terminal ileum colonoscopic mucosal biopsies (four men, two women; mean age, 43 years ± 14). Mean normalized iodine density was 16.5% ± 5.7 for bowel segments with no active inflammation (n = 8) and 34.7% ± 9.7 for segments with any active inflammation (n = 17; P < .001). A 20% mean normalized iodine density threshold had sensitivity, specificity, and accuracy of 17 of 17 (100%; 95% CI: 80.5, 100), six of eight (75%; 95% CI: 35, 97), and 23 of 25 (92%; 95% CI: 74, 99), respectively, for active inflammation. Clinical indexes were similar for patients with and without active inflammation at histopathologic analysis (CDAI score, 261 vs 251, respectively [P = .77]; HBI score, 7.8 vs 6.4, respectively [P = .36]). Conclusion Iodine density from dual-energy CT enterography may be used as a radiologic marker of Crohn disease activity as correlated with histopathologic analysis. © RSNA, 2021 See also the editorial by Ohliger in this issue.


Assuntos
Doença de Crohn/diagnóstico por imagem , Doença de Crohn/patologia , Inflamação/diagnóstico por imagem , Inflamação/patologia , Iodo/farmacocinética , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Biomarcadores , Meios de Contraste/farmacocinética , Doença de Crohn/complicações , Feminino , Humanos , Inflamação/etiologia , Intestinos/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
11.
J Am Coll Radiol ; 18(9): 1324-1331, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34004175

RESUMO

OBJECTIVE: To assess current practice patterns with respect to protocols used for incidental pancreatic cyst follow-up, management guidelines, and template reporting. METHODS: The Society of Abdominal Radiology Disease Focused Panel on intraductal pancreatic neoplasms distributed an anonymous 14-question survey to its members in June 2018 that focused on current utilization of incidental pancreatic cyst guidelines, protocols, and template reporting. RESULTS: Among the 1,390 email invitations, 323 responded, and 94.7% (306 of 323) completed all questions. Respondents were mainly radiologists (93.8%, 303 of 323) from academic institutions (74.7%, 227 of 304) in North America (93.7%, 286 of 305). Of respondents, 42.5% (136 of 320) preferred 2017 ACR recommendations, 17.8% (57 of 320) homegrown systems, 15.0% (48 of 320) Fukuoka guidelines, and 7.8% (25 of 320) American Gastroenterological Association guidelines. The majority (68.7%, 222 of 323) agreed or strongly agreed that developing a single international consensus recommendation for management was important, and most radiologists preferred to include them in reports (231 of 322, 71.7%); yet only half included recommendations in >75% of reports (161 of 321). MR cholangiopancreatography was the modality of choice for follow-up of <2.5 cm cysts. Intravenous contrast was routinely used by 69.7% (212 of 304). Standardized reporting templates were rarely used in practice (12.8% 39 of 306). CONCLUSIONS: Nearly 7 of 10 radiologists desire a unified international consensus recommendation for management of incidental cystic pancreatic lesions; ACR 2017 recommendations are most commonly used, followed by homegrown systems and Fukuoka guidelines. The majority of radiologists routinely use MR cholangiopancreatography with intravenous contrast for follow-up of incidental cystic lesions, but template reporting is rarely used.


Assuntos
Cisto Pancreático , Neoplasias Pancreáticas , Radiologia , Humanos , Achados Incidentais , Cisto Pancreático/diagnóstico por imagem , Cisto Pancreático/terapia , Radiografia Abdominal , Inquéritos e Questionários
12.
J Comput Assist Tomogr ; 45(2): 171-176, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33661155

RESUMO

OBJECTIVE: The objective of this study was to determine if dual-energy computed tomography enterography (DECTE)-obtained iodine density can predict medical management change or surgery in Crohn disease patients. METHODS: The most active-appearing bowel segment on DECTE in 21 Crohn disease patients was retrospectively interrogated with prototype software determining the percentage of bowel wall (I) in specified ranges. Patients were categorized into 3 groups after DECTE: (1) no management change, (2) outpatient medication change, and (3) inpatient admission or surgery. Crohn's disease activity index was calculated. Group 3's percentage iodine density of >3 mg/mL and Crohn's disease activity index were compared with group 1/2. Crohn's disease activity index and percentage iodine density of >2 mg/mL were compared for groups 2/3 versus group 1 patients. RESULTS: There were 5 group 1, 6 group 2, and 10 group 3 patients. Group 3 patients had higher frequency of iodine density >3 mg/mL (27%) compared with groups 1/2 patients (12.6%) (P < 0.05). Crohn's disease activity index was similar (P = 0.98). Groups 2/3 patients had 60.5% iodine density of >2 mg/mL, whereas group 1 patients had 31.7% iodine density of >2 mg/mL (P < 0.05). Crohn's disease activity index was similar (P = 0.12). CONCLUSIONS: Iodine density from DECTE may predict medical or surgical Crohn disease management.


Assuntos
Doença de Crohn/diagnóstico por imagem , Intestino Delgado/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Doença de Crohn/patologia , Feminino , Humanos , Intestino Delgado/patologia , Iodo , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos
13.
Eur J Radiol ; 136: 109537, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33454459

RESUMO

PURPOSE: To compare CT isocenter accuracy, patient dose, and scan time in adults imaged with and without use of a 3D camera. METHOD: 571 CT examinations utilizing a 3D camera for initial patient positioning (optional radiographer isocenter adjustment) and 504 examinations scanned without the camera between 10/1/2018 and 3/19/2019 were retrospectively identified. All exams were chest or abdominopelvic CTs. The isocenters of these exams were compared with the true isocenters defined as the manually delineated centroid of the body in the CT volume. The size specific dose estimate (SSDE) (mGy) of radiation dose obtained from departmental software for the 4 most common protocols on one CT scanner was compared before and after implementation of the 3D camera. The times required for the entire scan and just the topogram "scout" were compared with and without the 3D camera for noncontrast chest and abdominopelvic CT enterography protocols. 2-tailed t-tests and Mann-Whitney U tests were used (P < 0.05 indicated statistical significance). RESULTS: The deviation from true isocenter was 6.8 ±â€¯6.1 mm (P = 0.043) and 16.3 ±â€¯14.0 mm (P < 0.01) with and without the 3D camera, respectively (P < 0.01). CT radiographers accepted isocenter location without alteration in 93 % of examinations. Average SSDE savings with the 3D camera ranged 1.0-2.4 mGy (21-31 %) for the 4 most commonly performed protocols (p < 0.01). Median scout time savings was 32 s (Camera vs. No-Camera cohorts) (P < 0.01). Average noncontrast chest CT and CT enterography scan time savings were 19 s and 17 s with the 3D camera, respectively (P < 0.01). CONCLUSIONS: The 3D camera improved accuracy of patient positioning while reducing radiation dose and examination time. Implementation of a 3D camera helps standardize workflow in a busy clinical practice.


Assuntos
Redução da Medicação , Tomografia Computadorizada por Raios X , Adulto , Humanos , Posicionamento do Paciente , Doses de Radiação , Estudos Retrospectivos
14.
AJR Am J Roentgenol ; 217(2): 347-358, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32936014

RESUMO

Ileal pouch-anal anastomosis (IPAA) surgery is the reference standard surgical procedure for treatment of ulcerative colitis and most patients with familial adenomatous polyposis. This procedure allows preservation of fecal continence and gastrointestinal continuity. However, it is associated with a wide variety of complications, which often have nonspecific and overlapping clinical presentations, making imaging an important part of workup for pouch dysfunction. The purpose of this article is to propose structured reporting templates for MRI and water-soluble contrast enema (WSCE), based on our referral pouch center's experience, in patients who have undergone IPAA surgery. We review salient surgical technique, pouch anatomy, and imaging protocols, with an emphasis on a systematic search pattern for evaluation of ileal pouch complications using proposed structured reporting templates for MRI and WSCE.


Assuntos
Meios de Contraste , Enema/métodos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Proctocolectomia Restauradora , Colo/diagnóstico por imagem , Humanos , Reto/diagnóstico por imagem , Encaminhamento e Consulta
15.
Abdom Radiol (NY) ; 46(4): 1586-1606, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33185741

RESUMO

There have been many publications detailing imaging features of malignant transformation of intraductal papillary mucinous neoplasms (IPMN), management and recommendations for imaging follow-up of diagnosed or presumed IPMN. However, there is no consensus on several practical aspects of imaging IPMN that could serve as a clinical guide for radiologists and enable future data mining for research. These aspects include how to measure IPMN, define reporting terminology, standardize reporting and unify guidelines for surveillance. The Society of Abdominal Radiology (SAR) created multiple Disease-Focused Panels (DFP) comprised multidisciplinary panel members who focus on a particular disease, with the goal to develop ways for radiologists to improve patient care, education, and research. DFP members met to identify the current controversies and limitations of imaging pancreatic IPMN. This paper aims to provide a practical review of the key imaging characteristics of IPMN for trainees and practicing radiologists, to guide uniformity of performance and interpretation of surveillance imaging studies, and to improve communication with clinicians by providing a lexicon and reporting template based on the experience of the SAR-DFP panel members.


Assuntos
Neoplasias Intraductais Pancreáticas , Neoplasias Pancreáticas , Radiologia , Humanos , Pâncreas , Neoplasias Intraductais Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Radiografia Abdominal
16.
J Comput Assist Tomogr ; 44(5): 772-779, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32936579

RESUMO

OBJECTIVE: To create a map of iodine densities within affected segments of small-bowel Crohn disease (CD) derived from contrast-enhanced dual-energy computed tomography enterography (DECTE) studies. METHODS: Twenty CD patients imaged with intravenous contrast-enhanced DECTE between June 2016 and December 2017 were retrospectively identified. Ten patients without clinical evidence of CD and 8 normal-appearing jejunal segments in CD patients were controls. Using prototype software, 8 manual contours were drawn along the mucosa of affected segments. Relatively normal-appearing bowel was included at the edges. These contours served as a basis for iodine density calculation and 3-dimensional iodine density map rendering. Color-coded iodine densities allowed detection and quantification of the most and least dense portion of each segment and also permitted relative comparison between segments. RESULTS: The average iodine density per CD involved segment ranged 1.0 to 3.3 mg/mL, which differed significantly from normal ileum (P < 0.0001) and normal-appearing jejunum in patients with CD (P = 0.0009). Standard deviations ranged from 0.8 to 1.7 mg/mL, which differed significantly from normal ileum (P = 0.0039) and normal-appearing jejunum in patients with CD (P = 0.0056). The amplitude of the power spectrum ranged from 0.66 to 3.3 demonstrating patches of iodine rather than uniform distribution. This differed significantly from normal ileum (P = 0.0005) and normal-appearing jejunum in patients with CD (P = 0.0004). CONCLUSIONS: Heterogeneous CD activity and distribution can be displayed as iodine density maps created from DECTE.


Assuntos
Meios de Contraste/farmacocinética , Doença de Crohn/diagnóstico por imagem , Imageamento Tridimensional/métodos , Iodo/farmacocinética , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Feminino , Trato Gastrointestinal/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
18.
Abdom Radiol (NY) ; 45(9): 2663-2668, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32296895

RESUMO

PURPOSE: For more than half of Crohn's disease patients, strictures will cause bowel obstructions that require surgery within 10 years of their initial diagnosis. This study utilizes computed tomography imaging and clinical data obtained at the initial emergency room visit to create a prediction model for progression to surgery in Crohn's disease patients with acute small bowel obstructions. METHODS: A retrospective chart review was performed for patients who presented to the emergency room with an ICD-10 diagnosis for Crohn's disease and visit diagnosis of small bowel obstruction. Two expert abdominal radiologists evaluated the CT scans for bowel wall thickness, maximal and minimal luminal diameters, length of diseased segment, passage of oral contrast, evidence of penetrating disease, bowel wall hyperenhancement or stratification, presence of a comb sign, fat hypertrophy, and small bowel feces sign. The primary outcome was progression to surgery within 6 months of presentation. The secondary outcome was time to readmission. RESULTS: Forty patients met the inclusion criteria, with 78% receiving medical treatment alone and 22% undergoing surgery within 6 months of presentation to the emergency room. Multivariable analysis produced a model with an AUC of 92% (95% CI 0.82-1.00), 78% sensitivity, and 97% specificity, using gender, body mass index, and the radiographic features of segment length, penetrating disease, and bowel wall hyperenhancement. CONCLUSIONS: The model demonstrates that routine clinical and radiographic data from an emergency room visit can predict progression to surgery, and has the potential to risk stratify patients, guide management in the acute setting, and predict readmission.


Assuntos
Doença de Crohn , Obstrução Intestinal , Doença de Crohn/complicações , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/cirurgia , Humanos , Obstrução Intestinal/diagnóstico por imagem , Obstrução Intestinal/etiologia , Obstrução Intestinal/cirurgia , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/cirurgia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
19.
J Comput Assist Tomogr ; 44(2): 242-247, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32195803

RESUMO

OBJECTIVE: The objective of this study was to assess if bowel wall iodine density obtained from dual-source, dual-energy computed tomography enterography (DECTE) could be a biomarker of Crohn's disease activity. METHODS: Twenty-two patients with Crohn's disease imaged with DECTE from February 2016 to May 2018 were retrospectively identified by departmental report search. Iodine maps were created with commercial software (Syngovia). Iodine content was normalized to the aorta, and then manual dual-energy region-of-interest cursors were placed over the visibly assessed maximal and minimal iodine density within segments of involved as well as unaffected small bowel. The mixed Hounsfield unit value, maximum iodine density (Imax), and minimum iodine density (Imin) were recorded. The length of affected bowel demonstrating maximum disease activity as a percentage of overall involvement was subjectively assessed. A weighted iodine density (Iweighted) was calculated. The clinical assessment of disease activity using erythrocyte sedimentation rate, C-reactive protein, fecal calprotectin, colonoscopy/endoscopy, and surgery, if available, served as the reference standard. The Crohn's disease activity index was also used as a separate additional reference standard. RESULTS: Significant heterogeneity within the affected segments was present. The average Imax and Imin of affected bowel was 4.27 ± 1.11 (2.4-7.4) mg/mL and 2.71 ± 0.51 (2.2-3.9) mg/mL, respectively. Iodine density of normal-appearing small bowel was 1.40 ± 0.26 (0.9-1.9) mg/mL. The Imax and Imin of affected bowel differed significantly from normal bowel (P < 0.0001). Mixed Hounsfield unit (101.82 ± 27.5) also statistically differed (46.33 ± 19.62) (P < 0.0001). Using overall clinical assessment as the reference standard, all patients with Imin of greater than 2.6 mg/mL, Iweighted of greater than 3.3 mg/mL, or Imax of greater than 4.7 mg/mL had clinically active disease. Sixteen of 17 patients with Imin of greater than 2.2 mg/mL and 14/15 with Iweighted of greater than 3 mg/mL had clinically active disease. Using Crohn's disease activity index as the reference standard, all patients with Imin of greater than 2.7 mg/mL, Iweighted of greater than 3.6 mg/mL, or Imax of greater than 5.4 mg/mL had clinically active disease. The median effective dose was 4.64 ± 1.68 mSv (range, 2.03-8.12 mSv). CONCLUSIONS: Iodine density obtained from DECTE highlights regions of maximal activity within affected bowel segments. An iodine density of 2 mg/mL appears to be a threshold between normal bowel segments and those with active Crohn's disease. Iodine density measurement thresholds Imin of greater than 2.6 mg/mL, Iweighted of greater than 3.3 mg/mL, and Imax of greater than 4.7 mg/mL correlate with established clinical markers of disease activity, with Imin seemingly most useful in daily clinical practice.


Assuntos
Meios de Contraste , Doença de Crohn/diagnóstico por imagem , Intestinos/diagnóstico por imagem , Iodo , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Absorciometria de Fóton , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
20.
AJR Am J Roentgenol ; 212(3): 596-601, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30620679

RESUMO

OBJECTIVE: The objective of our study was to test for the possibility that published malignancy risks for side-branch intraductal papillary mucinous neoplasms (IPMNs) are overestimates, likely due to verification bias. MATERIALS AND METHODS: We tested for possible verification bias using simulation modeling techniques. First, in age-defined hypothetical cohorts of 10 million persons, we projected the frequency of pancreatic ductal adenocarcinoma (PDAC) arising from side-branch IPMNs over 5 years using published estimates of their prevalence (4.4%) and rate of malignant transformation (1.9%). Second, we projected the total number of PDAC cases in corresponding cohorts over the same time horizon using national cancer registry data. For each cohort, we determined whether the percentage of all PDAC cases that arose from side-branch IPMNs (i.e., side-branch IPMN-associated PDAC cases) was clinically plausible using an upper limit of 10% to define plausibility, as estimated from the literature. Model assumptions and parameter uncertainty were evaluated in sensitivity analysis. RESULTS: Across all cohorts, percentages of side-branch IPMN-associated PDACs greatly exceeded 10%. In the base case (mean age = 55.7 years), 80% of PDAC cases arose from side-branch IPMNs (7877/9786). In the oldest cohort evaluated (mean age = 75 years), this estimate was 76% (14,227/18,714). In a secondary analysis, we found that if an upper limit threshold of 10% for side-branch IPMN-associated PDAC was imposed, the model-predicted rate of malignancy for side-branch IPMNs would be less than 0.24% over a 5-year time horizon, substantially lower than most literature-based estimates. CONCLUSION: Our results suggest that reported malignancy risks associated with side-branch IPMNs are likely to be overestimates and imply the presence of verification bias.


Assuntos
Adenocarcinoma Papilar/patologia , Carcinoma Ductal Pancreático/patologia , Neoplasias Pancreáticas/patologia , Adenocarcinoma Papilar/epidemiologia , Viés , Carcinoma Ductal Pancreático/epidemiologia , Simulação por Computador , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/epidemiologia , Prevalência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA