Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Invasive Cardiol ; 33(5): E356-E364, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33932281

RESUMO

OBJECTIVES: Both balloon-expandable and self-expanding transcatheter aortic valves are used for transcatheter aortic valve implantation (TAVI). We compared procedural and clinical outcome variables of Sapien 3 and Evolut R/Pro in an all-comers collective. METHODS: In this single-center registry, patients were consecutively treated with the Sapien 3 from November 2014 to March 2017 (n = 129) and from April 2017 to December 2018 mainly (>95%) with the Evolut R/Pro (n = 124), due to a switch in the main TAVI supplier driven by hospital management. Data were retrospectively analyzed before and after the switch. RESULTS: One-year follow-up data were available for 122 (94%) of the Sapien and 112 (90%) of the Evolut patients. Baseline characteristics were comparable (EuroSCORE: Sapien 21.8 ± 0.9% vs Evolut 22.5 ± 0.8%; P=.20). Evolut implantation was associated with a higher radiation dose (Sapien 35770 ± 2345 mGy•cm² vs Evolut 85072 ± 8202 mGy•cm²; P<.001), more postimplantation balloon dilations (Sapien 17.1% vs Evolut 37.1%; P<.001), but similar procedure time (Sapien 75.2 ± 3.8 min vs Evolut 74.6 ± 3 min; P=.30). In-hospital mortality (Sapien 3.1% vs Evolut 4.0%; P=.70), all-cause mortality (Sapien 13.2% vs Evolut 15.3%; P=.70), all-stroke rate (Sapien 1.5% vs Evolut 6.5%; P=.05), and pacemaker implantation rate (Sapien 13.2% vs Evolut 18.5%; P=.30) were similar at 1 year. Permanent pacemaker rate was numerically higher in the first 6 months with Evolut (<6 months 26.7% vs >6 months 16%; P=.62); furthermore, radiation dose and balloon dilations also suggest a learning curve with Evolut. CONCLUSIONS: Switching from Sapien 3 to Evolut R/Pro was not associated with a difference regarding periprocedural or 1-year clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Am Heart J ; 234: 1-11, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33428901

RESUMO

BACKGROUND: In acute myocardial infarction complicated by cardiogenic shock the use of mechanical circulatory support devices remains controversial and data from randomized clinical trials are very limited. Extracorporeal life support (ECLS) - venoarterial extracorporeal membrane oxygenation - provides the strongest hemodynamic support in addition to oxygenation. However, despite increasing use it has not yet been properly investigated in randomized trials. Therefore, a prospective randomized adequately powered clinical trial is warranted. STUDY DESIGN: The ECLS-SHOCK trial is a 420-patient controlled, international, multicenter, randomized, open-label trial. It is designed to compare whether treatment with ECLS in addition to early revascularization with percutaneous coronary intervention or alternatively coronary artery bypass grafting and optimal medical treatment is beneficial in comparison to no-ECLS in patients with severe infarct-related cardiogenic shock. Patients will be randomized in a 1:1 fashion to one of the two treatment arms. The primary efficacy endpoint of ECLS-SHOCK is 30-day mortality. Secondary outcome measures such as hemodynamic, laboratory, and clinical parameters will serve as surrogate endpoints for prognosis. Furthermore, a longer follow-up at 6 and 12 months will be performed including quality of life assessment. Safety endpoints include peripheral ischemic vascular complications, bleeding and stroke. CONCLUSIONS: The ECLS-SHOCK trial will address essential questions of efficacy and safety of ECLS in addition to early revascularization in acute myocardial infarction complicated by cardiogenic shock.


Assuntos
Oxigenação por Membrana Extracorpórea , Infarto do Miocárdio/terapia , Revascularização Miocárdica/métodos , Ponte de Artéria Coronária/métodos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/métodos , Fibrinolíticos/uso terapêutico , Humanos , Infarto do Miocárdio/complicações , Infarto do Miocárdio/mortalidade , Prognóstico , Estudos Prospectivos , Qualidade de Vida , Tamanho da Amostra , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade
3.
EuroIntervention ; 16(17): 1447-1454, 2021 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-33074154

RESUMO

AIMS: Failure of transcatheter mitral valve repair (fTMVR) therapy has a decisive prognostic influence, and complex retreatment is of higher risk. The aim of this analysis was to evaluate the survival outcome following percutaneous procedures and surgery after unsuccessful TMVR interventions for different aetiologies. METHODS AND RESULTS: Of 824 consecutive patients who had been treated with the MitraClip device at our institution, between September 2009 and May 2019, 63 (7.6%) symptomatic patients with therapy failure and persistent or recurrent mitral regurgitation (MR) underwent reinterventions. An outcome analysis for primary (PMR) and secondary mitral regurgitation (SMR) and subsequent percutaneous versus surgical treatment was carried out. MitraClip reinterventions were performed in 36 patients (57.1%; n=26 SMR, n=10 PMR), while 27 (42.9%; n=13 SMR, n=14 PMR) underwent open heart surgery. Surgical patients with PMR showed lower mortality than patients with SMR (p<0.0001) and ReClip patients with PMR (p=0.073). Atrial fibrillation (HR 2.915, 95% CI: [1.311, 6.480]), prior open heart surgery (2.820 [1.215, 6.544]) and chronic obstructive pulmonary disease (2.506 [1.099, 5.714]) increased the risk of death. The level of post-interventional MR had no relevant impact on survival. CONCLUSIONS: We conclude that, after SMR and failed TMVR, reclipping is an appropriate treatment option for symptomatic patients. For PMR patients, surgery must be favoured over a reclipping procedure. However, patients with atrial fibrillation, prior open heart surgery and chronic obstructive pulmonary disease are at risk of reduced survival after reinterventions.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
4.
Circulation ; 143(2): 104-116, 2021 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-32975133

RESUMO

BACKGROUND: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR. METHODS: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate. RESULTS: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76-996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510-1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR (P<0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients (P=0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P<0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P=0.02). The rates of Mitral Valve Academic Research Consortium-defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P=0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74-12.56; P=0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88-21.53; P<0.001) were both independently associated with repeat mitral valve replacement. CONCLUSIONS: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.


Assuntos
Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas/normas , Valva Mitral/cirurgia , Sistema de Registros , Reoperação/normas , Substituição da Valva Aórtica Transcateter/normas , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Próteses Valvulares Cardíacas/tendências , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/tendências , Humanos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Reoperação/tendências , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/tendências
5.
Cardiol J ; 25(4): 459-469, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29512092

RESUMO

BACKGROUND: Suboptimal implantation of everolimus-eluting bioresorbable vascular scaffolds (EE-BVS) leading to strut malapposition and lack of neointima coverage has been hypothesized to be linked to late BVS-thrombosis. Optical coherence tomography (OCT) allows assessing subtle differences in BVS-healing. We aimed to link 6-months OCT-data on EE-BVS coverage and malapposition to implantation technique and clinical outcome. METHODS: Twenty-nine consecutive EE-BVS-patients were included. EE-BVS-implantation was guided by angiography in the first 17 patients (group 1). Vessel sizing prior to implantation and implantation result was assessed by OCT in the 12 following patients (group 2). EE-BVS-implantation was performed in both groups with adequate lesion preparation, sizing and systematic high-pressure post-dilatation. All patients received 6-months invasive control including OCT-analysis and clinical follow-up for 2 years. RESULTS: The rate of uncovered struts was group 1: 10.8 ± 10.0%; group 2: 10.6 ± 8.2%, p = 0.934. Target lesion failure due to BVS-thrombosis occurred in 2/17 patients at 9 and 18 months (11.8%, group 1), and no patients in group 2 (p = 0.218). CONCLUSIONS: Optical coherence tomography analysis at 6-months following EE-BVS-implantation finds almost 90% of struts to be covered. No difference between OCT vs. angiography-guided EE-BVS-implantation was observed. OCT at 6-months was not able to predict late BVS-thrombosis of EE-BVS.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Everolimo/farmacologia , Cirurgia Assistida por Computador/métodos , Alicerces Teciduais , Tomografia de Coerência Óptica/métodos , Implantes Absorvíveis , Doença da Artéria Coronariana/diagnóstico , Feminino , Seguimentos , Humanos , Imunossupressores/farmacologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 89(1): 154-158, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27762092

RESUMO

AIMS: Aims of this case-series were to assess the feasibility of cerebral protection devices in interventional left atrial appendage occlusion (iLAAO) procedures and to yield insight into the pathomorphological correlate of early, procedural cerebral embolization during iLAAO. METHODS AND RESULTS: Five consecutive patients underwent iLLO flanked by the Sentinel CPS® (Claret Medical, Inc., Santa Rosa, CA) cerebral protection system. Placement and recapture of the Sentinel® device as well as the iLAAO were successful and safe in all cases. Histomorphometric analysis of the collected filters showed embolized debris in all patients. Acute thrombus was found in three patients, organizing thrombus in four. Interestingly, two patients had endocardial or myocardial tissue in their filters. CONCLUSIONS: Cerebral protection during iLAAO with the Sentinel CPS® device is feasible. Furthermore, this dataset identifies the formation and embolization of thrombus and cardiac tissue as emboligeneic sources and potential future targets to reduce procedural complications. © 2016 Wiley Periodicals, Inc.


Assuntos
Apêndice Atrial , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Dispositivos de Proteção Embólica , Embolia Intracraniana/prevenção & controle , Acidente Vascular Cerebral/prevenção & controle , Trombose/prevenção & controle , Idoso , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Biópsia , Cateterismo Cardíaco/efeitos adversos , Estudos de Viabilidade , Humanos , Embolia Intracraniana/diagnóstico , Embolia Intracraniana/etiologia , Pessoa de Meia-Idade , Miocárdio/patologia , Projetos Piloto , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Trombose/diagnóstico , Trombose/etiologia , Resultado do Tratamento
7.
Eur Heart J Acute Cardiovasc Care ; 4(6): 577-8, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25225188

RESUMO

Concurring left ventricular dysfunction, pulmonary edema and febrile temperature in otherwise healthy young individuals often constitutes the clinical presentation of a fulminant myocarditis. Nevertheless, the pheochromocytoma crisis (PCC) can mimic this very cluster of symptoms, camouflaging its disclosure. We describe a dramatic case of pheochromocytoma crisis mimicking fulminant myocarditis.


Assuntos
Neoplasias das Glândulas Suprarrenais/diagnóstico , Miocardite/diagnóstico , Feocromocitoma/diagnóstico , Neoplasias das Glândulas Suprarrenais/patologia , Glândulas Suprarrenais/patologia , Adulto , Diagnóstico Diferencial , Feminino , Humanos , Feocromocitoma/patologia
8.
EuroIntervention ; 9(5): 643-7, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23482326

RESUMO

The presence of mitral regurgitation (MR) in patients with heart failure represents an independent predictor of mortality. Until now, the standard therapy for severe MR has been cardiac surgery in order to perform mitral valve replacement or mitral valve repair. With the introduction of the MitraClip® system (Abbott Vascular - Structural Heart, Menlo Park, CA, USA) in 2008, there is now an alternative percutaneous treatment option available for high-risk patients. We report on an 84-year-old male patient who was admitted to the emergency room with increasing shortness of breath due to severe functional MR, at stage NYHA III. In the following days the patient developed cardiogenic shock due to failure of the diuretic medication. The case first described here demonstrates an alternative transseptal route of access via a direct atrial puncture of the RA in a patient with absent inferior vena cava. This approach was successfully used to perform a MitraClip® procedure in this patient with functional MR and cardiogenic shock. It was possible to treat mitral regurgitation and the consecutive cardiogenic shock by implanting two MitraClips®.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Choque Cardiogênico/cirurgia , Veia Cava Inferior/cirurgia , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Insuficiência da Valva Mitral/diagnóstico , Choque Cardiogênico/induzido quimicamente , Choque Cardiogênico/diagnóstico , Resultado do Tratamento
9.
Ann Thorac Surg ; 94(6): 2115-8, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23176928

RESUMO

Valve-in-valve implantation for degenerated surgical bioprosthetic valves is becoming an increasingly accepted approach in selected high-risk patients. In the past, valve-in-valve implantations have been mainly performed in aortic position and only rarely in mitral position. We describe the case of an 81-year-old female patient with severe mitral regurgitation of a degenerated Carpentier-Edwards biological prosthesis treated by transfemoral and transseptal implantation of a SAPIEN-XT valve.


Assuntos
Bioprótese , Cateterismo Cardíaco/métodos , Cateterismo Periférico/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Reoperação/métodos , Idoso de 80 Anos ou mais , Ecocardiografia Transesofagiana , Feminino , Artéria Femoral , Humanos , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Desenho de Prótese , Falha de Prótese , Transplante Heterólogo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA