Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Int J Hyperthermia ; 40(1): 2205071, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37127281

RESUMO

OBJECTIVES: To compare metal artifacts and evaluation of metal artifact reduction algorithms during probe positioning in computed tomography (CT)-guided microwave ablation (MWA), cryoablation (CRYO), and radiofrequency ablation (RFA). MATERIALS AND METHODS: Using CT guidance, individual MWA, CRYO, and RFA ablation probes were placed into the livers of 15 pigs. CT imaging was then performed to determine the probe's position within the test subject's liver. Filtered back projection (B30f) and iterative reconstructions (I30-1) were both used with and without dedicated iterative metal artifact reduction (iMAR) to generate images from the initial data sets. Semi-automatic segmentation-based quantitative evaluation was conducted to estimate artifact percentage within the liver, while qualitative evaluation of metal artifact extent and overall image quality was performed by two observers using a 5-point Likert scale: 1-none, 2-mild, 3-moderate, 4-severe, 5-non-diagnostic. RESULTS: Among MWA, RFA, and CRYO, compared with non-iMAR in B30f reconstruction, the largest extent of artifact volume percentages were observed for CRYO (11.5-17.9%), followed by MWA (4.7-6.6%) and lastly in RFA (5.5-6.2%). iMAR significantly reduces metal artifacts for CRYO and MWA quantitatively (p = 0.0020; p = 0.0036, respectively) and qualitatively (p = 0.0001, p = 0.0005), but not for RFA. No significant reduction in metal artifact percentage was seen after applying iterative reconstructions (p > 0.05). Noise, contrast-to-noise-ratio, or overall image quality did not differ between probe types, irrespective of the application of iterative reconstruction and iMAR. CONCLUSION: A dedicated metal artifact algorithm may decrease metal artifacts and improves image quality significantly for MWA and CRYO probes. Their application alongside with dedicated metal artifact algorithm should be considered during CT-guided positioning.


Assuntos
Artefatos , Criocirurgia , Ablação por Radiofrequência , Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Imageamento de Micro-Ondas , Suínos , Animais
2.
PLoS One ; 15(2): e0228578, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32040496

RESUMO

OBJECTIVES: To compare image quality and metal artifact reduction between virtual monochromatic spectral imaging (VMSI), linearly blended dual-energy (DE) and single-energy (SE) images, each with and without dedicated iterative metal artifact reduction (iMAR) for CT-guided biopsy. MATERIALS AND METHODS: A biopsy trocar was positioned in the liver of six pigs. DE (Sn140/100kVp) and SE (120kVp/200mAs) acquisitions were performed with equivalent dose. From dual-energy datasets DE Q30-3 images and VMSI between 40-180 keV in steps of 20 keV were generated. From SE datasets I30-3 images were reconstructed. All images were reconstructed with and without iMAR. Objective image quality was analyzed applying density measurements at standardized positions (e.g. trocar tip and liver parenchyma adjacent to the trocar tip) and semi-automated threshold based segmentation. Subjective image quality was performed using semi-quantitative scores. Analyses were performed by two observers. RESULTS: At the trocar tip quantitative image analysis revealed significant difference in CT numbers between reconstructions with iMAR compared to reconstructions without iMAR for VMSI at lower keV levels (80 and 100 keV; p = 0.03) and DE (p = 0.03). For liver parenchyma CT numbers were significantly higher in VMSI at high keV compared to low keV (p≤0.01). VMSI at high keV also showed higher CT numbers compared to DE and SE images, though not the level of statistical significance. The best signal-to-noise ratio for VMSI was at 80 keV and comparable to DE and SE. Noise was lowest at 80 keV and lower than in DE and SE. Subjective image quality was best with VMSI at 80 keV regardless of the application of iMAR. iMAR significantly improved image quality at levels of 140 keV and 160 keV. Interreader-agreement was good for quantitative and qualitative analysis. CONCLUSION: iMAR improved image quality in all settings. VMSI with iMAR provided metal artifact reduction and better image quality at 80 keV and thus could improve the accurate positioning in CT-guided needle biopsy. In comparison, DE imaging did not improve image quality compared to SE.


Assuntos
Biópsia por Agulha , Processamento de Imagem Assistida por Computador/métodos , Biópsia Guiada por Imagem , Fígado/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Algoritmos , Animais , Artefatos , Variações Dependentes do Observador , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Razão Sinal-Ruído , Suínos , Veia Cava Inferior/diagnóstico por imagem
3.
Phys Med Biol ; 59(23): 7229-44, 2014 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-25383509

RESUMO

In clinical ion beam therapy, protons as well as heavier ions such as carbon are used for treatment. For protons, ß(+)-emitters are only induced by fragmentation reactions in the target (target fragmentation), whereas for heavy ions, they are additionally induced by fragmentations of the projectile (further referred to as autoactivation). An approach utilizing these processes for treatment verification, by comparing measured Positron Emission Tomography (PET) data to predictions from Monte Carlo simulations, has already been clinically implemented. For an accurate simulation, it is important to consider the biological washout of ß(+)-emitters due to vital functions. To date, mathematical expressions for washout have mainly been determined by using radioactive beams of (10)C- and (11)C-ions, both ß(+)-emitters, to enhance the counting statistics in the irradiated area. Still, the question of how the choice of projectile (autoactivating or non-autoactivating) influences the washout coefficients, has not been addressed. In this context, an experiment was carried out at the Heidelberg Ion Beam Therapy Center with the purpose of directly comparing irradiation-induced biological washout coefficients in mice for protons and (12)C-ions. To this aim, mice were irradiated in the brain region with protons and (12)C-ions and measured after irradiation with a PET/CT scanner (Siemens Biograph mCT). After an appropriate waiting time, the mice were sacrificed, then irradiated and measured again under similar conditions. The resulting data were processed and fitted numerically to deduce the main washout parameters. Despite the very low PET counting statistics, a consistent difference could be identified between (12)C-ion and proton irradiated mice, with the (12)C data being described best by a two component fit with a combined medium and slow washout fraction of 0.50 ± 0.05 and the proton mice data being described best by a one component fit with only one (slow) washout fraction of 0.73 ± 0.06.


Assuntos
Encéfalo/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Terapia com Prótons , Algoritmos , Animais , Partículas beta , Encéfalo/efeitos da radiação , Radioisótopos de Carbono/farmacocinética , Meia-Vida , Taxa de Depuração Metabólica , Camundongos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA