Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Exp Gerontol ; 96: 63-67, 2017 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-28602957

RESUMO

BACKGROUND: Mitochondrial quality control (MQC) is crucial for maintaining mitochondrial fitness. We investigated MQC signaling in muscle of old hip-fractured patients. METHODS: Twenty-three patients, enrolled in the Sarcopenia in HIp FracTure (SHIFT) study, were categorized into old (OL; n=8) and very old groups (VOL; n=15) using 85years as the cut-off. The expression of a set of MQC signaling proteins was assayed in vastus lateralis muscle biopsies. RESULTS: The content of lysosome-associated membrane protein 2, microtubule-associated protein 1 light chain 3B, optic atrophy protein 1, fission protein 1 (Fis1), peroxisome proliferator-activated receptor-γ coactivator-1α, and forkhead box O3 was unvaried between groups. Conversely, the protein expression of mitofusin 2 (Mfn2) as well as the fusion index (Mfn2/Fis1) was increased in VOL patients. CONCLUSIONS: Muscle mitochondrial dynamics appear to be shifted toward fusion in very advanced age. Whether this phenomenon represents an adaptation to cope with age-dependent mitochondrial dysfunction warrants further investigation.


Assuntos
Fraturas do Quadril/fisiopatologia , Mitocôndrias Musculares/fisiologia , Dinâmica Mitocondrial/fisiologia , Sarcopenia/fisiopatologia , Fatores Etários , Idoso de 80 Anos ou mais , Feminino , Proteína Forkhead Box O3/metabolismo , Humanos , Proteína 2 de Membrana Associada ao Lisossomo/metabolismo , Masculino , Proteínas Associadas aos Microtúbulos/metabolismo , Proteínas Musculares/metabolismo , Transdução de Sinais/fisiologia
2.
World J Orthop ; 8(2): 156-162, 2017 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-28251066

RESUMO

AIM: To report the clinical and radiographic results of titanium elastic nail (TEN) in diaphyseal femoral fractures of children below age of six years. METHODS: A retrospective analysis of 27 diaphyseal femoral fractures in children younger than six years treated with TEN between 2005 and 2015 was conducted. Patients were immobilized in a cast for 5 wk and the nails were removed from 6 to 12 wk after surgery. Twenty-four cases were clinically and radiographically re-evaluated using the Flynn's scoring criteria, focusing on: Limb length discrepancy, rotational deformity, angulation, hip and knee range of motion (ROM), functional status, complications, and parent's satisfaction. RESULTS: Sixteen males and eight females with a mean age of 3.2 years at the time of treatment were re-evaluated at an average follow-up of 58.9 mo. No cases of delayed union were observed. The mean limb lengthening was 0.3 cm. Four cases experienced limb lengthening greater than 1 cm and always minor than 2 cm. Twelve point five percent of the cases showed an angulation < 10°. Complete functional recovery (hip and knee ROM, ability to run and jump on the operated limb) occurred in 95.7% of cases. Complications included two cases of superficial infection of the TEN entry point, one case of refracture following a new trauma, and one TEN mobilization. According to the Flynn's scoring criteria, excellent results were obtained in 79.2% of patients and satisfactory results in the remaining 20.8%, with an average parent's satisfaction level of 9.1/10. CONCLUSION: TEN is as a safe, mini-invasive and surgeon-friendly technique and, considering specific inclusion criteria, it represents a useful and efficacy option for the treatment of diaphyseal femoral fractures even in patients younger than six years of age.

3.
Exp Gerontol ; 80: 1-5, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27064052

RESUMO

BACKGROUND: Sarcopenia has been proposed as a potentially amenable factor impacting the clinical outcomes of hip-fractured elderly. The identification of specific biological targets is therefore crucial to developing pharmacological interventions against age-related muscle wasting. The present work reports promising preliminary data on the association between alterations of myocyte quality control (MQC) signaling and sarcopenia in old patients with hip fracture. METHODS: Twenty-five elderly hip-fractured patients (20 women and 5 men; mean age 84.9±1.65years) were enrolled as part of the Sarcopenia in HIp FracTure (SHIFT) study. Intraoperative biopsies of the vastus lateralis muscle were obtained and assayed for the expression of a set of MQC signaling proteins. The presence of sarcopenia was established according to the European Working Group on Sarcopenia in Older People (EWGSOP) criteria, with bioelectrical impedance analysis used for fat-free mass estimation. RESULTS: Sarcopenia was identified in 10 patients (40%). Protein expression of the mitochondrial fusion factor mitofusin (Mfn) 2 and the autophagy mediator microtubule-associated protein 1 light chain 3B (LC3B) was significantly lower in patients with sarcopenia compared with non-sarcopenic controls. No differences between groups were observed for Mfn1, optic atrophy protein 1 (OPA1), fission protein 1 (Fis1), and the master regulator of mitochondrial biogenesis peroxisome proliferator-activated receptor-γ coactivator-1α (PGC-1α). CONCLUSION: Data from this exploratory study show that a reduced expression of the mitochondrial fusion factor Mfn2 and the autophagy mediator LC3B is associated with sarcopenia in old hip-fractured patients. Future larger-scale studies are needed to corroborate these preliminary findings and determine whether MQC pathways may be targeted to improve muscle health and promote functional recovery in old patients with hip fracture.


Assuntos
GTP Fosfo-Hidrolases/metabolismo , Fraturas do Quadril/fisiopatologia , Proteínas Associadas aos Microtúbulos/metabolismo , Proteínas Mitocondriais/metabolismo , Sarcopenia/metabolismo , Transdução de Sinais , Idoso de 80 Anos ou mais , Atrofia , Autofagia , Feminino , Humanos , Itália , Masculino , Proteínas de Membrana/metabolismo , Dinâmica Mitocondrial , Proteínas de Transporte da Membrana Mitocondrial/metabolismo , Músculos/fisiopatologia , Biogênese de Organelas , Coativador 1-alfa do Receptor gama Ativado por Proliferador de Peroxissomo/metabolismo , Sarcopenia/patologia
4.
Musculoskelet Surg ; 98(3): 179-87, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25269758

RESUMO

The purpose of our study was that to systematically review the fixation techniques for the ACL reconstruction and associated clinical outcomes at the early follow-up. Systematic search on three electronic databases (Cochrane register, Medline and Embase) of fixation devices used for primary ACL reconstruction with doubled semitendinosus and gracilis and bone-patellar tendon-bone autografts in randomized clinical trials of level I and II of evidence published from January 2001 to December 2011. Therapeutic studies collected were with a minimum 12-month follow-up, and the clinical outcomes were evaluated by at least one of International Knee Documentation Committee, Lysholm and Tegner functional scales and at least one of the following knee stability tests: arthrometric AP tibial translation, Lachman test and pivot-shift test. Nineteen articles met the inclusion criteria. At the femoral side cross-pin, metallic interference screw, bioabsorbable interference screw, and suspensory device were used in 32.3, 27.3, 24.8, 15.5% of patients, respectively. At the tibial side fixation was achieved with metallic interference screw, bioabsorbable interference screw, screw and plastic sheath, screw post and cross-pin in 38.7, 31, 15.7, 12.8, and 1.7% of patients, respectively. Side-to-side anterior-posterior tibial translation was 1.9 ± 0.9, 1.5 ± 0.9, 1.5 ± 0.8, 2.2 ± 0.4 mm for metallic interference screw, bioabsorbable screw, cross-pin and suspensory device, respectively. At least two-third of all the patients achieved good-to-excellent clinical outcomes. Rate of failure was 6.1, 3.3, 1.7 and 1.2% for bioabsorbable interference screw, metallic interference screw, cross-pin and suspensory device, respectively. Clinical outcomes are good to excellent in almost two-third of the patients but several pitfalls that affect the current fixation techniques as graft tensioning such as graft-tunnel motion are still unaddressed.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/métodos , Reconstrução do Ligamento Cruzado Anterior/instrumentação , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto
5.
Joints ; 2(3): 102-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25606552

RESUMO

PURPOSE: the aim of the present study was to evaluate the clinical outcome of the treatment of osteochondritis dissecans (OCD) of the knee with a type-I collagen-hydroxyapatite nanostructural biomimetic osteochondral scaffold. METHODS: twenty-three patients affected by symptomatic knee OCD of the femoral condyles, grade 3 or 4 of the International Cartilage Repair Society (ICRS) scale, underwent biomimetic scaffold implantation. The site of the defect was the medial femoral condyle in 14 patients, whereas in 9 patients the lateral femoral condyle was involved. The average size of the defects was 3.5±1.43 cm(2). All patients were clinically evaluated using the ICRS subjective score, the IKDC objective score, the EQ-VAS and the Tegner Activity Score. Minimum follow-up was two years. MRI was performed at 12 and 24 months after surgery and then every 12 months thereafter. RESULTS: the ICRS subjective score improved from the baseline value of 50.93±20.6 to 76.44±18.03 at the 12 months (p<0.0005) and 82.23± 17.36 at the two-year follow-up (p<0.0005). The IKDC objective score confirmed the results. The EQ-VAS showed a significant improvement from 3.15±1.09 to 8.15±1.04 (p<0.0005) at two years of follow-up. The Tegner Activity Score improvement was statistically significant (p<0.0005). CONCLUSIONS: biomimetic scaffold implantation was a good procedure for treating grade 3 and 4 OCD, in which other classic techniques are burdened by different limitations. This open one-step surgery gave promising stable results at short-term follow-up. LEVEL OF EVIDENCE: Level IV, therapeutic case series.

6.
Arch Phys Med Rehabil ; 94(6): 1126-31, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23154135

RESUMO

OBJECTIVES: To assess the interobserver concordance of the joint line tenderness (JLT) and McMurray tests, and to determine their diagnostic efficiency for the detection of meniscal lesions. DESIGN: Prospective observational study. SETTING: Orthopedics outpatient clinic, university hospital. PARTICIPANTS: Patients (N=60) with suspected nonacute meniscal lesions who underwent knee arthroscopy. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Patients were examined by 3 independent observers with graded levels of experience (>10y, 3y, and 4mo of practice). The interobserver concordance was assessed by Cohen-Fleiss κ statistics. Accuracy, negative and positive predictive values for prevalence 10% to 90%, positive (LR+) and negative (LR-) likelihood ratios, and the Bayesian posttest probability with a positive or negative result were also determined. The diagnostic value of the 2 tests combined was assessed by logistic regression. Arthroscopy was used as the reference test. RESULTS: No interobserver concordance was determined for the JLT. The McMurray test showed higher interobserver concordance, which improved when judgments by the less experienced examiner were discarded. The whole series studied by the "best" examiner (experienced orthopedist) provided the following values: (1) JLT: sensitivity, 62.9%; specificity, 50%; LR+, 1.26; LR-, .74; (2) McMurray: sensitivity, 34.3%; specificity, 86.4%; LR+, 2.52; LR-, .76. The combination of the 2 tests did not offer advantages over the McMurray alone. CONCLUSIONS: The JLT alone is of little clinical usefulness. A negative McMurray test does not modify the pretest probability of a meniscal lesion, while a positive result has a fair predictive value. Hence, in a patient with a suspected meniscal lesion, a positive McMurray test indicates that arthroscopy should be performed. In case of a negative result, further examinations, including imaging, are needed.


Assuntos
Avaliação da Deficiência , Traumatismos do Joelho/diagnóstico , Meniscos Tibiais/patologia , Adulto , Artroscopia , Teorema de Bayes , Diagnóstico Diferencial , Feminino , Humanos , Traumatismos do Joelho/patologia , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA