Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 85(2): 926-935, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32936490

RESUMO

PURPOSE: Because of short signal lifetimes and respiratory motion, 3D lung MRI is still challenging today. Zero-TE (ZTE) pulse sequences offer promising solutions as they overcome the issue of short T2∗ . Nevertheless, as they rely on continuous readout gradients, the trajectories they follow in k-space are not adapted to retrospective gating and inferred motion correction. THEORY AND METHODS: We propose AZTEK (adaptive ZTE k-space trajectories), a set of 3D radial trajectories featuring three tuning parameters, to adapt the acquisition to any moving organ while keeping seamless transitions between consecutive spokes. Standard ZTE and AZTEK trajectories were compared for static and moving phantom acquisitions as well as for human thoracic imaging performed on 3 volunteers (1 healthy and 2 patients with lung cancer). RESULTS: For the static phantom, we observe comparable image qualities with standard and AZTEK trajectories. For the moving phantom, spatially coherent undersampling artifacts observed on gated images with the standard trajectory are alleviated with AZTEK. The same improvement in image quality is obtained in human, so details are more delineated in the lung with the use of the adaptive trajectory. CONCLUSION: The AZTEK technique opens the possibility for 3D dynamic ZTE lung imaging with retrospective gating. It enables us to uniformly sample the k-space for any arbitrary respiratory motion gate, while preserving static image quality, improving dynamic image quality and guaranteeing continuous readout gradient transitions between spokes, which makes it appropriate to ZTE.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Artefatos , Humanos , Imagens de Fantasmas , Estudos Retrospectivos
2.
Phys Med Biol ; 63(18): 185002, 2018 09 10.
Artigo em Inglês | MEDLINE | ID: mdl-30106008

RESUMO

Respiratory motion causes misalignments between positron emission tomography (PET) and magnetic resonance (MR)-derived attenuation maps (µ-maps) in addition to artifacts on both PET and MR images in simultaneous PET/MRI for organs such as liver that can experience motion of several centimeters. To address this problem, we developed an efficient MR-based attenuation correction (MRAC) method to generate phase-matched µ-maps for quiescent period PET (PETQ) in abdominal PET/MRI. MRAC data was acquired with CIRcular Cartesian UnderSampling (CIRCUS) sampling during 100 s in free-breathing as an accelerated data acquisition strategy for phase-matched MRAC (MRACPM-CIRCUS). For comparison, MRAC data with raster (Default) k-space sampling was also acquired during 100 s in free-breathing (MRACPM-Default), and used to evaluate MRACPM-CIRCUS as well as un-matched MRAC (MRACUM) that was un-gated. We purposefully oversampled the MRACPM data to ensure we had enough information to capture all respiratory phases to make this comparison as robust as possible. The proposed MRACPM-CIRCUS was evaluated in 17 patients with 68Ga-DOTA-TOC PET/MRI exams, suspected of having neuroendocrine tumors or liver metastases. Effects of CIRCUS sampling for accelerating a data acquisition were evaluated by simulating the data acquisition time retrospectively in increments of 5 s. Effects of MRACPM-CIRCUS on PETQ were evaluated using uptake differences in the liver lesions (n = 35), compared to PETQ with MRACPM-Default and MRACUM. A Wilcoxon signed-rank test was performed to compare lesion uptakes between the MRAC methods. MRACPM-CIRCUS showed higher image quality compared to MRACPM-Default for the same acquisition times, demonstrating that a data acquisition time of 30 s was reasonable to achieve phase-matched µ-maps. Lesion update differences between MRACPM-CIRCUS (30 s) versus MRACPM-Default (reference, 100 s) were 0.1% ± 1.4% (range of -2.7% to 3.2%) and not significant (P > .05); while, the differences between MRACUM versus MRACPM-Default were 0.6% ± 11.4% with a large variation (range of -37% to 20%) and significant (P < .05). In conclusion, we demonstrated that a data acquisition of 30 s achieved phase-matched µ-maps when using specialized CIRCUS data sampling and phase-matched µ-maps improved PETQ quantification significantly.


Assuntos
Abdome/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Respiração
3.
Magn Reson Med ; 75(1): 107-14, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25639956

RESUMO

PURPOSE: To investigate proton density (PD)-weighted zero TE (ZT) imaging for morphological depiction and segmentation of cranial bone structures. METHODS: A rotating ultra-fast imaging sequence (RUFIS) type ZT pulse sequence was developed and optimized for 1) efficient capture of short T2 bone signals and 2) flat PD response for soft-tissues. An inverse logarithmic image scaling (i.e., -log(image)) was used to highlight bone and differentiate it from surrounding soft-tissue and air. Furthermore, a histogram-based bias-correction method was developed for subsequent threshold-based air, soft-tissue, and bone segmentation. RESULTS: PD-weighted ZT imaging in combination with an inverse logarithmic scaling was found to provide excellent depiction of cranial bone structures. In combination with bias correction, also excellent segmentation results were achieved. A two-dimensional histogram analysis demonstrates a strong, approximately linear correlation between inverse log-scaled ZT and low-dose CT for Hounsfield units (HU) between -300 HU and 1,500 HU (corresponding to soft-tissue and bone). CONCLUSIONS: PD-weighted ZT imaging provides robust and efficient depiction of bone structures in the head, with an excellent contrast between air, soft-tissue, and bone. Besides structural bone imaging, the presented method is expected to be of relevance for attenuation correction in positron emission tomography (PET)/MR and MR-based radiation therapy planning.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Crânio/anatomia & histologia , Humanos , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA