Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Biomed Microdevices ; 21(4): 85, 2019 08 27.
Artigo em Inglês | MEDLINE | ID: mdl-31451947

RESUMO

Advances in microfabrication allow for highly sensitive calorimeters with dramatically reduced volume, decreased response time and increased energy resolution. These calorimeters hold the potential for designs of ELISA platforms competitive with fluorescent and chemiluminescent technologies. We have developed a new assay platform using conventional ELISA reagents to produce a thermal signal quantifiable using calorimetry. Our optimized micromachined calorimeters have nL reaction volumes and a minimum detectable power of 375 pW/Hz1/2. We demonstrate rapid quantification in a model system of trastuzumab, a humanized monoclonal antibody used in the treatment of HER2 overexpressing breast cancers, in human serum using a HER2 peptide mimetic. Trastuzumab concentration and reaction time constant correlated well (R2 = 0.954) and can be used to determine trastuzumab concentrations. The limit of detection for the ThermometricELISA (TELISA) was 10 µg/ml trastuzumab in human serum. TELISA allows for a simple readout, reduction in assay time, sample and reagent volumes and has the potential to become a point of care multiplexed platform technology.


Assuntos
Calorimetria/instrumentação , Ensaio de Imunoadsorção Enzimática/instrumentação , Microtecnologia/instrumentação , Temperatura , Sequência de Aminoácidos , Desenho de Equipamento , Limite de Detecção , Peptidomiméticos/química , Trastuzumab/análise
2.
PLoS One ; 8(4): e60934, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23585862

RESUMO

Survival of patients with lung cancer could be significantly prolonged should the disease be diagnosed early. Growing evidence indicates that the immune response in the form of autoantibodies to developing cancer is present before clinical presentation. We used a phage-displayed antibody library to select for recombinant scFvs that specifically bind to lung cancer-associated IgM autoantibodies. We selected for scFv recombinant antibodies reactive with circulating IgM autoantibodies found in the serum of patients with early stage lung adenocarcinoma but not matched controls. Discriminatory performance of 6 selected scFvs was validated in an independent set of serum from stage 1 adenocarcinoma and matching control groups using two independent novel methods developed for this application. The panel of 6 selected scFvs predicted cancer based on seroreactivity value with sensitivity of 0.8 and specificity of 0.87. Receiver Operative Characteristic curve (ROC) for combined 6 scFv has an AUC of 0.88 (95%CI, 0.76-1.0) as determined by fluorometric microvolume assay technology (FMAT) The ROC curve generated using a homogeneous bridging Mesa Scale Discovery (MSD) assay had an AUC of 0.72 (95% CI, 0.59-0.85). The panel of all 6 antibodies demonstrated better discriminative power than any single scFv alone. The scFv panel also demonstrated the association between a high score - based on seroreactivity - with poor survival. Selected scFvs were able to recognize lung cancer associated IgM autoantibodies in patient serum as early as 21 months before the clinical presentation of disease. The panel of antibodies discovered represents a potential unique non-invasive molecular tool to detect an immune response specific to lung adenocarcinoma at an early stage of disease.


Assuntos
Adenocarcinoma/diagnóstico , Autoanticorpos/sangue , Biomarcadores Tumorais/sangue , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Imunoglobulina M/sangue , Neoplasias Pulmonares/diagnóstico , Anticorpos de Cadeia Única , Adenocarcinoma/sangue , Adenocarcinoma/imunologia , Adenocarcinoma de Pulmão , Área Sob a Curva , Carcinoma Pulmonar de Células não Pequenas/sangue , Carcinoma Pulmonar de Células não Pequenas/imunologia , Diagnóstico Precoce , Feminino , Humanos , Neoplasias Pulmonares/sangue , Neoplasias Pulmonares/imunologia , Masculino , Biblioteca de Peptídeos , Curva ROC , Anticorpos de Cadeia Única/genética , Anticorpos de Cadeia Única/imunologia
3.
Anal Chem ; 84(19): 8164-70, 2012 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-22934911

RESUMO

Herceptin/Trastuzumab is a humanized IgG1κ light chain antibody used to treat some forms of breast cancer. A phage-displayed recombinant antibody library was used to obtain a single chain fragment variable (scFv, designated 2B4) to a linear synthetic peptide representing Herceptin's heavy chain CDR3. Enzyme linked immunosorbent assays (ELISAs) and piezoimmunosensor/quartz crystal microbalance (QCM) assays were used to characterize 2B4-binding activity to both native and heat denatured Herceptin. The 2B4 scFv specifically bound to heat denatured Herceptin in a concentration dependent manner over a wide (35-220.5 nM) dynamic range. Herceptin denatures and forms significant amounts of aggregates when heated. UV-vis characterization confirms that Herceptin forms aggregates as the temperature used to heat Herceptin increases. QCM affinity assay shows that binding stoichiometry between 2B4 scFv and Herceptin follows a 1:2 relationship proving that 2B4 scFv binds strongly to the dimers of heat denatured Herceptin aggregates and exhibits an affinity constant of 7.17 × 10(13) M(-2). The 2B4-based QCM assay was more sensitive than the corresponding ELISA. Combining QCM with ELISA can be used to more fully characterize nonspecific binding events in assays. The potential theoretical and clinical implications of these results and the advantages of the use of QCM to characterize human therapeutic antibodies in samples are also discussed.


Assuntos
Anticorpos Monoclonais Humanizados/análise , Ensaio de Imunoadsorção Enzimática , Técnicas de Microbalança de Cristal de Quartzo , Anticorpos de Cadeia Única/química , Reações Antígeno-Anticorpo , Biblioteca de Peptídeos , Proteínas Recombinantes/química , Anticorpos de Cadeia Única/isolamento & purificação , Trastuzumab
4.
J Am Soc Mass Spectrom ; 23(10): 1689-96, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22869296

RESUMO

Recombinant scfv antibodies specific for CYP1A1 and CYP1B1 P450 enzymes were combined with targeted imaging mass spectrometry to simultaneously detect the P450 enzymes present in archived, paraffin-embedded, human breast cancer tissue sections. By using CYP1A1 and CYP1B1 specific scfv, each coupled to a unique reporter molecule (i.e., a mass tag) it was possible to simultaneously detect multiple antigens within a single tissue sample with high sensitivity and specificity using mass spectrometry. The capability of imaging multiple antigens at the same time is a significant advance that overcomes technical barriers encountered when using present day approaches to develop assays that can simultaneously detect more than a single antigen in the same tissue sample.


Assuntos
Espectrometria de Massas/métodos , Imagem Molecular/métodos , Anticorpos de Cadeia Única/química , Animais , Anticorpos Monoclonais/química , Anticorpos Monoclonais/imunologia , Hidrocarboneto de Aril Hidroxilases/química , Hidrocarboneto de Aril Hidroxilases/imunologia , Avidina/química , Avidina/imunologia , Biotina/química , Biotina/imunologia , Mama/química , Neoplasias da Mama/química , Citocromo P-450 CYP1A1/química , Citocromo P-450 CYP1A1/imunologia , Citocromo P-450 CYP1B1 , Ensaio de Imunoadsorção Enzimática , Feminino , Histocitoquímica/métodos , Humanos , Camundongos , Ratos , Proteínas Recombinantes/química , Proteínas Recombinantes/metabolismo , Sensibilidade e Especificidade , Anticorpos de Cadeia Única/metabolismo
5.
Anal Chem ; 83(23): 8928-36, 2011 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-21961885

RESUMO

Therapeutic antibodies are antigenically similar to human antibodies and are difficult to detect in assays of human serum samples without the use of the therapeutic antibody's complementary antigen. Herein for the first time, we established a platform to detect Herceptin in solutions by using a small (<2.2 kDa), inexpensive, highly stable human epidermal growth factor receptor (HER2) mimotope-derived synthetic peptide immobilized on the surface of a Au quartz electrode. We used the HER2 mimotope as a substitute for the HER2 receptor protein in piezoimmunosensor or quartz crystal microbalance (QCM) assays to detect Herceptin in human serum. We demonstrated that assay sensitivity was dependent upon the amino acids used to tether and link the peptide to the sensor surface and the buffers used to carry out the assays. The detection limit of the piezoimmunosensor assay was 0.038 nM with a linear operating range of 0.038-0.859 nM. Little nonspecific binding to other therapeutic antibodies (Avastin and Rituxan) was observed. Levels of Herceptin in serum samples obtained from treated patients, as ascertained using the synthetic peptide-based QCM assay, were typical for those treated with Herceptin. The findings of this study are significant in that low-cost synthetic peptides could be used in a QCM assay, in lieu of native or recombinant antigens or capture antibodies, to rapidly detect a therapeutic antibody in human serum. The results suggested that a synthetic peptide bearing a particular functional sequence could be applied for developing a new generation of affinity-based immunosensors to detect a broad range of clinical biomarkers.


Assuntos
Anticorpos Monoclonais Humanizados/sangue , Ouro/química , Peptídeos/química , Técnicas de Microbalança de Cristal de Quartzo , Receptor ErbB-2/química , Eletrodos , Feminino , Humanos , Proteínas Imobilizadas/química , Proteínas Imobilizadas/metabolismo , Imunoensaio , Peptídeos/síntese química , Peptídeos/metabolismo , Ligação Proteica , Receptor ErbB-2/metabolismo , Trastuzumab
6.
Cancer Res ; 70(2): 632-8, 2010 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-20068176

RESUMO

Like many signaling pathways in development, the Notch receptor pathway plays an important role in cancer pathobiology when it is dysregulated. Potential ligand-binding sites within the epidermal growth factor (EGF)-like repeats of Notch1 have been identified, but the ligand-binding domains in Notch3, which is implicated in lung cancer, are not known. In screening a library of 155 peptides representing all 34 EGF-like repeats in Notch3, we discovered two distinct ligand-binding regions involving the 7-10 and 21-22 repeats that are distinct from the putative ligand-binding domain of Notch1. In cell-based assays, peptides from these regions induced apoptosis and reduced expression of the Notch3-dependent gene Hey1. They also bound directly to the Notch ligand Jagged1, suggesting that their mechanism of action involves disrupting interactions between Notch3 and Jagged1. Recombinant Fc fusion peptides engineered for in vivo testing showed that the Notch3 peptides defined could trigger apoptosis and suppress tumor growth in tumor xenograft assays. These findings rationalize a mechanistic approach to lung cancer treatment based on Notch3 receptor-targeted therapeutic development.


Assuntos
Apoptose/efeitos dos fármacos , Neoplasias Pulmonares/tratamento farmacológico , Fragmentos de Peptídeos/farmacologia , Receptores Notch/antagonistas & inibidores , Proteínas Recombinantes de Fusão/farmacologia , Fatores de Transcrição Hélice-Alça-Hélice Básicos/biossíntese , Fatores de Transcrição Hélice-Alça-Hélice Básicos/genética , Sítios de Ligação , Proteínas de Ligação ao Cálcio/metabolismo , Proteínas de Ciclo Celular/biossíntese , Proteínas de Ciclo Celular/genética , Processos de Crescimento Celular/fisiologia , Sistemas de Liberação de Medicamentos , Fator de Crescimento Epidérmico/genética , Fator de Crescimento Epidérmico/metabolismo , Células HeLa , Humanos , Fragmentos Fc das Imunoglobulinas/genética , Fragmentos Fc das Imunoglobulinas/metabolismo , Peptídeos e Proteínas de Sinalização Intercelular/metabolismo , Proteína Jagged-1 , Ligantes , Neoplasias Pulmonares/metabolismo , Neoplasias Pulmonares/patologia , Proteínas de Membrana/metabolismo , Fragmentos de Peptídeos/genética , Fragmentos de Peptídeos/metabolismo , Biblioteca de Peptídeos , Estrutura Terciária de Proteína , Receptor Notch3 , Receptores Notch/metabolismo , Proteínas Recombinantes de Fusão/genética , Proteínas Recombinantes de Fusão/metabolismo , Proteínas Serrate-Jagged
7.
Clin Cancer Res ; 15(24): 7479-7491, 2009 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-20008848

RESUMO

HER2 is a transmembrane oncoprotein encoded by the HER2/neu gene and is overexpressed in approximately 20 to 25% of invasive breast cancers. It can be therapeutically targeted by trastuzumab, a humanized IgG1 kappa light chain monoclonal antibody. Although trastuzumab is currently considered one of the most effective treatments in oncology, a significant number of patients with HER2-overexpressing breast cancer do not benefit from it. Understanding the mechanisms of action and resistance to trastuzumab is therefore crucial for the development of new therapeutic strategies. This review discusses proposed trastuzumab mode of action as well as proposed mechanisms for resistance. Mechanisms for resistance are grouped into four main categories: (1) obstacles preventing trastuzumab binding to HER2; (2) upregulation of HER2 downstream signaling pathways; (3) signaling through alternate pathways; and (4) failure to trigger an immune-mediated mechanism to destroy tumor cells. These potential mechanisms through which trastuzumab resistance may arise have been used as a guide to develop drugs, presently in clinical trials, to overcome resistance. The mechanisms conferring trastuzumab resistance, when completely understood, will provide insight on how best to treat HER2-overexpressing breast cancer. The understanding of each mechanism of resistance is therefore critical for the educated development of strategies to overcome it, as well as for the development of tools that would allow definitive and efficient patient selection for each therapy. (Clin Cancer Res 2009;15(24):7479-91).

9.
J Mol Histol ; 39(4): 351-8, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18438736

RESUMO

To gain insight into the mechanism by which angiotensin II type 2 receptor (AT(2)) regulates carcinogen-induced lung tumorigenesis, we have newly developed anti-AT(2) single chain variable fragment (ScFv) antibodies using a rodent phage-displayed recombinant antibody library with various peptide fragments of the receptor protein, and investigated the expression of the AT(2) receptor protein. The specificity of the antibodies was verified using AT(2) over-expressing COS-7 cells and AT(2) naturally expressing PC12W cells. In control wild type mouse lung, a stronger immunoreactivity was observed in bronchial epithelial cells. A moderate immunoreactivity was detected in pulmonary vascular walls and vascular endothelial cells. In the lungs possessing tobacco-specific nitrosamine (NNK)-induced tumors, significantly increased AT(2) and AT(1 )immunostaining was observed in adenomatous lesions. These data suggest that the increase in both receptors' expression in the alveolar epithelial cells may be accompanied with the onset of NNK-induced tumorigenesis and hence play important roles in lung tumorigenesis.


Assuntos
Anticorpos/imunologia , Especificidade de Anticorpos/imunologia , Neoplasias Pulmonares/metabolismo , Pulmão/metabolismo , Receptor Tipo 2 de Angiotensina/imunologia , Receptor Tipo 2 de Angiotensina/metabolismo , Animais , Linhagem Celular , Chlorocebus aethiops , Imuno-Histoquímica , Pulmão/imunologia , Neoplasias Pulmonares/induzido quimicamente , Neoplasias Pulmonares/imunologia , Neoplasias Pulmonares/patologia , Masculino , Camundongos , Camundongos Knockout , Nitrosaminas/farmacologia , Ratos , Receptor Tipo 2 de Angiotensina/deficiência , Receptor Tipo 2 de Angiotensina/genética
10.
Carcinogenesis ; 28(10): 2184-92, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17468514

RESUMO

Little is known about early carcinogen-induced protein alterations in mammary epithelium. Detection of early alterations would enhance our understanding of early-stage carcinogenesis. Here, normal human mammary epithelial cells (HMECs) were exposed to dietary and environmental carcinogens [2-amino-1-methyl-6-phenylimidazo[4,5b]pyridine (PhIP), 4-aminobiphenyl (ABP), benzo[a]pyrene, 2,3,7,8-tetrachlorodibenzo-p-dioxin] individually or in combination. A phage display library of single-chain variable fragment antibodies was used to screen protein targets altered by the treatment. In combination with matrix-assisted laser desorption time of flight, we identified histone H3 as a target antigen. Although histone H3 total protein remained unchanged in control and treated HMEC, the methylation of lysine 4 was altered. A reduction in mono-methyl histone H3 (Lys 4) was observed in treated HMEC compared with control HMEC. This alteration was shown to be dependent on carcinogen concentration and specific for PhIP and ABP. To characterize potential histone demethylation mechanisms, localization and protein expression patterns of lysine-specific demethylase 1 (LSD1) were analyzed. In control HMEC, LSD1 was present at the nuclear periphery. However, following 72 h carcinogen treatment, LSD1 localized within the nucleus. Within 48 h after treatment, mono-methyl histone H3 (Lys 4) was restored and LSD1 localization was reversed. Protein expression levels of LSD1 were also increased in treated HMEC compared with control HMEC. Our data suggest that the induction of a single enzyme, LSD1, represents an early response to carcinogen exposure, which leads to the demethylation of histone H3 (Lys 4), which, in turn, may influence the expression of multiple genes critical in early-stage mammary carcinogenesis.


Assuntos
Mama/citologia , Mama/fisiologia , Carcinógenos/toxicidade , Células Epiteliais/fisiologia , Histonas/metabolismo , Compostos de Aminobifenil/toxicidade , Benzo(a)pireno/toxicidade , Biotinilação , Células Cultivadas , Células Epiteliais/citologia , Células Epiteliais/efeitos dos fármacos , Feminino , Histonas/efeitos dos fármacos , Histonas/isolamento & purificação , Humanos , Imidazóis/toxicidade , Região Variável de Imunoglobulina/imunologia , Biblioteca de Peptídeos , Dibenzodioxinas Policloradas/toxicidade , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
11.
Biotechnol Bioeng ; 91(6): 699-706, 2005 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-15895380

RESUMO

Two attractive features of ELISA are the specificity of antibody-antigen recognition and the sensitivity achieved by enzymatic amplification. This report describes the development of a non-enzymatic molecular recognition platform adaptable to point-of-care clinical settings and field detection of biohazardous materials. This filament-antibody recognition assay (FARA) is based on circumferential bands of antibody probes coupled to a 120 microm diameter polyester filament. One advantage of this design is that automated processing is achieved by sequential positioning of filament-coupled probes through a series of 25-60 microL liquid filled microcapillary chambers. This approach was evaluated by testing for the presence of M13KO7 bacterial virus using anti-M13KO7 IgG(1) monoclonal antibody coupled to a filament. Filament motion first positioned the antibodies within a microcapillary tube containing a solution of M13KO7 virus before moving the probes through subsequent chambers, where the filament-coupled probes were washed, exposed to a fluorescently labeled anti-M13K07 antibody, and washed again. Filament fluorescence was then measured using a flatbed microarray scanner. The presence of virus in solution produced a characteristic increase in filament fluorescence only in regions containing coupled antibody probes. Even without the enzymatic amplification of a typical ELISA, the presence of 8.3 x 10(8) virus particles produced a 30-fold increase in fluorescence over an immobilized negative control antibody. In an ELISA comparison study, the filament-based approach had a similar lower limit of sensitivity of approximately 1.7 x 10(7) virus particles. This platform may prove attractive for point-of-care settings, the detection of biohazardous materials, or other applications where sensitive, rapid, and automated molecular recognition is desired.


Assuntos
Anticorpos Monoclonais/química , Técnicas Imunoenzimáticas/métodos , Vírus/isolamento & purificação , Especificidade de Anticorpos , Automação , Bacteriófagos/imunologia , Bacteriófagos/isolamento & purificação , Ensaio de Imunoadsorção Enzimática , Fluorescência , Técnicas Imunoenzimáticas/instrumentação , Sensibilidade e Especificidade , Virologia/métodos
12.
Anal Chem ; 77(3): 797-805, 2005 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-15679346

RESUMO

In this paper, we describe a novel nonlabeled biosensor with high diagnostic potential for rapid and sensitive detection of antigens in complex biological samples. The biosensor comprises a piezoimmunosensor (PZ) displaying a specially constructed recombinant antibody on its surface. The recombinant single-chain fragment variable (scFv) antibody contained a cysteine within the linker amino acid sequence used to join the scFv variable heavy and light chains. The presence of cysteine induced the scFv construct to self-assemble as a densely packed rigid monolayer on the gold surface of a quartz crystal microbalance. scFv molecules in this self-assembled monolayer (SAM) exhibited a defined orientation and high areal densities, with scFv-modified microbalance surfaces displaying 35 times as many variable antigen-binding sites per square centimeter as surfaces modified with whole antibody. Experimental data show that the scFv SAM PZ is superior to Fab fragment, Fab fragment containing a free sulfhydryl group (i.e., Fab-SH), and whole antibody PZs regarding sensitivity and specificity. Because of their small uniform size (MW approximately 27000) and the ease with which they can be modified using genetic engineering, scFv's have significant advantages over whole antibodies in microbalance biosensor systems. We demonstrate here that the use of scFv containing a cysteine within the scFv linker sequence (i.e., scFv-cys) for preparation of biosensor surfaces markedly increases the density of available antigen-binding sites, yielding a system that is highly selective, rapid, and capable of detecting low concentrations of antigens in complex samples.


Assuntos
Anticorpos Monoclonais/análise , Técnicas Biossensoriais/métodos , Imunoensaio/métodos , Fragmentos de Imunoglobulinas/análise , Sequência de Aminoácidos , Anticorpos Monoclonais/química , Complexo Antígeno-Anticorpo , Técnicas Biossensoriais/instrumentação , Cisteína/química , Imunoensaio/instrumentação , Fragmentos de Imunoglobulinas/química , Fragmentos de Imunoglobulinas/imunologia , Dados de Sequência Molecular , Quartzo , Proteínas Recombinantes/química , Sensibilidade e Especificidade , Fatores de Tempo
13.
Infect Immun ; 72(6): 3429-35, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15155649

RESUMO

The BabA adhesin of Helicobacter pylori is an outer membrane protein that binds to the fucosylated Lewis b histo-blood group antigen on the surface of gastric epithelial cells. We screened a phage-displayed ScFv (single-chain fragment variable) recombinant antibody library for antibodies reactive with a recombinant BabA fragment and identified two such antibodies. Each antibody recognized an approximately 75-kDa protein present in wild-type H. pylori strain J99 but absent from an isogenic babA mutant strain. An immunoreactive BabA protein was detected by at least one of the antibodies in 18 (46%) of 39 different wild-type H. pylori strains and was detected more commonly in cagA-positive strains than in cagA-negative strains. Numerous amino acid polymorphisms were detected among BabA proteins expressed by different strains, with the greatest diversity occurring in the middle region of the proteins. Among the 18 strains that expressed a detectable BabA protein, there was considerable variation in the level of binding to Lewis b in vitro. Heterogeneity among H. pylori strains in expression of the BabA protein may be a factor that contributes to differing clinical outcomes among H. pylori-infected humans.


Assuntos
Adesinas Bacterianas/metabolismo , Proteínas de Transporte/metabolismo , Variação Genética , Infecções por Helicobacter/microbiologia , Helicobacter pylori/genética , Adesinas Bacterianas/genética , Sequência de Aminoácidos , Proteínas de Transporte/genética , Helicobacter pylori/classificação , Helicobacter pylori/metabolismo , Helicobacter pylori/patogenicidade , Humanos , Immunoblotting , Região Variável de Imunoglobulina/imunologia , Antígenos do Grupo Sanguíneo de Lewis/metabolismo , Dados de Sequência Molecular , Biblioteca de Peptídeos , Alinhamento de Sequência , Análise de Sequência de DNA
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA