Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
Radiol Med ; 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38700556

RESUMO

PURPOSE: High PSMA expression might be correlated with structural characteristics such as growth patterns on histopathology, not recognized by the human eye on MRI images. Deep structural image analysis might be able to detect such differences and therefore predict if a lesion would be PSMA positive. Therefore, we aimed to train a neural network based on PSMA PET/MRI scans to predict increased prostatic PSMA uptake based on the axial T2-weighted sequence alone. MATERIAL AND METHODS: All patients undergoing simultaneous PSMA PET/MRI for PCa staging or biopsy guidance between April 2016 and December 2020 at our institution were selected. To increase the specificity of our model, the prostatic beds on PSMA PET scans were dichotomized in positive and negative regions using an SUV threshold greater than 4 to generate a PSMA PET map. Then, a C-ENet was trained on the T2 images of the training cohort to generate a predictive prostatic PSMA PET map. RESULTS: One hundred and fifty-four PSMA PET/MRI scans were available (133 [68Ga]Ga-PSMA-11 and 21 [18F]PSMA-1007). Significant cancer was present in 127 of them. The whole dataset was divided into a training cohort (n = 124) and a test cohort (n = 30). The C-ENet was able to predict the PSMA PET map with a dice similarity coefficient of 69.5 ± 15.6%. CONCLUSION: Increased prostatic PSMA uptake on PET might be estimated based on T2 MRI alone. Further investigation with larger cohorts and external validation is needed to assess whether PSMA uptake can be predicted accurately enough to help in the interpretation of mpMRI.

2.
EJNMMI Res ; 14(1): 36, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38578516

RESUMO

BACKGROUND: Liver uptake in [68Ga]Ga-PSMA-11 PET is used as an internal reference in addition to clinical parameters to select patients for [177Lu]Lu-PSMA-617 radioligand therapy (RLT). Due to increased demand, [68Ga]Ga-PSMA-11 was replaced by [18F]F-PSMA-1007, a more lipophilic tracer with different biodistribution and splenic uptake was suggested as a new internal reference. We compared the intra-patient tracer distribution between [68Ga]Ga-PSMA-11 and [18F]F-PSMA-1007. METHODS: Fifty patients who underwent PET examinations in two centers with both [18F]F-PSMA-1007 and [68Ga]Ga-PSMA-11 within one year were included. Mean standardized uptake values (SUVmean) were obtained for liver, spleen, salivary glands, blood pool, and bone. Primary tumor, local recurrence, lymph node, bone or visceral metastasis were also assessed for intra- and inter-individual comparison. RESULTS: Liver SUVmean was significantly higher with [18F]F-PSMA-1007 (11.7 ± 3.9) compared to [68Ga]Ga-PSMA-11 (5.4 ± 1.7, p < .05) as well as splenic SUVmean (11.2 ± 3.5 vs.8.1 ± 3.5, p < .05). The blood pool was comparable between the two scans. Malignant lesions did not show higher SUVmean on [18F]F-PSMA-1007. Intra-individual comparison of liver uptake between the two scans showed a linear association for liver uptake with SUVmean [68Ga]Ga-PSMA-11 = 0.33 x SUVmean [18F]F-PSMA-1007 + 1.52 (r = .78, p < .001). CONCLUSION: Comparing biodistribution of [68Ga]Ga and [18F]F tracers, liver uptake on [68Ga]Ga-PSMA-11 PET is the most robust internal reference value. Liver uptake of [18F]F-PSMA-1007 was significantly higher, but so was the splenic uptake. The strong intra-individual association of hepatic accumulation between the two scans may allow using of a conversion factor for [18F]F-PSMA-1007 as a basis for RLT selection.

3.
Sci Rep ; 13(1): 18847, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37914764

RESUMO

The purpose of this retrospective study was to investigate response of sinonasal mucosal melanoma (SMM) patients to treatment with immune checkpoint inhibitors (ICI), using hybrid PET imaging. Fifteen SMM patients underwent hybrid PET imaging before and three months after initiation of ICI. The disease-specific survival (DSS) was calculated. Quantitative PET parameters of the primary tumor and their association with DSS and therapy response were investigated. Nine of the fifteen (60%) patients responded to ICI therapy. Patients with therapy response depicted on hybrid PET imaging had better DSS than those without (p = 0.0058). Quantitative PET parameters of the initial PET harbored no association with DSS or therapy response. However, these findings lack of sufficient statistical power and must be interpreted with caution. The first restaging PET-imaging after ICI initiation can help stratify patients with regard to DSS.


Assuntos
Melanoma , Neoplasias dos Seios Paranasais , Humanos , Inibidores de Checkpoint Imunológico/farmacologia , Inibidores de Checkpoint Imunológico/uso terapêutico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Retrospectivos , Melanoma/diagnóstico por imagem , Melanoma/tratamento farmacológico , Melanoma/patologia , Tomografia por Emissão de Pósitrons , Neoplasias dos Seios Paranasais/patologia , Fluordesoxiglucose F18
4.
Cancers (Basel) ; 15(22)2023 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-38001731

RESUMO

OBJECTIVE: The increasing use of PSMA-PET/CT for restaging prostate cancer (PCa) leads to a patient shift from a non-metastatic situation based on conventional imaging (CI) to a metastatic situation. Since established therapeutic pathways have been designed according to CI, it is unclear how this should be translated to the PSMA-PET/CT results. This study aimed to investigate whether PSMA-PET/CT and clinical parameters could predict the visibility of PSMA-positive lesions on a bone scan (BS). METHODS: In four different centers, all PCa patients with BS and PSMA-PET/CT within 6 months without any change in therapy or significant disease progression were retrospectively selected. Up to 10 non-confluent clear bone metastases were selected per PSMA-PET/CT and SUVmax, SUVmean, PSMAtot, PSMAvol, density, diameter on CT, and presence of cortical erosion were collected. Clinical variables (age, PSA, Gleason Score) were also considered. Two experienced double-board physicians decided whether a bone metastasis was visible on the BS, with a consensus readout for discordant findings. For predictive performance, a random forest was fit on all available predictors, and its accuracy was assessed using 10-fold cross-validation performed 10 times. RESULTS: A total of 43 patients were identified with 222 bone lesions on PSMA-PET/CT. A total of 129 (58.1%) lesions were visible on the BS. In the univariate analysis, all PSMA-PET/CT parameters were significantly associated with the visibility on the BS (p < 0.001). The random forest reached a mean accuracy of 77.6% in a 10-fold cross-validation. CONCLUSIONS: These preliminary results indicate that there might be a way to predict the BS results based on PSMA-PET/CT, potentially improving the comparability between both examinations and supporting decisions for therapy selection.

5.
Sci Rep ; 13(1): 18357, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37884535

RESUMO

This study aimed to evaluate the diagnostic accuracy of Node Reporting and Data System (Node-RADS) in discriminating between normal, reactive, and metastatic axillary LNs in patients with melanoma who underwent SARS-CoV-2 vaccination. Patients with proven melanoma who underwent a 2-[18F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (2-[18F]-FDG PET/CT) between February and April 2021 were included in this retrospective study. Primary melanoma site, vaccination status, injection site, and 2-[18F]-FDG PET/CT were used to classify axillary LNs into normal, inflammatory, and metastatic (combined classification). An adapted Node-RADS classification (A-Node-RADS) was generated based on LN anatomical characteristics on low-dose CT images and compared to the combined classification. 108 patients were included in the study (54 vaccinated). HALNs were detected in 42 patients (32.8%), of whom 97.6% were vaccinated. 172 LNs were classified as normal, 30 as inflammatory, and 14 as metastatic using the combined classification. 152, 22, 29, 12, and 1 LNs were classified A-Node-RADS 1, 2, 3, 4, and 5, respectively. Hence, 174, 29, and 13 LNs were deemed benign, equivocal, and metastatic. The concordance between the classifications was very good (Cohen's k: 0.91, CI 0.86-0.95; p-value < 0.0001). A-Node-RADS can assist the classification of axillary LNs in melanoma patients who underwent 2-[18F]-FDG PET/CT and SARS-CoV-2 vaccination.


Assuntos
COVID-19 , Melanoma , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Vacinas contra COVID-19 , SARS-CoV-2 , Fluordesoxiglucose F18 , Estudos Retrospectivos , Estadiamento de Neoplasias , Metástase Linfática/patologia , COVID-19/diagnóstico por imagem , COVID-19/patologia , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Melanoma/diagnóstico por imagem , Melanoma/patologia , Vacinação , Compostos Radiofarmacêuticos
6.
Br J Radiol ; 96(1152): 20220482, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37751216

RESUMO

OBJECTIVES: To evaluate the evolution of CT radiation dose in pediatric patients undergoing hybrid 2-[18F]fluoro-2-deoxy-D-glucose (2-[18F]FDG) PET/CT between 2007 and 2021. METHODS AND MATERIALS: Data from all pediatric patients aged 0-18 years who underwent hybrid 2-[18F]FDG PET/CT of the body between January 2007 and May 2021 were reviewed. Demographic and imaging parameters were collected. A board-certified radiologist reviewed all CT scans and measured image noise in the brain, liver, and adductor muscles. RESULTS: 294 scans from 167 children (72 females (43%); median age: 14 (IQR 10-15) years; BMI: median 17.5 (IQR 15-20.4) kg/m2) were included. CT dose index-volume (CTDIvol) and dose length product (DLP) both decreased significantly from 2007 to 2021 (both p < 0.001, Spearman's rho coefficients -0.46 and -0.35, respectively). Specifically, from 2007 to 2009 to 2019-2021 CTDIvol and DLP decreased from 2.94 (2.14-2.99) mGy and 309 (230-371) mGy*cm, respectively, to 0.855 (0.568-1.11) mGy and 108 (65.6-207) mGy*cm, respectively. From 2007 to 2021, image noise in the brain and liver remained constant (p = 0.26 and p = 0.06), while it decreased in the adductor muscles (p = 0.007). Peak tube voltage selection (in kilovolt, kV) of CT scans shifted from high kV imaging (140 or 120kVp) to low kV imaging (100 or 80kVp) (p < 0.001) from 2007 to 2021. CONCLUSION: CT radiation dose in pediatric patients undergoing hybrid 2-[18F]FDG PET/CT has decreased in recent years equaling approximately one-third of the initial amount. ADVANCES IN KNOWLEDGE: Over the past 15 years, CT radiation dose decreased considerably in pediatric patients undergoing hybrid imaging, while objective image quality may not have been compromised.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Feminino , Humanos , Criança , Adolescente , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Encéfalo
7.
Nat Commun ; 14(1): 5154, 2023 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-37620318

RESUMO

Immune checkpoint inhibitor treatment has the potential to prolong survival in non-small cell lung cancer (NSCLC), however, some of the patients develop resistance following initial response. Here, we analyze the immune phenotype of matching tumor samples from a cohort of NSCLC patients showing good initial response to immune checkpoint inhibitors, followed by acquired resistance at later time points. By using imaging mass cytometry and whole exome and RNA sequencing, we detect two patterns of resistance¨: One group of patients is characterized by reduced numbers of tumor-infiltrating CD8+ T cells and reduced expression of PD-L1 after development of resistance, whereas the other group shows high CD8+ T cell infiltration and high expression of PD-L1 in addition to markedly elevated expression of other immune-inhibitory molecules. In two cases, we detect downregulation of type I and II IFN pathways following progression to resistance, which could lead to an impaired anti-tumor immune response. This study thus captures the development of immune checkpoint inhibitor resistance as it progresses and deepens our mechanistic understanding of immunotherapy response in NSCLC.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Carcinoma Pulmonar de Células não Pequenas/genética , Linfócitos T CD8-Positivos , Antígeno B7-H1/genética , Inibidores de Checkpoint Imunológico , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/genética , Imunossupressores , Fenótipo
8.
Diagnostics (Basel) ; 13(4)2023 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-36832118

RESUMO

BACKGROUND: To assess the impact of the lung cancer screening protocol recommended by the European Society of Thoracic Imaging (ESTI) on nodule diameter, volume, and density throughout different computed tomography (CT) scanners. METHODS: An anthropomorphic chest phantom containing fourteen different-sized (range 3-12 mm) and CT-attenuated (100 HU, -630 HU and -800 HU, termed as solid, GG1 and GG2) pulmonary nodules was imaged on five CT scanners with institute-specific standard protocols (PS) and the lung cancer screening protocol recommended by ESTI (ESTI protocol, PE). Images were reconstructed with filtered back projection (FBP) and iterative reconstruction (REC). Image noise, nodule density and size (diameter/volume) were measured. Absolute percentage errors (APEs) of measurements were calculated. RESULTS: Using PE, dosage variance between different scanners tended to decrease compared to PS, and the mean differences were statistically insignificant (p = 0.48). PS and PE(REC) showed significantly less image noise than PE(FBP) (p < 0.001). The smallest size measurement errors were noted with volumetric measurements in PE(REC) and highest with diametric measurements in PE(FBP). Volume performed better than diameter measurements in solid and GG1 nodules (p < 0.001). However, in GG2 nodules, this could not be observed (p = 0.20). Regarding nodule density, REC values were more consistent throughout different scanners and protocols. CONCLUSION: Considering radiation dose, image noise, nodule size, and density measurements, we fully endorse the ESTI screening protocol including the use of REC. For size measurements, volume should be preferred over diameter.

9.
Vaccine ; 40(52): 7640-7645, 2022 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-36372666

RESUMO

PURPOSE: To evaluate the temporal evolution of vaccination against COVID-19 in a Swiss oncological cohort. METHODS: History of complete vaccination (i.e. at least two vaccine doses) against COVID-19 of patients undergoing oncological 18F-FDG PET/CT between February and September 2021 (n = 2613) was taken. Vaccination rate was compared with age-matched national data from the Swiss Federal Office of Public Health. Subgroup differences in temporal evolution of vaccination rate were analyzed by fitting a generalized linear model and determined by significant interaction between, sex, oncological diagnosis, and month of examination. RESULTS: Rate of complete vaccination against COVID-19 steadily increased and reached 81 % in September 2021. The fraction of vaccinated patients in the oncological cohort was higher in the beginning and approached the fraction in the age-matched general Swiss population at the end of the study period. Month of exam (p < 0.001) was the only significant predictor of the vaccination rate. CONCLUSION: Vaccination rate against COVID-19 in a Swiss oncological cohort increased steadily from February to September 2021. Compared to the age-matched general population it was higher in the beginning and similar by the end of the study period. Ethics approval: Trial registration: BASEC 2021-00444, Ethikkommission Zürich (Cantonal Ethics Committee Zurich), Switzerland, registered February 24th 2021.


Assuntos
COVID-19 , Fluordesoxiglucose F18 , Humanos , Vacinas contra COVID-19 , COVID-19/prevenção & controle , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Vacinação
10.
Sci Rep ; 12(1): 19191, 2022 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-36357446

RESUMO

Our aim was to identify and quantify high coronary artery calcium (CAC) with deep learning (DL)-powered CAC scoring (CACS) in oncological patients with known very high CAC (≥ 1000) undergoing 18F-FDG-PET/CT for re-/staging. 100 patients were enrolled: 50 patients with Agatston scores ≥ 1000 (high CACS group), 50 patients with Agatston scores < 1000 (negative control group). All patients underwent oncological 18F-FDG-PET/CT and cardiac SPECT myocardial perfusion imaging (MPI) by 99mTc-tetrofosmin within 6 months. CACS was manually performed on dedicated non-contrast ECG-gated CT scans obtained from SPECT-MPI (reference standard). Additionally, CACS was performed fully automatically with a user-independent DL-CACS tool on non-contrast, free-breathing, non-gated CT scans from 18F-FDG-PET/CT examinations. Image quality and noise of CT scans was assessed. Agatston scores obtained by manual CACS and DL tool were compared. The high CACS group had Agatston scores of 2200 ± 1620 (reference standard) and 1300 ± 1011 (DL tool, average underestimation of 38.6 ± 26%) with an intraclass correlation of 0.714 (95% CI 0.546, 0.827). Sufficient image quality significantly improved the DL tool's capability of correctly assigning Agatston scores ≥ 1000 (p = 0.01). In the control group, the DL tool correctly assigned Agatston scores < 1000 in all cases. In conclusion, DL-based CACS performed on non-contrast free-breathing, non-gated CT scans from 18F-FDG-PET/CT examinations of patients with known very high (≥ 1000) CAC underestimates CAC load, but correctly assigns an Agatston scores ≥ 1000 in over 70% of cases, provided sufficient CT image quality. Subgroup analyses of the control group showed that the DL tool does not generate false-positives.


Assuntos
Doença da Artéria Coronariana , Aprendizado Profundo , Hipercalcemia , Humanos , Vasos Coronários/diagnóstico por imagem , Cálcio , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Doença da Artéria Coronariana/diagnóstico por imagem , Cálcio da Dieta
11.
Life (Basel) ; 12(9)2022 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-36143386

RESUMO

Background: Investigation of the clinical feasibility of dynamic whole-body (WB) [18F]FDG PET, including standardized uptake value (SUV), rate of irreversible uptake (Ki), and apparent distribution volume (Vd) in physiologic tissues, and comparison between inflammatory/infectious and cancer lesions. Methods: Twenty-four patients were prospectively included to undergo dynamic WB [18F]FDG PET/CT for clinically indicated re-/staging of oncological diseases. Parametric maps of Ki and Vd were generated using Patlak analysis alongside SUV images. Maximum parameter values (SUVmax, Kimax, and Vdmax) were measured in liver parenchyma and in malignant or inflammatory/infectious lesions. Lesion-to-background ratios (LBRs) were calculated by dividing the measurements by their respective mean in the liver tissue. Results: Seventy-seven clinical target lesions were identified, 60 malignant and 17 inflammatory/infectious. Kimax was significantly higher in cancer than in inflammatory/infections lesions (3.0 vs. 2.0, p = 0.002) while LBRs of SUVmax, Kimax, and Vdmax did not differ significantly between the etiologies: LBR (SUVmax) 3.3 vs. 2.9, p = 0.06; LBR (Kimax) 5.0 vs. 4.4, p = 0.05, LBR (Vdmax) 1.1 vs. 1.0, p = 0.18). LBR of inflammatory/infectious and cancer lesions was higher in Kimax than in SUVmax (4.5 vs. 3.2, p < 0.001). LBRs of Kimax and SUVmax showed a strong correlation (Spearman's rho = 0.83, p < 0.001). Conclusions: Dynamic WB [18F]FDG PET/CT is feasible in a clinical setting. LBRs of Kimax were higher than SUVmax. Kimax was higher in malignant than in inflammatory/infectious lesions but demonstrated a large overlap between the etiologies.

12.
Diagnostics (Basel) ; 12(8)2022 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-36010226

RESUMO

OBJECTIVES: The objective of this study was to assess the feasibility and accuracy of a fully automated artificial intelligence (AI) powered coronary artery calcium scoring (CACS) method on ungated CT in oncologic patients undergoing 18F-FDG PET/CT. METHODS: A total of 100 oncologic patients examined between 2007 and 2015 were retrospectively included. All patients underwent 18F-FDG PET/CT and cardiac SPECT myocardial perfusion imaging (MPI) by 99mTc-tetrofosmin within 6 months. CACS was manually performed on non-contrast ECG-gated CT scans obtained from SPECT-MPI (i.e., reference standard). Additionally, CACS was performed using a cloud-based, user-independent tool (AI-CACS) on ungated CT scans from 18F-FDG-PET/CT examinations. Agatston scores from the manual CACS and AI-CACS were compared. RESULTS: On a per-patient basis, the AI-CACS tool achieved a sensitivity and specificity of 85% and 90% for the detection of CAC. Interscore agreement of CACS between manual CACS and AI-CACS was 0.88 (95% CI: 0.827, 0.918). Interclass agreement of risk categories was 0.8 in weighted Kappa analysis, with a reclassification rate of 44% and an underestimation of one risk category by AI-CACS in 39% of cases. On a per-vessel basis, interscore agreement of CAC scores ranged from 0.716 for the circumflex artery to 0.863 for the left anterior descending artery. CONCLUSIONS: Fully automated AI-CACS as performed on non-contrast free-breathing, ungated CT scans from 18F-FDG-PET/CT examinations is feasible and provides an acceptable to good estimation of CAC burden. CAC load on ungated CT is, however, generally underestimated by AI-CACS, which should be taken into account when interpreting imaging findings.

13.
BJR Open ; 4(1): 20210084, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36017171

RESUMO

Objectives: To assess the frequency and intensity of [18F]-prostate-specific membrane antigen (PSMA)-1007 axillary uptake in lymph nodes ipsilateral to COVID-19 vaccination with BNT162b2 (Pfizer-BioNTech) or mRNA-1273 (Moderna) in patients with prostate cancer referred for oncological [18F]-PSMA positron emission tomography (PET)/CT or PET/MR imaging. Methods: 126 patients undergoing [18F]-PSMA PET/CT or PET/MR imaging were retrospectively included. [18F]-PSMA activity (maximum standardized uptake value) of ipsilateral axillary lymph nodes was measured and compared with the non-vaccinated contralateral side and with a non-vaccinated negative control group. [18F]-PSMA active lymph node metastases were measured to serve as quantitative reference. Results: There was a significant difference in maximum standardized uptake value in ipsilateral and compared to contralateral axillary lymph nodes in the vaccination group (n = 63, p < 0.001) and no such difference in the non-vaccinated control group (n = 63, p = 0.379). Vaccinated patients showed mildly increased axillary lymph node [18F]-PSMA uptake as compared to non-vaccinated patients (p = 0.03). [18F]-PSMA activity of of lymph node metastases was significantly higher (p < 0.001) compared to axillary lymph nodes of vaccinated patients. Conclusion: Our data suggest mildly increased [18F]-PSMA uptake after COVID-19 vaccination in ipsilateral axillary lymph nodes. However, given the significantly higher [18F]-PSMA uptake of prostatic lymph node metastases compared to "reactive" nodes after COVID-19 vaccination, no therapeutic and diagnostic dilemma is to be expected. Advances in knowledge: No specific preparations or precautions (e.g. adaption of vaccination scheduling) need to be undertaken in patients undergoing [18F]-PSMA PET imaging after COVID-19 vaccination.

14.
Eur J Nucl Med Mol Imaging ; 50(1): 130-159, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35974185

RESUMO

Cardiovascular diseases (CVD) remain the leading cause of mortality worldwide. Although major diagnostic and therapeutic advances have significantly improved the prognosis of patients with CVD in the past decades, these advances have less benefited women than age-matched men. Noninvasive cardiac imaging plays a key role in the diagnosis of CVD. Despite shared imaging features and strategies between both sexes, there are critical sex disparities that warrant careful consideration, related to the selection of the most suited imaging techniques, to technical limitations, and to specific diseases that are overrepresented in the female population. Taking these sex disparities into consideration holds promise to improve management and alleviate the burden of CVD in women. In this review, we summarize the specific features of cardiac imaging in four of the most common presentations of CVD in the female population including coronary artery disease, heart failure, pregnancy complications, and heart disease in oncology, thereby highlighting contemporary strengths and limitations. We further propose diagnostic algorithms tailored to women that might help in selecting the most appropriate imaging modality.


Assuntos
Doenças Cardiovasculares , Doença da Artéria Coronariana , Insuficiência Cardíaca , Masculino , Gravidez , Humanos , Feminino , Doença da Artéria Coronariana/diagnóstico por imagem , Doenças Cardiovasculares/diagnóstico por imagem , Técnicas de Imagem Cardíaca , Prognóstico , Fatores de Risco , Fatores Sexuais
15.
Insights Imaging ; 13(1): 118, 2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35838922

RESUMO

BACKGROUND: Quantifying femoral and tibial torsion is crucial in the preoperative planning for derotation surgery in children and adolescents. The use of an ultra-low-dose computed tomography (CT) protocol might be possible for modern CT scanners and suitable for reliable torsion measurements even though the bones are not completely ossified. METHODS: This is a retrospective review of 77 children/adolescents (mean age 12.7 years) who underwent a lower extremity CT for torsion measurements on a 64-slice scanner. A stepwise dose reduction (70%, 50%, 30% of the original dose) was simulated. Torsion measurements were performed on all image datasets, and image noise, interrater agreement and subjective image quality were evaluated. Effective radiation dose of each original scan was estimated. As proof of concept, 24 children were scanned with an ultra-low-dose protocol, adapted from the 30% dose simulation, and the intra-class correlation coefficient (ICC) was determined. Ethics approval and informed consent were given. RESULTS: Torsion measurements at the simulated 30% dose level had equivalent interrater agreement compared to the 100% dose level (ICC ≥ 0.99 for all locations and dose levels). Image quality of almost all datasets was rated excellent, regardless of dose. The mean sum of the effective dose of the total torsion measurement was reduced by simulation from 0.460/0.490 mSv (boys/girls) at 100% dose to 0.138/0.147 mSv at 30%. The ICC of the proof-of-concept group was as good as that of the simulated 30% dose level. CONCLUSION: Pediatric torsion measurements of the lower extremities can be performed using an ultra-low-dose protocol without compromising diagnostic confidence.

16.
Sci Rep ; 12(1): 11392, 2022 07 06.
Artigo em Inglês | MEDLINE | ID: mdl-35794149

RESUMO

Alveolar echinococcosis is a rare parasitic disease, most frequently affecting the liver, as a slow-growing tumor-like lesion. If inoperable, long-term benzimidazole therapy is required, which is associated with high healthcare costs and occasionally with increased morbidity. The aim of our study was to determine the role 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in staging of patients with alveolar echinococcosis and to identify quantitative imaging parameters related to patient outcome and/or duration of benzimidazole therapy. In this single-center retrospective cohort study, 47 PET/CT performed for staging in patients with confirmed alveolar echinococcosis were analysed. In 43 patients (91%) benzimidazole therapy was initiated and was successfully stopped after a median of 870 days (766-2517) in 14/43 patients (33%). In inoperable patients, tests for trend of survivor functions displayed clear trends for longer benzimidazole therapy duration (p = 0.05; n = 25), and for longer time intervals to reach non-detectable serum concentration of Em-18 antibodies (p = 0.01, n = 15) across tertiles of SUVratio (maximum standardized uptake value in the echinococcus manifestation compared to normal liver tissue). Hence, in inoperable patients with alveolar echinococcosis, PET/CT performed for staging may predict the duration of benzimidazole therapy.


Assuntos
Duração da Terapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Benzimidazóis/uso terapêutico , Equinococose , Humanos , Estudos Retrospectivos
17.
Sci Rep ; 12(1): 8308, 2022 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-35585129

RESUMO

To evaluate the impact of block sequential regularized expectation maximization (BSREM) reconstruction on quantitative and qualitative aspects of 2-[18F]FDG-avid pulmonary nodules compared to conventional ordered subset expectation maximization (OSEM) reconstruction method. Ninety-one patients with 144 2-[18F]FDG-avid pulmonary nodules (all ≤ 20 mm) undergoing PET/CT for oncological (re-)staging were retrospectively included. Quantitative parameters in BSREM and OSEM (including point spread function modelling) were measured, including maximum standardized uptake value (SUVmax). Nodule conspicuity in BSREM and OSEM images was evaluated by two readers. Wilcoxon matched pairs signed-rank test was used to compare quantitative and qualitative parameters in BSREM and OSEM. Pulmonary nodule SUVmax was significantly higher in BSREM images compared to OSEM images [BSREM 5.4 (1.2-20.7), OSEM 3.6 (0.7-17.4); p = 0.0001]. In a size-based analysis, the relative increase in SUVmax was more pronounced in smaller nodules (≤ 7 mm) as compared to larger nodules (8-10 mm, or > 10 mm). Lesion conspicuity was higher in BSREM than in OSEM (p < 0.0001). BSREM reconstruction results in a significant increase in SUVmax and a significantly improved conspicuity of small 2-[18F]FDG-avid pulmonary nodules compared to OSEM reconstruction. Digital 2-[18F]FDG-PET/CT reading may be enhanced with BSREM as small lesion conspicuity is improved.


Assuntos
Fluordesoxiglucose F18 , Nódulos Pulmonares Múltiplos , Algoritmos , Teorema de Bayes , Humanos , Processamento de Imagem Assistida por Computador/métodos , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos , Estudos Retrospectivos
18.
J Digit Imaging ; 35(3): 581-593, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35212859

RESUMO

The aim of the study was to analyze the use of block sequential regularized expectation maximization (BSREM) with different ß-values for the detection of brain metastases in digital fluorine-18 labeled 2-deoxy-2-fluoro-D-glucose (18F-FDG) PET/CT in lung cancer patients. We retrospectively analyzed staging/restaging 18F-FDG PET/CT scans of 40 consecutive lung cancer patients with new brain metastases, confirmed by MRI. PET images were reconstructed using BSREM (ß-values of 100, 200, 300, 400, 500, 600, 700) and OSEM. Two independent blinded readers (R1 and R2) evaluated each reconstruction using a 4-point scale for general image quality, noise, and lesion detectability. SUVmax of metastases, brain background, target-to-background ratio (TBR), and contrast recovery (CR) ratio were recorded for each reconstruction. Among all reconstruction techniques, differences in qualitative parameters were analyzed using non-parametric Friedman test, while differences in quantitative parameters were compared using analysis of variances for repeated measures. Cohen's kappa (k) was used to measure inter-reader agreement. The overall detectability of brain metastases was highest for BSREM200 (R1: 2.83 ± 1.17; R2: 2.68 ± 1.32) and BSREM300 (R1: 2.78 ± 1.23; R2: 2.68 ± 1.36), followed by BSREM100, which had lower accuracy owing to noise. The highest median TBR was found for BSREM100 (R1: 2.19 ± 1.05; R2: 2.42 ± 1.08), followed by BSREM200 and BSREM300. Image quality ratings were significantly different among reconstructions (p < 0.001). The median quality score was higher for BSREM100-300, and both noise and metastases' SUVmax decreased with increasing ß-value. Inter-reader agreement was particularly high for the detectability of photopenic metastases and blurring (all k > 0.65). BSREM200 and BSREM300 yielded the best results for the detection of brain metastases, surpassing both BSREM400 and OSEM, typically used in clinical practice.


Assuntos
Neoplasias Encefálicas , Neoplasias Pulmonares , Neoplasias Encefálicas/diagnóstico por imagem , Radioisótopos de Flúor , Fluordesoxiglucose F18 , Humanos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos , Estudos Retrospectivos
19.
Diagn Interv Imaging ; 103(5): 273-280, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34991993

RESUMO

PURPOSE: The purpose of this study was to assess whether the performances of an automated software for lung nodule detection with computed tomography (CT) are affected by radiation dose and the use of iterative reconstruction algorithm. MATERIALS AND METHODS: A chest phantom (Multipurpose Chest Phantom N1; Kyoto Kagaku Co. Ltd, Kyoto, Japan) with 15 pulmonary nodules was scanned with a total of five CT protocol settings with up to 20-fold dose reduction. All CT examinations were reconstructed with iterative reconstruction algorithms ADMIRE 3 and ADMIRE 5 and were then analyzed for the presence of pulmonary nodules with a fully automated computer aided detection software system (InferReadTM CT Lung, Infervision), which is based on deep neural networks. RESULTS: The sensitivity of fully automated pulmonary nodule detection for ground-glass nodules at standard dose CT was greater (70.0%; 14/20; 95% CI: 51.6-88.4%) than at 10-fold and 20-fold dose reduction (30.0%; 6/20; 95% CI: 0.0%-62.5%). There were less false positive findings when ADMIRE 5 reconstruction was used (4.0 ± 2.8 [SD]; range: 2-6) instead of ADMIRE 3 reconstruction (25.0 ± 15.6 [SD]; range: 14-36). There was no difference in the sensitivity of detection of solid and subsolid nodules between standard dose (100%; 95% CI: 100-100%) and 10- and 20-fold reduced dose CT (92.5%; 95% CI: 83.8-100.0%). Image noise was significantly greater with ADMIRE 3 (81 ± 2 [SD] [range: 79-84]; 104 ± 3 [SD] [range: 101-107]; 114 ± 5 [SD] [range: 110-119]; 193 ± 10 [SD] [range: 183-203]; 220 ± 16 [SD] [range: 210-238]) compared to ADMIRE 5 (44 ± 2 [SD] [range: 42-46]; 60 ± 2 [SD] [range: 57-61]; 66 ± 1 [SD] [range: 65-67]; 103 ± 4 [SD] [range: 98-106]; 110 ± 1 [SD] [range: 109-111]), respectively in each of the five CT protocols. CONCLUSION: This phantom study suggests that dose reduction and iterative reconstruction settings have an impact on detectability of pulmonary nodules by artificial intelligence software and we therefore encourage adaption of dose levels and reconstruction methods prior to widespread implementation of fully automatic nodule detection software for lung cancer screening purposes.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Algoritmos , Inteligência Artificial , Redução da Medicação , Detecção Precoce de Câncer , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos
20.
Clin Nucl Med ; 47(2): 101-107, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35006103

RESUMO

BACKGROUND: The aim of this study was to assess the relationship between the histopathological properties of hyperfunctioning parathyroids and parathyroid 18F-choline uptake. PATIENTS AND METHODS: A total of 31 parathyroid adenomas were retrospectively analyzed in patients with primary hyperparathyroidism and preoperative 18F-choline PET/MR. PET/MR parameters of parathyroid glands (SUVmax and target-to-background ratio in early-phase [EP] and late-phase [LP]), MRI volume, preoperative parathyroid hormone (PTH) serum concentration, and postoperative histopathology (predominant cell type and growth pattern of adenoma cells, location and size of adenoma) were assessed. The relationship of PET/MR parameters, PTH, and histological parameters was determined using linear regression, Spearman correlation and Kruskal-Wallis test. RESULTS: The median volume of parathyroid adenoma was 421.78 ± 142.46 mm3 (46.39-4412.69). Adenomas were predominantly composed of chief, water-clear, and oncocytic/oxyphilic cells in 27/31, 2/31, and 2/31 cases, respectively. The growth pattern was predominantly solid, follicular, and trabecular in 18/31, 8/31, and 5/31, respectively. The SUVmax was 6.71 ± 3.39 in EP and 6.91 ± 3.97 in LP. Follicular growth pattern had slightly higher EP SUVmax (trabecular: 4.12 ± 0.56; solid: 6.62 ± 3.19; follicular: 8.56 ± 3.96; P = 0.046). Spearman correlation showed strong positive correlation between volume and both EP and LP SUVmax (0.626; P = 0.0001 and 0.576; P = 0.0001, respectively). Linear regression analysis revealed significant correlation between PTH level and EP and LP SUVmax (both P = 0.001); in contrast, no correlation was found between PTH level and both cell type and growth pattern. CONCLUSIONS: Our findings suggest that 18F-choline uptake of parathyroid adenomas might be associated both with the histological growth pattern and adenoma volume, but not with a specific cell type.


Assuntos
Hiperparatireoidismo Primário , Neoplasias das Paratireoides , Colina/análogos & derivados , Humanos , Imageamento por Ressonância Magnética , Glândulas Paratireoides , Hormônio Paratireóideo , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA