Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38310332

RESUMO

OBJECTIVES: The aortic root (AoR) rotation and its spatial morphology at the base of the heart were postulated but not described in every detail. AoR rotation modalities may play an important role in decision-making during AoR surgery and its outcome. The aim was to provide a detailed spatial anatomy of the AoR rotation and its relation to the vital surrounding structure. METHODS: The AoR rotation and its relation to the surrounding structure were assessed in 104 patients with tricuspid aortic valve. The interatrial septum was chosen as a reference to describe AoR rotation that marked the midline of the heart base as a landmark for the AoR rotation direction. Intermediate, clockwise and counterclockwise AoR rotations were defined based on the mentioned reference structures. RESULTS: The AoR rotation was successfully assessed in 104 patients undergoing ascending aorta and or AoR intervention by multidetector row computed tomography. AoR was positioned normally in 53.8% of cases (n = 56) and rotated counterclockwise in 5.8% (n = 6) and clockwise in 40.4% (n = 42) of cases. In clockwise AoR rotation, the right coronary sinus was positioned in proximity to the right atrium and of the tricuspid valve, whereas in a counterclockwise rotation, the noncoronary sinus was placed over the tricuspid valve just over the membranous septum. CONCLUSIONS: The AoR's rotation can be diagnosed using multidetector row computed tomography. Understanding the anatomy of the aortic valve related to rotational position helps guide surgical decision-making in performing AoR reconstruction.


Assuntos
Aorta Torácica , Aorta , Humanos , Aorta/cirurgia , Valva Aórtica/cirurgia , Valva Tricúspide , Tomografia Computadorizada Multidetectores
2.
J Clin Med ; 12(21)2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37959355

RESUMO

We present the results of a combined approach for transapical aortic valve replacement and minimally invasive coronary artery bypass grafting (taTAVI-MIDCAB) in patients with combined aortic stenosis and coronary artery disease. BACKGROUND: For patients presenting with aortic stenosis and coronary artery disease, a simultaneous procedure addressing both diseases is recommended to reduce operative risk. In high-risk patients with hostile femoral or coronary axis, taTAVI-MIDCAB can be an alternative minimally invasive approach, offering the benefits of left interior mammary artery to left anterior descending coronary artery (LIMA-LAD) grafting. METHODS: From 2014 to 2022, 10 patients underwent taTAVI-MIDCAB for combined coronary and severe aortic stenosis in the hybrid operation theater at our institution. We assessed perioperative outcomes and follow-up outcomes. RESULTS: The median age was 83 years (81 to 86). The procedure was successfully performed in all patients without conversion to sternotomy. The median length of hospital and intensive care unit stay was 9 days (7 to 16) and 2.5 days (1 to 5), respectively. The median flow over the coronary artery bypass was 31 (22 to 44) mL/min, with a pulsatility index (PI) of 2.4 (2.1 to 3.2). Mild paravalvular leak occurred in 2 patients (10%). There were no neurological events nor acute kidney injury. Pacemaker implantation was required in 1 patient (10%). CONCLUSIONS: Simultaneous surgical coronary revascularization and interventional valve implantation in the setting of a hostile femoral and coronary axis appears to be safe and beneficial.

3.
Front Cardiovasc Med ; 10: 1273785, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37886733

RESUMO

Introduction: The impact of sex on hospital readmission rate after cardiac surgery is unclear. Therefore, we aimed to analyse sex-specific differences and underlying factors in 30-day readmission rate after cardiac surgery. Methods: We conducted a single center study including all patients after major cardiac surgery (excluding aortic dissection and left ventricular assist device implantation) from January 2012 to September 2020. Reasons for readmission were adjudicated according to all available medical records. We calculated incidence rate ratios (IRR) with 95% confidence intervals (CI) for female sex with re-admission crude and adjusted for plausible confounding factors using negative binomial regression. Results: 4,868 patients were included in the analysis. The median [Interquartile range] age was 68 [60 to 74] years and 24% (n = 1,149) of the patients were female. Female patients were significantly older (median [IQR] age 70 (63 to 76) vs. 67 (59 to 74), p < 0.001) and had lower body mass index and fewer cardiovascular risk factors compared to men. Isolated valve surgery was more frequent in female while coronary artery bypass grafting was more often in men. 30-day readmission was comparable between both sexes (7.0% [n = 81] in female vs. 8.7% [n = 322] in men; p = 0.078). Cardiac related readmissions and infections were the most common reasons for readmission in both groups. The overall incidence rate ratios of female sex with readmission (0.80, 95% CI 0.63 to 1.03, p = 0.078) remained robust after adjustment for EuroSCORE 2 (0.78, CI 0.61 to 1.0, p = 0.051). Conclusion: Readmission rate and reasons for 30-day readmission after major cardiac surgery were similar between men and women.

4.
Biomedicines ; 11(7)2023 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-37509585

RESUMO

Due to the advent of interventional therapies for low- and intermediate-risk patients, case complexity has increased in cardiac surgery over the last decades. Despite the surgical progress achieved to keep up with the increase in the number of high-risk patients, the prevention of sternal complications remains a challenge requiring new, individualized sternal closure techniques. The aim of this study was to evaluate the safety and feasibility, as well as the in-hospital and long-term outcomes, of enhanced sternal closure with combined band and plate fixation using the new SternaLock® 360 (SL360) system as an alternative to sternal wiring. From 2020 to 2022, 17 patients underwent enhanced sternal closure using the SL360 at our institution. We analyzed perioperative data, as well as clinical and radiologic follow-up data. The results were as follows: In total, 82% of the patients were treated with the SL360 based on perioperative risk factors, while in 18% of cases, the SL360 was used for secondary closure due to sternal instability. No perioperative complications were observed. We obtained the follow-up data of 82% of the patients (median follow-up time: 141 (47.8 to 511.5) days), showing no surgical revision, no sternal instability, no deep wound infections, and no sternal pain at the follow-up. In one case, a superficial wound infection was treated with antibiotics. In conclusion, enhanced sternal closure with the SL360 is easy to perform, effective, and safe. This system might be considered for both primary and secondary sternal closure in patients at risk of sternal complications.

5.
Can J Cardiol ; 39(7): 990-996, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37062486

RESUMO

BACKGROUND: We aimed to assess the outcomes of the minimally invasive nonresectional technique over 10 years in patients with severe mitral valve insufficiency. METHODS: A retrospective analysis of 365 patients undergoing a minimally invasive complete endoscopic mitral valve repair for mitral valve insufficiency was conducted between May 2009 and September 2021. All patients underwent the nonresectional repair approach using artificial neochordae implantation or ring annuloplasty. Clinical and echocardiographic follow-ups were performed. RESULTS: The minimal invasive procedure was successfully performed in all patients. The mean age was 61 ± 11, and 36% were female patients. The surgical success was 99.7%, with no conversion to sternotomy or to mitral valve replacement at 30 days. In 1 case (0.27%), mitral valve related reoperation was performed during the hospital stay. The procedural safety was 92%, with in-hospital mortality in 0.55% (n = 2), stroke in 0.55% (n = 2), and perioperative myocardial infarction in 0.82% (n = 3) patients. The mean follow up was 5.3 ± 2.9 years. Survival at 5 and 10 years was 96% (95% confidence interval [CI], 94%-98%) and 83% (95% CI, 72%-90%). Freedom of myocardial infarction, stroke, and congestive heart failure at 10 years was 95% (95% CI, 88%-98%), 86% (95% CI, 75%-92%), and 93% (95% CI, 89%-96%), respectively. Recurrent mitral valve insufficiency ≥ + 2 was diagnosed in 4.9% of cases. CONCLUSIONS: Minimally invasive nonresectional mitral valve repair technique can be performed for severe mitral valve regurgitation with excellent long-term results. The procedure is safe, with minimal risk of reoperation and recurrent mitral valve insufficiency at long term.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Infarto do Miocárdio , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Infarto do Miocárdio/cirurgia , Implante de Prótese de Valva Cardíaca/métodos
7.
J Clin Med ; 11(24)2022 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-36556103

RESUMO

Background: We aimed to analyse the performance of minimal invasive extracorporeal circulation (MiECC) concomitantly with Microplegia, in patients with recent myocardial infarction (MI) undergoing urgent coronary artery bypass grafting (CABG) surgery. Methods: We included patients with a recent MI (≤7 days) undergoing isolated CABG surgery using MiECC. The primary endpoint was a major cardiovascular or cerebrovascular event (MACCE). In a secondary analysis, we compared our institutional Microplegia concept with the use of a crystalloid single-shot cardioplegic solution. Results: In total, 139 patients (mean ± standard deviation (SD) age 66 ± 10 years) underwent urgent CABG surgery using Microplegia; 55% (n = 77) of the patients had an acute MI within 1−7 days preoperatively; 20% (n = 28) had an acute MI within 6−24 h; and 24% (n = 34) had an acute MI within <6 h preoperatively. The number of distal anastomoses was a geometric mean of 4 (95% confidence interval 3−4). The MACCE and in-hospital mortality were 7% (n = 10) and 1% (n = 2), respectively. The results were confirmed in a secondary analysis comparing Microplegia with crystalloid cardioplegic solution (n = 271). Conclusion: The use of MiECC with Microplegia in urgent CABG surgery is feasible and safe and provides a straight-forward intraoperative setting. Therefore, it can also be considered to retain the benefits of MiECC in urgent CABG surgery.

8.
Eur J Cardiothorac Surg ; 62(1)2022 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-35678570

RESUMO

We present the case of a 78-year-old woman suffering from coronary artery disease and secondary severe mitral valve regurgitation due to left ventricular and annular distention. The interdisciplinary heart team recommended a simultaneous hybrid procedure consisting of minimally invasive direct coronary artery bypass grafting with subsequent transapical mitral valve replacement using the Tendyne prosthesis via the same small anterolateral thoracotomy. The operation was performed using a heart-team approach with close collaboration between heart surgeons and cardiologists in the hybrid operating theatre. The intra- and postoperative courses were uneventful. Predischarge transthoracic echocardiography on postoperative day 8 revealed the immaculate functioning of the implanted valve without para- or transvalvular insufficiency, a mean gradient of 2 mmHg, no left ventricular outflow tract obstruction and a stable ejection fraction of 50%. The combination of minimally invasive direct coronary artery bypass grafting revascularization with concomitant transapical mitral valve replacement is feasible and enables a further step towards minimally invasive therapy, even in complex situations. It shows that the modern heart-team approach exceeds mere decision making and expands towards a hybrid treatment for patients.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Idoso , Ponte de Artéria Coronária , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Toracotomia/métodos , Resultado do Tratamento , Disfunção Ventricular Esquerda/cirurgia
9.
Eur J Cardiothorac Surg ; 62(2)2022 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-35758627

RESUMO

A 78-year-old patient underwent his third biological aortic valve replacement (25 mm, Inspiris Resilia™, Edwards Lifesciences LLC, Irvine, CA, USA) with COR-KNOT® (LSI Solutions, Victor, NY, USA) due to valve degeneration in 2018 at a foreign hospital. In 2021, the patient was diagnosed with severe aortic regurgitation and admitted to our hospital for his fourth surgery. Intraoperatively, a total of 7 perforations in all 3 valve leaflets have been observed, which were obviously induced by the rigid metallic fasteners. Redo isolated aortic valve replacement (29 mm, Perimount Magna Ease, Edwards Lifesciences LLC) was performed with conventionally knotted, pledget enforced braided threads. Postoperative course was uneventful. This report shows that COR-KNOT-induced defects do not appear immediately after surgery but within the first 4 postoperative months. Since failure of aortic bioprostheses due to aortic insufficiency is often rated as 'early degeneration' and degenerated aortic bioprostheses are mostly replaced by valve-in-valve strategy, the true incidence of this serious complication might be underestimated. COR-KNOT should be used with caution in biological aortic valve replacement and patients should undergo close postoperative follow-ups.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Desenho de Prótese , Titânio/efeitos adversos , Resultado do Tratamento
10.
ESC Heart Fail ; 9(4): 2703-2712, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35438261

RESUMO

AIMS: New-onset atrial fibrillation (NOAF) is the most common complication after cardiac surgery, occurring in 25-50% of patients. It is associated with post-operative stroke, increased mortality, prolonged hospital length of stay, and higher treatment costs. Previous small observational studies have identified the left atrium as a source of the electrical rotors and foci maintaining NOAF, but confirmation by a large prospective clinical study is still missing. The aim of the proposed study is to investigate whether the source of NOAF lies in the left atrium. The correct identification of NOAF-maintaining structures in cardiac surgical patients might offer potential therapeutic targets for prophylactic perioperative ablation strategies. METHODS AND RESULTS: This is a prospective single-centre observational study of patients developing NOAF after cardiac surgery. The primary outcome is the description of NOAF-maintaining structures within the atria. Key secondary outcomes include overall mortality, intensive care unit length of stay, hospital-ventilator-free days, and proportion of persistent NOAF. In NOAF patients, the non-invasive electrophysiological mapping will be conducted using a 252-electrode electrocardiogram vest. After mapping, a low-dose computed tomography scan of the chest will be performed to integrate the electrophysiological mapping results into a 3D picture of the heart. The study will include approximately 570 patients, of whom 30% (n = 170) are expected to develop NOAF. Sample size calculation revealed that 157 NOAF patients are necessary to assess the primary outcome. Patients will be tracked for a total of 5 years. CONCLUSIONS: This is the largest prospective study to date describing the electrophysiological mechanisms of NOAF using non-invasive mapping.


Assuntos
Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Fibrilação Atrial/complicações , Fibrilação Atrial/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Eletrocardiografia , Humanos , Estudos Observacionais como Assunto , Estudos Prospectivos , Fatores de Risco
11.
J Clin Med ; 10(4)2021 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-33546164

RESUMO

BACKGROUND: Aim of this study was to evaluate the outcomes of endocarditis patients undergoing valve surgery with the Cytosorb® hemoadsorption (HA) device during cardiopulmonary bypass. METHODS: From 2009 until 2019, 241 patients had undergone valve surgery due to endocarditis at the Department of Cardiac Surgery, University Hospital of Basel. We compared patients who received HA during surgery (n = 41) versus patients without HA (n = 200), after applying inverse probability of treatment weighting. RESULTS: In-hospital mortality, major adverse cardiac and cerebrovascular events and postoperative renal failure were similar in both groups. Demand for norepinephrine (88.4 vs. 52.8%; p = 0.001), milrinone (42.2 vs. 17.2%; p = 0.046), red blood cell concentrates (65.2 vs. 30.6%; p = 0.003), and platelets (HA vs. Control: 36.7 vs. 9.8%; p = 0.013) were higher in the HA group. In addition, a higher incidence of reoperation for bleeding (34.0 vs. 7.7 %; p = 0.011), and a prolonged length of in-hospital stay (15.2 (11.8 to 19.6) vs. 9.0 (7.1 to 11.3) days; p = 0.017) were observed in the HA group. CONCLUSIONS: No benefits of HA-therapy were observed in patients with infective endocarditis undergoing valve surgery.

12.
World J Surg ; 44(9): 3175-3181, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32458022

RESUMO

INTRODUCTION: Mid-term data from a single centre showed the safety and durability of aortic valve neocuspidization using autologous pericardium (OZAKI procedure). Since validation data from other centres are missing, aim of this study was to analyze echocardiographic and clinical results of our first patients that were operated with the OZAKI technique. METHODS: Thirty-five patients (24 males, median (IQR) age 72.0 (59.0, 76.0) years) with aortic stenosis (AS; n = 10), aortic insufficiency (AR; n = 13) or a combination of both (AS/AR; n = 12), underwent aortic valve neocuspidization in our institution between September 2015 and May 2017. Echocardiographic follow-up was performed using a standardized examination protocol. RESULTS: Clinical follow-up was completed in 97% of the patients. Median (IQR) follow-up time was 645 (430, 813) days. Mortality rate was 9% (n = 1: aspiration pneumonia; n = 1: unknown; n = 1: anaphylactic shock), and the reoperation rate was 3% (n = 1: endocarditis). No pacemaker implantation was necessary after isolated OZAKI procedures. Echocardiographic follow-up was performed in 83% of the patients (n = 29; median (IQR) time 664 (497, 815) days). Median (IQR) mean and peak gradients were 6 (5,9) mmHg and 12 (8, 17) mmHg. Moderate aortic regurgitation was seen in 2 patients (7%). No severe aortic regurgitation or moderate or severe aortic stenosis occurred within the follow-up period. CONCLUSIONS: The OZAKI procedure is reliable and reoperation due to structural valve deterioration nil within a median 645 days follow-up period. The low rate of moderate aortic regurgitation will be surveilled very closely. Further studies are required to evaluate the significance of this procedure in aortic valve surgery. CLINICAL REGISTRATION NUMBER: ClinicalTrials.gov (ID NCT03677804).


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Ecocardiografia/métodos , Pericárdio/transplante , Idoso , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Transplante Autólogo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA