Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Clin J Am Soc Nephrol ; 7(10): 1664-72, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22977214

RESUMO

Estimates suggest that one third of United States health care spending results from overuse or misuse of tests, procedures, and therapies. The American Board of Internal Medicine Foundation, in partnership with Consumer Reports, initiated the "Choosing Wisely" campaign to identify areas in patient care and resource use most open to improvement. Nine subspecialty organizations joined the campaign; each organization identified five tests, procedures, or therapies that are overused, are misused, or could potentially lead to harm or unnecessary health care spending. Each of the American Society of Nephrology's (ASN's) 10 advisory groups submitted recommendations for inclusion. The ASN Quality and Patient Safety Task Force selected five recommendations based on relevance and importance to individuals with kidney disease.Recommendations selected were: (1) Do not perform routine cancer screening for dialysis patients with limited life expectancies without signs or symptoms; (2) do not administer erythropoiesis-stimulating agents to CKD patients with hemoglobin levels ≥10 g/dl without symptoms of anemia; (3) avoid nonsteroidal anti-inflammatory drugs in individuals with hypertension, heart failure, or CKD of all causes, including diabetes; (4) do not place peripherally inserted central catheters in stage 3-5 CKD patients without consulting nephrology; (5) do not initiate chronic dialysis without ensuring a shared decision-making process between patients, their families, and their physicians.These five recommendations and supporting evidence give providers information to facilitate prudent care decisions and empower patients to actively participate in critical, honest conversations about their care, potentially reducing unnecessary health care spending and preventing harm.


Assuntos
Medicina Baseada em Evidências , Promoção da Saúde , Mau Uso de Serviços de Saúde/prevenção & controle , Nefrologia , Indicadores de Qualidade em Assistência à Saúde , Insuficiência Renal Crônica/terapia , Anti-Inflamatórios não Esteroides/efeitos adversos , Cateterismo Venoso Central , Redução de Custos , Análise Custo-Benefício , Medicina Baseada em Evidências/economia , Medicina Baseada em Evidências/normas , Fidelidade a Diretrizes , Custos de Cuidados de Saúde , Mau Uso de Serviços de Saúde/economia , Hematínicos/uso terapêutico , Humanos , Programas de Rastreamento/métodos , Nefrologia/economia , Nefrologia/normas , Segurança do Paciente , Relações Médico-Paciente , Guias de Prática Clínica como Assunto , Relações Profissional-Família , Desenvolvimento de Programas , Indicadores de Qualidade em Assistência à Saúde/economia , Indicadores de Qualidade em Assistência à Saúde/normas , Diálise Renal , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/economia , Sociedades Médicas , Estados Unidos
2.
Nat Clin Pract Nephrol ; 2(2): 92-100, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16932400

RESUMO

Intravenous iron is necessary for optimal management of anemia in patients receiving hemodialysis and is utilized in the majority of these patients in the US. The availability of nondextran formulations of intravenous iron has significantly improved the safety of its use. The nondextran iron formulation sodium ferric gluconate complex (SFGC) has been extensively studied in the hemodialysis population, with two large phase IV trials documenting its safety. SFGC is efficacious and, at recommended doses, is associated with a low incidence of adverse events. There have been few comparative studies of the nondextran intravenous iron preparations; however, they are known to have different pharmacokinetic characteristics. There is also evidence to indicate that these compounds differ in terms of their cytotoxic and proinflammatory properties, and their propensity to induce oxidative stress. This paper reviews the current literature on the safety of SFGC and examines the emerging safety issues surrounding the use of intravenous iron.


Assuntos
Compostos Férricos/administração & dosagem , Hematínicos/administração & dosagem , Ferro/administração & dosagem , Diálise Renal , Compostos Férricos/efeitos adversos , Hematínicos/efeitos adversos , Humanos , Injeções Intravenosas , Ferro/efeitos adversos , Segurança
3.
J Am Soc Nephrol ; 16(10): 3070-80, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16033854

RESUMO

The independent association between the indices of iron stores or administered intravenous iron, both of which vary over time, and survival in patients who are on maintenance hemodialysis (MHD) is not clear. It was hypothesized that the observed associations between moderately high levels of three iron markers (serum ferritin, iron, and iron saturation ratio) or administered intravenous iron and all-cause and cardiovascular death is due to the time-varying confounding effect of malnutrition-inflammation-cachexia syndrome (MICS). Time-dependent Cox regression models were examined using prospectively collected data of the 2-yr (July 2001 to June 2003) historical cohort of 58,058 MHD patients from virtually all DaVita dialysis clinics in the United States. After time-dependent and multivariate adjustment for case mix, administered intravenous iron and erythropoietin doses, and available surrogates of MICS, serum ferritin levels between 200 and 1200 ng/ml (reference 100 to 199 ng/ml), serum iron levels between 60 and 120 microg/ml (reference 50 to 59 microg/ml), and iron saturation ratio between 30 and 50% (reference 45 to 50%) were associated with the lowest all-cause and cardiovascular death risks. Compared with those who did not receive intravenous iron, administered intravenous iron up to 400 mg/mo was associated with improved survival, whereas doses >400 mg/mo tended to be associated with higher death rates. The association between serum ferritin levels >800 ng/ml and mortality in MHD patients seems to be due mostly to the confounding effects of MICS. For ascertaining whether the observed associations between moderate doses of administered intravenous iron and improved survival are causal or due to selection bias by indication, clinical trials are warranted.


Assuntos
Ferro/sangue , Ferro/uso terapêutico , Diálise Renal/mortalidade , Doenças Cardiovasculares/mortalidade , Feminino , Ferritinas/sangue , Humanos , Inflamação/complicações , Inflamação/mortalidade , Ferro/metabolismo , Masculino , Desnutrição/complicações , Desnutrição/mortalidade , Pessoa de Meia-Idade , Fatores de Risco , Taxa de Sobrevida , Fatores de Tempo
4.
Kidney Int ; 63(1): 217-24, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12472786

RESUMO

BACKGROUND: Iron dextran administration is associated with a high incidence of adverse reactions including anaphylaxis and death. Although dextran, rather than iron, is believed to be the cause of these reactions, it is not known whether iron dextran-sensitive patients can be safely administered another form of parenteral iron, sodium ferric gluconate in sucrose (SFGC). METHODS: In a 69 center, prospective, double-blind, controlled trial of safety and tolerability of SFGC, the rate of reactions to SFGC and placebo in 144 iron dextran-sensitive patients was compared with 2194 patients who were previously tolerant to iron dextran preparations. Serum tryptase levels, a marker of mast cell degranulation, also were measured. RESULTS: Among 143 iron dextran-sensitive patients exposed to SFGC, three (2.1%) were intolerant. All three had suspected allergic events to SFGC, including one patient with a serious reaction (0.7%). One dextran-sensitive patient (0.7%) had a suspected allergic reaction after placebo. In contrast, among 2194 iron dextran-tolerant patients, reactions to SFGC were significantly less common, with SFGC intolerance seen in seven patients (0.3%; P = 0.020), including five (0.2%) who had suspected allergic events (P = 0.010), but none who had serious events (0.0%; P = 0.061). Two iron dextran-tolerant patients (0.09%) had allergic-like reactions following placebo injections. Two of the three suspected allergic events in the iron dextran-sensitive group were confirmed as mast cell dependent by a 100% increase in serum tryptase, while there were no confirmed allergic events in the iron dextran-tolerant group. Long-term exposure to SFGC in iron dextran-sensitive patients resulted in intolerance in only one additional patient and no serious adverse events. CONCLUSIONS: Patients with a history of iron dextran sensitivity had approximately sevenfold higher rates of reaction to both placebo and SFGC compared to iron dextran tolerant patients. However, logistic regression analysis, performed to account for the higher reaction rate to placebo, suggests that this increased reactivity was not drug-specific nor immunologically mediated, but represented host idiosyncrasy. These results support the conclusions that reactions to SFGC can be attributed to pseudoallergy, and that SFGC is not a true allergen.


Assuntos
Compostos Férricos/efeitos adversos , Complexo Ferro-Dextran/efeitos adversos , Falência Renal Crônica/tratamento farmacológico , Diálise Renal , Hipersensibilidade a Drogas/imunologia , Feminino , Compostos Férricos/administração & dosagem , Compostos Férricos/imunologia , Humanos , Complexo Ferro-Dextran/administração & dosagem , Complexo Ferro-Dextran/imunologia , Falência Renal Crônica/imunologia , Masculino , Mastócitos/imunologia , Pessoa de Meia-Idade , Estudos Prospectivos , Serina Endopeptidases/sangue , Sacarose , Triptases
5.
Kidney Int ; 61(5): 1830-9, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-11967034

RESUMO

BACKGROUND: Parenteral iron is often required by hemodialysis patients to maintain adequate iron stores. Until recently, the only available form of intravenous iron was iron dextran, which is associated with significant adverse reactions, including anaphylaxis and death. Sodium ferric gluconate complex (SFGC) was recently approved for use in the U.S. under FDA's priority drug review. This Phase IV study was designed to evaluate the safety of a single dose of intravenous SFGC as compared to placebo and a historical iron dextran control. METHODS: This multicenter, crossover, randomized, double blind, placebo-controlled prospective comparative study was performed in hemodialysis patients requiring at least 125 mg of elemental iron. The historical control was obtained from a meta-analysis of four publications examining outcomes in patients exposed to iron dextran. SFGC naïve patients were administered SFGC without a test dose, undiluted, at a rate of 125 mg over 10 minutes, and compared to placebo comprising bacteriostatic saline. RESULTS: A total of 2534 patients were enrolled. The incidence of drug intolerance (an adverse event precluding re-exposure) was significantly less [0.44%, confidence interval (CI) 0.21 to 0.71%] after SFGC as compared to the iron dextran control (2.47%, CI 1.87 to 3.07%, P < 0.0001), but higher than after placebo (0.1%, P = 0.02). There was no difference found between SFGC and placebo in serious adverse events. A single life-threatening event occurred after SFGC (0.04%, CI 0.00 to 0.22%), which was significantly less than following iron dextran (0.61%, CI 0.36 to 0.86%), P = 0.0001. CONCLUSION: SFGC is well tolerated when given by intravenous push without a test dose. SFGC has a significantly lower incidence of drug intolerance and life-threatening events as compared to previous studies using iron dextran. The routine use of iron dextran in hemodialysis patients should be discontinued.


Assuntos
Anemia Ferropriva/tratamento farmacológico , Compostos Férricos/efeitos adversos , Complexo Ferro-Dextran/efeitos adversos , Falência Renal Crônica/complicações , Diálise Renal , Adulto , Idoso , Idoso de 80 Anos ou mais , Anafilaxia/induzido quimicamente , Anemia Ferropriva/etiologia , Inibidores da Enzima Conversora de Angiotensina/administração & dosagem , Estudos Cross-Over , Método Duplo-Cego , Feminino , Compostos Férricos/administração & dosagem , Humanos , Hipotensão/induzido quimicamente , Injeções Intravenosas , Complexo Ferro-Dextran/administração & dosagem , Masculino , Pessoa de Meia-Idade , Placebos , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA