Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Am J Ophthalmol Case Rep ; 25: 101394, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35198818

RESUMO

PURPOSE: To report the impact of intravitreal anti-vascular endothelial growth factor (VEGF) therapy on a retinal capillary hemangioma (RCH) using clinical OCT angiography (OCT-A) in addition to standard imaging modalities. OBSERVATIONS: A 25-year-old male patient with Von Hippel-Lindau (VHL) disease presented with a history of bilateral RCH. No view was present in the right eye. Examination of the left eye revealed six peripheral RCH, the smallest of which was temporal to the macula with active exudation. This RCH was thought to be the source of cystoid macular edema (CME) involving the fovea, and therefore, the source of vision decline. 11 injections of 1.25mg of Bevacizumab EA across 14-month was given. Comparison of the pre- and post-treatment OCT-A at the temporal RCH showed a reduction of CME and regression of RCH. CONCLUSION: Anti-VEGF therapy appeared to stabilize the visual acuity and produce partial regression of RCH. It offers a safe option when visual acuity is threatened. OCT and OCT-A have the ability to document the impact of antiangiogenic therapy on RCH. 3D renderings of OCT-A offer enhanced sensitivity to recognition of structural and functional changes of RCH which may prove useful for monitoring treatment response.

2.
Invest Ophthalmol Vis Sci ; 61(6): 48, 2020 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-32574351

RESUMO

Purpose: To image retinal macrophages at the vitreoretinal interface in the living human retina using a clinical optical coherence tomography (OCT) device. Methods: Eighteen healthy controls and three patients with retinopathies were imaged using a clinical spectral-domain OCT. In controls, 10 sequential scans were collected at three different locations: (1) ∼9 degrees temporal to the fovea, (2) the macula, and (3) the optic nerve head (ONH). Intervisit repeatability was evaluated by imaging the temporal retina twice on the same day and 3 days later. Only 10 scans at the temporal retina were obtained from each patient. A 3-µm OCT reflectance (OCT-R) slab located above the inner limiting membrane (ILM) surface was averaged. Results: In controls, ramified macrophage-like cells with regular spatial separation were visualized in the temporal and ONH OCT-R images; however, cell structures were not resolvable at the macula. Interim changes in cell position suggestive of cell translocation were observed between images collected on the same day and those collected 3 days later. There was considerable variation in cell density and nearest-neighbor distance (NND) across controls. Mean ± SD cell densities measured at the temporal and ONH were 78 ± 23 cells/mm2 and 57 ± 16 cells/mm2, respectively. Similarly, mean ± SD NNDs measured at the temporal and ONH were 74.3 ± 13.3 µm and 93.3 ± 20.0 µm, respectively. Nonuniform spatial distribution and altered morphology of the cells were identified in patients with retinopathies. Conclusions: Our findings showed regular spatial separation and ramified morphology of macrophage-like cells on the ILM surface with cell translocation over time in controls. Their distribution and morphology suggest an origin of macrophage-like cells such as microglia or hyalocytes.


Assuntos
Macrófagos/patologia , Disco Óptico/patologia , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos , Adulto , Feminino , Humanos , Masculino , Fibras Nervosas/patologia , Adulto Jovem
3.
Transl Vis Sci Technol ; 4(4): 1, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26175961

RESUMO

PURPOSE: To characterize the first in-human intraoperative imaging using a custom prototype spectral-domain microscope-integrated optical coherence tomography (MIOCT) device during vitreoretinal surgery with instruments in the eye. METHODS: Under institutional review board approval for a prospective intraoperative study, MIOCT images were obtained at surgical pauses with instruments held static in the vitreous cavity and then concurrently with surgical maneuvers. Postoperatively, MIOCT images obtained at surgical pauses were compared with images obtained with a high-resolution handheld spectral-domain OCT (HHOCT) system with objective endpoints, including acquisition of images acceptable for analysis and identification of predefined macular morphologic or pathologic features. RESULTS: Human MIOCT images were successfully obtained before incision and during pauses in surgical maneuvers. MIOCT imaging confirmed preoperative diagnoses, such as epiretinal membrane, full-thickness macular hole, and vitreomacular traction and demonstrated successful achievement of surgical goals. MIOCT and HHOCT images obtained at surgical pauses in two cohorts of five patients were comparable with greater than or equal to 80% correlation in 80% of patients. Real-time video-imaging concurrent with surgical manipulations enabled, for the first time using this device, visualization of dynamic instrument-retina interaction with targeted OCT tracking. CONCLUSION: MIOCT is successful for imaging at surgical pauses and for real-time image guidance with implementation of targeted OCT tracking. Even faster acquisition speeds are currently being developed with incorporation of a swept-source MIOCT engine. Further refinements and investigations will be directed toward continued integration for real-time volumetric imaging of surgical maneuvers. TRANSLATIONAL RELEVANCE: Ongoing development of seamless MIOCT systems will likely transform surgical visualization, approaches, and decision-making.

4.
Retina ; 33(7): 1328-37, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23538579

RESUMO

PURPOSE: The authors have recently developed a high-resolution microscope-integrated spectral domain optical coherence tomography (MIOCT) device designed to enable OCT acquisition simultaneous with surgical maneuvers. The purpose of this report is to describe translation of this device from preclinical testing into human intraoperative imaging. METHODS: Before human imaging, surgical conditions were fully simulated for extensive preclinical MIOCT evaluation in a custom model eye system. Microscope-integrated spectral domain OCT images were then acquired in normal human volunteers and during vitreoretinal surgery in patients who consented to participate in a prospective institutional review board-approved study. Microscope-integrated spectral domain OCT images were obtained before and at pauses in surgical maneuvers and were compared based on predetermined diagnostic criteria to images obtained with a high-resolution spectral domain research handheld OCT system (HHOCT; Bioptigen, Inc) at the same time point. Cohorts of five consecutive patients were imaged. Successful end points were predefined, including ≥80% correlation in identification of pathology between MIOCT and HHOCT in ≥80% of the patients. RESULTS: Microscope-integrated spectral domain OCT was favorably evaluated by study surgeons and scrub nurses, all of whom responded that they would consider participating in human intraoperative imaging trials. The preclinical evaluation identified significant improvements that were made before MIOCT use during human surgery. The MIOCT transition into clinical human research was smooth. Microscope-integrated spectral domain OCT imaging in normal human volunteers demonstrated high resolution comparable to tabletop scanners. In the operating room, after an initial learning curve, surgeons successfully acquired human macular MIOCT images before and after surgical maneuvers. Microscope-integrated spectral domain OCT imaging confirmed preoperative diagnoses, such as full-thickness macular hole and vitreomacular traction, and demonstrated postsurgical changes in retinal morphology. Two cohorts of five patients were imaged. In the second cohort, the predefined end points were exceeded with ≥80% correlation between microscope-mounted OCT and HHOCT imaging in 100% of the patients. CONCLUSION: This report describes high-resolution MIOCT imaging using the prototype device in human eyes during vitreoretinal surgery, with successful achievement of predefined end points for imaging. Further refinements and investigations will be directed toward fully integrating MIOCT with vitreoretinal and other ocular surgery to image surgical maneuvers in real time.


Assuntos
Microscopia/instrumentação , Monitorização Intraoperatória/instrumentação , Doenças Retinianas , Cirurgia Assistida por Computador/métodos , Tomografia de Coerência Óptica/instrumentação , Atitude do Pessoal de Saúde , Técnicas de Diagnóstico Oftalmológico , Humanos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Doenças Retinianas/diagnóstico , Doenças Retinianas/cirurgia , Inquéritos e Questionários , Tomografia de Coerência Óptica/métodos
5.
Graefes Arch Clin Exp Ophthalmol ; 251(1): 213-20, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22585009

RESUMO

BACKGROUND: We have recently developed a microscope-integrated spectral-domain optical coherence tomography (MIOCT) device towards intrasurgical cross-sectional imaging of surgical maneuvers. In this report, we explore the capability of MIOCT to acquire real-time video imaging of vitreoretinal surgical maneuvers without post-processing modifications. METHODS: Standard 3-port vitrectomy was performed in human during scheduled surgery as well as in cadaveric porcine eyes. MIOCT imaging of human subjects was performed in healthy normal volunteers and intraoperatively at a normal pause immediately following surgical manipulations, under an Institutional Review Board-approved protocol, with informed consent from all subjects. Video MIOCT imaging of live surgical manipulations was performed in cadaveric porcine eyes by carefully aligning B-scans with instrument orientation and movement. Inverted imaging was performed by lengthening of the reference arm to a position beyond the choroid. RESULTS: Unprocessed MIOCT imaging was successfully obtained in healthy human volunteers and in human patients undergoing surgery, with visualization of post-surgical changes in unprocessed single B-scans. Real-time, unprocessed MIOCT video imaging was successfully obtained in cadaveric porcine eyes during brushing of the retina with the Tano scraper, peeling of superficial retinal tissue with intraocular forceps, and separation of the posterior hyaloid face. Real-time inverted imaging enabled imaging without complex conjugate artifacts. CONCLUSIONS: MIOCT is capable of unprocessed imaging of the macula in human patients undergoing surgery and of unprocessed, real-time, video imaging of surgical maneuvers in model eyes. These capabilities represent an important step towards development of MIOCT for efficient, real-time imaging of manipulations during human surgery.


Assuntos
Diagnóstico por Imagem/métodos , Microscopia/instrumentação , Tomografia de Coerência Óptica/instrumentação , Cirurgia Vitreorretiniana , Animais , Sistemas Computacionais , Humanos , Retina/anatomia & histologia , Suínos , Gravação em Vídeo , Vitrectomia
6.
Ophthalmic Surg Lasers Imaging ; 42 Suppl: S85-94, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21790116

RESUMO

Optical coherence tomography (OCT) has transformed diagnostic ophthalmic imaging but until recently has been limited to the clinic setting. The development of spectral-domain OCT (SD-OCT), with its improved speed and resolution, along with the development of a handheld OCT scanner, enabled portable imaging of patients unable to sit in a conventional tabletop scanner. This handheld SD-OCT unit has proven useful in examinations under anesthesia and, more recently, in intraoperative imaging of preoperative and postoperative manipulations. Recently, several groups have pioneered the development of novel OCT modalities, such as microscope-mounted OCT systems. Although still immature, the development of these systems is directed toward real-time imaging of surgical maneuvers in the intraoperative setting. This article reviews intraoperative imaging of the posterior and anterior segment using the handheld SD-OCT and recent advances toward real-time microscope-mounted intrasurgical imaging.


Assuntos
Técnicas de Diagnóstico Oftalmológico/instrumentação , Monitorização Intraoperatória/instrumentação , Procedimentos Cirúrgicos Oftalmológicos , Tomografia de Coerência Óptica/instrumentação , Oftalmopatias/cirurgia , Humanos , Monitorização Intraoperatória/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA