Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eye (Lond) ; 37(14): 2915-2920, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36754984

RESUMO

INTRODUCTION: The incidence of post vitrectomy endophthalmitis (PVE) is reported to be between 0.02 and 0.84%. Resterilization of single use instruments is a common practice amidst developing countries to make it more affordable to the patients by reducing the cost of the surgery and also reduce the environmental hazard. The aim of our study is to evaluate the incidence of PVE amidst existing sterilization practices of reused instruments in multiple vitreoretinal centres in India. METHODOLOGY: Centres with an endophthalmitis tracking system were invited to participate in a survey. Twenty-five centres were sent a questionnaire via email. The questionnaire included details about the institution, number of vitrectomies performed in a year, sterilization practices followed pre-operatively, intraoperatively and postoperatively, incidence of endophthalmitis and instrument reuse policies. RESULTS: A total of 29 cases of endophthalmitis were reported out of the 47,612 vitrectomies performed across various centres. The mean incidence of endophthalmitis was 0.06%. There was no difference in the rates of endophthalmitis based on various pre-operative, intraoperative or postoperative prophylactic measures. Nearly 80% of the centres change most of the instruments after every case, while the rest reused. The mean number of times a cutter was being reused until discarded was 4.7. Nearly 76% followed a performance-based protocol, and the remaining 24% had a fixed protocol for the number of times an instrument can be reused before discarding it. CONCLUSION: PVE rates are not significantly different in India despite the multiuse of single use instruments. The purpose of this paper is not to suggest an alternate protocol but to creating one in the future with these results in mind, to rationalise the use of single use instruments, make VR surgery more affordable and also have a positive impact on the carbon footprint of consumables in surgery.


Assuntos
Endoftalmite , Infecções Oculares Bacterianas , Humanos , Vitrectomia/efeitos adversos , Vitrectomia/métodos , Complicações Pós-Operatórias/etiologia , Incidência , Infecções Oculares Bacterianas/etiologia , Estudos Retrospectivos , Endoftalmite/epidemiologia , Endoftalmite/etiologia , Endoftalmite/prevenção & controle , Índia/epidemiologia
2.
Retina ; 43(2): 338-347, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36228191

RESUMO

PURPOSE: To report outcomes of pediatric patients with combined hamartoma of the retina and the retina pigment epithelium followed up conservatively or after pars plana vitrectomy. METHODS: This retrospective multicenter study included 62 eyes of 59 pediatric patients with combined hamartoma of the retina and the retina pigment epithelium from 13 different international centers with an average age of 7.7 ± 4.7 (0.3-17) years at the time of the diagnosis and having undergone pars plana vitrectomy or followed conservatively. At baseline and each visit, visual acuity values, optical coherence tomography for features and central foveal thickness, and tumor location were noted. Lesions were called as Zone 1, if it involves the macular and peripapillary areas, and the others were called as Zone 2 lesions. RESULTS: Twenty-one eyes of 20 patients in the intervention group and 41 eyes of 39 patients in the conservative group were followed for a mean of 36.2 ± 40.4 (6-182) months. Best-corrected visual acuity improved in 11 (68.8%) of 16 eyes in the intervention group and 4 (12.9%) of 31 eyes in the conservative group ( P < 0.001). The mean central foveal thickness decreased from 602.0 ± 164.9 µ m to 451.2 ± 184.3 µ m in the intervention group, while it increased from 709.5 ± 344.2 µ m to 791.0 ± 452.1 µ m in Zone 1 eyes of the conservative group. Posterior location of tumor, irregular configuration of the foveal contour and ellipsoid Zone defect in optical coherence tomography, subretinal exudate and prominent vascular tortuosity were associated with poor visual acuity. CONCLUSION: Vitreoretinal surgery is safe and effective in improving vision and reducing retinal distortion in Zone 1 combined hamartoma of the retina and the retina pigment epithelium in children.


Assuntos
Hamartoma , Doenças Retinianas , Humanos , Criança , Pré-Escolar , Epitélio Pigmentado da Retina/patologia , Doenças Retinianas/diagnóstico , Doenças Retinianas/cirurgia , Doenças Retinianas/patologia , Retina/patologia , Tomografia de Coerência Óptica/métodos , Hamartoma/diagnóstico , Hamartoma/cirurgia , Vitrectomia/métodos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA