Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
1.
Eur Heart J Case Rep ; 8(4): ytae173, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38628857

RESUMO

Background: The aetiology of secondary complete atrioventricular blocks includes ischaemia, cardiac sarcoidosis, electrolyte imbalance, drug use, rheumatic fever, and infections such as Lyme disease and endocarditis. Diagnosis is important since some of these causes are reversible. Although several studies have reported on aortic valve calcification causing complete atrioventricular blocks, no study has described improvement of complete atrioventricular blocks by removal of the calcification. Case summary: A 42-year-old man with syncope had a Mobitz type II atrioventricular block, an alternating bundle branch block, and severe aortic stenosis. We identified a 10 s paroxysmal complete atrioventricular block with pre-syncope and performed pacemaker implantation. Electrocardiography-gated computed tomography confirmed that the calcification had reached the muscular septum. 18F-fluorodeoxyglucose-positron emission tomography (FDG-PET) revealed significant FDG uptake with high CT value of calcification in basal interventricular septum. The calcification in the septum was removed carefully, and aortic valve replacement was performed. The atrioventricular conduction capacity improved post-surgery. During the 1-year follow-up, the patient reported dramatic improvement in exercise capacity. We also noted an improvement of <0.1% in the right ventricular pacing burden. Discussion: Complete atrioventricular blocks occur in patients with aortic stenosis accompanied by severe calcification of the aortic valve, which are visualized comprehensively by echocardiography. Electrocardiography-gated computed tomography and FDG-PET enabled detailed evaluation of the extent of calcification and pre- and post-operative tissue inflammation. Hence, we suspected that the calcification in the septum was causing complete atrioventricular block. Moreover, clinicians should recognize that aortic valve calcification with aortic stenosis can cause complete atrioventricular blocks.

2.
Bioengineering (Basel) ; 11(4)2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38671826

RESUMO

This study investigated six-month outcomes of first models of ascending aortic replacement. The molds used to produce the Biotube were implanted subcutaneously in goats. After 2-3 months, the molds were explanted to obtain the Biotubes (inner diameter, 12 mm; wall thickness, 1.5 mm). Next, we performed ascending aortic replacement using the Biotube in five allogenic goats. At 6 months, the animals underwent computed tomography (CT) and histologic evaluation. As a comparison, we performed similar surgeries using glutaraldehyde-fixed autologous pericardial rolls or pig-derived heterogenous Biotubes. At 6 months, CT revealed no aneurysmalization of the Biotube or pseudoaneurysm formation. The histologic evaluation showed development of endothelial cells, smooth muscle cells, and elastic fibers along the Biotube. In the autologous pericardium group, there was no evidence of new cell development, but there was calcification. The histologic changes observed in the heterologous Biotube group were similar to those in the allogenic Biotube group. However, there was inflammatory cell infiltration in some heterologous Biotubes. Based on the above, we could successfully create the world's first Biotube-based ascending aortic replacement models. The present results indicate that the Biotube may serve as a scaffold for aortic tissue regeneration.

3.
Bioengineering (Basel) ; 11(3)2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38534477

RESUMO

Biotubes are autologous tubular tissues developed within a patient's body through in-body tissue architecture, and they demonstrate high potential for early clinical application as a vascular replacement. In this pilot study, we used large animals to perform implantation experiments in preparation for preclinical testing of Biotube. The biological response after Biotube implantation was histologically evaluated. The designed Biotubes (length: 50 cm, internal diameter: 4 mm, and wall thickness: 0.85 mm) were obtained by embedding molds on the backs of six goats for a predetermined period (1-5 months). The same goats underwent bypass surgery on the carotid arteries using Biotubes (average length: 12 cm). After implantation, echocardiography was used to periodically monitor patency and blood flow velocity. The maximum observation period was 6 months, and tissue analysis was conducted after graft removal, including the anastomosis. All molds generated Biotubes that exceeded the tensile strength of normal goat carotid arteries, and eight randomly selected Biotubes were implanted. Thrombotic occlusion occurred immediately postoperatively (1 tube) if anticoagulation was insufficient, and two tubes, with insufficient Biotube strength (<5 N), were ruptured within a week. Five tubes maintained patency for >2 months without aneurysm formation. The spots far from the anastomosis became stenosed within 3 months (3 tubes) when Biotubes had a wide intensity distribution, but the shape of the remaining two tubes remained unchanged for 6 months. The entire length of the bypass region was walled with an αSMA-positive cell layer, and an endothelial cell layer covered most of the lumen at 2 months. Complete endothelial laying of the luminal surface was obtained at 3 months after implantation, and a vascular wall structure similar to that of native blood vessels was formed, which was maintained even at 6 months. The stenosis was indicated to be caused by fibrin adhesion on the luminal surface, migration of repair macrophages, and granulation formation due to the overproliferation of αSMA-positive fibroblasts. We revealed the importance of Biotubes that are homogeneous, demonstrate a tensile strength > 5 N, and are implanted under appropriate antithrombotic conditions to achieve long-term patency of Biotube. Further, we clarified the Biotube regeneration process and the mechanism of stenosis. Finally, we obtained the necessary conditions for a confirmatory implant study planned shortly.

4.
J Vasc Surg Cases Innov Tech ; 9(4): 101345, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38054083

RESUMO

In recent years, mycotic aortic aneurysms have been increasingly treated successfully by endovascular means. The introduction of custom-made fenestrated and branched devices, parallel graft techniques, and in situ fenestration has enabled total endovascular treatment also for arch pathologies. We describe a total endovascular repair of a mycotic arch aneurysm with in situ laser fenestration using venoarterial extracorporeal membrane oxygenation to preserve flow to vital organs.

5.
Artigo em Inglês | MEDLINE | ID: mdl-37995016

RESUMO

BACKGROUND: The most common complication of thoracic aortic disease with shaggy aorta is cerebral infarction. We have performed "low-flow perfusion" as a method of extracorporeal circulation to prevent cerebral embolism in patients with strong atherosclerotic lesions in the aortic arch. METHODS: "Low-flow perfusion" is a method in which cardiopulmonary bypass is started by partial blood removal, approaching deep hypothermia while maintaining self-cardiac output. We compared the outcomes of 12 patients who underwent the "low-flow perfusion" method (Group L) with those of 12 who underwent normal extracorporeal circulation (Group N) during aortic arch surgery since 2019. RESULTS: Group L consisted of 8 males with an average age of 73 years old, and Group N consisted of 6 males with an average age of 73 years old. The average time from the start of cooling to ventricular fibrillation was 9.5 min in Group L and 3.6 min in Group N (p < 0.01). The eardrum temperature when ventricular fibrillation was reached was 28.2 °C in Group L and 32.5 °C in Group N (p = 0.01). A blood flow analysis also revealed low wall shear stress on the lesser curvature of the aortic arch. CONCLUSION: With this method, the intracranial temperature was sufficiently low at the time of ventricular fibrillation, and there was no need to increase the total pump flow. The low-flow perfusion method can prevent cerebral embolism by preventing atheroma destruction by the blood flow jet while maintaining the self-cardiac output during the cooling process.

6.
Minim Invasive Ther Allied Technol ; 32(6): 345-347, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37729442

RESUMO

A 68-year-old man with a history of valve-sparing aortic root replacement and endoscopic aortic valve replacement was admitted to our hospital with dyspnea. Transthoracic echocardiography revealed severe pulmonary valve regurgitation. The patient had undergone cardiac surgery twice, through median sternotomy and right thoracotomy; therefore, we planned endoscopic pulmonary valve replacement via the left thoracic approach. The patient was placed in a modified right lateral decubitus position and underwent mild hypothermic cardiopulmonary bypass. An on-pump beating-heart technique was used during surgery. The 3D endoscopic system and trocars for surgical instruments were inserted through the left 3rd and 4th intercostal spaces. After incision of the pulmonary artery, the pulmonary cusps were resected. A 27-mm St Jude Medical Epic heart valve was implanted in the intra-annular position. Subsequently, the left atrial appendage was resected. The patient was discharged without complications. To our knowledge, this is the first case of totally endoscopic pulmonary valve replacement.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Pulmonar , Masculino , Humanos , Idoso , Implante de Prótese de Valva Cardíaca/métodos , Valva Pulmonar/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Endoscopia , Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos
7.
Kyobu Geka ; 76(9): 685-689, 2023 Sep.
Artigo em Japonês | MEDLINE | ID: mdl-37735725

RESUMO

A 18-year-old man was driving at 100 km/h on a motorbike and collided with a utility pole. He was taken to our hospital in a state of shock due to an unstable pelvic fracture and cardiac tamponade. Pericardial drainage was carried out, but intrapericardial hemorrhage persisted and the patient underwent emergency thoracotomy and suture of right atrial injury. After hemodynamic condition improved, the patient was transferred to a tertiary care facility. For the pelvic fracture, open reduction and fixation was performed on the 6th day after injury. During recovery, moderate mitral valve regurgitation and severe tricuspid valve regurgitation due to rupture of the right ventricular papillary muscle were diagnosed. The patient's exercise tolerance was too reduced to continue rehabilitation. Thirty-seven days after the injury, mitral and tricuspid valve repair was performed. Four months after the injury, he was discharged without sequelae.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Fraturas Ósseas , Masculino , Humanos , Adolescente , Músculos Papilares/cirurgia , Átrios do Coração/cirurgia , Ventrículos do Coração/cirurgia
8.
Surg Case Rep ; 9(1): 138, 2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37530898

RESUMO

BACKGROUND: Segmental absence of intestinal musculature (SAIM) is a partial defect of the intrinsic muscular layer of the intestinal tract. In this report, we describe a case of perforation of the sigmoid colon due to SAIM accompanied by vascular Ehlers-Danlos syndrome (vEDS), which was successfully treated by surgical therapy. CASE PRESENTATION: A male in his 30 s was being followed up for vEDS diagnosed by genetic testing. He had undergone two major vascular surgeries, abdominal aortic artery revascularization and thoracic endovascular aortic repair for a residual dissection and enlarging abdominal aortic aneurysm. On postoperative day 11, the patient developed perforation of the sigmoid colon for which intraperitoneal lavage and drainage, Hartmann surgery, and transverse colostomy were performed. Histological findings showed no disturbance of blood flow or diverticulum but did show a defect in the intrinsic muscular layer around the perforation site, leading to the pathological diagnosis of SAIM and associated perforation of the sigmoid colon. Postoperatively, the patient had no complications and was discharged on postoperative day 18. The patient is being followed as an outpatient and has experienced no relapse. CONCLUSIONS: Both SAIM and vEDS, which may be related diseases, are associated with the presence of tissue fragility and have a high potential to cause intestinal perforation Caution should be exercised during surveillance in patients with constipation and examinations that cause increased intestinal pressure.

9.
Vasc Endovascular Surg ; 57(8): 937-940, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37306014

RESUMO

Endovascular stent-graft therapy is a commonly performed procedure for aortic lesions worldwide and complications unique to stent grafts, such as postoperative endoleaks, are well known. However, as this treatment modality becomes more popular, physicians should carefully monitor for other unexpected complications, which may not always be related to the graft. This study presents a case of leiomyosarcoma of the aorta that developed during follow-up for a type II endoleak (T2EL) after thoracic endovascular aortic repair. The presence of the T2EL hindered the diagnosis of the sarcoma at an early stage. These findings suggest that an apparent aneurysm that grows suddenly during follow-up after stent grafting should raise the index of suspicion for a neoplasm as well as an endoleak.


Assuntos
Endoleak , Correção Endovascular de Aneurisma , Leiomiossarcoma , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Correção Endovascular de Aneurisma/efeitos adversos , Leiomiossarcoma/diagnóstico por imagem , Leiomiossarcoma/cirurgia , Leiomiossarcoma/complicações , Complicações Pós-Operatórias , Estudos Retrospectivos , Stents/efeitos adversos , Resultado do Tratamento
10.
Kyobu Geka ; 76(6): 463-467, 2023 Jun.
Artigo em Japonês | MEDLINE | ID: mdl-37258026

RESUMO

A 60-year-old woman was admitted to our institution for exertional dyspnea. Transthoracic echocardiography revealed a 1.6 cm secundum atrial septal defect( ASD) and a 4.2×3.1 cm mobile left atrial mass originating from the ASD. The tumor migrated to the mitral valve during diastole and to the atrial septal defect during systole. A totally endoscopic approach via a small right thoracotomy was adopted to resect the mass and close the ASD with a Hemashield patch. Histopathologic examination of the excised mass was consistent with myxoma. The postoperative course was uneventful. A 2-year follow-up revealed no recurrence of the myxoma and ASD.


Assuntos
Fibrilação Atrial , Neoplasias Cardíacas , Comunicação Interatrial , Mixoma , Feminino , Humanos , Pessoa de Meia-Idade , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Neoplasias Cardíacas/diagnóstico por imagem , Neoplasias Cardíacas/cirurgia , Ecocardiografia , Mixoma/diagnóstico por imagem , Mixoma/cirurgia
11.
J Cardiothorac Surg ; 17(1): 305, 2022 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-36510240

RESUMO

BACKGROUND: Descending aortic replacement often involves making large incisions; thus, it results in massive invasions. We report the case of a patient with dilated descending aorta treated using endoscopic-assisted descending aortic replacement with essentially minimal invasions. CASE PRESENTATION: We performed endoscopic-assisted descending aortic replacement with a single incision involving six wounds by trocar puncturing on a 59-year-old man who was diagnosed with dilated descending aorta by stent graft-induced new entry. Subsequently, the patient was discharged on postoperative day 11 without any complications. CONCLUSIONS: Despite minor incisions, our approach can be indicated to almost the same group of patients in whom the conventional approach can be performed. Our procedure involved a single incision of only 8 cm and six wounds by trocar puncturing. Thus, endoscopic-assisted surgery can be a useful option in descending aortic surgery.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Masculino , Humanos , Pessoa de Meia-Idade , Stents , Aorta/cirurgia , Endoscopia , Reimplante , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos
12.
J Biomed Mater Res B Appl Biomater ; 110(11): 2387-2398, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35561095

RESUMO

There are no small-diameter, long artificial vascular grafts for below-knee bypass surgery in chronic limb-threatening ischemia. We have developed tissue-engineered vascular grafts called "Biotubes®" using a completely autologous approach called in-body tissue architecture (iBTA). This study aimed at pre-implantation evaluation of Biotube and its in vivo preparation device, Biotube Maker, for use in below-knee bypass surgery. Forty nine makers were subcutaneously embedded into 17 goats for predetermined periods (1, 2, or 3 months). All makers produced Biotubes as designed without inflammation over all periods, with the exception of a few cases with minor defects (success rate: 94%). Small hole formation occurred in only a few cases. All Biotubes obtained had an inner diameter of 4 mm and a length of 51 to 52 cm with a wall thickness of 594 ± 97 µm. All Biotubes did not kink when completely bent under an internal pressure of 100 mmHg and did not leak without any deformation under a water pressure of 200 mmHg. Their burst strength was 2409 ± 473 mmHg, and suture retention strength was 1.75 ± 0.27 N, regardless of the embedding period, whereas tensile strength increased from 7.5 ± 1.3 N at 1 month to 9.7 ± 2.0 N at 3 months with the embedding period. The amount of water leakage from the needle holes prepared in the Biotube wall was approximately 1/7th of that in expanded polytetrafluoroethylene vascular grafts. The Biotubes could be easily connected to each other without cutting or anastomosis leaks. They could be stored for at least 1 year at room temperature. This study confirmed that even Biotubes formed 1 month after embedding of Biotube Makers had properties comparable to arteries.


Assuntos
Implante de Prótese Vascular , Cabras , Animais , Prótese Vascular , Politetrafluoretileno , Engenharia Tecidual , Água
13.
J Thorac Cardiovasc Surg ; 163(5): 1739-1750.e4, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35241276

RESUMO

OBJECTIVE: The study objective was to evaluate the safety and effectiveness of the second-generation, low-profile RelayPro (Terumo Aortic) thoracic endograft for the treatment of descending thoracic aortic aneurysm or penetrating atherosclerotic ulcer. METHOD: A prospective, international, nonblinded, nonrandomized, pivotal trial analyzed a primary safety end point of major adverse events at 30 days (death, myocardial infarction, stroke, renal/respiratory failure, paralysis, bowel ischemia, procedural blood loss) and a primary effectiveness end point of treatment success at 1 year (technical success, patency, absence of aneurysm rupture, type I/III endoleaks, stent fractures, reinterventions, aneurysm expansion, and migration) compared with performance goals from the previous generation Relay pivotal study. The study was conducted in 36 centers in the United States and Japan and enrolled participants between 2017 and 2019. RESULTS: The study population of 110 patients had a median (interquartile range) age of 76 (70-81) years, 69 (62.7%) were male, and 43 (39.1%) were Asian. Patients were treated for 76 fusiform aneurysms (69%), 24 saccular aneurysms (22%), and 10 penetrating atherosclerotic ulcers (9%). Most patients (82.7%) were treated with a non-bare stent configuration. Technical success was 100%. The median (interquartile range) procedure time was 91 (64-131) minutes, and the deployment time was 16 (10-25) minutes. A total of 50 patients (73.5%) in the US cohort had percutaneous access, whereas centers in Japan used only surgical cutdown. The 30-day composite major adverse events rate was 6.4% (95% upper confidence interval, 11.6%; P = .0002): 2 strokes, 2 procedural blood losses greater than 1000 mL requiring transfusion, 2 paralysis events, and 1 renal failure. Primary effectiveness was 89.2% (lower 95% confidence interval, 81.8%; P = .0185). Nine subjects experienced 11 events (1 aneurysm expansion, 6 secondary interventions, and 4 type I endoleaks). There was no loss of stent-graft patency, no rupture, no fractures, and no migration. CONCLUSIONS: The low-profile RelayPro thoracic endograft met the study primary end points and demonstrated satisfactory 30-day safety and 1-year effectiveness for the treatment of patients with aneurysms of the descending thoracic aorta or penetrating atherosclerotic ulcers. Follow-up is ongoing to evaluate longer-term outcomes and durability.


Assuntos
Aneurisma da Aorta Torácica , Aterosclerose , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/cirurgia , Aterosclerose/etiologia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Paralisia/etiologia , Paralisia/cirurgia , Estudos Prospectivos , Desenho de Prótese , Stents , Resultado do Tratamento , Úlcera/diagnóstico por imagem , Úlcera/cirurgia , Estados Unidos
14.
Ann Vasc Surg ; 78: 152-160, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34464725

RESUMO

BACKGROUND: Hybrid endovascular repair for thoracoabdominal aortic aneurysm (TAAA) is a less invasive alternative treatment than conventional open repair. However, disseminated intravascular coagulation (DIC) and hemorrhagic complications can occur postoperatively. We investigated risk factors for hemorrhagic complications after hybrid endovascular TAAA repair. METHODS: Sixty-one patients who underwent elective hybrid endovascular TAAA repair between 2007 and 2020 were included. Laboratory data before and after placing stent graft were collected, and DIC was diagnosed using a scoring system established by the Japanese Association for Acute Medicine. The length of the stent graft used to cover the aorta was defined as the aortic coverage length, which was measured using the first postoperative computed tomography image. Predictors of unexpected hemorrhagic complications were evaluated. RESULTS: Postoperative thrombocytopenia was observed in 57 (93%) patients, and their platelet count decreased significantly after stent graft placement (14.3 [9.5-18.0] vs. 8.2 [5.4-10.9] × 104/µL, P < 0.001). Fifteen (25%) and 45 patients (74%) were diagnosed with DIC before and after stent graft placement, respectively. Hemorrhagic complications were observed in 21 patients (34%). Multivariate logistic regression analysis revealed that aortic coverage length was an independent risk factor for hemorrhagic complications (odds ratio 1.441/50 mm increase; 95% confidence interval, 1.041-1.994, P = 0.027). The cutoff value for aortic coverage length obtained from the receiver operating characteristic curve (area under the curve = 0.72) was 304.4 mm (sensitivity 0.76, specificity 0.70). CONCLUSION: Aortic coverage length is a risk factor for hemorrhagic complications. Patients undergoing extensive aortic coverage greater than 304 mm should be closely monitored.


Assuntos
Implante de Prótese Vascular/efeitos adversos , Prótese Vascular , Coagulação Intravascular Disseminada/etiologia , Procedimentos Endovasculares/efeitos adversos , Hemorragia Pós-Operatória/etiologia , Idoso , Aneurisma da Aorta Torácica , Procedimentos Cirúrgicos Eletivos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Stents , Trombocitopenia/etiologia
15.
Gen Thorac Cardiovasc Surg ; 70(3): 230-238, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34386904

RESUMO

OBJECTIVES: This study aimed to investigate which factors have a great impact on coagulopathy after cardiopulmonary bypass (CPB) using rotational thromboelastometry (ROTEM). METHODS: Ninety-eight patients undergoing cardiovascular surgery using CPB were enrolled. Data of amplitude 10 min after clotting time (A10) of ROTEM measured routinely before and after CPB were retrospectively collected. ROTEM has some assays by which we can evaluate the capacity of extrinsic coagulation (EXTEM), intrinsic coagulation (INTEM), fibrin polymerization (FIBTEM), and the effect of heparin (HEPTEM). The platelet component, defined as PLTEM, can be calculated by subtracting FIBTEM from EXTEM. Age, sex, total plasma volume, pre-CPB A10, lowest body temperature, in-out balance during CPB, intraoperative bleeding amount, and type of pumps were considered as possible factors. Univariate and multivariate analyses were performed for the rate of change of A10. RESULTS: The change rate of each A10 had a significant negative correlation with bleeding amount (p < 0.01 for EXTEM, p < 0.01 for INTEM, p = 0.02 for FIBTEM, p < 0.01 for PLTEM). Female sex was a significant contributive predictor for the greater decline of EXTEM (p < 0.01) and INTEM (p < 0.01), positive balance for EXTEM (p < 0.01), FIBTEM (p = 0.01), and PLTEM (p < 0.01), long CPB time for INTEM (p = 0.01), centrifugal pump for FIBTEM (p < 0.01), and large pre-CPB A10 for PLTEM (p < 0.01). CONCLUSION: In perioperative hemostatic management using ROTEM, attention should be given to the effects of these multiple factors.


Assuntos
Transtornos da Coagulação Sanguínea , Hemostáticos , Transtornos da Coagulação Sanguínea/diagnóstico , Transtornos da Coagulação Sanguínea/etiologia , Ponte Cardiopulmonar/efeitos adversos , Feminino , Humanos , Estudos Retrospectivos , Tromboelastografia
16.
J Thorac Cardiovasc Surg ; 164(6): 1681-1692.e2, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-33965229

RESUMO

OBJECTIVE: We performed a multicenter prospective comparative study to determine the impact of a Japanese frozen elephant trunk device on total arch replacement compared with conventional repair without it. METHODS: Between 2016 and 2019, a total of 684 patients (frozen elephant trunk procedure; n = 369; conventional repair, n = 315) from 41 institutions were enrolled. The 2 procedures were selected according to each center's strategy. RESULTS: The frozen elephant trunk procedure was applied more for aortic dissection, whereas the conventional repairs were predominantly performed for aneurysms. In the former, only hypothermic circulatory arrest time was reduced among the intraoperative parameters. Although there were no differences in the 30-day and in-hospital mortality rates (0.8% and 1.6%, respectively, for the frozen elephant trunk procedure vs 0.3% and 0.6%, respectively, for conventional repair), the neurologic complication rates were significantly higher in stroke (5.7% vs 2.2%; P = .022) and paraplegia (1.6% vs 0%; P = .023). In the propensity score matching analyses using 11 variables, statistical significance disappeared in the differences for mortality and neurologic morbidity (stroke and paraplegia/paraparesis) rates of 194 patients of each group, although they were still higher for the frozen elephant trunk procedure. CONCLUSIONS: The early outcomes of total arch replacement with the frozen elephant trunk procedure were acceptable despite its higher prevalence of emergency or redo surgery, which was comparable to that of the conventional repair. This procedure had higher rates of spinal cord injury than the conventional repair, which is a disadvantage of this approach.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Acidente Vascular Cerebral , Humanos , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Japão , Estudos Prospectivos , Paraplegia/etiologia , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento , Estudos Retrospectivos
17.
Heart Vessels ; 37(6): 1044-1054, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34822000

RESUMO

BACKGROUND: Paradoxical low-flow, low-gradient (PLF-LG) aortic stenosis (AS) is associated with poor prognosis in patients undergoing transcatheter aortic valve implantation (TAVI). This study aimed to verify the conventional criteria of PLF-LG AS (left ventricular ejection fraction [LVEF] > 50%, mean aortic valve pressure gradient [AVPG] < 40 mm Hg and stroke volume index [SVI] < 35 ml/m2 by measuring Doppler method) compatible for predicting prognosis in patients undergoing TAVI. MATERIALS AND METHODS: A total of 128 consecutive patients who underwent TAVI for AS with LVEF > 50% were enrolled. The primary endpoint was the hospital readmission due to heart failure (HRHF) and the secondary endpoint was all-cause mortality after hospital discharge. The patients were classified by both the conventional criteria of PLF-LG AS and the proposal criteria of PLF-LG AS if mean aortic valve pressure gradient (AVPG) < 40 mmHg and SVI by measuring Simpson's method < cut off value based on the ROC curve for predicting HRHF. RESULTS: According to the conventional criteria, only 6 patients were diagnosed with PLF-LG AS. However, according to the proposal criteria, 16 patients were diagnosed with PLF-LG AS. Fourteen patients developed HRHF during the follow-up period after TAVI. Based on the ROC curves, SVI by measuring Simpson's method (cut off value = 25 ml/m2) had higher sensitivity and specificity for predicting HRHF (AUC = 0.74, p = 0.0013) than SVI by measuring Doppler method (AUC = 0.63, p = 0.045). The multivariate analysis revealed that PLF-LG AS defined by the proposal criteria (HR: 5.25; 95% CI: 1.60-17.16; p = 0.0073) but not by the conventional criteria was independently associated with HRHF. PLF-LG AS defined by the conventional criteria and the proposal criteria were not associated with all-cause mortality in the univariate analysis. CONCLUSIONS: Our results demonstrated that new criteria of PLF-LG AS defined as SVI < 25 ml/m2 measured by Simpson's method could predict HRHF in patients with severe AS who underwent TAVI.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Humanos , Análise Multivariada , Readmissão do Paciente , Prognóstico , Estudos Retrospectivos , Índice de Gravidade de Doença , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Função Ventricular Esquerda
18.
Heart Rhythm O2 ; 2(4): 311-323, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34430935

RESUMO

BACKGROUND: Fibrotic remodeling of epicardial adipose tissue (EAT) is crucial for proinflammatory atrial myocardial fibrosis, which leads to atrial fibrillation (AF). OBJECTIVES: We tested the hypothesis that the ratio of central to marginal adipocyte diameter in EAT represents its fibrotic remodeling. Based on a similar concept, we also tested whether the percent (%) change in EAT fat attenuation determined using computed tomographic (CT) images can detect this remodeling. METHODS: Left atrial appendages were obtained from 76 consecutive AF patients during cardiovascular surgery. EAT in the central area (central EAT: C-EAT) and that adjacent to the atrial myocardium (Marginal EAT: M-EAT) were evaluated histologically. CT images for all of the 76 patients were also analyzed. RESULTS: The adipocyte diameter was smaller, fibrotic remodeling of EAT (EAT fibrosis) was more severe, and infiltration of macrophages and myofibroblasts was more extensive in M-EAT than in C-EAT. EAT fibrosis was positively correlated with adipocyte diameter in C-EAT and negatively correlated in M-EAT, resulting in a positive correlation between EAT fibrosis and the ratio of central to marginal adipocyte diameter (C/M diameter ratio; r = 0.73, P < .01). The C/M diameter ratio was greater in patients with persistent AF than in those with paroxysmal AF. CT images demonstrated that the %change in EAT fat attenuation was positively correlated with EAT fibrosis. CONCLUSION: Our results suggest that the central-to-marginal adipocyte diameter ratio is tightly associated with fibrotic remodeling of EAT. In addition, the %change in EAT fat attenuation determined using CT imaging can detect remodeling noninvasively.

19.
Surg Case Rep ; 7(1): 144, 2021 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-34131826

RESUMO

BACKGROUND: We describe herein an extremely rare case of intracardiac ectopic thymoma-only two pure cases have been reported to date-associated with myasthenia gravis, an infrequent complication of ectopic thymoma. CASE PRESENTATION: A 71-year-old woman with superior vena cava syndrome was found to have a large mass mainly located in the right atrium. Tumor resection under cardiopulmonary bypass was performed. The pathological diagnosis was type AB ectopic thymoma. The postoperative course was complicated by progressive respiratory failure, and she was diagnosed with myasthenic crisis based on clinical signs and the edrophonium test. The patient recovered and was weaned from prolonged mechanical ventilation after receiving intravenous immunoglobulin, and was subsequently discharged uneventfully. CONCLUSIONS: This is the first report of myasthenic crisis due to intracardiac ectopic thymoma. Residual thymoma is a risk factor for the development of post-thymectomy myasthenia gravis, and long-term follow-up is required.

20.
Interact Cardiovasc Thorac Surg ; 32(6): 969-977, 2021 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-33543242

RESUMO

OBJECTIVES: Aortic valve neocuspidization has shown satisfactory clinical outcomes; however, autologous pericardium durability is a concern for young patients. This study applied an autologous collagenous membrane (Biosheet®), produced by in-body tissue architecture, to aortic valve neocuspidization and investigated its long-term outcome in a goat model. METHODS: Moulds were embedded subcutaneously in 6 goats. After 2 months, Biosheets formed in the moulds. We performed aortic valve neocuspidization using a portion of the sheets with a thickness of 0.20-0.35 mm, measured by optical coherence tomography. Animals were subjected to echocardiography and histological evaluation at 6 months (n = 3) and 12 months (n = 3). As a control, the glutaraldehyde-treated autologous pericardium was used in 4 goats that were similarly evaluated at 12 months. RESULTS: All animals survived the scheduled period. At 6 months, Biosheets maintained valve function and showed a regeneration response: fusion to the annulus, cell infiltration to the leaflets and appearance of elastic fibres at the ventricular side. After 12 months, the regenerative structure had changed little without regression, and there was negligible calcification in the 1/9 leaflets. However, all cases had one leaflet tear, resulting in moderate-to-severe aortic regurgitation. In the pericardium group, three-fourths of the animals experienced moderate-to-severe aortic regurgitation with a high rate of calcification (9/12 leaflets). CONCLUSIONS: Biosheets may have regeneration potential and anti-calcification properties in contrast to autologous pericardium. However, in order to obtain reliable outcome, further improvements are required to strictly control and optimize its thickness, density and homogeneity.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Valva Aórtica , Animais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Cabras , Pericárdio/transplante , Transplante Autólogo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA