Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
EJNMMI Res ; 13(1): 35, 2023 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-37103671

RESUMO

BACKGROUND: Early intrahepatic recurrence is common after surgical resection of hepatocellular carcinoma (HCC) and leads to increased morbidity and mortality. Insensitive and nonspecific diagnostic imaging contributes to EIR and results in missed treatment opportunities. In addition, novel modalities are needed to identify targets amenable for targeted molecular therapy. In this study, we evaluated a zirconium-89 radiolabeled glypican-3 (GPC3) targeting antibody conjugate (89Zr-αGPC3) for use in positron emission tomography (PET) for detection of small, GPC3+ HCC in an orthotopic murine model. Athymic nu/J mice received hepG2, a GPC3+ human HCC cell line, into the hepatic subcapsular space. Tumor-bearing mice were imaged by PET/computerized tomography (CT) 4 days after tail vein injection of 89Zr-αGPC3. Livers were then excised for the tumors to be identified, measured, bisected, and then serially sectioned at 500 µm increments. Sensitivity and specificity of PET/CT for 89Zr-αGPC3-avid tumors were assessed using tumor confirmation on histologic sections as the gold standard. RESULTS: In tumor-bearing mice, 89Zr-αGPC3 avidly accumulated in the tumor within four hours of injection with ongoing accumulation over time. There was minimal off-target deposition and rapid bloodstream clearance. Thirty-eight of 43 animals had an identifiable tumor on histologic analysis. 89Zr-αGPC3 immuno-PET detected all 38 histologically confirmed tumors with a sensitivity of 100%, with the smallest tumor detected measuring 330 µm in diameter. Tumor-to-liver ratios of 89Zr-αGPC3 uptake were high, creating excellent spatial resolution for ease of tumor detection on PET/CT. Two of five tumors that were observed on PET/CT were not identified on histologic analysis, yielding a specificity of 60%. CONCLUSIONS: 89Zr-αGPC3 avidly accumulated in GPC3+ tumors with minimal off-target sequestration. 89Zr-αGPC3 immuno-PET yielded a sensitivity of 100% and detected sub-millimeter tumors. This technology may improve diagnostic sensitivity of small HCC and select GPC3+ tumors for targeted therapy. Human trials are warranted to assess its impact.

2.
Discov Oncol ; 13(1): 85, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36048266

RESUMO

BACKGROUND: Patients undergoing chemoradiation and immune checkpoint inhibitor (ICI) therapy for locally advanced non-small cell lung cancer (NSCLC) experience pulmonary toxicity at higher rates than historical reports. Identifying biomarkers beyond conventional clinical factors and radiation dosimetry is especially relevant in the modern cancer immunotherapy era. We investigated the role of novel functional lung radiomics, relative to functional lung dosimetry and clinical characteristics, for pneumonitis risk stratification in locally advanced NSCLC. METHODS: Patients with locally advanced NSCLC were prospectively enrolled on the FLARE-RT trial (NCT02773238). All received concurrent chemoradiation using functional lung avoidance planning, while approximately half received consolidation durvalumab ICI. Within tumour-subtracted lung regions, 110 radiomics features (size, shape, intensity, texture) were extracted on pre-treatment [99mTc]MAA SPECT/CT perfusion images using fixed-bin-width discretization. The performance of functional lung radiomics for pneumonitis (CTCAE v4 grade 2 or higher) risk stratification was benchmarked against previously reported lung dosimetric parameters and clinical risk factors. Multivariate least absolute shrinkage and selection operator Cox models of time-varying pneumonitis risk were constructed, and prediction performance was evaluated using optimism-adjusted concordance index (c-index) with 95% confidence interval reporting throughout. RESULTS: Thirty-nine patients were included in the study and pneumonitis occurred in 16/39 (41%) patients. Among clinical characteristics and anatomic/functional lung dosimetry variables, only the presence of baseline chronic obstructive pulmonary disease (COPD) was significantly associated with the development of pneumonitis (HR 4.59 [1.69-12.49]) and served as the primary prediction benchmark model (c-index 0.69 [0.59-0.80]). Discrimination of time-varying pneumonitis risk was numerically higher when combining COPD with perfused lung radiomics size (c-index 0.77 [0.65-0.88]) or shape feature classes (c-index 0.79 [0.66-0.91]) but did not reach statistical significance compared to benchmark models (p > 0.26). COPD was associated with perfused lung radiomics size features, including patients with larger lung volumes (AUC 0.75 [0.59-0.91]). Perfused lung radiomic texture features were correlated with lung volume (adj R2 = 0.84-1.00), representing surrogates rather than independent predictors of pneumonitis risk. CONCLUSIONS: In patients undergoing chemoradiation with functional lung avoidance therapy and optional consolidative immune checkpoint inhibitor therapy for locally advanced NSCLC, the strongest predictor of pneumonitis was the presence of baseline chronic obstructive pulmonary disease. Results from this novel functional lung radiomics exploratory study can inform future validation studies to refine pneumonitis risk models following combinations of radiation and immunotherapy. Our results support functional lung radiomics as surrogates of COPD for non-invasive monitoring during and after treatment. Further study of clinical, dosimetric, and radiomic feature combinations for radiation and immune-mediated pneumonitis risk stratification in a larger patient population is warranted.

3.
Adv Radiat Oncol ; 7(2): 100857, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35387421

RESUMO

Purpose: We sought to examine the prognostic value of fluorodeoxyglucose-positron emission tomography (PET) imaging during chemoradiation for unresectable non-small cell lung cancer for survival and hypothesized that tumor PET response is correlated with peripheral T-cell function. Methods and Materials: Forty-five patients with American Joint Committee on Cancer version 7 stage IIB-IIIB non-small cell lung cancer enrolled in a phase II trial and received platinum-doublet chemotherapy concurrent with 6 weeks of radiation (NCT02773238). Fluorodeoxyglucose-PET was performed before treatment start and after 24 Gy of radiation (week 3). PET response status was prospectively defined by multifactorial radiologic interpretation. PET responders received 60 Gy in 30 fractions, while nonresponders received concomitant boosts to 74 Gy in 30 fractions. Peripheral blood was drawn synchronously with PET imaging, from which germline DNA sequencing, T-cell receptor sequencing, and plasma cytokine analysis were performed. Results: Median follow-up was 18.8 months, 1-year overall survival (OS) 82%, 1-year progression-free survival 53%, and 1-year locoregional control 88%. Higher midtreatment PET total lesion glycolysis was detrimental to OS (1 year 87% vs 63%, P < .001), progression-free survival (1 year 60% vs 26%, P = .044), and locoregional control (1 year 94% vs 65%, P = .012), even after adjustment for clinical/treatment factors. Twenty-nine of 45 patients (64%) were classified as PET responders based on a priori definition. Higher tumor programmed death-ligand 1 expression was correlated with response on PET (P = .017). Higher T-cell receptor richness and clone distribution slope were associated with improved OS (P = .018-0.035); clone distribution slope was correlated with PET response (P = .031). Conclusions: Midchemoradiation PET imaging is prognostic for survival; PET response may be linked to tumor and peripheral T-cell biomarkers.

4.
Clin Nucl Med ; 46(11): 861-871, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34172602

RESUMO

PURPOSE OF THE REPORT: We evaluated the reliability of 18F-FDG PET imaging biomarkers to classify early response status across observers, scanners, and reconstruction algorithms in support of biologically adaptive radiation therapy for locally advanced non-small cell lung cancer. PATIENTS AND METHODS: Thirty-one patients with unresectable locally advanced non-small cell lung cancer were prospectively enrolled on a phase 2 trial (NCT02773238) and underwent 18F-FDG PET on GE Discovery STE (DSTE) or GE Discovery MI (DMI) PET/CT systems at baseline and during the third week external beam radiation therapy regimens. All PET scans were reconstructed using OSEM; GE-DMI scans were also reconstructed with BSREM-TOF (block sequential regularized expectation maximization reconstruction algorithm incorporating time of flight). Primary tumors were contoured by 3 observers using semiautomatic gradient-based segmentation. SUVmax, SUVmean, SUVpeak, MTV (metabolic tumor volume), and total lesion glycolysis were correlated with midtherapy multidisciplinary clinical response assessment. Dice similarity of contours and response classification areas under the curve were evaluated across observers, scanners, and reconstruction algorithms. LASSO logistic regression models were trained on DSTE PET patient data and independently tested on DMI PET patient data. RESULTS: Interobserver variability of PET contours was low for both OSEM and BSREM-TOF reconstructions; intraobserver variability between reconstructions was slightly higher. ΔSUVpeak was the most robust response predictor across observers and image reconstructions. LASSO models consistently selected ΔSUVpeak and ΔMTV as response predictors. Response classification models achieved high cross-validated performance on the DSTE cohort and more variable testing performance on the DMI cohort. CONCLUSIONS: The variability FDG PET lesion contours and imaging biomarkers was relatively low across observers, scanners, and reconstructions. Objective midtreatment PET response assessment may lead to improved precision of biologically adaptive radiation therapy.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Biomarcadores , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/terapia , Quimiorradioterapia , Fluordesoxiglucose F18 , Humanos , Processamento de Imagem Assistida por Computador , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/terapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes
5.
Sci Rep ; 11(1): 3731, 2021 02 12.
Artigo em Inglês | MEDLINE | ID: mdl-33580090

RESUMO

Glypican-3 (GPC3) is a tumor associated antigen expressed by hepatocellular carcinoma (HCC) cells. This preclinical study evaluated the efficacy of a theranostic platform using a GPC3-targeting antibody αGPC3 conjugated to zirconium-89 (89Zr) and yttrium-90 (90Y) to identify, treat, and assess treatment response in a murine model of HCC. A murine orthotopic xenograft model of HCC was generated. Animals were injected with 89Zr-labeled αGPC3 and imaged with a small-animal positron emission/computerized tomography (PET/CT) imaging system (immuno-PET) before and 30 days after radioimmunotherapy (RIT) with 90Y-labeled αGPC3. Serum alpha fetoprotein (AFP), a marker of tumor burden, was measured. Gross tumor volume (GTV) and SUVmax by immuno-PET was measured using fixed intensity threshold and manual segmentation methods. Immuno-PET GTV measurements reliably quantified tumor burden prior to RIT, strongly correlating with serum AFP (R2 = 0.90). Serum AFP was significantly lower 30 days after RIT in 90Y-αGPC3 treated animals compared to those untreated (p = 0.01) or treated with non-radiolabeled αGPC3 (p = 0.02). Immuno-PET GTV measurements strongly correlated with tumor burden after RIT (R2 = 0.87), and GTV of animals treated with 90Y-αGPC3 was lower than in animals who did not receive treatment or were treated with non-radiolabeled αGPC3, although this only trended toward statistical significance. A theranostic platform utilizing GPC3 targeted 89Zr and 90Y effectively imaged, treated, and assessed response after radioimmunotherapy in a GPC3-expressing HCC xenograft model.


Assuntos
Carcinoma Hepatocelular/terapia , Sistemas de Liberação de Medicamentos/métodos , Glipicanas/imunologia , Animais , Carcinoma Hepatocelular/metabolismo , Carcinoma Hepatocelular/patologia , Linhagem Celular Tumoral , Glipicanas/metabolismo , Humanos , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/terapia , Camundongos , Camundongos Nus , Tomografia por Emissão de Pósitrons/métodos , Medicina de Precisão/métodos , Radioimunoterapia , Radioisótopos/farmacologia , Compostos Radiofarmacêuticos , Distribuição Tecidual , Ensaios Antitumorais Modelo de Xenoenxerto , Radioisótopos de Ítrio/farmacologia , Zircônio/farmacologia
6.
Phys Med Biol ; 65(20): 205007, 2020 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-33027064

RESUMO

We investigated the sensitivity of regional tumor response prediction to variability in voxel clustering techniques, imaging features, and machine learning algorithms in 25 patients with locally advanced non-small cell lung cancer (LA-NSCLC) enrolled on the FLARE-RT clinical trial. Metabolic tumor volumes (MTV) from pre-chemoradiation (PETpre) and mid-chemoradiation fluorodeoxyglucose-positron emission tomography (FDG PET) images (PETmid) were subdivided into K-means or hierarchical voxel clusters by standardized uptake values (SUV) and 3D-positions. MTV cluster separability was evaluated by CH index, and morphologic changes were captured by Dice similarity and centroid Euclidean distance. PETpre conventional features included SUVmean, MTV/MTV cluster size, and mean radiation dose. PETpre radiomics consisted of 41 intensity histogram and 3D texture features (PET Oncology Radiomics Test Suite) extracted from MTV or MTV clusters. Machine learning models (multiple linear regression, support vector regression, logistic regression, support vector machines) of conventional features or radiomic features were constructed to predict PETmid response. Leave-one-out-cross-validated root-mean-squared-error (RMSE) for continuous response regression (ΔSUVmean) and area-under-receiver-operating-characteristic-curve (AUC) for binary response classification were calculated. K-means MTV 2-clusters (MTVhi, MTVlo) achieved maximum CH index separability (Friedman p < 0.001). Between PETpre and PETmid, MTV cluster pairs overlapped (Dice 0.70-0.87) and migrated 0.6-1.1 cm. PETmid ΔSUVmean response prediction was superior in MTV and MTVlo (RMSE = 0.17-0.21) compared to MTVhi (RMSE = 0.42-0.52, Friedman p < 0.001). PETmid ΔSUVmean response class prediction performance trended higher in MTVlo (AUC = 0.83-0.88) compared to MTVhi (AUC = 0.44-0.58, Friedman p = 0.052). Models were more sensitive to MTV/MTV cluster regions (Friedman p = 0.026) than feature sets/algorithms (Wilcoxon signed-rank p = 0.36). Top-ranked radiomic features included GLZSM-LZHGE (large-zone-high-SUV), GTSDM-CP (cluster-prominence), GTSDM-CS (cluster-shade) and NGTDM-CNT (contrast). Top-ranked features were consistent between MTVhi and MTVlo cluster pairs but varied between MTVhi-MTVlo clusters, reflecting distinct regional radiomic phenotypes. Variability in tumor voxel cluster response prediction can inform robust radiomic target definition for risk-adaptive chemoradiation in patients with LA-NSCLC. FLARE-RT trial: NCT02773238.


Assuntos
Quimiorradioterapia , Fluordesoxiglucose F18 , Processamento de Imagem Assistida por Computador , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/terapia , Tomografia por Emissão de Pósitrons , Adulto , Idoso , Algoritmos , Carcinoma Pulmonar de Células não Pequenas/patologia , Feminino , Humanos , Estudos Longitudinais , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Curva ROC , Radiometria , Resultado do Tratamento , Carga Tumoral
7.
Phys Med Biol ; 65(24)2020 12 10.
Artigo em Inglês | MEDLINE | ID: mdl-32357344

RESUMO

Small animal research is an essential tool in studying both pharmaceutical biodistribution and disease progression over time. Furthermore, through the rapid development ofin vivoimaging technology over the last few decades, small animal imaging (also referred to as preclinical imaging) has become a mainstay for all fields of biologic research and a center point for most preclinical cancer research. Preclinical imaging modalities include optical, MRI and MRS, microCT, small animal PET, ultrasound, and photoacoustic, each with their individual strengths. The strong points of small animal PET are its translatability to the clinic; its quantitative imaging capabilities; its whole-body imaging ability to dynamically trace functional/biochemical processes; its ability to provide useful images with only nano- to pico- molar concentrations of administered compounds; and its ability to study animals serially over time. This review paper gives an overview of the development and evolution of small animal PET imaging. It provides an overview of detector designs; system configurations; multimodality PET imaging systems; image reconstruction and analysis tools; and an overview of research and commercially available small animal PET systems. It concludes with a look toward developing technologies/methodologies that will further enhance the impact of small animal PET imaging on medical research in the future.


Assuntos
Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Animais , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia por Emissão de Pósitrons/veterinária , Distribuição Tecidual
8.
Clin Cancer Res ; 25(23): 6932-6938, 2019 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-31481510

RESUMO

PURPOSE: External-beam radiation is the single most effective therapy for localized lymphoma. However, toxicity limits its use for multifocal disease. We evaluated CD45 as a therapeutic target for an antibody-radionuclide conjugate (ARC) for the treatment of lymphoma based on its ubiquitous expression, infrequent antigen loss or blockade, and the ability to target minimal disease based on panhematopoietic expression. PATIENTS AND METHODS: We performed a phase I trial of escalating doses of single-agent CD45-targeted ARC based on per-patient dosimetry using the BC8 antibody labeled with iodine-131 (131I) followed by autologous stem cell support in adults with relapsed, refractory, or high-risk B-cell non-Hodgkin lymphoma (B-NHL), T-cell NHL (T-NHL), or Hodgkin lymphoma. The primary objective was to estimate the maximum tolerated radiation absorbed dose. RESULTS: Sixteen patients were enrolled: 7 patients had B-NHL, 6 had Hodgkin lymphoma, and 3 had T-NHL. Median number of prior therapies was three (range: 2-12). Absorbed doses up to 32 Gy to liver were delivered. No dose-limiting toxicities occurred. Nonhematologic toxicity was infrequent and manageable. Objective responses were seen across histologies. Fourteen patients had measurable disease at enrollment, 57% of whom achieved complete remission (CR), including all 3 with T-NHL. Three patients with B-NHL treated among the highest dose levels (26-32 Gy) remain in CR without subsequent therapy 35-41 months later. CONCLUSIONS: CD45-targeted ARC therapy is well-tolerated at doses up to at least 32 Gy to the liver. Objective responses and long-term remissions were observed in patients with relapsed/refractory lymphoma. These data validate continued evaluation of anti-CD45 ARCs in lymphoma.


Assuntos
Anticorpos Monoclonais/uso terapêutico , Doença de Hodgkin/terapia , Imunoconjugados/uso terapêutico , Radioisótopos do Iodo/uso terapêutico , Antígenos Comuns de Leucócito/antagonistas & inibidores , Linfoma não Hodgkin/terapia , Transplante de Células-Tronco/métodos , Adulto , Idoso , Terapia Combinada , Feminino , Seguimentos , Doença de Hodgkin/patologia , Humanos , Antígenos Comuns de Leucócito/imunologia , Linfoma não Hodgkin/patologia , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/patologia , Recidiva Local de Neoplasia/terapia , Prognóstico , Radioimunoterapia , Terapia de Salvação , Taxa de Sobrevida , Adulto Jovem
9.
Br J Radiol ; 92(1103): 20190174, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31364397

RESUMO

OBJECTIVE: The effect of functional lung avoidance planning on radiation dose-dependent changes in regional lung perfusion is unknown. We characterized dose-perfusion response on longitudinal perfusion single photon emission computed tomography (SPECT)/CT in two cohorts of lung cancer patients treated with and without functional lung avoidance techniques. METHODS: The study included 28 primary lung cancer patients: 20 from interventional (NCT02773238) (FLARE-RT) and eight from observational (NCT01982123) (LUNG-RT) clinical trials. FLARE-RT treatment plans included perfused lung dose constraints while LUNG-RT plans adhered to clinical standards. Pre- and 3 month post-treatment macro-aggregated albumin (MAA) SPECT/CT scans were rigidly co-registered to planning four-dimensional CT scans. Tumour-subtracted lung dose was converted to EQD2 and sorted into 5 Gy bins. Mean dose and percent change between pre/post-RT MAA-SPECT uptake (%ΔPERF), normalized to total tumour-subtracted lung uptake, were calculated in each binned dose region. Perfusion frequency histograms of pre/post-RT MAA-SPECT were analyzed. Dose-response data were parameterized by sigmoid logistic functions to estimate maximum perfusion increase (%ΔPERFmaxincrease), maximum perfusion decrease (%ΔPERFmaxdecrease), dose midpoint (Dmid), and dose-response slope (k). RESULTS: Differences in MAA perfusion frequency distribution shape between time points were observed in 11/20 (55%) FLARE-RT and 2/8 (25%) LUNG-RT patients (p < 0.05). FLARE-RT dose response was characterized by >10% perfusion increase in the 0-5 Gy dose bin for 8/20 patients (%ΔPERFmaxincrease = 10-40%), which was not observed in any LUNG-RT patients (p = 0.03). The dose midpoint Dmid at which relative perfusion declined by 50% trended higher in FLARE-RT compared to LUNG-RT cohorts (35 GyEQD2 vs 21 GyEQD2, p = 0.09), while the dose-response slope k was similar between FLARE-RT and LUNG-RT cohorts (3.1-3.2, p = 0.86). CONCLUSION: Functional lung avoidance planning may promote increased post-treatment perfusion in low dose regions for select patients, though inter-patient variability remains high in unbalanced cohorts. These preliminary findings form testable hypotheses that warrant subsequent validation in larger cohorts within randomized or case-matched control investigations. ADVANCES IN KNOWLEDGE: This novel preliminary study reports differences in dose-response relationships between patients receiving functional lung avoidance radiation therapy (FLARE-RT) and those receiving conventionally planned radiation therapy (LUNG-RT). Following further validation and testing of these effects in larger patient populations, individualized estimation of regional lung perfusion dose-response may help refine future risk-adaptive strategies to minimize lung function deficits and toxicity incidence.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Relação Dose-Resposta à Radiação , Feminino , Humanos , Neoplasias Pulmonares/radioterapia , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão/métodos , Estudos Prospectivos , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada de Emissão de Fóton Único/métodos
10.
Clin Cancer Res ; 25(16): 5027-5037, 2019 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-31142507

RESUMO

PURPOSE: Prediction of spatially variant response to cancer therapies can inform risk-adaptive management within precision oncology. We developed the "Voxel Forecast" multiscale regression framework for predicting spatially variant tumor response to chemoradiotherapy on fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) imaging. EXPERIMENTAL DESIGN: Twenty-five patients with locally advanced non-small cell lung cancer, enrolled on the FLARE-RT phase II trial (NCT02773238), underwent FDG PET/CT imaging prior to (PETpre) and during week 3 (PETmid) of concurrent chemoradiotherapy. Voxel Forecast was designed to predict tumor voxel standardized uptake value (SUV) on PETmid from baseline patient-level and voxel-level covariates using a custom generalized least squares (GLS) algorithm. Matérn covariance matrices were fit to patient- specific empirical variograms of distance-dependent intervoxel correlation. Regression coefficients from variogram-based weights and corresponding standard errors were estimated using the jackknife technique. The framework was validated using statistical simulations of known spatially variant tumor response. Mean absolute prediction errors (MAEs) of Voxel Forecast models were calculated under leave-one-patient-out cross-validation. RESULTS: Patient-level forecasts resulted in tumor voxel SUV MAE on PETmid of 1.5 g/mL while combined patient- and voxel-level forecasts achieved lower MAE of 1.0 g/mL (P < 0.0001). PETpre voxel SUV was the most important predictor of PETmid voxel SUV. Patients with a greater percentage of under-responding tumor voxels were classified as PETmid nonresponders (P = 0.030) with worse overall survival prognosis (P < 0.001). CONCLUSIONS: Voxel Forecast multiscale regression provides a statistical framework to predict voxel-wise response patterns during therapy. Voxel Forecast can be extended to predict spatially variant response on multimodal quantitative imaging and may eventually guide optimized spatial-temporal dose distributions for precision cancer therapy.


Assuntos
Oncologia , Neoplasias/diagnóstico , Neoplasias/terapia , Medicina de Precisão , Análise de Regressão , Idoso , Ensaios Clínicos Fase II como Assunto , Ensaios Clínicos Fase III como Assunto , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Estimativa de Kaplan-Meier , Estudos Longitudinais , Masculino , Oncologia/métodos , Pessoa de Meia-Idade , Modelos Teóricos , Imagem Molecular/métodos , Imagem Multimodal , Análise Multivariada , Neoplasias/mortalidade , Medicina de Precisão/métodos , Prognóstico
11.
Curr Probl Diagn Radiol ; 47(5): 324-332, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28844319

RESUMO

Recognizing the different mechanisms and imaging appearance of extraskeletal Tc-99m methylene diphosphonate uptake enhances the diagnostic value of bone scan interpretation. In this article, we present a pictorial review of the different mechanisms of extraskeletal Tc-99m methylene diphosphonate uptake on bone scintigraphy including neoplastic, inflammatory, ischemic, traumatic, excretory, and iatrogenic. We also illustrate through case examples the added value of correlation with cross-sectional and single photon emission computed tomography and computed tomography imaging in localizing and characterizing challenging cases of extraskeletal uptake.


Assuntos
Doenças Ósseas/diagnóstico por imagem , Imagem Multimodal , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/farmacocinética , Medronato de Tecnécio Tc 99m/administração & dosagem , Medronato de Tecnécio Tc 99m/farmacocinética , Humanos , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X
12.
Nucl Med Commun ; 38(7): 577-586, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28591006

RESUMO

PURPOSE: A semiquantitative assessment of hepatic reticuloendothelial system function using colloidal particles scintigraphy has been proposed previously as a surrogate for liver function evaluation. In this article, we present an updated method for the overall assessment of technetium-99m (Tc)-sulfur colloid (SC) biodistribution that combines information from planar and attenuation-corrected Tc-SC single-photon emission computed tomography (SPECT) images. The imaging protocol described here was developed as an easy-to-implement method to assess overall and regional liver function changes associated with chronic liver disease. PATIENTS AND METHODS: Thirty patients with chronic liver disease and primary liver cancers underwent Tc-SC whole-body planar imaging and upper-abdomen SPECT/computed tomography (CT) imaging before external beam radiation therapy. Liver plus spleen and bone marrow counts as a fraction of whole-body total counts were calculated from SC planar imaging. Attenuation correction Tc-SC images were rigidly coregistered with treatment planning CT images that contained liver and spleen regions-of-interest. Ratios of total liver counts to total spleen counts were obtained from the aligned Tc-SC SPECT and CT images, and were subsequently used to separate liver plus spleen counts obtained on the planar images. This hybrid SPECT/CT and planar scintigraphy approach yielded an updated estimation of whole-body SC distribution. These biodistribution estimates were compared with historical data for reference. Statistical associations of Tc-SC biodistribution to liver function parameters and liver disease scoring systems (Child-Pugh) were evaluated by Spearman rank correlation. RESULTS: Percentages of Tc-SC uptake ranged from 19.3 to 77.3% for the liver; 3.4 to 40.7% for the spleen; and 19.0 to 56.7% for the bone marrow. Spearman's correlation coefficient showed a significant statistical association between Child-Pugh score and bone marrow uptake at 0.55 (P≤0.05), liver uptake at 0.71 (P≤0.001), spleen uptake at 0.56 (P≤0.05), and spleen plus bone marrow uptake at 0.71 (P≤0.001). There was also a good correlation of SC uptake percentages with individual quantitative liver function components such as albumin and total bilirubin, and qualitative liver function components (varices, portal hypertension, ascites). For albumin: r=0.64 (P<0.001) compared with liver uptake percentage from the whole-body counts, r=0.49 (P<0.001) compared with splenic uptake percentage, and r=0.45 (P≤0.05) compared with bone marrow uptake percentage. CONCLUSION: We describe a novel liver function quantitative assessment method that combines whole-body planar images and SPECT/CT attenuation-corrected images of Tc-SC distribution. Attenuation-corrected SC images provide valuable regional liver function information, which is a unique feature compared with other imaging methods available. The results of our study indicate that the Tc-SC uptake by the liver, spleen, and bone marrow correlates with liver function parameters in patients with diffuse liver disease and the correlation with liver disease severity is slightly better for liver uptake percentages than for individual values of bone marrow and spleen uptake percentages.


Assuntos
Fígado/diagnóstico por imagem , Fígado/fisiologia , Coloide de Enxofre Marcado com Tecnécio Tc 99m , Tomografia Computadorizada de Emissão de Fóton Único , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Coloide de Enxofre Marcado com Tecnécio Tc 99m/farmacocinética , Distribuição Tecidual
13.
Med Phys ; 44(7): 3418-3429, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28453861

RESUMO

PURPOSE: Nonsmall cell lung cancer (NSCLC) patient radiation therapy (RT) is planned without consideration of spatial heterogeneity in lung function or tumor response. We assessed the dosimetric and clinical feasibility of functional lung avoidance and response-adaptive escalation (FLARE) RT to reduce dose to [99m Tc]MAA-SPECT/CT perfused lung while redistributing an escalated boost dose within [18 F]FDG-PET/CT-defined biological target volumes (BTV). METHODS: Eight stage IIB-IIIB NSCLC patients underwent FDG-PET/CT and MAA-SPECT/CT treatment planning scans. Perfused lung objectives were derived from scatter/collimator/attenuation-corrected MAA-SPECT uptake relative to ITV-subtracted lung to maintain < 20 Gy mean lung dose (MLD). Prescriptions included 60 Gy to the planning target volume (PTV) and concomitant boost of 74 Gy mean to biological target volumes (BTV = GTV + PET gradient segmentation) scaled to each BTV voxel by relative FDG-PET SUV. Dose-painting-by-numbers prescriptions were integrated into commercial treatment planning systems via uptake threshold discretization. Dose constraints for lung, heart, cord, and esophagus were defined. FLARE RT plans were optimized with volumetric modulated arc therapy (VMAT), proton pencil beam scanning (PBS) with 3%-3 mm robust optimization, and combination of PBS (avoidance) plus VMAT (escalation). The high boost dose region was evaluated within a standardized SUVpeak structure. FLARE RT plans were compared to reference VMAT plans. Linear regression between radiation dose to BTV and normalized FDG PET SUV at every voxel was conducted, from which Pearson linear correlation coefficients and regression slopes were extracted. Spearman rank correlation coefficients were estimated between radiation dose to lung and normalized SPECT uptake. Dosimetric differences between treatment modalities were evaluated by Friedman nonparametric paired test with multiple sampling correction. RESULTS: No unacceptable violations of PTV and normal tissue objectives were observed in 24 FLARE RT plans. Compared to reference VMAT plans, FLARE VMAT plans achieved a higher mean dose to BTV (73.7 Gy 98195. 61.3 Gy), higher mean dose to SUVpeak (89.7 Gy vs. 60.8 Gy), and lower mean dose to highly perfused lung (7.3 Gy vs. 14.9 Gy). These dosimetric gains came at the expense of higher mean heart dose (9.4 Gy vs. 5.8 Gy) and higher maximum cord dose (50.1 Gy vs. 44.6 Gy) relative to the reference VMAT plans. Between FLARE plans, FLARE VMAT achieved higher dose to the SUVpeak ROI than FLARE PBS (89.7 Gy vs. 79.2 Gy, P = 0.01), while FLARE PBS delivered lower dose to lung than FLARE VMAT (11.9 Gy vs. 15.6 Gy, P < 0.001). Voxelwise linear dose redistribution slope between BTV dose and FDG PET uptake was higher in magnitude for FLARE PBS + VMAT (0.36 Gy per %SUVmax ) compared to FLARE VMAT (0.27 Gy per %SUVmax ) or FLARE PBS alone (0.17 Gy per %SUVmax ). CONCLUSIONS: FLARE RT is clinically feasible with VMAT and PBS. A combination of PBS for functional lung avoidance and VMAT for FDG PET dose escalation balanced target and normal tissue objective tradeoffs. These results provide a technical platform for testing of FLARE RT safety and efficacy within a precision radiation oncology trial.


Assuntos
Neoplasias Pulmonares/radioterapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Radioterapia (Especialidade) , Radioterapia de Intensidade Modulada
14.
Strahlenther Onkol ; 193(5): 410-418, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28255667

RESUMO

PURPOSE: To design and apply a framework for predicting symptomatic radiation pneumonitis in patients undergoing thoracic radiation, using both pretreatment anatomic and perfused lung dose-volume parameters. MATERIALS AND METHODS: Radiation treatment planning CT scans were coregistered with pretreatment [99mTc]MAA perfusion SPECT/CT scans of 20 patients who underwent definitive thoracic radiation. Clinical radiation pneumonitis was defined as grade ≥ 2 (CTCAE v4 grading system). Anatomic lung dose-volume parameters were collected from the treatment planning scans. Perfusion dose-volume parameters were calculated from pretreatment SPECT/CT scans. Equivalent doses in 2 Gy per fraction were calculated in the lung to account for differences in treatment regimens and spatial variations in lung dose (EQD2lung). RESULTS: Anatomic lung dosimetric parameters (MLD) and functional lung dosimetric parameters (pMLD70%) were identified as candidate predictors of grade ≥ 2 radiation pneumonitis (AUC > 0.93, p < 0.01). Pairing of an anatomic and functional dosimetric parameter (e. g., MLD and pMLD70%) may further improve prediction accuracy. Not all individuals with high anatomic lung dose (MLD > 13.6 GyEQD2lung, 19.3 Gy for patients receiving 60 Gy in 30 fractions) developed radiation pneumonitis, but all individuals who also had high mean dose to perfused lung (pMLD70% > 13.3 GyEQD2) developed radiation pneumonitis. CONCLUSIONS: The preliminary application of this framework revealed differences between anatomic and perfused lung dosimetry in this limited patient cohort. The addition of perfused lung parameters may help risk stratify patients for radiation pneumonitis, especially in treatment plans with high anatomic mean lung dose. Further investigations are warranted.


Assuntos
Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/radioterapia , Pneumonite por Radiação/diagnóstico , Pneumonite por Radiação/etiologia , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pneumonite por Radiação/prevenção & controle , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Medição de Risco/métodos , Sensibilidade e Especificidade , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Resultado do Tratamento
15.
EJNMMI Res ; 6(1): 57, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27349530

RESUMO

BACKGROUND: Assessment of liver function is critical in hepatocellular carcinoma (HCC) patient management. We evaluated parameters of [(99m)Tc] sulfur colloid (SC) SPECT/CT liver uptake for association with clinical measures of liver function and outcome in HCC patients. METHODS: Thirty patients with HCC and variable Child-Turcotte-Pugh scores (CTP A5-C10) underwent [(99m)Tc]SC SPECT/CT scans for radiotherapy planning. Gross tumor volume (GTV), anatomic liver volume (ALV), and spleen were contoured on CT. SC SPECT image parameters include threshold-based functional liver volumes (FLV) relative to ALV, mean liver-to-spleen uptake ratio (L/Smean), and total liver function (TLF) ratio derived from the product of FLV and L/Smean. Optimal SC uptake thresholds were determined by ROC analysis for maximizing CTP classification accuracy. Image metrics were tested for rank correlation to composite scores and clinical liver function parameters. Image parameters of liver function were tested for association to overall survival with Cox proportional hazard regression. RESULTS: Optimized thresholds on SC SPECT were 58 % of maximum uptake for FLV, 38 % for L/Smean, and 58 % for TLF. TLF produced the highest CTP classification accuracy (AUC = 0.93) at threshold of 0.35 (sensitivity = 0.88, specificity = 0.86). Higher TLF was associated with lower CTP score: TLFA = 0.6 (0.4-0.8) versus TLFB = 0.2 (0.1-0.3), p < 10(-4). TLF was rank correlated to albumin and bilirubin (|R| > 0.63). Only TLF >0.30 was independently associated with overall survival when adjusting for CTP class (HR = 0.12, 95 % CI = 0.02-0.58, p = 0.008). CONCLUSIONS: SC SPECT/CT liver uptake correlated with differential liver function. TLF was associated with improved overall survival and may aid in personalized oncologic management of HCC patients.

16.
Radiother Oncol ; 115(2): 203-10, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25934165

RESUMO

PURPOSE: To evaluate the feasibility of a novel planning concept that differentially redistributes RT dose away from functional liver regions as defined by (99m)Tc-sulphur colloid (SC) uptake on patient SPECT/CT images. MATERIALS AND METHODS: Ten HCC patients with different Child-Turcotte-Pugh scores (A5-B9) underwent SC SPECT/CT scans in treatment position prior to RT that were registered to planning CT scans. Proton pencil beam scanning (PBS) therapy plans were optimized to deliver 37.5-60.0Gy (RBE) over 5-15 fractions using single field uniform dose technique robust to range and setup uncertainty. Photon volumetrically modulated arc therapy (VMAT) plans were optimized to the same prescribed dose and minimum target coverage. For both treatment modalities, differential hepatic avoidance RT (DHART) plans were generated to decrease dose to functional liver volumes (FLV) defined by a range of thresholds relative to maximum SC uptake (43-90%) in the tumor-subtracted liver. Radiation dose was redistributed away from regions of increased SC uptake in each FLV by linearly scaling mean dose objectives during PBS or VMAT optimization. DHART planning feasibility was assessed by a significantly negative Spearman's rank correlation (RS) between dose difference and SC uptake. Patient, tumor, and treatment planning characteristics were tested for association to DHART planning feasibility using non-parametric Kruskal-Wallis ANOVA. RESULTS: Compared to conventional plans, DHART plans achieved a 3% FLV dose reduction for every 10% SC uptake increase. DHART planning was feasible in the majority of patients with 60% of patients having RS<-0.5 (p<0.01, range -1.0 to 0.2) and was particularly effective in 30% of patients (RS<-0.9). Mean dose to FLV was reduced by up to 20% in these patients. Only fractionation regimen was associated with DHART planning feasibility: 15 fraction courses were more feasible than 5-6 fraction courses (RS<-0.93 vs. RS>-0.60, p<0.02). CONCLUSION: Differential avoidance of functional liver regions defined on sulphur colloid SPECT/CT is achievable with either photon VMAT or proton PBS therapy. Further investigation with phantom studies and in a larger cohort of patients may validate the utility of DHART planning for HCC radiotherapy.


Assuntos
Carcinoma Hepatocelular/radioterapia , Neoplasias Hepáticas/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fracionamento da Dose de Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fótons/uso terapêutico , Doses de Radiação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X
17.
J Nucl Med ; 55(12): 2032-7, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25359880

RESUMO

UNLABELLED: Hepatocellular carcinoma (HCC) is an increasingly lethal malignancy for which management is critically dependent on accurate imaging. Glypican-3 (GPC3) is a cell surface receptor overexpressed in most HCCs and provides a unique target for molecular diagnostics. The use of monoclonal antibodies (mAbs) that target GPC3 (αGPC3) in PET imaging has shown promise but comes with inherent limitations associated with mAbs such as long circulation times. This study used (89)Zr-conjugated F(ab')2 fragments directed against GPC3 ((89)Zr-αGPC3-F(ab')2) to evaluate the feasibility of the fragments as a diagnostic immuno-PET imaging probe. METHODS: Immobilized ficin was used to digest αGPC3, creating αGPC3-F(ab')2 fragments subsequently conjugated to (89)Zr. In vivo biodistribution and PET studies were performed on GPC3-expressing HepG2 and GPC3-nonexpressing RH7777 orthotopic xenografts. RESULTS: Reliable αGPC3-F(ab')2 production via immobilized ficin digestion was verified by high-performance liquid chromatography and sodium dodecyl sulfate polyacrylamide gel electrophoresis. (89)Zr-αGPC3-F(ab')2 demonstrated F(ab')2-dependent, antigen-specific cell binding. HepG2 tumor uptake was higher than any other tissue, peaking at 100 ± 21 percentage injected dose per gram (%ID/g) 24 h after injection, a value 33- to 38-fold higher than GPC3-nonexpressing RH7777 tumors. The blood half-life of the (89)Zr-αGPC3-F(ab')2 conjugate was approximately 11 h, compared with approximately 115 h for historic mAb controls. This shorter half-life enabled clear tumor visualization on PET 4 h after administration, with a resultant peak tumor-to-liver contrast ratio of 23.3. Blocking antigen-expressing tumors with an excess of nonradiolabeled αGPC3 resulted in decreased tumor uptake similar to native liver. The kidneys exhibited high tissue uptake, peaking at 24 h with 83 ± 12 %ID/g. HepG2 tumors ranging from 1.5 to 7 mm were clearly visible on PET, whereas larger RH7777 tumors displayed signal lower than background liver tissue. CONCLUSION: This study demonstrates the feasibility of using (89)Zr-αGPC3-F(ab')2 for intrahepatic tumor localization with small-animal PET. Faster blood clearance and lower background liver uptake enable excellent signal-to-noise ratios at early time points. Increased renal uptake is similar to that as has been seen with clinical radioactive peptide imaging. (89)Zr-αGPC3-F(ab')2 addresses some of the shortcomings of whole-antibody immuno-PET probes. Further optimization is warranted to maximize probe sensitivity and specificity in the process of clinical translation.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Glipicanas/metabolismo , Fragmentos Fab das Imunoglobulinas , Neoplasias Hepáticas/diagnóstico por imagem , Compostos Radiofarmacêuticos , Animais , Feminino , Glipicanas/imunologia , Camundongos , Camundongos Nus , Radioisótopos , Cintilografia , Distribuição Tecidual , Imagem Corporal Total , Zircônio
18.
Mol Pharm ; 11(8): 2745-54, 2014 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-24957348

RESUMO

UNLABELLED: A novel positron emission tomography (PET) tracer, [(11)C]-rosuvastatin (RSV), was developed to dynamically and noninvasively measure hepatobiliary transport and tissue distribution of [(11)C]-RSV in rats. METHODS: Male Sprague-Dawley rats were administered either an Oatp inhibitor, rifampin (RIF, 40 mg/kg iv bolus plus 1.85 mg/min/kg iv infusion, n = 3), or the corresponding vehicle (saline, n = 3) for at least 90 min. Then, while these infusions were ongoing, the animals received [(11)C]-rosuvastatin (∼1 mCi/30 s, iv infusion). After [(11)C]-RSV administration, the lower abdominal region of the rats was imaged for 90 min. Time-activity curves for liver, intestine, and kidney were obtained and corrected for vascular content prior to noncompartmental and compartmental (five-compartment model) analysis. RESULTS: The majority of the [(11)C]-RSV dose was distributed into the liver. In the presence of RIF, the area under the [(11)C]-RSV radioactivity blood concentration-time profile (AUC0-90 min) was increased by ∼3-fold. Relative to the control animals, RIF reduced the distribution of [(11)C]-RSV radioactivity into the liver and kidney (tissue AUC0-15 min/blood AUC0-15 min) by 54% and 73% respectively. Compartmental modeling showed that RIF decreased CLBL, CLLI, CLBK, and CLK0 but had no effect on CLLB, where B, L, I, K, and 0 represent blood, liver, intestine, kidney, and irreversible loss. CONCLUSION: [(11)C]-RSV can be used to dynamically and noninvasively quantify hepatobiliary transport and hepatic concentration of the drug, in the absence and presence of drug interactions, in rats and could be used for the same purpose in humans.


Assuntos
Ductos Biliares/efeitos dos fármacos , Fluorbenzenos/farmacocinética , Fígado/efeitos dos fármacos , Transportadores de Ânions Orgânicos/metabolismo , Tomografia por Emissão de Pósitrons , Pirimidinas/farmacocinética , Sulfonamidas/farmacocinética , Animais , Área Sob a Curva , Bile/metabolismo , Ductos Biliares/diagnóstico por imagem , Transporte Biológico , Hepatócitos/efeitos dos fármacos , Rim/diagnóstico por imagem , Rim/efeitos dos fármacos , Fígado/diagnóstico por imagem , Masculino , Ratos , Ratos Sprague-Dawley , Rosuvastatina Cálcica , Fatores de Tempo , Distribuição Tecidual
19.
J Thorac Cardiovasc Surg ; 148(5): 2345-52, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24882061

RESUMO

OBJECTIVE: Lung cancer resection can require removal of an entire lobe and, at times, bilobectomy or pneumonectomy. Many patients will also have significantly compromised lung function that requires limiting the extent of surgery or could preclude surgery altogether. The preoperative assessment should include predicted postoperative forced expiratory volume in 1 second (ppoFEV1), because a ppoFEV1 of <40% predicts significantly increased perioperative morbidity. The ppoFEV1 can be estimated by multiplying the preoperative FEV1 by the residual perfused territory percentage, as predicted on planar perfusion scintigraphy (PPS). However, ppoFEV1 using PPS has shown variable correlation with spirometry-measured postoperative FEV1. METHODS: We propose an improved method for assessing regional lung perfusion in preoperative lung surgery patients. Patients undergo single photon emission computed tomography/computed tomography (SPECT/CT) imaging with attenuation correction using the conventional perfusion agent, technetium-99m-labeled macroaggregate of albumin. The CT image provides information for manual segmentation of each lobe. These segmentations are applied to the SPECT images to determine lobar perfusion. This proposed method was compared with PPS. RESULTS: This technique was evaluated in 17 patients. As expected, the perfusion contributions of the right and left lungs, calculated from SPECT/CT, correlated closely with those obtained from PPS (Pearson r=0.995). However, the lobar perfusion contributions obtained by PPS and SPECT/CT were significantly different, by 2 methods of comparison (Hotelling's P=1.7×10(-6) and P=1.7×10(-4)). CONCLUSIONS: This new SPECT/CT technique provides an anatomically more accurate assessment of lobar perfusion. This technique can refine which patients should be operative candidates and allow better prediction of postoperative function in contrast to the anatomically inaccurate planar scintigraphic predictions, which often underestimate the postoperative FEV1. This new technique is expected to have a significant effect on the resectability of patients with lung cancer.


Assuntos
Neoplasias Pulmonares/diagnóstico , Pulmão/irrigação sanguínea , Imagem de Perfusão/métodos , Circulação Pulmonar , Compostos Radiofarmacêuticos , Agregado de Albumina Marcado com Tecnécio Tc 99m , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Volume Expiratório Forçado , Humanos , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Pulmão/cirurgia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/fisiopatologia , Neoplasias Pulmonares/cirurgia , Imagem Multimodal , Seleção de Pacientes , Pneumonectomia , Valor Preditivo dos Testes , Cuidados Pré-Operatórios , Reprodutibilidade dos Testes
20.
J Nucl Med ; 55(5): 799-804, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24627434

RESUMO

UNLABELLED: Hepatocellular carcinoma (HCC) is a devastating malignancy in which imperfect imaging plays a primary role in diagnosis. Glypican-3 (GPC3) is an HCC-specific cell surface proteoglycan overexpressed in most HCCs. This paper presents the use of (89)Zr-conjugated monoclonal antibody against GPC3 ((89)Zr-αGPC3) for intrahepatic tumor localization using PET. METHODS: Polymerase chain reaction confirmed relative GPC3 expression in cell lines. In vitro binding, in vivo biodistribution, and small-animal PET studies were performed on GPC3-expressing HepG2 and non-GPC3-expressing HLF and RH7777 cells and orthotopic xenografts. RESULTS: (89)Zr-αGPC3 demonstrated antibody-dependent, antigen-specific tumor binding. HepG2 liver tumors exhibited high peak uptake (836.6 ± 86.6 percentage injected dose [%ID]/g) compared with background liver (27.5 ± 1.6 %ID/g). Tumor-to-liver contrast ratio was high and peaked at 32.5. The smallest HepG2 tumor (<1 mm) showed lower peak uptake (42.5 ± 6.4 %ID/g) and tumor-to-liver contrast (1.57) but was still clearly visible on PET. Day 7 tissue activity was still substantial in HepG2 tumors (466.4 ± 87.6 %ID/g) compared with control RH7777 tumors (3.9 ± 1.3 %ID/g, P < 0.01), indicating antigen specificity by (89)Zr-αGPC3. HepG2 tumor treated with unlabeled αGPC3 or heat-denatured (89)Zr-αGPC3 demonstrated tumor activity (2.1 %ID/g) comparable to that of control xenografts, confirming antibody dependency. CONCLUSION: This study demonstrated the feasibility of using (89)Zr-αGPC3 to image HCC in the liver, as well as the qualitative determination of GPC3 expression via small-animal PET. The ability to clarify the identity of small liver lesions with an HCC-specific PET probe would provide clinicians with vital information that could significantly alter patient management, warranting further investigation for clinical translation.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Glipicanas/química , Neoplasias Hepáticas/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Radioisótopos , Zircônio , Animais , Anticorpos Monoclonais/química , Linhagem Celular Tumoral , Colágeno/química , Combinação de Medicamentos , Feminino , Regulação Neoplásica da Expressão Gênica , Células Hep G2 , Humanos , Laminina/química , Fígado/patologia , Camundongos , Transplante de Neoplasias , Proteoglicanas/química , RNA Mensageiro/metabolismo , Compostos Radiofarmacêuticos , Distribuição Tecidual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA