Laryngoscope ; 130(12): E970-E975, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32176321

RESUMO

OBJECTIVES: To evaluate/compare normative electrophysiologic electromyography (EMG) response characteristics of recurrent laryngeal, vagus, and external branch of superior laryngeal nerve evoked with different stimulators used in neuromonitored thyroid surgery. STUDY DESIGN: Prospective crossover study METHODS: EMG responses obtained via endotracheal tube surface electrodes in 11 patients undergoing thyroid surgery were recorded when stimulated with four stimulators: two monopolar (Prass standard and ball tip), one bipolar, and one dissecting instrument. Normative mean EMG results including latency, amplitude, threshold, saturation currents, and distance-sensitivity were compared. RESULTS: The Prass standard stimulator had shorter latency time when nerve was not covered with fascia (P = .04). The bipolar, dissecting instrument, and ball tip demonstrated similar latency times with and without nerve fascia. Pooled mean latency increased significantly from 1.86 ms to 2.16 ms when comparing nerves without fascia and nerves with fascia (P < .05). The Prass standard monopolar stimulator had the lowest mean threshold at 0.40 mA, with the dissecting instrument having the highest threshold at 0.89 mA for dissected nerve. Pooled mean threshold and saturation increased from 0.6 mA to 1.7 mA (P < .0001) and 1.57 mA to 4.15 mA (P < .001) with fascia covering nerve, respectively. The mean depolarization rate was 100% for monopolar and bipolar electrodes and 81% for dissecting instrument at 1 mA. Only 9% of monopolar electrodes generated an EMG response when stimulated from 2 mm away. CONCLUSION: Monopolar stimulators are more sensitive for neural mapping, whereas bipolar instruments are more specific, thus reducing false positive stimulation. Dissecting instruments share many features of monopolar stimulators while being more specific, and thus are a viable alternative. LEVEL OF EVIDENCE: 2b Laryngoscope, 2020.


Assuntos
Estimulação Elétrica/instrumentação , Eletromiografia , Monitorização Intraoperatória/instrumentação , Doenças da Glândula Tireoide/cirurgia , Tireoidectomia/métodos , Estudos Cross-Over , Desenho de Equipamento , Humanos , Nervos Laríngeos/fisiologia , Laringoscópios , Estudos Prospectivos , Nervo Laríngeo Recorrente/fisiologia , Nervo Vago/fisiologia
4.
Laryngoscope ; 130(4): 1097-1104, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31361342

RESUMO

OBJECTIVE: To investigate intraoperative nerve monitoring (IONM) use among thyroid surgeons. METHODS: A 25-question survey was used to assess attitudes regarding IONM use. Surveys were sent to surgeons registered to the American Academy of Otolaryngology-Head and Neck Surgery, International Association of Endocrine Surgeons, and American Head and Neck Society. RESULTS: Among 1,015 respondents, 83% reported using IONM (65.1% always using IONM and 18.1% reporting selective use). For selective users, a majority reported using IONM for reoperative cases (95.1%) and in cases with preoperative vocal cord paralysis (59.8%). When comparing location, there was a significant difference in IONM implementation (P < 0.001), with 70.4% of North American responders using it ubiquitously compared to 27.4% of non-North American responders. Preoperative laryngeal exam was performed more universally by North American surgeons and more selectively by non-North American surgeons (P < 0.001). Other attitudes toward their implementation and the postoperative laryngeal exam were similar. Surgeons ≤45 years of age and those with ≤15 years of practice used IONM more than their peers (P < 0.001). Thyroid surgery volume, fellowship training, and type of practice had no bearing on IONM use. CONCLUSION: The prevalence of IONM in thyroid and parathyroid surgeries has increased significantly over the past decade, with 83% of surgeons using IONM in some or all cases. Although IONM use may be more ubiquitous in North America, attitudes toward its implementation and pre- and postoperative laryngeal exams are fairly uniform. IONM use is more prevalent among younger surgeons, whereas its use has no correlation with thyroid surgery volume or type of practice. LEVEL OF EVIDENCE: 4 Laryngoscope, 130:1097-1104, 2020.


Assuntos
Monitorização Intraoperatória/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Traumatismos do Nervo Laríngeo Recorrente/prevenção & controle , Tireoidectomia , Adulto , Idoso , Feminino , Humanos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Prevalência , Inquéritos e Questionários
5.
Laryngoscope ; 127(9): 2182-2188, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-27861939

RESUMO

OBJECTIVES/HYPOTHESIS: During intraoperative neural monitoring (IONM) in thyroid and parathyroid surgery, endotracheal (ET) tube migration can result in a decrease in vocalis electromyographic (EMG) amplitude without a concordant latency elevation during stimulation of the recurrent laryngeal nerve (RLN). STUDY DESIGN: Retrospective review. METHODS: Data were reviewed retrospectively for thyroid and parathyroid surgery patients with IONM of the laryngeal nerves from January 2015 to December 2015. Recordings of vocalis EMG amplitudes and latencies with RLN stimulation were obtained with the neuromonitoring ET tube surface electrodes in optimal baseline position, with vertical displacement away from the vocalis, and with rotational change away from baseline. RESULTS: ET tube surface electrode EMG recordings were obtained with stimulation of seven left and three right RLNs in a total of 10 patients. Mean vocalis EMG amplitudes were reduced with vertical displacement 1 and 2 cm both inferior and superior to baseline and with rotational change (45° and 90° clockwise and counterclockwise, 180°), although amplitude change with 45° clockwise and 180° rotation did not meet statistical significance. Mean EMG latency values did not change significantly from baseline with either rotation or vertical displacement of the ET tube. CONCLUSIONS: An isolated decrease in EMG amplitude without concordant latency elevation should warrant re-evaluation of ET tube position during thyroid and parathyroid surgery and is in contrast to a combined event, with both EMG amplitude decrease and concordant latency increase, which is more suggestive of a true neuropraxic injury. LEVEL OF EVIDENCE: 4. Laryngoscope, 127:2182-2188, 2017.


Assuntos
Eletromiografia/métodos , Migração de Corpo Estranho/fisiopatologia , Monitorização Neurofisiológica Intraoperatória/métodos , Intubação Intratraqueal/efeitos adversos , Glândula Tireoide/cirurgia , Adulto , Idoso , Fenômenos Eletrofisiológicos , Feminino , Migração de Corpo Estranho/etiologia , Humanos , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Masculino , Pessoa de Meia-Idade , Glândulas Paratireoides/cirurgia , Tempo de Reação , Nervo Laríngeo Recorrente/fisiopatologia , Nervo Laríngeo Recorrente/cirurgia , Estudos Retrospectivos , Adulto Jovem
6.
Plast Surg Int ; 2016: 6945297, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27293885

RESUMO

UNLABELLED: Objective. To evaluate the association between nasal obstruction and (1) demographic factors, (2) medical history, (3) physical tests, and (4) nasal exam findings. Study Design. CASE SERIES: Methods. Chart review at a tertiary medical center. Results. Two hundred-forty consecutive patients (52.1 ± 17.5 years old, with a Nasal Obstruction Symptom Evaluation (NOSE) score of 32.0 ± 24.1) were included. Demographic factors and inferior turbinate sizes were not associated with NOSE score or Nasal Obstruction Visual Analog Scale (NO-VAS). A significant association was found between higher NOSE score on univariate analysis and positive history of nasal trauma (p = 0.0136), allergic rhinitis (p < 0.0001), use of nasal steroids (p = 0.0108), higher grade of external nasal deformity (p = 0.0149), higher internal nasal septal deviation grade (p = 0.0024), and narrow internal nasal valve angle (p < 0.0001). Multivariate analysis identified the following as independent predictors of high NOSE score: NO-VAS: ≥50 (Odds Ratio (OR) = 17.6 (95% CI 5.83-61.6), p < 0.0001), external nasal deformity: grades 2-4 (OR = 4.63 (95% CI 1.14-19.9), p = 0.0339), and allergic rhinitis: yes (OR = 5.5 (95% CI 1.77-18.7), p = 0.0041). Conclusion. Allergic rhinitis, NO-VAS score ≥ 50, and external nasal deformity (grades 2-4) were statistically significant independent predictors of high NOSE scores on multivariate analysis. Inferior turbinate size was not associated with NOSE scores or NO-VAS.

7.
Orbit ; 34(1): 1-5, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25265475

RESUMO

BACKGROUND: Retrobulbar lesions of the orbit situated lateral to the optic nerve are difficult to access. In this article, the authors would like to present a new perspective to approach these lesions where the goals of surgery are met with minimal complications. METHODS: A retrospective analysis of patients' charts was performed. RESULTS: For approaching retrobulbar lesions an endoscopic technique was developed. Four patients (2 male and 2 female patients) presenting with retrobulbar lesions lateral to the optic nerve have been included in this study. Two patients underwent endoscopic drainage for orbital abscess and two patients were successfully biopsied endoscopically. No intra-operative complications were noted. Open procedures such as lateral orbitotomy were avoided in all the cases. CONCLUSION: Transcutaneous orbital endoscopy is a safe and a versatile technique to approach retrobulbar lesions lateral to the optic nerve. It can be used as an effective alternative to lateral orbitotomy for well selected cases. One can obtain adequate material for histopathological examination and also drain deep-seated orbital abscess using this technique. It would be possible with increasing experience to use this technique for extended applications.


Assuntos
Endoscopia/métodos , Doenças Orbitárias/cirurgia , Adolescente , Adulto , Biópsia , Diagnóstico por Imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Orbitárias/diagnóstico , Estudos Retrospectivos , Resultado do Tratamento
8.
Indian J Otolaryngol Head Neck Surg ; 65(Suppl 1): 1-5, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24427607

RESUMO

Soft tissue sarcomas of head and neck region, account for 4-15% of all soft tissue sarcomas and less than 1% of all neoplasms in this region. Leiomyosarcoma is malignant tumor of smooth muscle which accounts for only 4% of head and neck sarcomas. The tumor is commonly encountered as a slow growing, discrete firm, and non-ulcerated painless mass. The physical appearance of these tumors can be deceptively benign and can be mistaken for non-malignant conditions. An early diagnosis and aggressive initial treatment remains the mainstay of therapy for a good prognosis. We are presenting eight cases of primary leiomyosarcoma of head and neck region with review of literature and highlight the need for early prudent diagnosis and treatment.

9.
Otolaryngol Head Neck Surg ; 144(4): 581-5, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21493239

RESUMO

OBJECTIVE: Genuine concerns are being raised as to the potential health risks posed by electromagnetic frequency exposure secondary to mobile phone usage. This study was undertaken to assess and compare potential changes in hearing function at the level of the inner ear and central auditory pathway due to chronic exposure to electromagnetic waves from both global system for mobile communications (GSM) and code division multiple access (CDMA) mobile phone usage. DESIGN: Cohort study. SETTING: Tertiary referral center. SUBJECTS AND METHODS: One hundred twenty-five subjects who were long-term mobile phone users (more than 1 year; 63 GSM and 62 CDMA) and 58 controls who had never used mobile phones underwent audiological investigations including pure tone audiometry (250-12 kHz), tympanometry, distortion product otoacoustic emissions (DPOAE), auditory brain responses (ABR), and middle latency responses (MLRs). The changes in various parameters were studied in mobile-using and non-mobile-using ears of both GSM and CDMA subjects and corresponding ears of the controls to ascertain the effects of electromagnetic exposure. RESULTS: GSM and CDMA users were found to be at a significantly higher risk of having DPOAE absent as compared with controls (P < .05). They were found to have higher speech frequency thresholds and lower MLR wave and Na and Pa amplitudes. More than 3 years of mobile phone usage emerged as a risk factor (P < .05). The damage done was bilateral, with the quantum of damage being the same for both GSM and CDMA. CONCLUSION: Long-term and intensive GSM and CDMA mobile phone use may cause damage to cochlea as well as the auditory cortex.


Assuntos
Telefone Celular , Campos Eletromagnéticos , Perda Auditiva/etiologia , Adulto , Audiometria de Tons Puros , Doenças Auditivas Centrais/etiologia , Limiar Auditivo , Potenciais Evocados Auditivos do Tronco Encefálico , Feminino , Humanos , Masculino , Emissões Otoacústicas Espontâneas , Tempo de Reação
10.
Anticancer Drugs ; 19(9): 841-8, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18765998

RESUMO

Malignant pleural mesothelioma (MPM) is a disease with few therapeutic options. Protein kinase C beta (PKCbeta) is involved in important cellular functions. Enzastaurin (LY317615.HCl) is a novel inhibitor of PKC in clinical development. MPM cell lines (7) and patient tumor tissues (24) were evaluated for expression of PKCbeta by immunoblotting and immunohistochemistry, respectively. In-vitro cell growth assays were performed with enzastaurin with or without cisplatin. Cell migration was evaluated with the wound healing assay. Downstream signaling (survival and focal adhesion pathways) was studied by immunoblotting for related molecules in the presence of phorbol ester with or without enzastaurin. Expression for PKCbeta1 was seen in all cases, with a mean integrated optical density of 152.5 (standard deviation=95.47, n=24), whereas PKCbeta2 expression was less intense, with a mean integrated optical density of 11.45 (standard deviation=16.27, n=21). There was a trend toward lower overall survival among patients expressing above-median PKCbeta1 (P=0.064), but not PKCbeta2. Robust expression of PKCbeta1 and low expression of PKCbeta2 were observed in MPM cell lines. Treatment of MPM cell lines with enzastaurin revealed an IC50 of 5 micromol/l, and strong synergism was observed when combined with cisplatin. Wound healing assay revealed that treatment of H2461 cells with enzastaurin reduced migration by 59.2%. Enzastaurin treatment led to disruption of F-actin architecture. Downstream signaling showed reduced phosphorylation of AKT, FAK (focal adhesion kinase), p130Cas, S6 ribosomal protein, and paxillin. PKCbeta1 was expressed in the majority of MPM samples. Enzastaurin has preclinical activity against MPM, and exhibited synergism with cisplatin. PKCbeta inhibition in MPM might be able to reduce the invasiveness of MPM by affecting cytoskeletal function.


Assuntos
Indóis/farmacologia , Mesotelioma/metabolismo , Neoplasias Pleurais/metabolismo , Proteína Quinase C/fisiologia , Linhagem Celular Tumoral , Movimento Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Cisplatino/farmacologia , Humanos , Concentração Inibidora 50 , Ésteres de Forbol/farmacologia , Fosforilação , Proteína Quinase C/antagonistas & inibidores , Proteína Quinase C beta , Inibidores de Proteínas Quinases/farmacologia , Taxa de Sobrevida