Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Heliyon ; 10(9): e30030, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38707442

RESUMO

Objective: To investigate the knowledge of diagnostic reference levels (DRLs), image quality, radiation dose and protocol parameters among Jordanian medical imaging professionals (MIPs) involved in PET/CT and CT scan procedures. Materials and methods: A questionnaire was designed and distributed to MIPs in Jordan. The survey comprised four sections: demographic data, MIP knowledge on dose/protocol parameters, image quality, and DRLs. Statistical analyses were performed utilizing Pearson's correlation, t-tests, ANOVA, and linear regression, with a significance level of 95 % and a p-value threshold of <0.05. Results: The study involved 147 participants. Most respondents were male (76.2 %), and most were aged 26-35 years (44.2 %). Approximately 51 % held a bachelor's degree, and the most common range of experience was 3-5 years (28.6 %). Participants showed a moderate level of knowledge regarding dose and protocol parameters, with a mean score of 61.8 %. The mean scores for knowledge of image quality and DRLs were 45.2 % and 44.8 %, respectively. The age group of the MIPs and the total experience were found to have a significant impact on the knowledge of the dose and protocol parameters, as well as the DRLs. Additionally, experience was found to have a significant influence on knowledge of the dose and protocol parameters. The study revealed a positive and significant effect of MIPs' knowledge of dose/protocol parameters and image quality on their knowledge of DRLs. Conclusions: This study indicates that professionals across five specialties who are engaged in PET/CT and CT imaging possess a moderate understanding of dosage and protocol parameters. However, there is a notable gap in knowledge regarding DRLs and image quality. To address this issue, it is recommended that MIPs actively engage in educational programs emphasizing exposure parameters and their impact on image quality. Additionally, access to comprehensive education and training programs will enable MIPs to grasp the complexities of DRLs and their implications, facilitating their implementation in clinical practice.

2.
J Radiol Prot ; 44(1)2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38387102

RESUMO

This study aims to report the findings of Jordanian national diagnostic reference level (NDRL) survey for fluorodeoxyglucose (18F-FDG) and local diagnostic reference level (LDRL) of computed tomography (CT) used for attenuation correction and anatomical localisation (AC-AL); and AC and diagnostic CT (AC-DX) within the context of whole-body WB and half-body HB adult oncology PET/CT scanning. Two-structured questionnaires were prepared to gather the necessary information: dosimetry data, patient demographics, equipment specification, and acquisition protocols for identified18F-FDG PET/CT procedures. The NDRL and achievable dose were reported based on the 75th and 50th percentiles for18F-FDG administered activity (AA), respectively. The LDRL was reported based on the 50th percentile for (CTDIvol) and (DLP). Data from 562 patients from four Jordanian PET/CT centres were collected. The survey revealed that Jordanian NDRL for AA (303 MBq) was within the acceptable range compared to the published-peer NDRL data (240-590 MBq). However, the18F-FDG AA varied across the participated PET/CT centres. The reported LDRL CTDIvoland DLP of CT used for (AC-AL) was 4.3 mGy and 459.3 mGy.cm for HB CT scan range, and 4.1 mGy and 659.9 mGy.cm for WB CT scans. The reported LDRL for CTDIvoland DLP for HB CT was higher when compared with the United Kingdom (3.2 mGy and 310 mGy.cm). Concurrently, in the context of WB CT, the reported values (i.e. CTDIvol and DLP) were also higher than both Kuwait (3.6 mGy and 659 mGy.cm) and Slovenia (3.6 mGy and 676 mGy.cm). The reported HB CT(AC-DX) was higher than Nordic, New Zealand and Swiss NDRLs and for WB (AC-DX) CT it was higher than Swiss NDRLs. This study reported the first Jordanian NDRL for18F-FDG and LDRL for HB and WB CT associated with18F-FDG PET/CT scans. This data is useful for Jordanian PET/CT centres to compare their LDRL to the suggested DRLs and utilise it in the process of optimising CT radiation doses.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adulto , Humanos , Níveis de Referência de Diagnóstico , Doses de Radiação , Jordânia , Valores de Referência , Tomografia Computadorizada por Raios X
3.
Nucl Med Commun ; 44(11): 937-943, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37615527

RESUMO

PET-computed tomography (PET/CT) is a hybrid imaging technique that combines anatomical and functional information; to investigate primary cancers, stage tumours, and track treatment response in paediatric oncology patients. However, there is debate in the literature about whether PET/CT could increase the risk of cancer in children, as the machine is utilizing two types of radiation, and paediatric patients have faster cell division and longer life expectancy. Therefore, it is essential to minimize radiation exposure by justifying and optimizing PET/CT examinations and ensure an acceptable image quality. Establishing diagnostic reference levels (DRLs) is a crucial quantitative indicator and effective tool to optimize paediatric imaging procedures. This review aimed to distinguish and acknowledge variations among published DRLs for paediatric patients in PET/CT procedures. A search of relevant articles was conducted using databases, that is, Embase, Scopus, Web of Science, and Medline, using the keywords: PET-computed tomography, computed tomography, PET, radiopharmaceutical, DRL, and their synonyms. Only English and full-text articles were included, with no limitations on the publication year. After the screening, four articles were selected, and the review reveals different DRL approaches for paediatric patients undergoing PET/CT, with primary variations observed in patient selection criteria, reporting of radiation dose values, and PET/CT equipment. The study suggests that future DRL methods for paediatric patients should prioritize data collection in accordance with international guidelines to better understand PET/CT dose discrepancies while also striving to optimize radiation doses without compromising the quality of PET/CT images.


Assuntos
Níveis de Referência de Diagnóstico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Criança , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X , Compostos Radiofarmacêuticos , Valores de Referência
4.
Acad Radiol ; 29 Suppl 3: S114-S121, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-29054676

RESUMO

RATIONALE AND OBJECTIVE: This study is a dedicated 2D-shear wave elastography (2D-SWE) review aimed at systematically eliciting up-to-date evidence of its clinical value in differential diagnosis of benign and malignant thyroid nodules. METHODS: PubMed, Web of Science, and Scopus databases were searched for studies assessing the diagnostic value of 2D-SWE for thyroid malignancy risk stratification published until December 2016. The retrieved titles and abstracts were screened and evaluated according to the predefined inclusion and exclusion criteria. Methodological quality of the studies was assessed using the Quality Assessment of Studies of Diagnostic Accuracy included in Systematic Review 2 (QUADAS-2) tool. Extracted 2D-SWE diagnostic performance data were meta-analyzed to assess the summary sensitivity, specificity, and area under the receiver operating characteristic curve. RESULTS: After stepwise review, 14 studies in which 2D-SWE was used to evaluate 2851 thyroid nodules (1092 malignant, 1759 benign) from 2139 patients were selected for the current study. Study quality on QUADAS-2 assessment was moderate to high. The summary sensitivity, specificity and area under the receiver operating characteristic curve of 2D-SWE for differential diagnosis of benign and malignant thyroid nodules were 0.66 (95% confidence interval [CI]: 0.64-0.69), 0.78 (CI: 0.76-0.80), and 0.851 (Q* = 0.85), respectively. The pooled diagnostic odds ratio, negative likelihood ratio, and positive likelihood ratio were 12.73 (CI: 8.80-18.43), 0.31 (CI: 0.22-0.44), and 3.87 (CI: 2.83-5.29), respectively. CONCLUSION: Diagnostic performance of quantitative 2D-SWE for malignancy risk stratification of thyroid nodules is suboptimal with mediocre sensitivity and specificity, contrary to earlier reports of excellence.


Assuntos
Técnicas de Imagem por Elasticidade , Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Diagnóstico Diferencial , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia
5.
J Alzheimers Dis ; 82(2): 673-687, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34092633

RESUMO

BACKGROUND: Cognitive frailty (CF) is identified as one of the main precursors of dementia. Multidomain intervention has been found to delay or prevent the onset of CF. OBJECTIVE: The aim of our present study is to determine the effectiveness of a comprehensive, multidomain intervention on CF; to evaluate its cost effectiveness and the factors influencing adherence toward this intensive intervention. METHODS: A total of 1,000 community dwelling older adults, aged 60 years and above will be screened for CF. This randomized controlled trial involves recruitment of 330 older adults with CF from urban, semi-urban, and rural areas in Malaysia. Multidomain intervention comprised of physical, nutritional, cognitive, and psychosocial aspects will be provided to participants in the experimental group (n = 165). The control group (n = 165) will continue their usual care with their physician. Primary outcomes include CF status, physical function, psychosocial and nutritional status as well as cognitive performance. Vascular health and gut microbiome will be assessed using blood and stool samples. A 24-month intensive intervention will be prescribed to the participants and its sustainability will be assessed for the following 12 months. The effective intervention strategies will be integrated as a personalized telerehabilitation package for the reversal of CF for future use. RESULTS: The multidomain intervention developed from this trial is expected to be cost effective compared to usual care as well as able is to reverse CF. CONCLUSION: This project will be part of the World-Wide FINGERS (Finnish Geriatric Intervention Study to Prevent Cognitive Impairment and Disability) Network, of which common identifiable data will be shared and harmonized among the consortia.


Assuntos
Cognição/fisiologia , Disfunção Cognitiva , Dieta Saudável/métodos , Idoso Fragilizado/psicologia , Desempenho Físico Funcional , Serviços Preventivos de Saúde , Intervenção Psicossocial/métodos , Idoso , Disfunção Cognitiva/diagnóstico , Disfunção Cognitiva/fisiopatologia , Disfunção Cognitiva/prevenção & controle , Disfunção Cognitiva/psicologia , Análise Custo-Benefício , Feminino , Humanos , Vida Independente , Masculino , Programas de Rastreamento/métodos , Serviços Preventivos de Saúde/economia , Serviços Preventivos de Saúde/métodos , Avaliação de Programas e Projetos de Saúde , Ensaios Clínicos Controlados Aleatórios como Assunto , Telerreabilitação/métodos
6.
Asian Pac J Cancer Prev ; 20(5): 1427-1432, 2019 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-31127903

RESUMO

Objective: This study aims to investigate the public pattern in seeking breast cancer screening information in Malaysia using Google Trends. Methods: The Google Trends database was evaluated for the relative Internet search popularity of breast cancer and screening-related search terms from 2007 to 2018. Results: Result showed downward trends in breast cancer search, whereas mammogram and tomosynthesis search fluctuated consistently. A significant increment was found during Pink October month. Breast cancer search term achieved the highest popularity in the east coast of Malaysia with [x2 (5, N=661) = 110.93, P<0.05], whereas mammogram attained the highest search volume in central Malaysia [x2 (4, N=67) = 18.90, P<0.05]. The cross-correlation for breast cancer was moderate among northern Malaysia, Sabah, and Sarawak (0.3 ≤ rs ≤ 0.7). Conclusion: Public interest trend in breast cancer screening is strongly correlated with the breast cancer awareness campaign, Pink October. Breast cancer screening should be promoted in the rural areas in Malaysia.


Assuntos
Neoplasias da Mama/diagnóstico , Detecção Precoce de Câncer/estatística & dados numéricos , Comportamento de Busca de Informação , Internet/estatística & dados numéricos , Mamografia/estatística & dados numéricos , Ferramenta de Busca/tendências , Neoplasias da Mama/psicologia , Detecção Precoce de Câncer/psicologia , Feminino , Humanos , Malásia , Prognóstico
7.
Radiat Prot Dosimetry ; 162(3): 316-21, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24255172

RESUMO

A study on the radiation dose associated with cerebral CT angiography (CTA) and CT perfusion (CTP) was conducted on an anthropomorphic phantom with the aim of estimating the effective dose (E) and entrance skin dose (ESD) in the eyes and thyroid gland during different CTA and CTP protocols. The E was calculated to be 0.61 and 0.28 mSv in CTA with 100 and 80 kV(p), respectively. In contrast, CTP resulted in an estimated E of 2.74 and 2.07 mSv corresponding to 40 and 30 s protocols, respectively. The eyes received a higher ESD than the thyroid gland in all of these protocols. The results of this study indicate that combining both CTA and CTP procedures are not recommended in the stroke evaluation due to high radiation dose. Application of modified techniques in CTA (80 kV(p)) and CTP (30 s) is highly recommended in clinical practice for further radiation dose reduction.


Assuntos
Encéfalo/diagnóstico por imagem , Angiografia Cerebral/métodos , Imagens de Fantasmas , Pele/diagnóstico por imagem , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Encéfalo/efeitos da radiação , Feminino , Humanos , Perfusão , Doses de Radiação , Pele/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA