Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 203
Filtrar
1.
Herz ; 41(1): 10-8, 2016 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-26659846

RESUMO

Mitral valve (MV) disease is one of the most common heart valve diseases. The surgical and interventional treatment for MV disease requires a multidisciplinary approach. For primary mitral valve regurgitation (MVR) surgical MV repair is the treatment of choice, which can be performed with an excellent outcome and long-term survival in reference centers. The surgical technique used for MV repair depends on the pathological mechanism, the morphological dimensions of the MV, the operative risk and the expertise of the cardiac surgeon. The surgical and interventional treatment of secondary MVVR is the subject of on-going discussions. In patients with moderate secondary MVR undergoing coronary artery bypass grafting, concomitant MV repair should be performed. In the presence of severe secondary MR with risk factors for failure of MV repair, patients should consider having MV replacement. In the rare cases of patients presenting with mitral valve stenosis (MVS) MV repair can be considered in young patients and who are most often treated with MV replacement. The choice between biological or mechanical MV replacement depends on the pathophysiology, the comorbidities, the amount of anticoagulation necessary and the age of the patient. New percutaneous techniques for MV replacement offer new treatment options for reoperation in high-risk patients.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/cirurgia , Estenose da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Terapia Combinada/métodos , Próteses Valvulares Cardíacas , Humanos , Procedimentos de Cirurgia Plástica/instrumentação
2.
J Cardiovasc Surg (Torino) ; 56(5): 745-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25990022

RESUMO

Unresolved for over half a century now since the beginning of aortic surgery spinal cord injury (SCI) remains the most devastating complication after extensive open and endovascular thoracoabdominal aortic aneurysm (TAA/A) repair. Over the past decade extensive research on spinal cord perfusion lead to a better understanding of previously unknown physiologic mechanisms involved in the suspension of the cord's arterial supply and the consecutive development of SCI underscoring the need for new concepts in treatment strategy and monitoring methods during and after TAA/A repair. Based on this knowledge, new treatment strategies in particular the staged-repair were developed. The first-in-man translation of this idea has just been published introducing the new concept: minimally invasive selective segmental artery coil-embolization. Another approach to overcome the most critical initial period after segmental artery occlusion due to stent graft deployment in the descending or thoracoabdominal aorta is temporary aneurysm sac perfusion, which also has recently been clinically trialed. Furthermore, the new non-invasive real-time monitoring method to record spinal cord viability by means of near-infrared spectroscopy of the paraspinal collateral network by means of near-infrared spectroscopy has also been suggested and successfully introduced in a pilot series to a clinical setting. This review addresses problems, unsolved questions and future perspectives regarding these three new concepts.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Traumatismos da Medula Espinal/prevenção & controle , Isquemia do Cordão Espinal/prevenção & controle , Medula Espinal/irrigação sanguínea , Animais , Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/fisiopatologia , Humanos , Monitorização Neurofisiológica Intraoperatória/métodos , Valor Preditivo dos Testes , Fatores de Risco , Espectroscopia de Luz Próxima ao Infravermelho , Traumatismos da Medula Espinal/diagnóstico , Traumatismos da Medula Espinal/etiologia , Traumatismos da Medula Espinal/fisiopatologia , Isquemia do Cordão Espinal/diagnóstico , Isquemia do Cordão Espinal/etiologia , Isquemia do Cordão Espinal/fisiopatologia , Resultado do Tratamento
3.
Chirurg ; 86(3): 228-33, 2015 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-25693778

RESUMO

With an incidence rate of 0.5-4 % and a mortality of up to 50 %, deep sternal wound infections are a rare but devastating complication after median sternotomy for cardiac surgery. Currently, no standard operating procedures exist. Long-term drainage with continuous lavage or negative pressure wound therapy should be used to condition the wound. After restabilization of the sternum and primary closure, the infection often reoccurs presenting deep cavities with an open, unstable thorax and an uncovered mediastinum. This article gives an overview of the different options for deep sternal wound infections in plastic reconstructive surgery. The key point for successful treatment is still the extent of debridement. Primary coverage with a pedicled flap can be made only if the wound debridement was performed radically enough. In the clinic of the author, in which over 120 patients with deep sternal wound infections were treated in 2.5 years, latissimus dorsi muscle flaps have been established as the gold standard.


Assuntos
Cardiopatias/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Complicações Pós-Operatórias/cirurgia , Esternotomia , Infecção da Ferida Cirúrgica/cirurgia , Desbridamento/métodos , Humanos , Retalho Miocutâneo/cirurgia , Osteomielite/cirurgia
4.
Perfusion ; 30(2): 154-60, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24988948

RESUMO

OBJECTIVES: Mechanical lung assist (MLA; extracorporeal membrane oxygenation (ECMO) or extracorporeal lung assist (ECLA)) is increasingly used as a temporary bridge to lung transplantation (LTx). This study was designed to evaluate the impact of preoperative MLA on the operative outcome, including longer-term survival, in comparison to patients undergoing LTx without preoperative MLA. METHODS: A total of 143 patients underwent LTx at our institution from 2002 to 2011. Forty-three percent (n=62) of patients presented with idiopathic pulmonary fibrosis and 71% (n=102) presented with severely elevated pulmonary artery pressure. RESULTS: Thirteen patients (9.1%) required pre-LTx MLA support (age 44 ±13 years, double LTx 73.3%, female gender 53%) whereas 130 patients did not (age 52 ±11 years, double LTx 41.5%, female gender 36.9%). In one patient, MLA was successfully weaned and the patient underwent subsequent LTx. All patients in the MLA group were intraoperatively supported with continuous ECMO. One patient had to be supported with MLA after LTx for a period of 8 days. The short-term and mid-term postoperative survival of the MLA patient group was not significantly different from the non-MLA group (LogRank p=0.28). The 30-day, 90-day and 1-year survivals were 95%, 90% and 71%, respectively, in the patients without MLA compared to 85%, 77% and 68% in the MLA group. CONCLUSIONS: MLA has no impact on long-term survival rate in LTx patients, but has an influence in postoperative survival. MLA support is a valuable tool to bridge unstable patients to LTx.


Assuntos
Oxigenação por Membrana Extracorpórea , Hipertensão Pulmonar , Fibrose Pulmonar Idiopática , Transplante de Pulmão , Cuidados Pré-Operatórios , Respiração Artificial , Adulto , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Hipertensão Pulmonar/mortalidade , Hipertensão Pulmonar/cirurgia , Fibrose Pulmonar Idiopática/mortalidade , Fibrose Pulmonar Idiopática/cirurgia , Masculino , Pessoa de Meia-Idade , Taxa de Sobrevida
6.
Med Eng Phys ; 36(11): 1480-6, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25183045

RESUMO

Stent graft fixation in the vessel affects the success of endovascular aneurysm repair. Thereby the radial forces of the stent, which are dependent on several factors, play a significant role. In the presented work, a finite element sensitivity study was performed. The radial forces are 29% lower when using the hyperelastic approach for the vessel compared with linear elastic assumptions. Without the linear elastic modeled plaque, the difference increases to 35%. Modeling plaque with linear elastic material approach results in 8% higher forces than with a hyperelastic characteristic. The significant differences resulting from the investigated simplifications of the material lead to the conclusion that it is important to apply an anisotropic nonlinear approach for the vessel. The oversizing study shows that radial forces increase by 64% (0.54 N) when raising the oversize from 10 to 22%, and no further increase in force can be observed beyond these values (vessel diameter D=12 mm). Starting from an oversize of 24%, the radial force steadily decreases. The findings of the investigation show that besides the oversizing the material properties, the ring design and the vessel characteristics have an influence on radial forces.


Assuntos
Ligas , Vasos Sanguíneos , Fenômenos Mecânicos , Stents , Fenômenos Biomecânicos , Análise de Elementos Finitos , Incerteza
7.
Chirurg ; 85(9): 758, 760-66, 2014 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-25200626

RESUMO

BACKGROUND: The treatment of patients with aneurysms of the ascending aorta and aortic arch often represents a challenge due to their complexity. The clinical picture is characterized by further progression of the disease and severe complications, such as acute aortic dissection or even aortic rupture are not uncommon. OBJECTIVES: This article gives a review of definitions, etiology and indications for operative treatment of patients with aneurysms of the ascending aorta and aortic arch. RESULTS AND DISCUSSION: An aortic aneurysm of the ascending aorta is defined as a dilatation of all wall layers of the aorta of more than 50 % in comparison to the normal diameter. This is dependent on age, sex, body surface area and the underlying diseases. In most cases the cause is the presence of atherosclerosis. Connective tissue diseases, bicuspid or monocuspid aortic valves and aortitis represent additional risk factors. Surgical treatment of the ascending aorta, aortic root and aortic arch is carried out in patients without connective tissue diseases and a diameter of ≥ 55 mm and for patients with Marfan syndrome and bicuspid aortic valves with a diameter of ≥ 50 mm. Earlier indications for surgery are present with an aortic diameter of ≥ 45 mm in patients with the following risk factors: familial disposition for aortic dissection (often unrecognized as sudden cardiac death), annual growth rate of the aortic diameter of > 2 mm, comorbid severe aortic valve or mitral valve insufficiency and female patients with a desire to have children. The standard surgical procedures include aortic root replacement, aortic valve reconstruction with aortic root or ascending aorta replacement and partial or total aortic arch replacement depending on the extent of the aneurysm. The so-called hybrid procedures for aortic arch surgery include frozen elephant trunk (ET) techniques and debranching procedures. Good perioperative and postoperative results can be achieved by early diagnostics and an assessment of the indications depending on the individual etiology. Individual and valve-preserving treatment strategies have a favorable influence on the operative outcome.


Assuntos
Aorta Torácica/cirurgia , Aorta/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/etiologia , Ruptura Aórtica/diagnóstico , Ruptura Aórtica/etiologia , Ruptura Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese Vascular , Progressão da Doença , Implante de Prótese de Valva Cardíaca , Humanos , Prognóstico , Fatores de Risco
8.
Z Gastroenterol ; 52(8): 813-7, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25111721

RESUMO

Invasive aspergillus infection occurs in 5 - 42 % of liver-transplanted recipients and is a dangerous complication, associated with high mortality if untreated. However, the early diagnosis of invasive aspergillosis can be elusive, as clinical signs are unspecific and the pathogenic agent is difficult to demonstrate. We here report about a 58-year-old man with acute liver failure caused by newly diagnosed chronic hepatitis B infection who underwent liver transplantation. The postoperative course was uneventful, and the patient was discharged after 30 days. After 105 days the patient was readmitted because of fever, recurrent chest and abdominal pain. Computed tomography revealed a cardiac lesion; other diagnostic steps including bone-marrow and endomycordial biopsy, virological and microbiological investigations gave no clear findings. To exclude a malignant process, thoracotomy with mass and simultaneous lower left lobe resection were performed. Histopathological findings revealed an invasive perimyocardial aspergillosis. Immediate intravenous therapy with voriconazole and caspofungin was initiated and monitoring of the mass was performed with transesophageal echocardiography and Cardio-MRI. Due to slightly increase of the lesion, medication was switched to posaconazole and caspofungin. Under this dual fungal treatment the lesion regressed and the patient could be discharged after two months in good clinical condition. Frequent Cardio-MRI scan after discharge showed further mass-regression. Therefore antifungal treatment was switched to oral posaconazole mono-therapy. After one year, complete reduction of the mass was achieved and antifungal therapy was discontinued. Recent diagnostic imaging follow-up showed no pathological finding.


Assuntos
Hepatite B/cirurgia , Falência Hepática/cirurgia , Transplante de Fígado , Miocardite/diagnóstico , Infecções Oportunistas/diagnóstico , Complicações Pós-Operatórias/diagnóstico , Aspergilose Pulmonar/diagnóstico , Doença Aguda , Caspofungina , Quimioterapia Combinada , Equinocandinas/uso terapêutico , Ecocardiografia Transesofagiana , Humanos , Lipopeptídeos , Pulmão/patologia , Pulmão/cirurgia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Miocardite/tratamento farmacológico , Miocardite/patologia , Miocárdio/patologia , Infecções Oportunistas/tratamento farmacológico , Infecções Oportunistas/patologia , Complicações Pós-Operatórias/patologia , Aspergilose Pulmonar/tratamento farmacológico , Aspergilose Pulmonar/patologia , Triazóis/uso terapêutico
9.
J Cardiovasc Surg (Torino) ; 55(2 Suppl 1): 159-68, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24796909

RESUMO

For more than half a century ischemic spinal cord injury (SCI) and consecutively permanent paraplegia remained the most devastating complication after open and endovascular thoracoabdominal aortic aneurysm (TAAA) repair. Various neuroprotective strategies (e.g., motor-/somatosensory evoked potential monitoring and cerebrospinal fluid drainage) used as adjuncts have lowered the SCI; maybe most importantly, the modern collateral network (CN) has begun to replace the classic understanding of spinal cord blood supply implying several consequences. Reliable non-invasive tools to monitor cord perfusion to detect imminent spinal cord malperfusion, ischemia and forthcoming neurologic injury (particularly early postoperatively) is not available, neither is a reliable strategy to prevent ischemic injury during distal circulatory arrest and after segmental artery occlusion. Currently, two promising new concepts--potentially advancing spinal protection in open and endovascular TAAA repair--address these issues: 1) non-invasive real-time monitoring of the paraspinous CN-oxygenation via near-infrared spectroscopy (NIRS) as an alternative to the demanding direct neuromonitoring; and 2) preconditioning of the CN as minimally invasive, endovascular "first stage" to increase the resilience of spinal cord perfusion prior to definite aortic repair. This article illustrates both concepts discussing: 1) the clinical application of thoracic and lumbar collateral NIRS monitoring to indirectly detect spinal cord hypoperfusion; and 2) minimally invasive selective segmental artery coil-embolization (MISACE) for (arteriogenic) preconditioning of the CN prior to extensive open or endovascular staged TAAA repair.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Isquemia do Cordão Espinal/etiologia , Medula Espinal/irrigação sanguínea , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/fisiopatologia , Circulação Colateral , Embolização Terapêutica , Hemodinâmica , Humanos , Monitorização Intraoperatória/métodos , Paraplegia/diagnóstico , Paraplegia/etiologia , Paraplegia/prevenção & controle , Fluxo Sanguíneo Regional , Fatores de Risco , Espectroscopia de Luz Próxima ao Infravermelho , Isquemia do Cordão Espinal/diagnóstico , Isquemia do Cordão Espinal/prevenção & controle , Resultado do Tratamento
10.
Int J Obes (Lond) ; 38(8): 1061-7, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24166068

RESUMO

BACKGROUND: Bladder dysfunction has one of the highest prevalences as a comorbidity of obesity in industrialized countries. The aetiopathogenesis of obesity-associated bladder dysfunction is still obscure, but there is growing evidence that general metabolic changes in obese patients may be in part responsible. As demonstrated recently, high fat diet (HFD) significantly alters the protein expression in the urinary bladder, activates multiple signalling pathways associated with cell survival and inflammation and ultimately provokes bladder fibrosis in an obese rat model. The study aimed to elucidate the role of matrix metalloproteases (MMPs) and their specific tissue inhibitors of metalloproteases (TIMPs) in obesity-related bladder extracellular matrix (ECM) remodelling and the effect of weight loss surgery via sleeve gastrectomy (SG) on phenotype and molecular parameters. METHODS: Twenty-four male Sprague-Dawley rats were used for (i) characterization of the HFD phenotype and (ii) evaluation of alterations following SG. Metabolic status, the degree of bladder fibrosis and tissue expression and activity of MMP2, MMP9, MMP14, TIMP1 and TIMP2 were analysed by immunohistochemistry, enzyme-linked immunosorbent assay and activity assays. Statistical differences were calculated by analysis of variance or independent Student's t-test. A P-value <0.05 was considered statistically significant. RESULTS: In HFD rats, we found significant alterations in lipid metabolism, fat mass, free fatty acid profile, insulin resistance and inflammatory markers. Voided volume was significantly decreased, and bladder showed marked fibrosis. MMPs and TIMPs were differentially regulated depending on animal status (controls, chow diet, HFD, and SG- and sham-operated animals) in both urothelium and detrusor smooth muscle. Although animal weight and most metabolic parameters were positively affected by SG, bladder fibrosis persisted. The limitations of this study were 1 month follow-up and lack of direct measurement of bladder function. CONCLUSIONS: Early diagnosis of the bladder dysfunction associated with obesity is essential to allow targeted early intervention, that is, before manifestation of potentially irreversible ECM fibrotic alterations.


Assuntos
Dieta Hiperlipídica/efeitos adversos , Metaloproteinases da Matriz/metabolismo , Obesidade/metabolismo , Obesidade/cirurgia , Doenças da Bexiga Urinária/patologia , Bexiga Urinária/patologia , Redução de Peso , Animais , Cirurgia Bariátrica , Células Cultivadas , Modelos Animais de Doenças , Ensaio de Imunoadsorção Enzimática , Fibrose , Metabolismo dos Lipídeos , Masculino , Obesidade/complicações , Obesidade/enzimologia , Obesidade/patologia , Ratos , Ratos Sprague-Dawley , Doenças da Bexiga Urinária/enzimologia , Doenças da Bexiga Urinária/etiologia , Doenças da Bexiga Urinária/cirurgia
11.
Int J Comput Assist Radiol Surg ; 9(4): 617-33, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24170574

RESUMO

PURPOSE: A new approach to optimize stent graft selection for endovascular aortic repair is the use of finite element analysis. Once the finite element model is created and solved, a software module is needed to view the simulation results in the clinical work environment. A new tool for interpretation of simulation results, named Medical Postprocessor, that enables comparison of different stent graft configurations and products was designed, implemented and tested. METHODS: Aortic endovascular stent graft ring forces and sealing states in the vessel landing zone of three different configurations were provided in a surgical planning software using the Medical Imaging Interaction Tool Kit (MITK) software system. For data interpretation, software modules for 2D and 3D presentations were implemented. Ten surgeons evaluated the software features of the Medical Postprocessor. These surgeons performed usability tests and answered questionnaires based on their experience with the system. RESULTS: The Medical Postprocessor visualization system enabled vascular surgeons to determine the configuration with the highest overall fixation force in 16+/-6 s, best proximal sealing in 56+/-24s and highest proximal fixation force in 38+/- s. The majority considered the multiformat data provided helpful and found the Medical Postprocessor to be an efficient decision support system for stent graft selection. The evaluation of the user interface results in an ISONORM-conform user interface (113.5 points). CONCLUSION: The Medical Postprocessor visualization software tool for analyzing stent graft properties was evaluated by vascular surgeons. The results show that the software can assist the interpretation of simulation results to optimize stent graft configuration and sizing.


Assuntos
Aorta/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/métodos , Análise de Elementos Finitos , Processamento de Imagem Assistida por Computador/métodos , Software , Stents , Humanos , Resultado do Tratamento
12.
Radiologe ; 53(10): 886-95, 2013 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-24129987

RESUMO

Percutaneous transcatheter aortic valve implantation (TAVI) is an established alternative to open heart surgery in patients with severe aortic stenosis (AS) unsuitable for conventional aortic valve replacement due to comorbidities with a high perioperative risk or contraindications. Preprocedural imaging plays a major role for adequate determination of indications and prosthesis selection, prosthesis sizing and therefore for a reduction of periprocedural complications. Besides Doppler echocardiography which is mainly used for grading of the severity of aortic valve stenosis and peri-interventional imaging, cardiac computed tomography (CCT) is the imaging modality of choice. The CCT procedure not only allows for reliably assessment and measuring of the complex 3-dimensional geometry of the aortic root but also for the aorta and the peripheral vessels used as potential access paths.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Radiografia Intervencionista/métodos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Cuidados Pré-Operatórios/métodos , Prognóstico
13.
Eur J Vasc Endovasc Surg ; 46(6): 651-6, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24099957

RESUMO

OBJECTIVE: The aim of this study was to evaluate the feasibility of non-invasive monitoring of the paraspinous collateral network (CN) oxygenation prior to, during, and after thoracoabdominal aortic repair in a clinical series. METHODS: Near-infrared spectroscopy optodes were positioned bilaterally-over the thoracic and lumbar paraspinous vasculature-to transcutaneously monitor muscle oxygenation of the CN in 20 patients (age: 66 ± 10 years; men = 11) between September 2010 and April 2012; 15 had open thoracoabdominal aortic repair (Crawford II and III), three had thoracic endovascular aortic repair (TEVAR; Crawford I), and two had a hybrid repair (Crawford II). CN oxygenation was continuously recorded until 48 hours postoperatively. RESULTS: Hospital mortality was 5% (n = 1), 15% suffered ischemic spinal cord injury (SCI). Mean thoracic CN oxygenation saturation was 75.5 ± 8% prior to anesthesia (=baseline) without significant variations throughout the procedure (during non-pulsatile cooling on cardiopulmonary bypass and with aortic cross-clamping; range = 70.6-79.5%). Lumbar CN oxygenation (LbS) dropped significantly after proximal aortic cross-clamping to a minimum after 11.7 ± 4 minutes (74 ± 13% of baseline), but fully recovered after restoration of pulsatile flow to 98.5% of baseline. During TEVAR, stent-graft deployment did not significantly affect LbS. Three patients developed relevant SCI (paraplegia n = 1/paraparesis n = 2). In these patients LbS reduction after aortic cross-clamping was significantly lower compared with patients who did not experience SCI (p = .041). CONCLUSIONS: Non-invasive monitoring of CN oxygenation prior to, during, and after thoracoabdominal aortic repair is feasible. Lumbar CN oxygenation levels directly respond to compromise of aortic blood circulation.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Circulação Colateral , Isquemia/prevenção & controle , Monitorização Intraoperatória/métodos , Espectroscopia de Luz Próxima ao Infravermelho , Medula Espinal/irrigação sanguínea , Idoso , Aorta Abdominal/cirurgia , Aorta Torácica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Estudos de Viabilidade , Feminino , Mortalidade Hospitalar , Humanos , Isquemia/etiologia , Masculino , Músculo Esquelético/irrigação sanguínea , Paraplegia/etiologia , Paraplegia/prevenção & controle , Paresia/etiologia , Paresia/prevenção & controle , Projetos Piloto , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Stents
14.
Rofo ; 184(10): 941-9, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23999787

RESUMO

UNLABELLED: Transcatheter aortic valve implantation (TAVI) is currently considered an acceptable alternative for the treatment of patients with severe aortic stenosis and a high perioperative risk or a contraindication for open surgery. The benefit of TAVI significantly outweighs the risk of the procedure in patients requiring treatment that are not suitable for open surgery, and leads to a lower mortality in the one-year follow-up. The absence of a direct view of the aortic root and valve remains a challenge for the transcatheter approach. While direct inspection of the aortic valve during open surgery allows an adequate prosthesis choice, it is crucial for TAVI to know the individual anatomical details prior to the procedure in order to assure adequate planning of the procedure and proper prosthesis choice and patient selection. Among the imaging modalities available for the evaluation of patients prior to TAVI, computed tomography (CT) plays a central role in patient selection. CT reliably visualizes the dimensions of the aortic root and allows a proper choice of the prosthesis size. The morphology of the access path and relevant comorbidities can be assessed. The present review summarizes the current state of knowledge regarding the value of CT in the evaluation of patients prior to TAVI. KEY POINTS: CT plays a central role in patient selection and planning prior to TAVI. ▶ CT reliably detects the dimensions of the aortic root including the size of the aortic annulus, the degree of valve calcification and the morphology of the access routes. ▶ CT provides a more accurate measurement of the aortic annulus than 2D TEE and CT is the only imaging modality that allows a risk assessment for paravalvular leakages based on the calcification of the aortic valve.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Tomografia Computadorizada Multidetectores/métodos , Radiografia Intervencionista , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Humanos , Planejamento de Assistência ao Paciente , Seleção de Pacientes , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/prevenção & controle , Cuidados Pré-Operatórios , Desenho de Prótese , Ajuste de Prótese
15.
Thorac Cardiovasc Surg ; 61(8): 651-5, 2013 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-24072516

RESUMO

Current evolutions and substantial amendments of the German health care system in combination with distinguished progress in cardiac surgery over the past years require both a reflection of principles in patient-centered care and an update of basic standard requirements for a department of cardiac surgery in Germany. In due consideration of the data from the voluntary registry of the German Society for Thoracic and Cardiovascular Surgery, this article accurately defines core requirements for a cardiac surgical department (cardiac surgery on-site), subdivided into facilities, staff and processes. If based on these standards, one may anticipate that cardiac surgical care is performed under appropriate conditions leading to an intrinsic benefit for patients.


Assuntos
Procedimentos Cirúrgicos Cardíacos/normas , Serviço Hospitalar de Cardiologia/normas , Atenção à Saúde/normas , Avaliação de Processos e Resultados em Cuidados de Saúde/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Serviço Hospitalar de Cardiologia/organização & administração , Atenção à Saúde/organização & administração , Alemanha , Fidelidade a Diretrizes/normas , Pessoal de Saúde/normas , Humanos , Avaliação de Processos e Resultados em Cuidados de Saúde/organização & administração , Segurança do Paciente/normas , Guias de Prática Clínica como Assunto/normas , Garantia da Qualidade dos Cuidados de Saúde/organização & administração , Resultado do Tratamento
16.
Minerva Cardioangiol ; 61(1): 33-43, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23381378

RESUMO

Transcatheter aortic valve implantation (TAVI) is a new technology, which is rapidly growing to a routine procedure amenable for patients with symptomatic aortic valve stenosis and higher than average risk for conventional aortic valve surgery. The crucial disadvantage of TAVI remains the not well foreseeable risk of more than trivial degree of paravalvular leakage and a high rate of atrioventricular block and consecutive pacemaker implantation. In addition, current implantation techniques do not allow controlling the rotation of first-generation devices that might be beneficial regarding optimal physiological valve performance, optimal coronary flow and avoidance of placement of covered commissures in front of the coronary ostia. These shortcomings had pushed the development of second-generation self-expandable nitinol-based devices for subcoronary implantation that aim a reduction of paravalvular leak and AV-block by anatomical orientated positioning into the aortic root. This review focuses on the description of three different TAVI concepts, which are presently under early clinical evaluation, or have recently received commercial approval, using the transapical approach.


Assuntos
Valva Aórtica/cirurgia , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Valva Aórtica/anatomia & histologia , Desenho de Equipamento , Humanos
17.
Internist (Berl) ; 54(1): 18, 20-7, 2013 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-23318541

RESUMO

Unlike a few decades ago, today most patients with congenital heart disease reach adulthood after intervention or reparative surgery. As complete correction is generally not possible, a patient population with great complexity and a particular challenge to medical management is rising and a regular follow-up is mandatory. The aim of care is the timely recognition of residual or associated problems. Frequency and intensity of follow-up examinations depend on type and complexity of the lesion. The standard repertoire at follow-up consists of a specific history, clinical examination, ECG, Holter-monitoring, exercise tests, and echocardiography. Depending on the indication, cardio-MRI, CT scan, and sophisticated cardiac catheterization may become necessary. Long-term complications like rhythm disturbances, pulmonary hypertension, or heart failure are frequent, despite optimal care. Acute complications like arrhythmias, infective endocarditis, cerebral events, cerebral abscesses, aortic dissection, pulmonary embolism, and bleeding have to be recognized early and treated appropriately. Additional focus has to be placed on counseling and management of noncardiac disease and surgery, pregnancy and delivery, exercise at work and in private life, driving, and insurance issues. Training and certification of physicians as well as the establishment of specialized centers will help to ensure high quality health care for the affected patient population.


Assuntos
Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/reabilitação , Adulto , Cardiopatias Congênitas/terapia , Humanos , Medição de Risco
18.
Herz ; 38(1): 48-56, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22407425

RESUMO

OBJECTIVE: We performed a meta-analysis of randomized controlled trials to compare coronary artery bypass grafting (CABG) and percutaneous coronary intervention (PCI) for the treatment of de novo unprotected left main disease. BACKGROUND: Although CABG is accepted to be standard of care for revascularization of unprotected left main stenosis, PCI is increasingly being used as an alternative primary approach. METHODS: We searched for randomized, controlled trials comparing CABG and PCI for the treatment of unprotected left main disease. Major adverse cardiac and cerebrovascular events (all-cause death, myocardial infarction, stroke, and repeat revascularization) were analyzed. RESULTS: The search strategy identified 4 randomized controlled trials enrolling a total of 1,611 patients. Follow-up ranged between 1 and 2 years. There were no significant differences in the risk of death or myocardial infarction between the two treatment modalities. While the risk of stroke was significantly lower in patients undergoing PCI (risk ratio (RR) 0.26, 95% confidence interval (CI) 0.10-0.69, p = 0.007), the risk of repeat revascularization was higher among patients undergoing PCI (RR 1.94, 95% CI 1.43-2.61, p < 0.001). No relevant statistical heterogeneity across studies could be found. CONCLUSION: In this largest series of randomized patients with unprotected left main stenosis to date, the risk of death and myocardial infarction was comparable between CABG and PCI. However, patients undergoing CABG had a higher risk of stroke, whereas patients undergoing PCI were at a higher risk for repeat revascularization.


Assuntos
Ponte de Artéria Coronária/mortalidade , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea/mortalidade , Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Humanos , Prevalência , Fatores de Risco , Análise de Sobrevida , Taxa de Sobrevida , Resultado do Tratamento
19.
J Thorac Cardiovasc Surg ; 145(2): 425-9, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22365061

RESUMO

OBJECTIVE: The MiCardia DYANA annuloplasty system (MiCardia Corp, Irvine, Calif) is a nitinol-based dynamic complete ring that allows modification of the septal-lateral diameter under transesophageal echocardiography guidance in the loaded beating heart after mitral valve repair. Shape alteration is induced by radiofrequency via detachable activation wires. This multicenter study reports the first human experience with this device. METHODS: Patients (n = 35, 67 ± 8 years) with degenerative (n = 29), functional/ischemic (n = 5), or rheumatic (n = 1) mitral regurgitation underwent mitral valve repair using the new device. We analyzed the occurrence of death, endocarditis, ring dehiscence, systolic anterior motion, thromboembolism, pulmonary edema, heart block, ventricular arrhythmia, hemolysis, or myocardial infarction at 30 days (primary end point) and 6 months (secondary end point) postprocedure. RESULTS: All patients exhibited mitral regurgitation of 2 or less early postoperatively and at 6 months follow-up. In 29 patients, the initial mitral valve repair result was satisfactory and no ring activation was required. In 6 patients, the nitinol-based ring was deformed intraoperatively postrepair with further improvement of mitral regurgitation in all cases (preactivation: 0.9 ± 0.2, postactivation: 0.2 ± 0.3; P = .001). One death (2.9%, multisystem organ failure, non-device related), 2 ventricular arrhythmias (5.7%), and 1 heart block (2.9%) occurred, all in the first 30 days after surgery. No additional major adverse clinical events occurred later than 1 month postprocedure (total observed major adverse clinical event rate 11.5%). CONCLUSIONS: The implantation of the new dynamic annuloplasty ring allows for safe mitral valve repair. The option of postrepair modification of the septal-lateral diameter by radiofrequency may further optimize repair results.


Assuntos
Implante de Prótese de Valva Cardíaca , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral/cirurgia , Idoso , Ligas , Feminino , Alemanha , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Michigan , Pessoa de Meia-Idade , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/instrumentação , Anuloplastia da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/mortalidade , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento
20.
Rofo ; 185(10): 941-9, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24490256

RESUMO

UNLABELLED: Transcatheter aortic valve implantation (TAVI) is currently considered an acceptable alternative for the treatment of patients with severe aortic stenosis and a high perioperative risk or a contraindication for open surgery. The benefit of TAVI significantly outweighs the risk of the procedure in patients requiring treatment that are not suitable for open surgery, and leads to a lower mortality in the one-year follow-up. The absence of a direct view of the aortic root and valve remains a challenge for the transcatheter approach. While direct inspection of the aortic valve during open surgery allows an adequate prosthesis choice, it is crucial for TAVI to know the individual anatomical details prior to the procedure in order to assure adequate planning of the procedure and proper prosthesis choice and patient selection. Among the imaging modalities available for the evaluation of patients prior to TAVI, computed tomography (CT) plays a central role in patient selection. CT reliably visualizes the dimensions of the aortic root and allows a proper choice of the prosthesis size. The morphology of the access path and relevant comorbidities can be assessed. The present review summarizes the current state of knowledge regarding the value of CT in the evaluation of patients prior to TAVI. CT plays a central role in patient selection and planning prior to TAVI. CT reliably detects the dimensions of the aortic root including the size of the aortic annulus, the degree of valve calcification and the morphology of the access routes. KEY POINTS: CT plays a central role in patient selection and planning prior to TAVI. CT reliably detects the dimensions of the aortic root including the size of the aortic annulus, the degree of valve calcification and the morphology of the access routes. CT provides a more accurate measurement of the aortic annulus than 2D TEE and CT is the only imaging modality that allows a risk assessment for paravalvular leakages based on the calcification of the aortic valve.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Cuidados Pré-Operatórios/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/cirurgia , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Artéria Ilíaca/diagnóstico por imagem , Complicações Intraoperatórias/diagnóstico por imagem , Complicações Intraoperatórias/cirurgia , Masculino , Seleção de Pacientes , Desenho de Prótese , Ajuste de Prótese/métodos , Seio Aórtico/diagnóstico por imagem , Seio Aórtico/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA