Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
Heart Rhythm O2 ; 4(7): 448-456, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37520021

RESUMO

Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD) has demonstrated safety and efficacy for the treatment of malignant ventricular arrhythmias. However, a limitation of the S-ICD lies in the inability to either pace-terminate ventricular tachycardia or provide prolonged bradycardia pacing support. Objective: The rationale and design of a prospective, single-arm, multinational trial of an intercommunicative leadless pacing system integrated with the S-ICD will be presented. Methods: A technical description of the modular cardiac rhythm management (mCRM) system (EMPOWER leadless pacemaker and EMBLEM S-ICD) and the implantation procedure is provided. MODULAR ATP (Effectiveness of the EMPOWER™ Modular Pacing System and EMBLEM™ Subcutaneous ICD to Communicate Antitachycardia Pacing) is a multicenter, international trial enrolling up to 300 patients at risk of sudden cardiac death at up to 60 centers trial design. The safety endpoint of freedom from major complications related to the mCRM system or implantation procedure at 6 months and 2 years are significantly higher than 86% and 81%, respectively, and all-cause survival is significantly >85% at 2 years. Results: Efficacy endpoints are that at 6 months mCRM communication success is significantly higher than 88% and the percentage of subjects with low and stable thresholds is significantly higher than 80%. Substudies to evaluate rate-responsive features and performance of the pacing module are also described. Conclusion: The MODULAR ATP global clinical trial will prospectively test the safety and efficacy of the first intercommunicating leadless pacing system with the S-ICD. This trial will allow for robust validation of device-device communication, pacing performance, rate responsiveness, and system safety.

2.
JACC Clin Electrophysiol ; 8(11): 1431-1445, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36424012

RESUMO

BACKGROUND: Conduction system pacing (CSP) has emerged as an alternative to biventricular pacing (BiVP). Randomized studies comparing both therapies are scarce and do not include left bundle branch pacing. OBJECTIVES: This study aims to compare ventricular resynchronization achieved by CSP vs BiVP in patients with cardiac resynchronization therapy indication. METHODS: LEVEL-AT (Left Ventricular Activation Time Shortening with Conduction System Pacing vs Biventricular Resynchronization Therapy) was a randomized, parallel, controlled, noninferiority trial. Seventy patients with cardiac resynchronization therapy indication were randomized 1:1 to BiVP or CSP, and followed up for 6 months. Crossover was allowed when primary allocation procedure failed. Primary endpoint was the change in left ventricular activation time, measured using electrocardiographic imaging. Secondary endpoints were left ventricular reverse remodeling and the combined endpoint of heart failure hospitalization or death at 6-month follow-up. RESULTS: Thirty-five patients were allocated to each group. Eight (23%) patients crossed over from CSP to BiVP; 2 patients (6%) crossed over from BiVP to CSP. Electrocardiographic imaging could not be performed in 2 patients in each group. A similar decrease in left ventricular activation time was achieved by CSP and BiVP (-28 ± 26 ms vs -21 ± 20 ms, respectively; mean difference -6.8 ms; 95% CI: -18.3 ms to 4.6 ms; P < 0.001 for noninferiority). Both groups showed a similar change in left ventricular end-systolic volume (-37 ± 59 mL CSP vs -30 ± 41 mL BiVP; mean difference: -8 mL; 95% CI: -33 mL to 17 mL; P = 0.04 for noninferiority) and similar rates of mortality or heart failure hospitalizations (2.9% vs 11.4%, respectively) (P = 0.002 for noninferiority). CONCLUSIONS: Similar degrees of cardiac resynchronization, ventricular reverse remodeling, and clinical outcomes were attained by CSP as compared to BiVP. CSP could be a feasible alternative to BiVP. (LEVEL-AT [Left Ventricular Activation Time Shortening With Conduction System Pacing vs Biventricular Resynchronization Therapy]; NCT04054895).


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Sistema de Condução Cardíaco , Bloqueio de Ramo , Doença do Sistema de Condução Cardíaco/terapia , Remodelação Ventricular
3.
Heart Rhythm ; 19(12): 2115-2124, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36007727

RESUMO

BACKGROUND: Little is known about genome-wide changes in the atrial transcriptome as a cause or consequence of atrial fibrillation (AF), and the effect of its common and clinically relevant comorbidity-heart failure (HF). OBJECTIVE: The purpose of this study was to explore candidate disease processes for AF by investigating gene expression changes in atrial tissue samples from patients with and without AF, stratified by HF. METHODS: RNA sequencing was performed in right and left atrial appendage tissue in 195 patients undergoing open heart surgery from centers participating in the CATCH-ME consortium (no history of AF, n = 91; paroxysmal AF, n = 53; persistent/permanent AF, n = 51). Analyses were stratified into patients with/without HF (n = 75/120) and adjusted for age, sex, atrial side, and a combination of clinical characteristics. RESULTS: We identified 35 genes associated with persistent AF compared to patients without a history of AF, both in the presence or absence of HF (false discovery rate <0.05). These were mostly novel associations, including 13 long noncoding RNAs. Genes were involved in regulation of cardiomyocyte structure, conduction properties, fibrosis, inflammation, and endothelial dysfunction. Gene set enrichment analysis identified mainly inflammatory gene sets to be enriched in AF patients without HF, and gene sets involved in cellular respiration in AF patients with HF. CONCLUSION: Analysis of atrial gene expression profiles identified numerous novel genes associated with persistent AF, in the presence or absence of HF. Interestingly, no consistent transcriptional changes were associated with paroxysmal AF, suggesting that AF-induced changes in gene expression predominate other changes.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Humanos , Miócitos Cardíacos , Fibrose , Inflamação/genética , Inflamação/complicações
4.
Europace ; 22(9): 1391-1400, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32898254

RESUMO

AIMS: Sudden cardiac death (SCD) risk estimation in patients referred for cardiac resynchronization therapy (CRT) remains a challenge. By CRT-mediated improvement of left ventricular ejection fraction (LVEF), many patients loose indication for primary prevention implantable cardioverter-defibrillator (ICD). Increasing evidence shows the importance of myocardial scar for risk prediction. The aim of this study was to investigate the prognostic impact of myocardial scar depending on the echocardiographic response in patients undergoing CRT. METHODS AND RESULTS: Patients with indication for CRT were prospectively enrolled. Decision about ICD or pacemaker implantation was based on clinical criteria. All patients underwent delayed-enhancement cardiac magnetic resonance imaging. Median follow-up duration was 45 (24-75) months. Primary outcome was a composite of sustained ventricular arrhythmia, appropriate ICD therapy, or SCD. A total of 218 patients with LVEF 25.5 ± 6.6% were analysed [158 (73%) male, 64.9 ± 10.7 years]. Myocardial scar was observed in 73 patients with ischaemic cardiomyopathy (ICM) (95% of ICM patients); in 62 with non-ischaemic cardiomyopathy (45% of these patients); and in all but 1 of 36 (17%) patients who reached the primary outcome. Myocardial scar was the only significant predictor of primary outcome [odds ratio 27.7 (3.8-202.7)], independent of echocardiographic CRT response. A total of 55 (25%) patients died from any cause or received heart transplant. For overall survival, only a combination of the absence of myocardial scar with CRT response was associated with favourable outcome. CONCLUSION: Malignant arrhythmic events and SCD depend on the presence of myocardial scar but not on CRT response. All-cause mortality improved only with the combined absence of myocardial scar and CRT response.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Arritmias Cardíacas , Cicatriz/diagnóstico por imagem , Cicatriz/patologia , Morte Súbita Cardíaca/prevenção & controle , Insuficiência Cardíaca/terapia , Humanos , Masculino , Fatores de Risco , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
5.
Europace ; 22(10): 1480-1486, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32729896

RESUMO

AIMS: While the CLOSE protocol proposes a maximally tolerable interlesion distance (ILD) of 6 mm for ablation index ablation index-guided atrial fibrillation (AF) ablation, a target ILD has never been defined. This randomized study sought to establish a target ILD for ablation index-guided AF ablation. METHODS AND RESULTS: Consecutive patients scheduled for first-time pulmonary vein (PV) isolation (PVI) were randomly assigned to ablation protocols with a target ILD of 5.0-6.0 mm or 3.0-4.0 mm, with the primary endpoint of first-pass PVI. In compliance with the CLOSE protocol, the maximum tolerated ILD was 6.0 mm in both study protocols. A target ablation index of ≥550 (anterior) or ≥400 (posterior) was defined for the '5-6 mm' protocol and ≥500 (anterior) or ≥350 (posterior) for the '3-4 mm' protocol. The study was terminated early for superiority of the '3-4 mm' protocol. Forty-two consecutive patients were randomized and 84 ipsilateral PV pairs encircled according to the study protocol. First-pass PVI was accomplished in 35.0% of the '5-6 mm' group and 90.9% of the '3-4 mm' group (P < 0.0001). Median ILD was 5.2 mm in the '5-6 mm' group and 3.6 mm in the '3-4 mm' group (P < 0.0001). In line with the distinct ablation index targets, median ablation index was lower in the '3-4 mm' group (416 vs. 452, P < 0.0001). While mean procedure time was shorter in the '3-4 mm' group (149 ± 27 vs. 167 ± 33min, P = 0.004), fluoroscopy times did not differ significantly (4.7 ± 2.2 vs. 5.1 ± 1.8 min, P = 0.565). CONCLUSION: In ablation index-guided AF ablation, an ILD of 3.0-4.0 mm should be targeted rather than 5.0-6.0 mm. Moreover, the lower target ILD may allow for less extensive ablation at each given point.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Fluoroscopia , Humanos , Duração da Cirurgia , Veias Pulmonares/cirurgia , Resultado do Tratamento
6.
J Interv Cardiol ; 2020: 4386841, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32549801

RESUMO

BACKGROUND: Voltage mapping allows identifying the arrhythmogenic substrate during scar-related ventricular arrhythmia (VA) ablation procedures. Slow conducting channels (SCCs), defined by the presence of electrogram (EGM) signals with delayed components (EGM-DC), are responsible for sustaining VAs and constitute potential ablation targets. However, voltage mapping, as it is currently performed, is time-consuming, requiring a manual analysis of all EGMs to detect SCCs, and its accuracy is limited by electric far-field. We sought to evaluate an algorithm that automatically identifies EGM-DC, classifies mapping points, and creates new voltage maps, named "Slow Conducting Channel Maps" (SCC-Maps). METHODS: Retrospective analysis of electroanatomic maps (EAM) from 20 patients (10 ischemic, 10 with arrhythmogenic right ventricular dysplasia/cardiomyopathy) was performed. EAM voltage maps were acquired during sinus rhythm and used for ablation. Preprocedural contrast-enhanced cardiac magnetic resonance (Ce-CMR) imaging was available for the ischemic population. Three mapping modalities were analysed: (i) EAM voltage maps using standard (EAM standard) or manual (EAM screening) thresholds for defining core and border zones; (ii) SCC-Maps derived from the use of the novel SCC-Mapping algorithm that automatically identify EGM-DCs measuring the voltage of the local component; and (iii) Ce-CMR maps (when available). The ability of each mapping modality in identifying SCCs and their agreement was evaluated. RESULTS: SCC-Maps and EAM screening identified a greater number of SCC entrances than EAM standard (3.45 ± 1.61 and 2.95 ± 2.31, resp., vs. 1.05 ± 1.10; p < 0.01). SCC-Maps and EAM screening highly correlate with Ce-CMR maps in the ischemic population when compared to EAM standard (Lin's correlation = 0.628 and 0.679, resp., vs. 0.212, p < 0.01). CONCLUSION: The SCC-Mapping algorithm allows an operator-independent analysis of EGM signals showing better identification of the arrhythmogenic substrate characteristics when compared to standard voltage EAM.


Assuntos
Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Ablação por Cateter , Taquicardia Ventricular/etiologia , Adulto , Idoso , Arritmias Cardíacas/cirurgia , Displasia Arritmogênica Ventricular Direita/cirurgia , Cicatriz/patologia , Cicatriz/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico
7.
J Cardiovasc Electrophysiol ; 31(3): 638-646, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31957087

RESUMO

INTRODUCTION: Ablation with second-generation cryoballoon technology evolves as an effective and safe alternative to radiofrequency for atrial fibrillation ablation procedures. Nevertheless, the optimal freezing strategy remains unknown. Our objective was to identify the procedural cryoablation parameters predicting successful peri-pulmonary vein (PV) lesions by directly analyzing Postablation gaps in late-gadolinium-enhanced cardiac magnetic resonance (LGE-CMR). METHODS AND RESULTS: Forty-nine consecutive patients (196 PVs) undergoing ablation with second-generation cryoballoon at our center were included. The number and duration of cryoballoon application to achieve PV isolation were left to operator discretion. Gap number and length were quantified in all patients with a LGE-CMR performed 3 months postablation. Application time (420 ± 217 seconds), number of applications (2.1 ± 1.2), application time after electrical isolation (311 ± 194 seconds) and minimum temperature (-45.8 ± 6.5°C) were similar in the 4 PVs. Gaps were observed in 148 PVs (76%), averaging 1.3 ± 1 gaps per vein. Gaps were longer and more frequent in the right PVs (91% vs 59% in left PVs, P < .001). Neither the number, total duration of applications, nor postisolation application time predicted relative length or number of gaps. CONCLUSIONS: After successful PV isolation was achieved in patients undergoing cryoablation, increasing the number of applications, the total application time or application time postisolation did not result in a reduction in the number or the relative length of gaps.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia , Imageamento por Ressonância Magnética , Veias Pulmonares/cirurgia , Potenciais de Ação , Adulto , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Meios de Contraste/administração & dosagem , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Valor Preditivo dos Testes , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
8.
Europace ; 22(3): 382-387, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31821484

RESUMO

AIMS: Cryoballoon (CB) ablation has emerged as a reliable modality to isolate pulmonary veins (PVs) in atrial fibrillation. Ablation lesions and the long-term effects of energy delivery can be assessed by delayed-enhancement cardiac magnetic resonance (DE-CMR). The aim of the study was to compare the number, extension, and localization of gaps in CB and radiofrequency (RF) techniques in pulmonary vein isolation (PVI). METHODS AND RESULTS: Consecutive patients submitted to PVI with CB in whom DE-CMR images were available (n = 30) were matched (1:1) to patients who underwent PVI with RF (n = 30), considering age, sex, hypertension, and diabetes. Delayed-enhancement cardiac magnetic resonance was obtained at 3 months post-procedure, and images were processed to assess the mean number of gaps around PV ostia, their localization, and the normalized gap length (NGL), calculated as the difference between total gap length and total PV perimeter. Patients were followed up for 12 months. The CB and RF procedures did not differ in the mean number of gaps per patient (4.40 vs. 5.13 gaps, respectively; P = 0.21) nor NGL (0.35 vs. 0.32, P = 0.59). For both techniques, a higher mean number of gaps were detected in right vs. left PVs (3.18 vs. 1.58, respectively; P = 0.01). The incidence of recurrences did not differ between techniques (odds ratio 1.87, 95% confidence interval 0.66-4.97; P = 0.29). CONCLUSION: Location and extension of ablation gaps in PVI did not differ between CB and RF groups in DE-CMR image analysis.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos de Casos e Controles , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Humanos , Espectroscopia de Ressonância Magnética , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
9.
Am Heart J ; 220: 213-223, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31864099

RESUMO

BACKGROUND: Cardiogenic syncope in Brugada syndrome (BrS) increases the risk of major events. Nevertheless, clinical differentiation between cardiogenic and vasovagal syncope can be challenging. We characterized the long-term incidence of major events in a large cohort of BrS patients who presented with syncope. METHODS: From a total of 474 patients, syncope was the initial manifestation in 135 (28.5%) individuals (43.9 ±â€¯13.9 years, 71.1% male). The syncope was classified prospectively as cardiogenic, vasovagal, or undefined if unclear characteristics were present. Clinical, electrocardiographic, genetic, and electrophysiologic features were analyzed. Cardiogenic syncope, sustained ventricular arrhythmias, and sudden death were considered major events in follow-up. RESULTS: In 66 patients (48.9%), the syncope was cardiogenic; in 51 (37.8%), vasovagal and in 18 (13.3%); undefined. The electrophysiology study (EPS) inducibility was more frequent in patients with cardiogenic syncope and absent in all patients with undefined syncope (28 [53.8%] vs 5 [12.2%] vs 0 [0%]; P < .01). During follow-up (7.7 ±â€¯5.6 years), only patients with cardiogenic syncope presented major events (16 [11.9%]). Among patients with inducible EPS, 7 (21.2%) presented major events (P = .04). The negative predictive value of the EPS for major events was 92.4%. The incidence rate of major events was 2.6% person-year. Parameters associated with major events included cardiogenic syncope (hazard ratio [HR] 6.3; 95% CI 1.1-10.4; P = .05), spontaneous type 1 electrocardiogram (HR 3.7; 95% CI 1.3-10.5; P = .01), and inducible EPS (HR 2.8; 95% CI 1.1-8.8; P = .05). CONCLUSIONS: An accurate syncope classification is crucial in BrS patients for risk stratification. In patients with syncope of unclear characteristics, the EPS may be helpful to prevent unnecessary implantable cardioverter defibrillators.


Assuntos
Síndrome de Brugada/complicações , Síncope/etiologia , Adulto , Arritmias Cardíacas/etiologia , Síndrome de Brugada/fisiopatologia , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Valor Preditivo dos Testes , Prevalência , Síncope/classificação , Síncope/epidemiologia , Síncope/fisiopatologia , Síncope Vasovagal/epidemiologia , Síncope Vasovagal/etiologia , Síncope Vasovagal/fisiopatologia , Teste da Mesa Inclinada
11.
Sci Rep ; 9(1): 11443, 2019 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-31391506

RESUMO

Obstructive sleep apnea syndrome (OSA) promotes aortic dilatation, increased stiffness and accelerated atherosclerosis, but the mechanisms of vascular remodelling are not known. We aimed to assess vascular remodelling, its mechanisms, and the effect of mesenchymal stem cells (MSC) infusions in a clinically relevant rat model of chronic OSA involving recurrent airway obstructions leading thoracic pressure swings and intermittent hypoxia/hypercapnia (OSA-rats). Another group of rats were placed in the same setup without air obstructions (Sham-rats) and were considered controls. Our study demonstrates that chronic, non-invasive repetitive airway obstructions mimicking OSA promote remarkable structural changes of the descending thoracic aorta such as eccentric aortic hypertrophy due to an increased wall thickness and lumen diameter, an increase in the number of elastin fibers which, in contrast, get ruptured, but no changes in tunica media fibrosis. As putative molecular mechanisms of the OSA-induced vascular changes we identified an increase in reactive oxygen species and renin-angiotensin system markers and an imbalance in oxide nitric synthesis. Our results also indicate that MSC infusion blunts the OSA-related vascular changes, most probably due to their anti-inflammatory properties.


Assuntos
Aorta Torácica/fisiopatologia , Aterosclerose/terapia , Hipóxia/fisiopatologia , Transplante de Células-Tronco Mesenquimais , Apneia Obstrutiva do Sono/complicações , Animais , Aterosclerose/etiologia , Aterosclerose/fisiopatologia , Modelos Animais de Doenças , Humanos , Hipóxia/etiologia , Masculino , Ratos , Espécies Reativas de Oxigênio/metabolismo , Sistema Renina-Angiotensina/fisiologia , Apneia Obstrutiva do Sono/fisiopatologia , Remodelação Vascular/fisiologia , Rigidez Vascular/fisiologia
12.
PLoS One ; 14(6): e0217926, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31181097

RESUMO

BACKGROUND: AXL is a receptor tyrosine kinase that has been related to kidney and vascular disorders. Heart failure patients with reduced ejection fraction have higher AXL in serum than controls. No information about Axl expression with HF progression is available. METHODS: Thoracic transverse aortic constriction (TAC) was successfully performed on male Wistar rats (n = 25) with different constriction levels. Controls underwent sham surgery (n = 12). Echocardiography measurements were performed 4-8 weeks after surgery. Collagen deposition was measured with picrosirius red staining. Axl mRNA levels in left ventricle (LV), left kidney (LK) and ascending aorta (aAo) and the LV expression of cardiac remodeling and fibrogenic factors were quantified with real-time PCR. AXL LV protein levels were quantified with western blot and localization was analyzed by immunohistochemistry. Soluble AXL levels in plasma were assayed with ELISA. RESULTS: Successful TAC rats were classified into LV hypertrophy (LVH) or heart failure (HF), modeling the progressive cardiac changes after pressure overload. Collagen deposition was increased only in the HF group. LV Axl mRNA levels were higher in LVH and HF than in Sham rats, and correlated with LVHi, and hypertrophic and fibrogenic mediators. However, no association was found with LV systolic function. AXL was expressed in LV myocytes and other cell types. Concentration of circulating sAXL in plasma was increased in the LVH group compared to Sham and HF rats. Axl mRNA levels were similar in all groups in the LK and aAo. CONCLUSIONS: Axl expression pattern suggests a role in the early progression of LV remodeling in HF but not in the later systolic dysfunction. The higher levels of circulating AXL found in HF patients most probably shed from the heart.


Assuntos
Insuficiência Cardíaca/sangue , Receptores Proteína Tirosina Quinases/metabolismo , Remodelação Ventricular , Animais , Pressão Sanguínea , Progressão da Doença , Ecocardiografia , Hipertrofia Ventricular Esquerda , Masculino , Ratos , Ratos Wistar , Receptores Proteína Tirosina Quinases/sangue
13.
J Cardiovasc Electrophysiol ; 30(9): 1483-1490, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31115940

RESUMO

INTRODUCTION: Recurrences after atrial fibrillation (AF) ablation are still common. Among the reported clinical and imaging predictors of recurrences, diagnosis-to-ablation time (DAT) has been defined as a predictor of ablation outcome in single-center studies. We aimed to validate DAT in a multicenter real-life cohort. METHODS: This was a multicenter study including consecutive patients undergoing first paroxysmal and persistent AF ablation with radiofrequency or cryoballoon catheters during 2013. Cox proportional hazard regression models were performed to identify predictors of recurrence. RESULTS: In total, 309 patients were included across nine centers (71% men, 57 ± 10 years old, 46% with hypertension, and 66% with CHA2 DS2 -VASc ≤ 1). Most patients had paroxysmal AF (67%) and underwent radiofrequency ablation (68%) with a median DAT of 51 (43) months. Patients with DAT ≤ 1 year (16.6%) were less likely to have repeat procedures (4% vs 18%; P = .017). The adjusted proportional hazards Cox model identified hypertension (P = .005), heart failure (P = .011), nonparoxysmal AF (P = .038), DAT > 1 year (P = .007), and LA diameter (P = .026) as independent predictors for AF recurrence. DAT > 1 year was the only modifiable factor independently associated with recurrence (HR 4.2 [95% CI, 1.5-11.9]) CONCLUSION: Diagnosis-to-ablation time is a modifiable factor independently associated with recurrent arrhythmia and repeat ablation after first AF ablation. An early intervention strategy during the first year from AF diagnosis might improve outcomes.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Veias Pulmonares/cirurgia , Tempo para o Tratamento , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Medição de Risco , Fatores de Risco , Espanha , Fatores de Tempo , Resultado do Tratamento
15.
Europace ; 21(5): 746-753, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30715255

RESUMO

AIMS: Our objectives were to compare effectiveness and long-term prognosis after epicardial thoracoscopic atrial fibrillation (AF) ablation vs. endocardial catheter ablation, in patients with prior failed catheter ablation or high risk of failure. METHODS AND RESULTS: Patients were randomized to thoracoscopic or catheter ablation, consisting of pulmonary vein isolation with optional additional lines (2007-2010). Patients were reassessed in 2016/2017, and those without documented AF recurrence underwent 7-day ambulatory electrocardiography. The primary rhythm outcome was recurrence of any atrial arrhythmia lasting >30 s. The primary clinical endpoint was a composite of death, myocardial infarction, or cerebrovascular event, analysed with adjusted Cox proportional hazard ratios (HRs). One hundred and 24 patients were randomized with 34% persistent AF and mean age 56 years. Arrhythmia recurrence was common at mean follow-up of 7.0 years, but substantially lower with thoracoscopic ablation: 34/61 (56%) compared with 55/63 (87%) with catheter ablation [adjusted HR 0.40, 95% confidence interval (CI) 0.25-0.64; P < 0.001]. Additional ablation procedures were performed in 8 patients (13%) compared with 31 (49%), respectively (P < 0.001). Eleven patients (19%) were on anti-arrhythmic drugs at end of follow-up with thoracoscopy vs. 24 (39%) with catheter ablation (P = 0.012). There was no difference in the composite clinical outcome: 9 patients (15%) in the thoracoscopy arm vs. 10 patients (16%) with catheter ablation (HR 1.11, 95% CI 0.40-3.10; P = 0.84). Pacemaker implantation was required in 6 patients (10%) undergoing thoracoscopy and 3 (5%) in the catheter group (P = 0.27). CONCLUSION: Thoracoscopic AF ablation demonstrated more consistent maintenance of sinus rhythm than catheter ablation, with similar long-term clinical event rates.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Efeitos Adversos de Longa Duração , Recidiva , Cirurgia Torácica Vídeoassistida , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Eletrocardiografia Ambulatorial/métodos , Eletrocardiografia Ambulatorial/estatística & dados numéricos , Feminino , Seguimentos , Humanos , Efeitos Adversos de Longa Duração/epidemiologia , Efeitos Adversos de Longa Duração/terapia , Masculino , Pessoa de Meia-Idade , Mortalidade , Infarto do Miocárdio/epidemiologia , Avaliação de Processos e Resultados em Cuidados de Saúde , Acidente Vascular Cerebral/epidemiologia , Cirurgia Torácica Vídeoassistida/efeitos adversos , Cirurgia Torácica Vídeoassistida/métodos
16.
Europace ; 21(1): 7-8, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-29905786
18.
Expert Rev Cardiovasc Ther ; 17(1): 19-29, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30451034

RESUMO

Introduction: Regular endurance exercise over the course of many years appears to increase the risk of atrial fibrillation (AF). These data challenge the notion that the benefits of physical activity have no appreciable limits. The incidence of exercise-induced AF is expected to increase as a consequence of the popularity of extreme endurance sports. Actions to reduce its impact are warranted. Areas covered: This review focuses on exercise-induced AF and reviews the existing data regarding the prevention, screening, and treatment of this disease, with the aim of elucidating the best options for this group of patients. Expert commentary: To date, strategies to deal with exercise-induced AF are unsatisfactory. Improved knowledge of AF pathology and better classification schemes are needed to address current pitfalls.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Exercício Físico/fisiologia , Programas de Rastreamento/métodos , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Teste de Esforço , Humanos
19.
Int J Cardiol ; 275: 59-64, 2019 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-30314840

RESUMO

OBJECTIVES: The authors sought to evaluate cardiac activity of angiotensin-converting enzyme (ACE) and ACE2 after heart transplantation (HT) and its relation with acute rejection (AR) and chronic allograft vasculopathy (CAV). BACKGROUND: The renin-angiotensin system is altered in heart failure and HT. However, ACE and ACE2 activities in post-HT acute and chronic rejection have not been previously studied. METHODS: HT patients (n = 45) were included when appropriate serial endomyocardial biopsies (EMB) and coronary angiography were available for analysis. In 21 patients, three post-HT time points were selected for CAV study in EMB tissue: basal (0-3 wks), second (2-3 months) and third (4-5 months). At 10 years post-HT, CAV was evaluated by coronary angiography (CA) and patients were grouped by degree of CAV: 0-1, non-CAV (n = 15) and 2-3, CAV (n = 6). For the AR study, 28 HT patients with evidence of one EMB rejection at grade 3 and two EMB grade 1A and/or 1B rejections were selected. RESULTS: Post-HT, ACE2 activity was increased in the CAV group, compared to non-CAV. Patients with AR showed increased ACE, but not ACE2, activity. CONCLUSIONS: Our results suggest that early post-HT cardiac ACE2 activity may have an important role in CAV development. In contrast, ACE activity was increased in AR. The renin-angiotensin system seems to be altered after HT and strategies to balance the system may be useful.


Assuntos
Rejeição de Enxerto/enzimologia , Transplante de Coração/efeitos adversos , Miocárdio/enzimologia , Peptidil Dipeptidase A/metabolismo , Doença Aguda , Adulto , Enzima de Conversão de Angiotensina 2 , Biomarcadores/metabolismo , Biópsia , Doença Crônica , Angiografia Coronária , Feminino , Seguimentos , Rejeição de Enxerto/diagnóstico , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Projetos Piloto , Prognóstico , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Transplante Homólogo
20.
J Cardiovasc Electrophysiol ; 29(8): 1065-1072, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29722466

RESUMO

INTRODUCTION: The purpose of this study was to compare the anatomical characteristics of scar formation achieved by visual-guided laser balloon (Laser) and radiofrequency (RF) pulmonary vein isolation (PVI), using late-gadolinium-enhanced cardiac magnetic resonance imaging (LGE-CMR). METHODS AND RESULTS: We included 17 patients with paroxysmal or early persistent drug resistant AF who underwent Laser ablation; 2 were excluded due to procedure-related complications. The sample was matched with a historical group of 15 patients who underwent PVI using RF. LGE-CMR sequences were acquired before and 3 months post-PVI. Ablation gaps were defined as pulmonary vein (PV) perimeter sections showing no gadolinium enhancement. The number of ablation gaps was lower in Laser versus RF ablations (median 7 vs. 14, P  =  0.015). Complete anatomical PVI (circumferential scar around PV, without gaps) was more frequently achieved with Laser than with RF (39% vs. 19% of PVs, P  =  0.025). Fewer gaps were present at the superior and anterior left PV and posterior right PV antral regions in the Laser group, compared to RF. Scar extension into the PVs was similar in both groups, although RF produced more extensive ablation scar toward the LA body. AF recurrences at 1 year were similar in both groups (Laser 36% vs. RF 27%, P  =  1.00). CONCLUSIONS: Compared to RF, Laser ablation achieved more complete anatomical PVI, with less LA scar extension. However, AF recurrence appears to be similar after Laser compared to RF ablation. Further studies are needed to assess whether the anatomical advantages of Laser ablation translate into clinical benefit in patients with AF.


Assuntos
Gadolínio , Imagem Cinética por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Veias Pulmonares/diagnóstico por imagem , Ablação por Radiofrequência/tendências , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos de Coortes , Feminino , Seguimentos , Humanos , Terapia a Laser/efeitos adversos , Terapia a Laser/tendências , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Veias Pulmonares/cirurgia , Ablação por Radiofrequência/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA