Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur J Echocardiogr ; 9(3): 395-6, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-17337359

RESUMO

Prosthetic aortic valve endocarditis is associated with valve ring abscess, conduction abnormalities and a grave prognosis. Aortic root abscess is a serious complication of infective endocarditis with high mortality. We report a case of a patient who had echocardiographic features resembling aortic root abscess along with severe aortic regurgitation, 6 weeks following aortic valve replacement. Valvular dehiscence led to perivalvular abscess like appearance. Infective endocarditis was exluded. He underwent a successful redo aortic valve surgery with slow recovery.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Valva Aórtica , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Falha de Prótese , Abscesso/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Ponte de Artéria Coronária , Estenose Coronária/cirurgia , Diagnóstico Diferencial , Cardiopatias/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Ultrassonografia
2.
Clin Radiol ; 60(9): 990-8, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16124981

RESUMO

AIM: To compare the value of multislice computerized tomography (MSCT) in imaging coronary artery bypass grafts (CABGs) by direct quantitative comparison with standard invasive angiography. METHODS: Using MSCT, 50 consecutive patients who had previously undergone CABG surgery and had recently undergone invasive angiography for recurrent angina pectoris, were studied further using MSCT after intravenous injection of non-ionic contrast agent; cardiac imaging was performed during a single breath-hold. Graft anatomy was quantified, using both quantitative coronary angiography (QCA) and MSCT, by different investigators blinded to each other. Reproducibility was quantified using the standard error of the measurement expressed as a percentage in log-transformed values (CV%) and intraclass correlation (ICC). RESULTS: All 150 grafts were imaged using MSCT; only 4 patent grafts were not imaged using selective angiography. Good agreement was achieved between MSCT and QCA on assessment of proximal anastomoses (CV% 25.2, ICC 0.84), mid-vessel luminal diameter (CV% 15.5, ICC 0.91) and aneurysmal dilations (CV% 14.3). Reasonable agreement was reached on assessment of distal anastomoses (CV% 26.7, ICC 0.66) and categorization of distal run-off (ICC 0.73). Good agreement was observed for stenoses of over 50% luminal loss (CV% 8.7, ICC 0.97) but agreement on assessment of less severe lesions was poor (CV% 208.7, ICC 0.51). CONCLUSION: This study demonstrates that CABGs can be quantitatively evaluated using MSCT, and that significant lesions present in all CABG segments can be reliably identified. Agreement between MSCT and QCA for lesions of less than 50% luminal loss was poor.


Assuntos
Ponte de Artéria Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/cirurgia , Imageamento Tridimensional , Tomografia Computadorizada por Raios X/métodos , Idoso , Angiografia Coronária/métodos , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA