Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Front Cardiovasc Med ; 9: 842532, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35387440

RESUMO

Objective: To evaluate the prognostic impact of the parameters of myocardial deformation using three-dimensional speckle tracking echocardiography (3DSTE) in patients with breast cancer who underwent chemotherapy with low doses of anthracyclines. Background: Chemotherapy-related cardiotoxicity has an important prognostic impact on cancer survivors. Three-dimensional STE has revealed more consistent data than two-dimensional techniques and may represent a more accurate tool in the evaluation of myocardial function in patients who underwent chemotherapy. Methods: We evaluated patients with breast cancer who were treated with anthracyclines (associated or not with trastuzumab) in five stages: baseline, after cumulative doses of 120 and 240 mg/m2 of doxorubicin, and then, after 6 months and at least 1 year after anthracyclines. Ultrasensitive troponin I (US-TnI) and a standard echocardiography study were performed at each stage. We analyzed left ventricular ejection fraction (LVEF) by Simpson's method, two-dimensional speckle tracking (2DSTE) with longitudinal and radial strain values, and 3DSTE with longitudinal, radial, and circumferential strain as well as twist, torsion, rotation, and three-dimensional global area strain (3DGAS). Cardiotoxicity was defined as a decrease in LVEF by more than 10 percentage points to a value lower than 53%. Results: We evaluated 51 female patients who were aged 50.6 ± 11 years. After the cumulative dose of 240 mg/m2 of doxorubicin, US-TnI was increased (>34 pg/ml) in 21 patients (45%, p > 0.001), LVEF remained unchanged (p = 0.178), while 2DSTE longitudinal strain was decreased (from -17.8% to -17.1%, p < 0.001) and 3DSTE detected changes in longitudinal, radial, circumferential, and area strain. After a lower cumulative dose of doxorubicin (120 mg/m2), 3DGAS (p < 0.001) was the only parameter that was changed. In the follow-up, 7 (13%) patients presented a decrease in LVEF. Three-dimensional GAS early changed to abnormal values was the only variable associated with a subsequent decrease in LVEF (definitive cardiotoxicity). Conclusion: In patients with breast cancer, 3DSTE detected early changes in area strain after very low doses of doxorubicin. The 3DGAS early changed to abnormal values was associated with a subsequent decrease in LVEF, representing a promising technique to predict chemotherapy-induced cardiomyopathy.

3.
ABC., imagem cardiovasc ; 30(3): f:92-l:97, jul.-set. 2017. tab, ilus
Artigo em Português | LILACS | ID: biblio-848728

RESUMO

Introdução: A ecocardiografia é fundamental na distinção entre adaptações fisiológicas promovidas pela atividade física e alterações patológicas. O ecocardiograma tridimensional com speckle tracking (3DSTeco) poderia mostrar-se acurado para a detecção de alterações subclínicas da função cardíaca. Objetivos: Determinar o efeito do exercício nos parâmetros da deformação miocárdica em atletas, por meio do 3DSTeco. Método: Realizado ecocardiograma convencional, ecocardiograma tridimensional (3Deco) e 3DSTeco em boxeadores de elite, para análise dos volumes do ventrículo esquerdo (VE), índice de massa indexada à superfície corpórea (IMISC), fração de ejeção (FE), strain global longitudinal (GLS), strain global circunferencial (GCS), strain global radial (GRS), twist, torção e área tracking. Estes dados foram comparados com medidas efetuadas em indivíduos controle não treinados. Resultados: Analisados 16 atletas e 14 controles, com idade (23 ± 4 vs 21 ± 4 anos; p = NS) e sexo (14 vs 12 homens) similares. A FE do VE foi normal e semelhante nos 2 grupos. O IMISC foi maior nos atletas (83 ± 21 vs 65 ± 15 g/m²; p < 0,05), assim como o GRS (24,7 ± 5.2 vs 16.3 ± 7.2; p = 0.007). Não houve diferença significativa para os demais parâmetros como GCS (-26 ± 2 vs -28 ± 6), GLS (-16 ± 2 vs -17 ± 3), twist (3.1 ± 1.3 vs 3.7 ± 1.9), torção (2.0 ± 0.8 vs 1.4 ± 0.4) e área tracking (37 ± 4 vs 41 ± 6). Conclusão: Atletas e indivíduos não treinados apresentam parâmetros de deformação miocárdica comparáveis pelo 3DSTeco, contudo, um incremento do GRS foi observado apenas nos atletas. O 3DSTeco poderia auxiliar na detecção precoce de alterações cardíacas subclínicas em atletas


Introduction: Echocardiography is fundamental in the distinction between physiological adaptations promoted by physical activity and pathological abnormalities. Three-dimensional speckle tracking echocardiography (3D-STE) could prove accurate in detecting subclinical abnormalities in cardiac function. Objectives: To determine the effect of exercise on the parameters of myocardial strain in athletes through 3D STE. Method: Elite boxers underwent conventional three-dimensional echocardiography (3D-echo) and 3D-STE to analyze left ventricular (LV) volumes, left ventricular mass indexed to body surface area (LVMIBSA), ejection fraction (EF), longitudinal global strain (LGS), circumferential global strain (CGS), radial global strain (RGS), twist, torsion and tracking area. These data were compared with measurements performed on untrained control individuals. Results: The analyses included 16 athletes and 14 controls with similar age (23 ± 4 vs. 21 ± 4 years; p = NS) and gender (14 vs. 12 males). LVEF was normal and similar in the 2 groups. LVMIBSA was higher in the athletes (83 ± 21 vs. 65 ± 15 g/m², p < 0.05), as well as RGS (24.7 ± 5.2 vs. 16.3 ± 7.2; p = 0.007). There was no significant difference for the other parameters, such as CGS (-26 ± 2 vs. -28 ± 6), LGS (-16 ± 2 vs. -17 ± 3), twist (3.1 ± 1.3 vs. 3.7 ± 1.9), torsion (2.0 ± 0.8 vs. 1.4 ± 0.4) and tracking area (37 ± 4 vs. 41 ± 6). Conclusion: Athletes and untrained individuals have comparable myocardial strain parameters on 3D-STE. However, an increase in RGS was observed only in the athletes. 3D-STE could help in the early detection of subclinical cardiac issues in athletes


Assuntos
Humanos , Masculino , Feminino , Adulto , Atletas , Ecocardiografia Tridimensional/métodos , Coração/diagnóstico por imagem , Padrões de Referência/análise , Cardiomiopatias/diagnóstico , Doenças Cardiovasculares/diagnóstico , Estudos Transversais , Diagnóstico por Imagem/métodos , Ecocardiografia/métodos , Exercício Físico , Fatores de Risco , Interpretação Estatística de Dados , Função Ventricular Esquerda
4.
Echocardiography ; 33(3): 472-5, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26660848

RESUMO

Rupture of tricuspid valve is unusual, occurring mainly in the setting of blunt trauma or endomyocardial biopsy. Spontaneous tricuspid valve chordal rupture is particularly rare. We report herein a case of a patient with severe pulmonary hypertension, on the lung transplantation waiting list, who presented with spontaneous chordal rupture, exacerbation of tricuspid insufficiency and worsening of clinical status. Diagnosis and treatment, along with possible mechanisms for this complication, are discussed.


Assuntos
Hipertensão Pulmonar Primária Familiar/diagnóstico por imagem , Hipertensão Pulmonar Primária Familiar/terapia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/lesões , Adulto , Diagnóstico Diferencial , Ecocardiografia/métodos , Hipertensão Pulmonar Primária Familiar/complicações , Evolução Fatal , Feminino , Humanos , Ruptura , Ruptura Espontânea/diagnóstico por imagem , Ruptura Espontânea/etiologia , Ruptura Espontânea/cirurgia , Resultado do Tratamento , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/etiologia
5.
Clin Exp Rheumatol ; 32(5): 754-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25152021

RESUMO

OBJECTIVES: This paper aims to perform global assessment of long-term cardiac function in juvenile idiopathic arthritis (JIA) patients under TNF blockage therapy. METHODS: Twenty-five polyarticular-course JIA patients pre-anti-TNF and 22 healthy controls underwent conventional/tissue Doppler echocardiography and cardiac biomarkers measurements (N-terminal pro-brain natriuretic peptide [NT-pro-BNP] and troponin T) at baseline (BL). Twenty-one JIA patients completed six evaluations during two consecutive years. Clinical/laboratorial evaluations were assessed before and during TNF blockage therapy. RESULTS: JIA patients and controls were comparable regarding current age (p=0.898) and female gender (p=0.38). At BL isovolumetric relaxation time of left ventricle (p=0.03), ventricular septum (VS), E' wave (p=0.014) and VS S wave velocity (p=0.03) were significantly reduced in JIA patients compared to controls. Frequencies of elevated NT-pro-BNP and troponin T levels were similar in JIA and controls (p=0.297 and p=0.756) and levels remained within normal range throughout the study, except for one patient with mild troponin T elevation. During TNF blockage therapy, none of the 21 participants had heart failure, ejection fraction or other parameters alterations in conventional and tissue Doppler. Only one had mild pulmonary hypertension. Further analysis revealed that JIA patients with elevated levels of NT-pro-BNP at BL had significantly more active joints (p=0.025) and higher ESR (p=0.034). CONCLUSIONS: Long-term TNF blockage safety was demonstrated in JIA patients in spite of the observed subclinical diastolic involvement. Elevated cardiac biomarker in these patients was associated with inflammatory parameters reinforcing the need for a careful interpretation of this finding in patients with active disease.


Assuntos
Anti-Inflamatórios/uso terapêutico , Artrite Juvenil/tratamento farmacológico , Cardiopatias/etiologia , Fator de Necrose Tumoral alfa/antagonistas & inibidores , Adolescente , Anti-Inflamatórios/efeitos adversos , Artrite Juvenil/complicações , Artrite Juvenil/diagnóstico , Artrite Juvenil/imunologia , Biomarcadores/sangue , Estudos de Casos e Controles , Criança , Pré-Escolar , Ecocardiografia Doppler , Feminino , Cardiopatias/sangue , Cardiopatias/diagnóstico , Cardiopatias/fisiopatologia , Humanos , Masculino , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Troponina T/sangue , Fator de Necrose Tumoral alfa/metabolismo , Função Ventricular Esquerda/efeitos dos fármacos
6.
Cardiol Young ; 24(2): 229-35, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23458163

RESUMO

Mucopolysaccharidosis type VI (Marateaux-Lamy syndrome) is an autosomal recessive disorder caused by deficient activity of the enzyme N-acetylgalactosamine-4-sulphatase (arylsulphatase B). Cytoplasmic vacuoles full of dermatan sulphate are observed in endothelial cells, myocyte, and fibroblasts, compromising the function of cardiovascular structures and contributing significantly towards morbidity and mortality. The primary objective of this study was to assess the advantages of early replacement therapy with recombinant human arylsulphatase B through the echocardiographic follow-up of sisters who started treatment at quite different ages: one at 9 years and the other at 1 year and 7 months. The older sibling showed striking mitral and aortic valve compromise when she was only 2 years old and finally needed cardiac surgery at the age of 8, even before starting enzyme replacement. Differently, the younger one has developed only mild mitral and aortic lesions throughout the follow-up period of 3 years. The two siblings had left ventricle cardiomyopathy, but partial reverse remodelling was induced by enzyme replacement therapy in both cases. The younger sibling has never received any cardiovascular drugs, whereas the older one has been using ß-blockers and diuretics in addition to enzyme therapy to cope with heart failure. Comparing the outcomes of these two sisters with a very aggressive phenotype of mucopolysaccharidosis type VI, the conclusion was that early onset of therapy may slow down the disease progression and prevent severe cardiac lesions to be established. Moreover, patients' compliance is essential for the success of treatment, as sequential echocardiographic evaluation demonstrated worsening of some cardiac lesions whenever infusions were missed.


Assuntos
Insuficiência da Valva Aórtica/tratamento farmacológico , Cardiomiopatias/tratamento farmacológico , Intervenção Médica Precoce , Terapia de Reposição de Enzimas , Insuficiência da Valva Mitral/tratamento farmacológico , Mucopolissacaridose VI/tratamento farmacológico , N-Acetilgalactosamina-4-Sulfatase/uso terapêutico , Proteínas Recombinantes/uso terapêutico , Irmãos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/etiologia , Estudos de Casos e Controles , Criança , Ecocardiografia , Feminino , Seguimentos , Humanos , Lactente , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Mucopolissacaridose VI/complicações , Mucopolissacaridose VI/diagnóstico por imagem , Remodelação Ventricular
10.
Rev. bras. ecocardiogr. imagem cardiovasc ; 24(1): 103-106, jan.-mar. 2011. ilus
Artigo em Português | LILACS | ID: lil-571192

RESUMO

Classicamente, a cardiomiopatia de Takotsubo caracteriza-se por alteração transitória da contratilidade regional envolvendo o ápex e os segmentos médios do ventrículo esquerdo, com segmentos basais hipercontráteis, na ausência de doença coronária obstrutiva. Recentemente, casos de disfunção regional do ventrículo esquerdo induzidos pelo estresse, com padrões alternativos de disfunção regional em que o ápex é geralmente poupado (Takotsubo Invertido), têm sido relatados. Neste relato é descrito um caso de miocardiopatia induzida pelo estresse, no qual alterações da contratilidade segmentar foram observadas somente nos segmentos médios dos ventrículos, formando uma região acinética em faixa em torno do coração.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Abdome/cirurgia , Cardiomiopatia de Takotsubo/complicações , Cardiomiopatia de Takotsubo/diagnóstico , Disfunção Ventricular Esquerda/complicações , Laparotomia
11.
Arq. bras. cardiol ; 92(4): 294-301, abr. 2009. ilus, graf, tab
Artigo em Português, Inglês, Espanhol | LILACS | ID: lil-517301

RESUMO

FUNDAMENTO: O ecocardiograma tridimensional em tempo real (ECO 3D) e a tomografia computadorizada ultra-rápida (CT) são dois novos métodos de análise da fração de ejeção e dos volumes do VE. OBJETIVO: Comparar as medidas da FEVE e dos volumes do VE aferidos pelo ECO 3D e pela CT ultra-rápida. MÉTODOS: Foram estudados pelo ECO 3D e pela CT ultra-rápida de 64 cortes, 39 pacientes consecutivos (27 homens, média etária de 57±12 anos). Foram analisados: FEVE e volumes do VE. Análise estatística: coeficiente de correlação (r: Pearson), teste de Bland & Altman, teste de regressão linear, 95 por cento IC, p<0,05. RESULTADOS: Medidas do ECO 3D: a FEVE variou de 56,1 a 78,6 (65,5±5,58) por cento; volume diastólico final variou de 49,6 a 178,2 (87±27,8)ml; volume sistólico final variou de 11,4 a 78 (33,1±13,6)ml. Medidas da CT: a FEVE variou de 53 a 86 (67,8±7,78) por cento; volume diastólico final variou de 51 a 186 (106,5±30,3) ml; volume sistólico final variou de 7 a 72 (35,5±13,4)ml. As correlações entre ECO 3D e CT foram: FEVE (r: 0,7888, p<0,0001, 95 por cento IC 0,6301 a 0,8843); volume diastólico final (r: 0,7695, p<0,0001, 95 por cento IC 0,5995 a 0,8730); volume sistólico final (r: 0,8119, p<0,0001, 95 por cento IC 0,6673 a 0,8975). CONCLUSÃO: Nesta série, foi observada boa correlação entre as medidas da FEVE e entre os volumes ventriculares aferidos pelo ECO3D e pela CT ultra-rápida de 64 cortes.


BACKGROUND: Real-time three-dimensional echocargiography (RT-3D-Echo) and ultrafast computed tomography (CT) are two novel methods for the analysis of LV ejection fraction and volumes. OBJECTIVE: To compare LVEF and volume measurements as obtained using RT-3D-Echo and ultrafast CT. METHODS: Thirty nine consecutive patients (27 men, mean age of 57±12 years) were studied using RT-3D-Echo and 64-slice ultrafast CT. LVEF and LV volumes were analyzed. Statistical analysis: coefficient of correlation (r: Pearson), Bland-Altman analysis, linear regression analysis, 95 percent CI, p<0.05. RESULTS: RT-3D-Echo measurements: LVEF ranged from 56.1 to 78.6 (65.5±5.58) percent; end-diastolic volume ranged from 49.6 to 178.2 (87±27.8) ml; end-systolic volume ranged from 11.4 to 78 (33.1±13.6) ml. CT scan measurements: LVEF ranged from 53 to 86 percent (67.8±7.78); end-diastolic volume ranged from 51 to 186 (106.5±30.3) ml; end-systolic volume ranged from 7 to 72 (35.5±13.4)ml. Correlations between RT-3D-Echo and CT were: LVEF (r: 0.7888, p<0.0001, 95 percent CI 0.6301 to 0.8843); end-diastolic volume (r: 0.7695, p<0.0001, 95 percent CI 0.5995 to 0.8730); end-systolic volume (r: 0.8119, p<0.0001, 95 percent CI 0.6673 to 0.8975). CONCLUSION: Good correlation between LVEF and ventricular volume parameters as measured by RT-3D-Echo and 64-slice ultrafast CT was found in the present case series.


FUNDAMENTO: La ecocardiografía tridimensional en tiempo real (Eco-3DTR) y la tomografía computarizada ultrarrápida (TC ultrarrápida) son dos nuevos métodos de análisis de la fracción de eyección (FE) y de los volúmenes del ventrículo izquierdo (VI). OBJETIVO: Comparar las mediciones de la fracción de eyección del ventrículo izquierdo (FEVI) y de los volúmenes del VI apurados por la Eco-3DTR y por la TC ultrarrápida. MÉTODOS: Se estudiaron, mediante la Eco-3DTR y la TC ultrarrápida de 64 cortes, a 39 pacientes consecutivos (27 varones, promedio de edad de 57±12 años). Se analizaron: FEVI y volúmenes del VI. Análisis estadístico: coeficiente de correlación (r: Pearson), prueba de Bland & Altman, prueba de regresión lineal, 95 por ciento IC, p<0,05. RESULTADOS: Valores de la Eco-3DTR: variación de la FEVI de 56,1 a 78,6 (65,5±5,58) por ciento; variación del volumen diastólico final de 49,6 a 178,2 (87±27,8)mL; variación del volumen sistólico final de 11,4 a 78 (33,1±13,6)mL. Valores de la TC ultrarrápida: variación de la FEVI de 53 a 86 (67,8±7,78) por ciento; variación del volumen diastólico final de 51 a 186 (106,5±30,3) mL; variación del volumen sistólico final de 7 a 72 (35,5±13,4) mL. Las correlaciones entre la Eco-3DTR y la TC ultrarrápida fueron: FEVI (r: 0,7888, p<0,0001, 95 por ciento IC 0,6301 a 0,8843); volumen diastólico final (r: 0,7695, p<0,0001, 95 por ciento IC 0,5995 a 0,8730); volumen sistólico final (r: 0,8119, p<0,0001, 95 por ciento IC 0,6673 a 0,8975). CONCLUSIÓN: En esta serie, se observó una buena correlación entre las mediciones de la FEVI y entre los volúmenes ventriculares apurados por la Eco-3DTR y por la TC ultrarrápida de 64 cortes.


Assuntos
Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença da Artéria Coronariana , Volume Cardíaco/fisiologia , Ecocardiografia Tridimensional/métodos , Volume Sistólico/fisiologia , Tomografia Computadorizada por Raios X/métodos , Função Ventricular Esquerda/fisiologia , Doença da Artéria Coronariana , Doença da Artéria Coronariana , Métodos Epidemiológicos
12.
Rev. bras. ecocardiogr ; 21(4): 23-29, out.-nov. 2008. ilus, tab, graf
Artigo em Português | LILACS | ID: lil-497519

RESUMO

Fundamento e objetivo: O ecocardiograma tridimensional (ECO 3D) e a tomografia computadorizada ultra-rápida (CT) constituem 2 novos métodos de análise da fração de ejeção e dos volumes do ventrículo esquerdo (VE). Existem poucos estudos dirigidos à comparação da análise da fração de ejeção do VE aferidos por ambos os métodos. O objetivo deste estudo foi comparar as medidas da FEVE e dos volumes do VE ECO 3D em tempo real e pela CT ultra rápida. Método: Foram estudados pelo ECO 3D e pela CT ultra rápida de 64 cortes, 41 pacientes (29 homens, média etária de 58 + - 111 anos). Foram analisados com ambas as técnicas: FEVE, volumes sistólico final e diastólico final do VE. Os parâmetros aferidos com o ECO3D e com a CT foram comparados com o emprego do coeficiente de determinação (r:Pearson), do teste de Bland & Altman e do teste de regressão linear, 95 por cento IC, p<0,05. Resultados: Medidas do ECO 3D: a FEVE variou de 56,7 a 78,9 (65,3 + - 5,7) por cento; volume diastólico final variou de 49,6 a 178,2 (88+ - 27,5) mL; volume sistólico final variou de 11,4 a 78 (33,9 + - 13,7) mL. Medidas da CT: a FEVE variou de 7 a 72 (35,1 + - 13,8) mL. As correlações entre ECO 3D e CT foram: FEVE (r: 0,7877, p>0,0001, 95 por cento IC 0,6327 a 0,8853); volume diastólico final (r:0,7671, p< 0,0001, 95 por cento IC 0,5974 a 0,8745); volume sistólico final (r: 0,8121, p< 0,0001, 95 por cento IC 0,6659 a 0,8957). Conclusão: Foi evidenciada boa correlação entre as medidas da FEVE e entre os volumes ventriculares aferidos pelo ECO3D em tempo real e pela CT ultra rápida de 64 cortes.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Coração/anatomia & histologia , Volume Sistólico/fisiologia , Estudo Comparativo , Ecocardiografia Tridimensional/métodos , Ecocardiografia Tridimensional , Tomografia/métodos , Tomografia
13.
Rev. bras. ecocardiogr ; 21(4): 39-44, out.-nov. 2008. ilus, tab, graf
Artigo em Português | LILACS | ID: lil-497521

RESUMO

Fundamento e Objetivo: A sincronia do ventrículo esquerdo (VE) tem importância para a performance sistólica ventricular. O objetivo desde estudo foi comparar a sincronia do VE analisada com ecocardiograma (eco) tridimensional(3D) em tempo real, com medidas de FEVE, obtidas com ECO bidimensional (2D) e 3D. Métodos: Estudo prospectivo de 82 indivíduos (46 homens, 48 + - 12 anos), sendo 50 com anatomia cardíaca (eco) e ECG normais (grupo N) e 32 pacientes portadores de cardiomiopatia dilatada (grupo CMD). Foram medidos com o ECO 3D: FEVE, volumes e o índice de dissincronia (DI) por cento para 16 segmentos do VE. Com o ECO 2D foram aferidos: FEVE (método de Simpson) e volumes. Os dados foram comprados: com a mensuração do coeficiente de correlação (Pearson), 95 por cento IC, com o teste de regressão linear e teste de Bland & Altman, p>0,05. Resultados: O DI por cento variou de 0,28 a 28,1 (5,23 + 6,72), a FEVE 3D variou de 0,17 a 0,78 (0,51 + 0,14); a FECE 2D variou de 0,3 a 0,71 (0,46 + 0,15). A correlação entre DI e FEVE 3D foi (r): -0,7272, p> 0,0001, IC: -0,8328 a -0,6257, a relação linear entre DI (x) e FEVE 3D (y) foi y 17,6163 + ( -24,9872) x, p<0,0001. A correlação entre DI e FEVE...


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Coração/anatomia & histologia , Função Ventricular Esquerda/fisiologia , Volume Sistólico/fisiologia , Ecocardiografia Tridimensional/métodos , Ecocardiografia Tridimensional , Estudos Prospectivos , Sístole/fisiologia
14.
Rev. bras. ecocardiogr ; 21(4): 50-55, out.-nov. 2008. ilus
Artigo em Português | LILACS | ID: lil-497523

RESUMO

Na biomedicina, o estudo experimental tem papel estabelecido na aquisição de novas tecnologias. Cada vez mais, o laboratório de ecocardiografia tem aplicado a experimentação animal para incorporar novos programas, analisar a segurança biológica dos meios de contraste e validar téncinas cirúrgicas cardiovasculares. O objetivo deste artigo é abordar as diversas etapas de elaboração do estudo experimental, legislação, normatização e comentar alguns experimentais envolvendo a ecocardiografia.


Assuntos
Animais , Epidemiologia/normas , Experimentação Animal/ética , Experimentação Animal/legislação & jurisprudência , Ecocardiografia/normas
15.
Arq. bras. cardiol ; 91(3): 156-162, set. 2008. ilus, graf, tab
Artigo em Português, Inglês | LILACS | ID: lil-494310

RESUMO

FUNDAMENTO: O acoplamento eletromecânico (sincronia) do ventrículo esquerdo (VE) tem importância na análise da performance sistólica, especialmente para a indicação da terapia de ressincronização cardíaca em pacientes com ICC avançada. OBJETIVO: Comparar a sincronia do VE analisada com ecocardiograma (eco) tridimensional (3D) em tempo real com medidas de FEVE obtidas com ECO 2D e 3D. MÉTODOS: Estudo prospectivo de 92 indivíduos (56 homens, 47±10 anos), 60 com anatomia cardíaca (eco) e ECG normais (Grupo N), 32 com cardiomiopatia dilatada (Grupo CMD). Com o emprego do ECO 3D foram aferidos FEVE, volumes e índice de dissincronia (ID) por cento para 16 segmentos do VE; com o ECO 2D foram medidos FEVE (método de Simpson) e volumes sistólico e diastólico do VE. Análise estatística: coeficiente de correlação (Pearson), 95 por cento IC, teste de regressão linear, teste de Bland & Altman, p<0,05. RESULTADOS: O ID por cento variou de 0,2900 a 28,1000 (5,2014±6,3281), a FEVE 3D variou de 0,17 a 0,81 (0,52±0,17); a FEVE 2D variou de 0,3 a 0,69 (0,49±0,11). A correlação entre ID e FEVE 3D foi (r): -0,7432, p<0,0001, IC: -0,8227 a -0,6350, a relação linear entre ID (x) e FEVE 3D (y) foi y = 19,8124 + (-27,9578) x , p<0,0001. A correlação entre ID e FEVE 2D foi (r): -0,7012, p<0,0001, IC: -0,7923 a -0,5797. CONCLUSÃO: Nesta casuística foi observada boa correlação negativa entre o acoplamento sistólico tridimensional eletromecânico do VE e a FEVE medida ao ecocardiograma (3D e 2D).


BACKGORUND: Left ventricular (LV) electromechanical coupling (synchrony) is important in the analysis of the systolic performance, especially for the indication of cardiac resynchronization therapy in patients with advanced CHF. OBJECTIVE: To compare LV synchrony as analyzed by real-time three-dimensional (3D) echocardiography (ECHO) with LVEF measurements as obtained with 2D and 3D ECHO. METHODS: Prospective study of 92 individuals (56 men, 47 ± 10 years of age), of which 60 had normal heart structure (ECHO) and ECG (N group), and 32 had dilated cardiomyopathy (DCM group). Using 3D ECHO, LVEF, volumes and dyssynchrony index ( percentDI) for 16 LV segments were measured. Using 2D ECHO, LVEF (Simpson's method), and LV systolic and diastolic volumes were measured. Statistical analysis: Pearson's correlation coefficient, 95 percent CI, linear regression model, Bland & Altman analysis, p<0.05. RESULTS: percentDI ranged from 0.2900 to 28.1000 (5.2014±6.3281), 3D LVEF ranged from 0.17 to 0.81 (0.52±0.17); and 2D LVEF ranged from 0.3 to 0.69 (0.49±0.11). The correlation between DI and 3D LVEF was (r): -0.7432, p<0.0001, CI: -0.8227 to -0.6350, the linear relation between DI (x) and 3D LVEF (y) was y = 19.8124 + (-27.9578) x, p<0.0001. The correlation between DI and 2D LVEF was (r): -0.7012, p<0.0001, CI: -0.7923 to -0.5797. CONCLUSION: In this case series, a good negative correlation was observed between LV electromechanical three-dimensional systolic coupling and LVEF as measured by echocardiography (3D and 2D).


Assuntos
Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cardiomiopatias/fisiopatologia , Ecocardiografia Tridimensional/métodos , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda/fisiologia , Estudos de Casos e Controles , Cardiomiopatias , Modelos Lineares , Contração Miocárdica/fisiologia , Estudos Prospectivos , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda
17.
Echocardiography ; 22(5): 389-94, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15901289

RESUMO

Patients in an intensive care unit (ICU) under mechanical ventilation (MV) are very difficult to image by transthoracic echocardiography, diminishing the beneficial information that could be obtained by this noninvasive approach. The objective of this study is to assess whether the addition of a contrast agent to fundamental imaging (FI) can improve or change the initial diagnosis in cardiac postoperative patients under mechanical ventilation by enhancing endocardial border delineation and Doppler flow signal. Thirty mechanically ventilated post-cardiac surgery patients (20 men, mean age 61 +/- 13 years) were evaluated with FI before and after intravenous injection of contrast. Left ventricular endocardial border delineation score index (EBDSI), estimated left ventricular ejection fraction (LVEF), and color and spectral Doppler were analyzed. The use of contrast resulted in a significant increase in the number of well-delineated segments, with a salvage rate of 77% of nondiagnostic studies. EBDSI was 1.62 +/- 0.61, before contrast, increasing to 2.05 +/- 0.53 after it (P < 0.001). There was a change in the LVEF estimation in 5 exams, and a new wall motion abnormality was detected in other 4 exams, after the use of contrast. Moreover, a significant change was observed in the quantification of mitral regurgitation in 5 patients, in the aortic transvalvular peak gradient in 1 patient, and measurement of tricuspid regurgitation peak flow velocity in 8 patients. It is concluded that in cardiac postoperative patients under mechanical ventilation, intravenous injection of a contrast agent using FI resulted in a high salvage rate of studies and changed the initial diagnosis in a significant number of patients.


Assuntos
Meios de Contraste/administração & dosagem , Ecocardiografia Doppler em Cores/métodos , Ventrículos do Coração/diagnóstico por imagem , Respiração Artificial , Função Ventricular Esquerda/fisiologia , Albuminas/administração & dosagem , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Fluorocarbonos/administração & dosagem , Ventrículos do Coração/fisiopatologia , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/fisiopatologia , Cuidados Pós-Operatórios/métodos , Pressão Propulsora Pulmonar/fisiologia , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Volume Sistólico/fisiologia
19.
Rev. bras. ecocardiogr ; 17(3): 47-52, jul.-set. 2004. ilus, tab, graf
Artigo em Português | LILACS | ID: lil-397768

RESUMO

RESUMO: Objetivo: o ecocardiograma transtorácico tridimensional em tempo real (3D) foi recentemente desenvolvido como método de avaliação da anatomia cardíaca, e por isso necessita de validação. O objetivo deste estudo foi correlacionar a mensuração da área valvar mitral (AVM) em pacientes (pts) com estenose mitral, medida pelo ecocardiograma 3D, pelo ecocardiograma bidimensional (2D) e pelo método do tempo de decaimento de meia-pressão (PHT). Métodos:)1O pts (40 + 11 anos, 6 mulheres) com estenose valvar mitral e 8 controles normais (38+8 anos, 5 mulheres) foramsubmetidos a mensuração da AVM pelo 3D, 2D e PH7: As aferições foram realizadas separadamente por 2 observadores experientes com o emprego do equipamento Philips Sonos 7500. Resultados: no grupo com estenose mitral, a AVM medida pelo 3D variou de 0,61 cm2 a 1,57 cm2, e apresentou correlação com 2D: r- 0,91(p<0,0001), e com PHT: r- 0,92 (p<0,0001). O coeficiente de correlação intraclasse para o 3D foi 0,9084 (95,00 por cento IC,0,6929-0,9761), com concordancia interobservador de 0,9102 (95,00 por cento IC, 0,7723-.0,9712). No grupo controle, a AVM medida pelo 3D variou de 2,1 cm2 a 4 cm2, apresentou correlação com 2D: r-0,98 (p<0,0001), e com o PHT: r-(),99 (p<0,0001). O coeficiente de correlação intraclasse no grupo controle, para a medida da AVM pelo 3D foi 0,9785(95,00 por cento IC, 0,9061-0,9785), com concordáncia interobservador de 0,9002 (95,00 por cento IC, 0,7443-0,9811). Conclusão: este estudo sugere que a aferição da AVM pelo 3D em pts com estenose mitral é fadível e mostrou boa correlação com métodos previamente comprovados, podendo ser considerada no futuro como técnica útil à investigação diagnóstica préoperatória.


Assuntos
Humanos , Masculino , Feminino , Adulto , Ecocardiografia Tridimensional/métodos , Estenose da Valva Mitral/diagnóstico , Valva Mitral/anormalidades
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA