Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Pediatr Int ; 62(9): 1054-1057, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32315477

RESUMO

BACKGROUND: Early multiple-drug therapy for severe childhood immunoglobulin A (IgA) nephropathy prevents the progression of nephritis and improves the long-term prognosis. Recent studies have focused on the relationship between the pathophysiology of IgA nephropathy and tonsillar focal infection, and the efficacy of tonsillectomy with methylprednisolone pulse therapy in children has been demonstrated. However, no study has reported on the relationship between the period from diagnosis to tonsillectomy and the long-term prognosis of IgA nephropathy. METHODS: To clarify the long-term effects of an early tonsillectomy, 40 patients who were diagnosed with severe IgA nephropathy in childhood and underwent a tonsillectomy were divided into two groups based on the period from diagnosis to undergoing tonsillectomy: Group A, less than 3 years; and Group B, more than 3 years. The primary endpoint of this study was the change in the amount of proteinuria. Renal prognosis was evaluated 10 years after the diagnosis. RESULTS: This study enrolled 40 patients diagnosed with severe IgA nephropathy in childhood who underwent tonsillectomy after multiple-drug therapy with/without methylprednisolone pulse therapy at Kindai University Hospital; eight patients were excluded based on the exclusion criteria. Group A consisted of 18 patients and Group B, 14 patients. Proteinuria and hematuria levels were significantly reduced in the early surgery group (P < 0.01). No significant differences were found in serum creatinine, uric acid, and IgA/C3 ratio. CONCLUSIONS: High proteinuria levels worsen the renal prognosis in IgA nephropathy. Tonsillectomy in less than 3 years combined with multiple-drug therapy after the initial diagnosis could improve long-term prognosis.


Assuntos
Glomerulonefrite por IGA/cirurgia , Proteinúria/diagnóstico , Tonsilectomia/métodos , Adolescente , Criança , Pré-Escolar , Terapia Combinada , Creatinina/sangue , Feminino , Glomerulonefrite por IGA/tratamento farmacológico , Glucocorticoides/uso terapêutico , Hematúria/diagnóstico , Hematúria/epidemiologia , Humanos , Rim/patologia , Masculino , Metilprednisolona/uso terapêutico , Prognóstico , Proteinúria/epidemiologia , Pulsoterapia/métodos , Fatores de Tempo , Resultado do Tratamento , Ácido Úrico/análise
2.
Phys Med Biol ; 58(21): 7715-31, 2013 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-24140804

RESUMO

For high-sensitivity brain imaging, we have developed a two-head single-photon emission computed tomography (SPECT) system using a CdTe semiconductor detector and 4-pixel matched collimator (4-PMC). The term, '4-PMC' indicates that the collimator hole size is matched to a 2 × 2 array of detector pixels. By contrast, a 1-pixel matched collimator (1-PMC) is defined as a collimator whose hole size is matched to one detector pixel. The performance of the higher-sensitivity 4-PMC was experimentally compared with that of the 1-PMC. The sensitivities of the 1-PMC and 4-PMC were 70 cps/MBq/head and 220 cps/MBq/head, respectively. The SPECT system using the 4-PMC provides superior image resolution in cold and hot rods phantom with the same activity and scan time to that of the 1-PMC. In addition, with half the usual scan time the 4-PMC provides comparable image quality to that of the 1-PMC. Furthermore, (99m)Tc-ECD brain perfusion images of healthy volunteers obtained using the 4-PMC demonstrated acceptable image quality for clinical diagnosis. In conclusion, our CdTe SPECT system equipped with the higher-sensitivity 4-PMC can provide better spatial resolution than the 1-PMC either in half the imaging time with the same administered activity, or alternatively, in the same imaging time with half the activity.


Assuntos
Encéfalo/diagnóstico por imagem , Compostos de Cádmio , Semicondutores , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Adulto , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Imagens de Fantasmas , Sensibilidade e Especificidade , Adulto Jovem
3.
Ann Nucl Med ; 27(1): 17-24, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23124525

RESUMO

OBJECTIVES: Our research group developed new PET scanner with semiconductor detectors for high spatial resolution with low scatter noise. On head and neck cancer (HNC) surgery, FDG-PET may often provide false-positive findings in cervical node involvements. Accordingly, we assessed diagnostic accuracy using this new scanner in the HNC patients as compared with the conventional lutetium oxyorthosilicate (LSO) PET. METHODS: We prospectively studied FDG imaging in 35 HNC patients by both semiconductor PET and LSO-PET. At 60 min after (18)F-FDG injection, two PET scans were obtained using both scanners consecutively and in random order. Two nuclear medicine specialists scored FDG abnormalities using 5 point scale system for receiver operating characteristic (ROC) curve analysis. RESULTS: 63 suspected of metastatic or recurrent lesions were evaluated and correlated by the final confirmation by pathological findings or clinical courses (malignant 26/benign 37). Semiconductor PET showed sensitivity of 92.3 % (24/26), specificity of 51.4 % (19/37), and accuracy of 68.2 % (43/63), while LSO-PET showed sensitivity of 84.6 % (22/26), specificity of 16.2 %(6/37), and accuracy of 44.4 % (28/63), respectively. Especially, semiconductor PET accurately diagnosed as true negative in the 13 of 14 lesions only detected by LSO-PET. ROC analyses revealed the diagnostic superiority of semiconductor PET from location of- and area under curve particularly in the study of small (≤10 mm) lesions. CONCLUSION: A new novel semiconductor PET scanner can increase diagnostic accuracy with reduction in false positive findings in the HNC patients mainly due to higher spatial resolution and lower noise than the LSO-PET. This new technology can lead to more accurate diagnosis and the more optimal therapeutic tactics in head and neck surgery.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/patologia , Tomografia por Emissão de Pósitrons/instrumentação , Semicondutores , Coleta de Dados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Curva ROC
4.
J Nucl Med ; 50(1): 148-55, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19091886

RESUMO

UNLABELLED: An autoradiography method revealed intratumoral inhomogeneity in various solid tumors. It is becoming increasingly important to estimate intratumoral inhomogeneity. However, with low spatial resolution and high scatter noise, it is difficult to detect intratumoral inhomogeneity in clinical settings. We developed a new PET system with CdTe semiconductor detectors to provide images with high spatial resolution and low scatter noise. Both phantom images and patients' images were analyzed to evaluate intratumoral inhomogeneity. METHODS: This study was performed with a cold spot phantom that had 6-mm-diameter cold sphenoid defects, a dual-cylinder phantom with an adjusted concentration of 1:2, and an "H"-shaped hot phantom. These were surrounded with water. Phantom images and (18)F-FDG PET images of patients with nasopharyngeal cancer were compared with conventional bismuth germanate PET images. Profile curves for the phantoms were measured as peak-to-valley ratios to define contrast. Intratumoral inhomogeneity and tumor edge sharpness were evaluated on the images of the patients. RESULTS: The contrast obtained with the semiconductor PET scanner (1.53) was 28% higher than that obtained with the conventional scanner (1.20) for the 6-mm-diameter cold sphenoid phantom. The contrast obtained with the semiconductor PET scanner (1.43) was 27% higher than that obtained with the conventional scanner (1.13) for the dual-cylinder phantom. Similarly, the 2-mm cold region between 1-mm hot rods was identified only by the new PET scanner and not by the conventional scanner. The new PET scanner identified intratumoral inhomogeneity in more detail than the conventional scanner in 6 of 10 patients. The tumor edge was sharper on the images obtained with the new PET scanner than on those obtained with the conventional scanner. CONCLUSION: These phantom and clinical studies suggested that this new PET scanner has the potential for better identification of intratumoral inhomogeneity, probably because of its high spatial resolution and low scatter noise.


Assuntos
Neoplasias/diagnóstico por imagem , Neoplasias/patologia , Tomografia por Emissão de Pósitrons/instrumentação , Semicondutores/instrumentação , Adulto , Idoso , Bismuto , Compostos de Cádmio , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/metabolismo , Carcinoma de Células Escamosas/patologia , Feminino , Germânio , Glucose/metabolismo , Humanos , Masculino , Neoplasias Nasofaríngeas/diagnóstico por imagem , Neoplasias Nasofaríngeas/metabolismo , Neoplasias Nasofaríngeas/patologia , Neoplasias/metabolismo , Imagens de Fantasmas , Telúrio , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA