1.
Eur J Ophthalmol ; : 11206721211014381, 2021 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-33938304

RESUMO

PURPOSE: To report efficacy and safety measures of the XEN45 gel stent at 36 months in the UK National Health Service setting. METHODS: Retrospective non-comparative audit of the records of patients who underwent XEN45 implantation between June 2015 and May 2017 was performed. Main outcome measures were intraocular pressure and number of antihypertensive medications used. Failure was defined as need for further surgery or stent removal. Success was defined as a 20% decrease in intraocular pressure without the need for additional glaucoma medications or a reduction in antihypertensive medications without an increase in baseline intraocular pressure. Needling rates and preoperative factors effect were assessed. RESULTS: The cohort included 205 patients (205 eyes) with primary open angle glaucoma (84.4%), angle closure glaucoma (7.8%), or refractory glaucoma (7.8%), 62.9% had a stand-alone procedure and 37.1%, a combined phaco-XEN45 procedure. Mean intraocular pressure was 22.6 ± 7.0 mmHg at baseline compared to 14.7 ± 3.8 mmHg at 24 months and 14.0 ± 2.9 mmHg at 36 months (p < 0.001 for both). Mean number of medications used was 2.6 ± 1.1 at baseline compared to 0.5 ± 0.9 and 0.6 ± 1.0, at 24- and 36-months, respectively (p < 0.001 for both). The failure rate at 36 months was 25%. Needling was required in 36.6%. Evaluation of background factors yielded an increased failure rate in non-Caucasians compared to Caucasians (74% vs 21%, p < 0.001). CONCLUSION: XEN45 implantation is effective and safe at 36 months' follow-up. Patients should be advised regarding the risk of failure and possible need for bleb revisions. Careful patient selection may be required.

2.
Br J Ophthalmol ; 104(8): 1125-1130, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31727624

RESUMO

AIM: To report efficacy and safety measures for XEN45 in a National Health Service setting after 24-month follow-up. METHODS: This is a retrospective, non-comparative audit of records of patients who underwent XEN45 procedure between June 2015 and May 2017. The main outcome measures were intraocular pressure (IOP) reduction and number of antihypertensive medications at each timepoint. Failure was defined as requiring further surgery or removal of XEN. Success was defined as 20% reduction of IOP without additional glaucoma medications or reduction in antihypertensive medications without increase in baseline IOP. Needling rates were assessed and subgroup analysis was performed. RESULTS: A total of 151 eyes were included in the study. The main diagnoses were primary open angle glaucoma (84.1%), angle closure glaucoma (8.6%) and refractory glaucoma (7.3%). Stand-alone procedure was performed in 62.3% and combined phaco-XEN was done in 37.7%. The mean IOP at baseline was 22.1±6.5 mm Hg, and the mean IOP at 12 and 24 months was 15.4±5.9 mm Hg and 14.5±3.3 mm Hg, respectively (p<0.001). The mean number of medications was 2.77±1.1 at baseline, and 0.3±0.7 and 0.5±1.0 medications at 12 and 24 months, respectively (p<0.001). 25% of patients failed at the 24-month timepoint. Needling was required in 37.7% of patients at 24 months. Non-Caucasian ethnicity was found to be related to higher failure rate. No significant adverse events were noted. CONCLUSION: XEN45 is a viable, effective and safe procedure after 2 years of follow-up. Patients should be advised regarding failure rate as well as possible need for bleb revisions and medication use.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto/cirurgia , Implantação de Prótese , Idoso , Idoso de 80 Anos ou mais , Anti-Hipertensivos/administração & dosagem , Feminino , Seguimentos , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/efeitos dos fármacos , Pressão Intraocular/fisiologia , Masculino , Auditoria Médica , Equipamentos de Proteção , Estudos Retrospectivos , Tonometria Ocular , Resultado do Tratamento , Campos Visuais/fisiologia