Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
2.
Clin Genitourin Cancer ; 20(6): e453-e459, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35787979

RESUMO

INTRODUCTION: Maximum tumor diameter (MTD) on pretreatment magnetic resonance imaging (MRI) has the potential to further risk stratify for men with prostate cancer (PCa) prior to definitive local therapy. We aim to evaluate the prognostic impact of radiographic maximum tumor diameter (MTD) in men with localized prostate cancer. PATIENTS AND METHODS: From a single-center retrospective cohort of men receiving definitive treatment for PCa (radical prostatectomy [RP] or radiotherapy [RT]) with available pretreatment MRI, we conducted univariable and multivariable Cox proportional-hazards models for progression using clinical variables including age, NCCN risk group, radiographic extracapsular extension (ECE), radiographic seminal vesical invasion (SVI), and MTD. RP and RT cohorts were analyzed separately. Covariates were used in a classification and regression tree (CART) analysis and progression-free survival was estimated with the Kaplan-Meier method and groups were compared using log-rank tests. RESULTS: The cohort included 631 patients (n = 428 RP, n = 203 RT). CART analysis identified 4 prognostic groups for patients treated with RP and 2 prognostic groups in those treated with RT. In the RP cohort, NCCN low/intermediate risk group patients with MTD>=15 mm had significantly worse PFS than those with MTD <= 14 mm, and NCCN high-risk patients with radiographic ECE had significantly worse PFS than those without ECE. In the RT cohort, PFS was significantly worse in the cohort with MTD >= 23 mm than those <= 22 mm. CONCLUSION: Radiographic MTD may be a useful prognostic factor for patients with locoregional prostate cancer. This is the first study to illustrate that the importance of pretreatment tumor size may vary based on treatment modality.


Assuntos
Prostatectomia , Neoplasias da Próstata , Masculino , Humanos , Estudos Retrospectivos , Estadiamento de Neoplasias , Prostatectomia/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Imageamento por Ressonância Magnética
4.
Clin Genitourin Cancer ; 20(1): e68-e74, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34776367

RESUMO

BACKGROUND: Larger maximum tumor diameter (MTD) has been associated with worse prostate cancer (PCa) outcomes. However, the impact of MTD in PCa treated with external beam radiotherapy and brachytherapy boost (EBRT+BB) remains unknown. MATERIALS AND METHODS: Patients with PCa treated with EBRT+BB were identified from an institutional database. Clinical data including MTD, age, androgen deprivation therapy (ADT) use, prostate specific antigen (PSA), International Society of Urologic Pathology (ISUP) group, clinical T-stage, and presence of adverse pathology on imaging were retrospectively collected. Multivariable and univariable cox proportional hazards models for biochemical failure (BF) and distant metastasis (DM) were produced with MTD grouped by receiver operating characteristic (ROC) cut-point. Cumulative hazard functions for BF and DM were compared with log-rank test and stratified by ISUP group. RESULTS: Of 191 patients treated with EBRT+BB, 113 had MTD measurements available. Larger MTD was associated with increased ADT use and seminal vesicle involvement. ROC optimization identified MTD of 24 mm as the optimal cut-point for both BF and DM. MTD was independently associated with both BF (HR 8.61, P = .048, 95% CI 1.02-72.97) and DM (HR 8.55, P = .05, 95% CI 1.00-73.19). In patients with ISUP group 4 to 5 disease, MTD > 24 mm was independently associated with increased risk of DM (HR 10.13, P = .04, 95% CI 1.13-91.12). CONCLUSIONS: This is the first study to evaluate MTD in the setting of EBRT+BB. These results demonstrate that MTD is independently associated with BF and metastasis. This suggests a possible role for MTD in risk assessment models and clinical decision-making for men receiving EBRT+BB.


Assuntos
Braquiterapia , Neoplasias da Próstata , Antagonistas de Androgênios/uso terapêutico , Braquiterapia/efeitos adversos , Braquiterapia/métodos , Humanos , Imageamento por Ressonância Magnética , Masculino , Antígeno Prostático Específico , Neoplasias da Próstata/patologia , Estudos Retrospectivos
5.
J Nucl Med Technol ; 45(1): 42-49, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28154020

RESUMO

Glomerular filtration rate (GFR) measurements are critical in patients with hepatic cirrhosis but potentially erroneous when based on serum creatinine. New equations for estimated GFR (eGFR) have shown variable performance in cirrhotics, possibly because of inaccuracies in reference methods for measured GFR (mGFR). The primary objective was to compare the performance of 4 improved eGFR equations with a 1-compartment, 2-sample plasma slope intercept 99mTc-DTPA mGFR method to determine whether any of the eGFR calculations could replace plasma 99mTc-DTPA mGFR in patients with cirrhosis. The secondary objective was to test the hypothesis that mGFR using voluntary voided urine collections introduces error compared with plasma-only methods. Methods: Fifty-four patients with hepatic cirrhosis underwent mGFR determinations from 2 plasma samples at 1 and 3 h after intravenous administration of 185 MBq of 99mTc-DTPA. GFR was also generated by a UV/P calculation derived from blood and urine samples. These mGFRs were compared with the eGFRs generated by 4 estimating equations: MDRD (Modified Diet in Renal Disease), CKD-EPI (Chronic Kidney Disease-Epidemiology Collaboration) (serum creatinine [SCr]), CKD-EPI (cystatin [CysC]), and CKD-EPI (CysC+SCr). eGFRs were compared with mGFRs by Pearson correlation, precision, bias, percentage bias, and accuracy (eGFRs varying by <10% [p10], <20% [p20] or <30% [p30] from the corresponding mGFR). Results: All eGFRs showed poorer performance when the UV/P 99mTc-DTPA mGFR was used as the reference than when the plasma 99mTc-DTPA mGFR was used. When compared with the plasma 99mTc-DTPA mGFR method, the performance of all eGFR equations was superior to most published reports. There was a moderately good positive correlation between eGFRs and mGFRs. When compared with plasma 99mTc-DTPA mGFR, precision of eGFRs was in the range of 14-20 mL/min and showed a negligible bias. Compared with the plasma 99mTc-DTPA mGFR, CKD-EPI (CysC+SCr) showed the best overall performance and accuracy, at 85.19% (p30), 75.93% (p20), and 42.59% (p10). Conclusion: Estimating equations for measuring eGFR performed better than in most published reports, attributable to use of the plasma 99mTc-DTPA mGFR method as a reference. CKD-EPI (CysC+SCr) eGFR showed the best overall performance. However, more discriminating methods may be required when accurate GFR measurements are necessary. mGFR measurements using urine collections may introduce error compared with plasma-only methods.


Assuntos
Taxa de Filtração Glomerular , Testes de Função Renal/métodos , Cirrose Hepática/sangue , Cirrose Hepática/fisiopatologia , Pentetato de Tecnécio Tc 99m/sangue , Adulto , Idoso , Feminino , Humanos , Cirrose Hepática/complicações , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/complicações
6.
Magn Reson Med ; 71(6): 2231-42, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24105740

RESUMO

PURPOSE: The objective of this study was to determine whether a sodium phased array would improve sodium breast MRI at 3 T. The secondary objective was to create acceptable proton images with the sodium phased array in place. METHODS: A novel composite array for combined proton/sodium 3 T breast MRI is compared with a coil with a single proton and sodium channel. The composite array consists of a 7-channel sodium receive array, a larger sodium transmit coil, and a 4-channel proton transceive array. The new composite array design utilizes smaller sodium receive loops than typically used in sodium imaging, uses novel decoupling methods between the receive loops and transmit loops, and uses a novel multichannel proton transceive coil. The proton transceive coil reduces coupling between proton and sodium elements by intersecting the constituent loops to reduce their mutual inductance. The coil used for comparison consists of a concentric sodium and proton loop with passive decoupling traps. RESULTS: The composite array coil demonstrates a 2-5× improvement in signal-to-noise ratio for sodium imaging and similar signal-to-noise ratio for proton imaging when compared with a simple single-loop dual resonant design. CONCLUSION: The improved signal-to-noise ratio of the composite array gives breast sodium images of unprecedented quality in reasonable scan times.


Assuntos
Neoplasias da Mama/diagnóstico , Imageamento por Ressonância Magnética/instrumentação , Desenho de Equipamento , Feminino , Humanos , Aumento da Imagem/métodos , Prótons , Sódio
7.
Kidney Int ; 85(4): 768-78, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24067433

RESUMO

Established as a method to study anatomic changes, such as renal tumors or atherosclerotic vascular disease, magnetic resonance imaging (MRI) to interrogate renal function has only recently begun to come of age. In this review, we briefly introduce some of the most important MRI techniques for renal functional imaging, and then review current findings on their use for diagnosis and monitoring of major kidney diseases. Specific applications include renovascular disease, diabetic nephropathy, renal transplants, renal masses, acute kidney injury, and pediatric anomalies. With this review, we hope to encourage more collaboration between nephrologists and radiologists to accelerate the development and application of modern MRI tools in nephrology clinics.


Assuntos
Nefropatias/diagnóstico , Imageamento por Ressonância Magnética/métodos , Nefrologia/tendências , Animais , Humanos
9.
Acad Radiol ; 20(2): 137-47, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23099241

RESUMO

RATIONALE AND OBJECTIVES: The goal of the study is to develop a technique to achieve accurate volumetric breast tissue segmentation using magnetic resonance imaging (MRI) data. This segmentation can be useful to aid in the diagnosis of breast cancers and to assess breast cancer risk based on breast density. Tissue segmentation is also essential for development of acoustic and thermal models used in magnetic resonance guided high-intensity focused ultrasound treatment of breast lesions. MATERIALS AND METHODS: In addition to commonly used T1-, T2-, and proton density-weighted images, three-point Dixon water- and fat-only images were also included as part of the multiparametric inputs to a tissue segmentation algorithm using a hierarchical support vector machine (SVM). The effectiveness of a variety of preprocessing schemes was evaluated through two in vivo datasets. The performance of the hierarchical SVM was investigated and compared to the conventional classification algorithms-conventional SVM and fuzzy C-mean (FCM). RESULTS: The need for co-registration, zero-filled interpolation, coil sensitivity correction, and optimal SNR reconstruction before the final stage classification was demonstrated. The overlap ratios of the hierarchical SVM, conventional SVM and FCM were 93.25%-94.08%, 81.68-92.28%, and 75.96%-91.02%, respectively. Classification outputs from in vivo experiments showed that the presented methodology is consistent and outperforms other algorithms. CONCLUSION: The presented hierarchical SVM-based technique showed promising results in automatically segmenting breast tissues into fat, fibroglandular tissue, skin, and lesions. The results provide evidence that both the multiparametric breast MRI inputs and the preprocessing procedures contribute to the high accuracy of tissue classification.


Assuntos
Algoritmos , Artefatos , Neoplasias da Mama/patologia , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Reconhecimento Automatizado de Padrão/métodos , Máquina de Vetores de Suporte , Feminino , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
J Magn Reson Imaging ; 31(6): 1371-8, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20512889

RESUMO

PURPOSE: To prospectively investigate whether a rapid dynamic MRI protocol, in conjunction with pharmacokinetic modeling, could provide diagnostically useful information for discriminating biopsy-proven benign lesions from malignancies. MATERIALS AND METHODS: Patients referred to breast biopsy based on suspicious screening findings were eligible. After anatomic imaging, patients were scanned using a dynamic protocol with complete bilateral breast coverage. Maps of pharmacokinetic parameters representing transfer constant (K(trans)), efflux rate constant (k(ep)), blood plasma volume fraction (v(p)), and extracellular extravascular volume fraction (v(e)) were averaged over lesions and used, with biopsy results, to generate receiver operating characteristic curves for linear classifiers using one, two, or three parameters. RESULTS: Biopsy and imaging results were obtained from 93 lesions in 74 of 78 study patients. Classification based on K(trans) and k(ep) gave the greatest accuracy, with an area under the receiver operating characteristic curve of 0.915, sensitivity of 91%, and specificity of 85%, compared with values of 88% and 68%, respectively, obtained in a recent study of clinical breast MRI in a similar patient population. CONCLUSION: Pharmacokinetic classification of breast lesions is practical on modern MRI hardware and provides significant accuracy for identification of malignancies. Sensitivity of a two-parameter linear classifier is comparable to that reported in a recent multicenter study of clinical breast MRI, while specificity is significantly higher.


Assuntos
Doenças Mamárias/diagnóstico , Neoplasias da Mama/diagnóstico , Mama/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Biópsia , Doenças Mamárias/patologia , Neoplasias da Mama/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Farmacocinética , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
NMR Biomed ; 23(1): 97-104, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19777499

RESUMO

A rapid method of simultaneous T(1) and T(2) measurement is presented which uses a segmented echo-planar readout with varying repetition times (TR) and echo times (TE). This method is useful in T(1) mapping for analysis of dynamic contrast enhanced MRI (DCE-MRI), where T(1) can be used to estimate contrast agent concentration. In the application of this method to dynamic imaging, the equilibrium magnetization is measured on pre-contrast images and incorporated into post-contrast T(1) calculations for improved accuracy. Simultaneous T(2) measurement allows correction of T(2) effects in the T(1) map which may occur at high contrast agent concentrations, and is performed without significant imaging time penalty. Phantom and in vivo results show the usefulness of this technique for analysis of contrast enhancement kinetics. Accurate rapid contrast agent concentration measurement may be useful for analyzing the distribution and kinetics of contrast agents or labeled pharmaceuticals.


Assuntos
Meios de Contraste/metabolismo , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética , Algoritmos , Animais , Linhagem Celular Tumoral , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Camundongos , Camundongos Nus , Neoplasias/metabolismo , Neoplasias/patologia , Imagens de Fantasmas , Reprodutibilidade dos Testes
13.
Biomacromolecules ; 9(10): 2742-8, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18771313

RESUMO

The purpose of this study was to design and prepare macromolecular contrast agents (CAs) with a precisely defined globular structure for MR angiography and tumor angiogenesis imaging. Generations 1 through 3 (Gd-DOTA-monoamide)-poly-L-lysine octasilsesquioxane dendrimers were prepared as nanoglobular MRI CAs. The nanoglobular Gd(III) chelates had a well-defined compact globular structure and high loading of Gd-DOTA-monoamide at their surface. The size of the G1, G2, and G3 nanoglobular MRI CAs was approximately 2.0, 2.4, and 3.2 nm, respectively. The T1 relaxivity of G1, G2, and G3 nanoglobular MRI CAs was approximately 6.4, 7.2, and 10.0 mM(-1) sec(-1) at 3T, respectively. The nanoglobular MRI CAs showed size-dependent contrast enhancement within the mouse vasculature, which gradually decayed to baseline after a 60 min session. The G3 nanoglobular CA resulted in more significant and prolonged vascular enhancement than the smaller nanoglobular agents at 0.03 mmol Gd/kg. The G3 agent also provided significant and prolonged contrast enhancement in the heart and vasculature at a dose as low as 0.01 mmol Gd/kg, 1/10th of the regular clinical dose. Significant enhancement was observed in tumor for all CAs. The nanoglobular CAs cleared via renal filtration and accumulated in the urinary bladder as shown in the dynamic MR images. The nanoglobular Gd(III) chelates are effective intravascular MRI CAs at substantially reduced doses. The nanoglobular MRI CAs are promising for further preclinical development for MR angiography and MR imaging of tumor angiogenesis.


Assuntos
Amidas/química , Meios de Contraste/química , Compostos Heterocíclicos/química , Angiografia por Ressonância Magnética/instrumentação , Compostos Organometálicos/química , Animais , Linhagem Celular Tumoral , Quelantes/farmacologia , Feminino , Gadolínio/química , Angiografia por Ressonância Magnética/métodos , Camundongos , Camundongos Nus , Conformação Molecular , Nanopartículas/química , Neoplasias/patologia , Neovascularização Patológica
14.
J Thorac Imaging ; 22(3): 259-62, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17721337

RESUMO

Broncholithiasis is the presence of intrabronchial calcification or ossification. We report a case of broncholiths resulting from extrusion of calcified mediastinal lymph node into a bronchus associated with esophagobronchial fistula that became more symptomatic after bronchoscopic removal of the broncholiths.


Assuntos
Broncopatias/diagnóstico , Fístula Brônquica/diagnóstico , Cálculos/diagnóstico , Fístula Esofágica/diagnóstico , Adulto , Broncopatias/diagnóstico por imagem , Broncopatias/cirurgia , Fístula Brônquica/diagnóstico por imagem , Fístula Brônquica/cirurgia , Broncoscopia , Cálculos/diagnóstico por imagem , Cálculos/cirurgia , Meios de Contraste , Diagnóstico Diferencial , Fístula Esofágica/diagnóstico por imagem , Fístula Esofágica/cirurgia , Humanos , Iohexol , Masculino , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA