1.
Cochrane Database Syst Rev ; 6: CD012923, 2021 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-34085713

RESUMO

BACKGROUND: Thoracic aortic arch aneurysms (TAAs) can be a life-threatening condition due to the potential risk of rupture. Treatment is recommended when the risk of rupture is greater than the risk of surgical complications. Depending on the cause, size and growth rate of the TAA, treatment may vary from close observation to emergency surgery. Aneurysms of the thoracic aorta can be managed by a number of surgical techniques. Open surgical repair (OSR) of aneurysms involves either partial or total replacement of the aorta, which is dependent on the extent of the diseased segment of the aorta. During OSR, the aneurysm is replaced with a synthetic graft. Hybrid repair (HR) involves a combination of open surgery with endovascular aortic stent graft placement. Hybrid repair requires varying degrees of invasiveness, depending on the number of supra-aortic branches that require debranching. The hybrid technique that combines supra-aortic vascular debranching with stent grafting of the aortic arch has been introduced as a therapeutic alternative. However, the short- and long-term outcomes of HR remain unclear, due to technical difficulties and complications as a result of the angulation of the aortic arch as well as handling of the arch during surgery. OBJECTIVES: To assess the effectiveness and safety of HR versus conventional OSR for the treatment of TAAs. SEARCH METHODS: The Cochrane Vascular Information Specialist searched the Cochrane Vascular Specialised Register, CENTRAL, MEDLINE, Embase, CINAHL and AMED databases and World Health Organization International Clinical Trials Registry Platform and ClinicalTrials.gov trials registers to 22 March 2021. We also searched references of relevant articles retrieved from the electronic search for additional citations. SELECTION CRITERIA: We considered for inclusion in the review all published and unpublished randomised controlled trials (RCTs) and controlled clinical trials (CCTs) comparing HR to OSR for TAAs. DATA COLLECTION AND ANALYSIS: Two review authors independently screened all titles and abstracts obtained from the literature search to identify those that met the inclusion criteria. We retrieved the full text of studies deemed as potentially relevant by at least one review author. The same review authors screened the full-text articles independently for inclusion or exclusion. MAIN RESULTS: No RCTs or CCTs met the inclusion criteria for this review. AUTHORS' CONCLUSIONS: Due to the lack of RCTs or CCTs, we were unable to determine the safety and effectiveness of HR compared to OSR in people with TAAs, and we are unable to provide high-certainty evidence on the optimal surgical intervention for this cohort of patients. High-quality RCTs or CCTs are necessary, addressing the objective of this review.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Resultados Negativos , Humanos
2.
J Cardiothorac Surg ; 15(1): 235, 2020 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-32878643

RESUMO

OBJECTIVE(S): The Fontan procedure is a common palliative intervention for sufferers of single ventricle congenital heart defects that results in an anastomosis of the venous return to the pulmonary arteries called the total cavopulmonary connection (TCPC). In patients with palliated single ventricular heart defects, the Fontan circulation passively directs systemic venous return to the pulmonary circulation in the absence of a functional sub-pulmonary ventricle. Therefore, the Fontan circulation is highly dependent on favourable flow and energetics, and minimal energy loss is of great importance. The majority of in vitro studies, to date, employ a rigid TCPC model. Recently, few studies have incorporated flexible TCPC models, without the inclusion of commercially available conduits used in these surgical scenarios. METHOD: The methodology set out in this study successfully utilizes patient-specific phantoms along with the corresponding flowrate waveforms to characterise the flow haemodynamic performance of extracardiac Gore-Tex conduits. This was achieved by comparing a rigid and flexible TCPC models against a flexible model with an integrated Gore-Tex conduit. RESULTS: The flexible model with the integrated Gore-Tex graft exhibited greater levels of energy losses when compared to the rigid walled model. With this, the flow fields showed greater levels of turbulence in the complaint and Gore-Tex models compared to the rigid model under ultrasound analysis. CONCLUSION: This study shows that vessel compliance along with the incorporation of Gore-Tex extracardiac conduits have significant impact on the flow haemodynamics in a patient-specific surgical scenario.


Assuntos
Prótese Vascular , Hemodinâmica , Politetrafluoretileno , Pré-Escolar , Técnica de Fontan/instrumentação , Cardiopatias Congênitas/cirurgia , Humanos , Técnicas In Vitro , Masculino , Desenho de Prótese , Artéria Pulmonar/cirurgia , Veias Cavas/cirurgia
3.
Frontline Gastroenterol ; 10(4): 356-363, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31656560

RESUMO

BACKGROUND: Physician training in the UK is undergoing considerable change due to the implementation of recommendations made in the Shape of Training Review. In particular, higher specialty training (HST), including gastroenterology, will be shortened from 5 to 4 years. This will also incorporate general internal medicine (GIM) training. There is concern among gastroenterologists regarding how high-quality gastroenterology training will be delivered in 4 years. METHODS: The 2018 British Society of Gastroenterology (BSG) trainees' survey results were used to examine the potential impact of a 4-year HST period on achieving key competencies in gastroenterology. RESULTS: 291 (49.4%) gastroenterology trainees responded. Satisfaction with gastroenterology training was high (79.6% respondents), and self-reported confidence in hepatology training was also high (84% senior respondents). However, only half (51.1%) of the respondents achieved complete colonoscopy certification by their final year of training. Comparison with the 2014 BSG trainees' survey demonstrated that the number of endoscopy procedures achieved by trainees has reduced in sigmoidoscopy (p=0.006) and colonoscopy (p<0.001). The proportion of time spent in GIM training has increased since the last survey, with 81.8% of the respondents spending more than 25% of their time in GIM. GIM training was reported to be a key barrier to adequate gastroenterology and endoscopy training. CONCLUSION: These data indicate significant barriers to delivering gastroenterology and endoscopy training within the current 5-year programme. Novel strategies will be required to improve the rate of progression in endoscopy training, in particular if high-quality gastroenterology HST training is to be delivered in 4 years.

4.
Int J Comput Assist Radiol Surg ; 14(8): 1415-1430, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31054129

RESUMO

PURPOSE: The presence and progression of heart failure (HF) are associated with cardiac remodelling, defined as cellular, molecular and interstitial changes which occur after injury and manifest as changes in left ventricular (LV) size, mass, geometry and function. This research study was designed to investigate the changes to LV morphology and shape which occur in the presence of heart failure using three-dimensional (3D) modelling and analysis of cardiac-gated CT scans from both healthy individuals and patients classified with HF. METHODS: A number of quantitative and qualitative strategies were applied to cardiac CT scans of HF patients and healthy controls (n = 7) in order to analyse changes to LV size, shape and structure and to examine LV remodelling in the different classes of HF. Three-dimensional wireframe representations of endocardial and epicardial borders were created, three-dimensional computer stereolithography models of the inner LV cavity and myocardial wall segments were generated and three-dimensionally printed and a number of clinical LV dimension and shape indices were measured. All data were analysed using one-way ANOVA with post hoc Tukey method for multiple comparisons for significant variables. RESULTS: Results of most significance included abnormalities in LV mass and end-systolic dimensions and significantly increased septal wall thickness among mid-range ejection fraction cases. Also of importance were significant increases in both dimension-based and volumetric sphericity index measures in all HF cases. Three-dimensional printed models provided qualitative information as to changes in inner LV cavity and myocardial wall morphology across the cardiac cycle for healthy and HF cases and validated quantitative findings. CONCLUSION: Findings from this study can successfully be applied to motivate the research and development of new HF treatment strategies and devices as well as for the development of a realistic cardiac simulator system.


Assuntos
Insuficiência Cardíaca/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Idoso , Simulação por Computador , Feminino , Coração/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Pesquisa Qualitativa , Estereolitografia , Disfunção Ventricular Esquerda/fisiopatologia , Remodelação Ventricular
6.
J Vasc Surg ; 65(4): 951-963, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27889286

RESUMO

OBJECTIVE: Managing symptomatic chronic type B aortic dissection (SCTBAD) by the Streamliner Multilayer Flow Modulator (SMFM) stent (Cardiatis, Isnes, Belgium) is akin to provisional structural support to induce complete attachment of the dissection flap, but with the ability of aortic remolding. This study investigated the SMFM's capability to enact healing of SCTBAD. METHODS: Clinical data for 12 cases comprising preoperative and postoperative treatment of SCTBAD were obtained from a multicenter database hosted by the Multilayer Flow Modulator Global Registry, Ireland. A biomechanical analysis, by means of computational fluid dynamics modeling, of the hemodynamic effects and branch patency associated with the use of the SMFM was performed for all cases. The mean length of the dissections was 30.23 ± 13.3 cm. There were 30 SMFMs used, which covered 69 aortic branches. RESULTS: At 1-year follow-up, the true lumen volume increased from 175.74 ± 98.83 cm3 to 209.87 ± 128.79 cm3; the false lumen decreased from 135.2 ± 92.03 cm3 to 123.19 ± 110.11 cm3. The false lumen index decreased from 0.29 ± 0.13 (preoperatively) to 0.21 ± 0.15 (postoperatively). The primary SMFM treatment of SCTBAD increased carotid perfusion by 35% ± 21% (P = .0216) and suprarenal perfusion by 78% ± 32% (P = .001). The wall pressure distribution blended along the newly enlarged true lumen, whereas the false lumen wall pressure decreased by 6.23% ± 4.81% for the primary group (cases 1-7) and by 3.84% ± 2.59% for the secondary group (cases 8-12). CONCLUSIONS: SMFM reduces the false lumen wall pressure through flow modulation. It preserves patency of all branches, minimizing the incidence of short-term complications. The SMFM is a valuable option in managing primary SCTBAD, without midterm complications.


Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/instrumentação , Modelos Cardiovasculares , Adulto , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/fisiopatologia , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/fisiopatologia , Aortografia/métodos , Pressão Arterial , Fenômenos Biomecânicos , Velocidade do Fluxo Sanguíneo , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Doença Crônica , Angiografia por Tomografia Computadorizada , Simulação por Computador , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fluxo Sanguíneo Regional , Sistema de Registros , Estresse Mecânico , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular , Remodelação Vascular
7.
J Neurointerv Surg ; 9(5): 486-491, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27127231

RESUMO

BACKGROUND: Translational research on clot composition may be advanced by the use of clot analogs for the preclinical evaluation of mechanical thrombectomy devices. This work describes a novel set of clot analogs to represent a diverse range of fibrin and red blood cell (RBC) compositions for use in acute ischemic stroke (AIS) occlusion models. METHOD: Fresh whole blood obtained from ovine species was used to create seven different clot analog types. Five replicates were formed for each clot type. Varying amounts of whole blood constituents were mixed with thrombotic factors to create clots of varying compositions. Following histological processing, five sections from each clot were stained with H&E and Martius Scarlet Blue. Fibrin, RBC and white blood cell compositions were quantified. RESULTS: Histological examination demonstrated that the clot types had a distinct RBC and fibrin composition. No significant difference in composition was shown between replicates (p>0.05), indicating that the method of clot formation was reproducible. Percentage fibrin composition of the clot types was 1%, 8%, 31%, 38%, 64%, 79%, and 100%. A significant difference in fibrin and RBC composition between clot types was observed (p<0.05). CONCLUSIONS: Seven different clot types were developed to replicate common AIS thrombi. These clot analogs may be beneficial for the preclinical evaluation of endovascular therapies, and may be applied to interventional technique training.


Assuntos
Isquemia Encefálica/patologia , Eritrócitos/química , Fibrina/química , Acidente Vascular Cerebral/patologia , Pesquisa Translacional Biomédica/métodos , Animais , Feminino , Humanos , Trombose Intracraniana/patologia , Masculino , Ovinos
8.
Med Eng Phys ; 38(12): 1458-1473, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27773830

RESUMO

There are several issues attributed with abdominal aortic aneurysm endovascular repair. The positioning of bifurcated stent-grafts (SG) may affect SG hemodynamics. The hemodynamics and geometrical parameters of crossing or non-crossing graft limbs have not being totally accessed. Eight patient-specific SG devices and four pre-operative cases were computationally simulated, assessing the hemodynamic and geometrical effects for crossed (n= 4) and non-crossed (n= 4) configurations. SGs eliminated the occurrence of significant recirculations within the sac prior treatment. Dean's number predicted secondary flow locations with the greatest recirculations occurring at the outlets especially during the deceleration phase. Peak drag force varied from 3.9 to 8.7N, with greatest contribution occurring along the axial and anterior/posterior directions. Average resultant drag force was 20% smaller for the crossed configurations. Maximum drag force orientation varied from 1.4° to 51°. Drag force angle varied from 1° to 5° during one cardiac cycle. 44% to 62% of the resultant force acted along the proximal centerline where SG migration is most likely to occur. The clinician's decision for SG positioning may be a critical parameter, and should be considered prior to surgery. All crossed SG devices had an increased spiral flow effect along the distal legs with reductions in drag forces.


Assuntos
Aneurisma da Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/terapia , Hemodinâmica , Medicina de Precisão/instrumentação , Stents , Humanos , Modelos Biológicos
9.
J Thorac Cardiovasc Surg ; 152(5): 1309-1318.e5, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27485677

RESUMO

OBJECTIVE: Aortic arch aneurysms and thoracoabdominal aortic arch aneurysms are technically challenging to manage by established surgical and endovascular methods. The Streamliner Multilayer Flow Modulator device (Cardiatis, Isnes, Brussels, Belgium) offers an unorthodox option for these high-risk cases. The Streamliner device for aortic arch repair (STAR) study investigated complex aneurysm cases managed by the Streamliner Multilayer Flow Modulator device and offers an analytic solution for a clinical dilemma. METHODS: Six cases were included, with a 1-year follow-up, comprising 4 pure arch aneurysms and 2 thoracoabdominal aortic arch aneurysms Crawford type I, from a multicenter database hosted by the Streamliner Multilayer Flow Modulator Global Registry. A total of 50% of cases were performed under instructions for use. All were American Society of Anesthesiology IV and originated from zone 0. All cases were computationally analyzed, which consisted of (1) simulating the treatment on the basis of the postoperative data, (2) repositioning the stents for the failed technical cases, and (3) assessing the effects of overlapping devices on branch patency. RESULTS: Correct device placement induced aneurysm flow streamlining, which reduced the dynamic pressure by 23% to 66%, whereas incorrect placements promoted Failure Mode I with 58% and 16% dynamic pressure increases and aneurysm volume expansion up to 23%. Overlapped devices improved distal perfusion by increasing arch branch outflows from 5% to 24%. The Streamliner Multilayer Flow Modulator device does not benefit a sac volume greater than 400 cm3. CONCLUSIONS: The Streamliner Multilayer Flow Modulator device is a new technology that can manage complex aortic arch aneurysms and thoracoabdominal aortic arch aneurysms with favorable clinical outcomes if it is performed under instructions for use. Careful procedure planning and perioperative virtual stent placement will avoid foreshortening, prevent inadequate stent overlap lengths, and provide insight into the sufficient numbers of required implanted devices.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Prótese Vascular , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Tomografia Computadorizada por Raios X , Resultado do Tratamento
10.
Proc Inst Mech Eng H ; 230(2): 153-65, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26721906

RESUMO

Coronary artery disease is one of the leading causes of cardiovascular deaths worldwide. Approximately 70% of patients requiring coronary revascularisation receive endovascular stents. The endovascular procedure is the preferred option due to its minimally invasive nature when compared to open heart surgery. Stent delivery is paramount for the success of the endovascular procedure. Catheter delivery forces within tortuous blood vessels can produce vasoconstriction and injury, resulting in reactive intimal proliferation or distal embolisation associated with end-organ ischaemia and infarction. Trackability is evaluated by most medical device companies for further development of their delivery systems. Relevant device design attributes must be tested in settings which simulate aspects of the intended use conditions, such as vessel geometry and compliance. Various tortuosity parameters are used to facilitate endovascular intervention planning. This study assessed the significance and correlation between the trackability forces for a coronary stent system with various geometrical parameters based on patient-specific geometries. A motorised delivery system delivered a commercially available coronary stent system and monitored the trackability forces along three phantom patient-specific thin-walled, compliant coronary vessels supported by a cardiac phantom model. The maximum trackability forces, curvature and torsion values ranged from 0.31 to 0.87 N, 0.06 to 0.22 mm(-1) and -11.1 to 5.8 mm(-1), respectively. The trackability forces were significantly different between all vessels (p < 0.002), while the tortuosity parameters were not significantly different (p > 0.05). A new tortuosity parameter-coined tracking curvature which considers the lumen radius as well as the curvature along the centreline was statistically different (p < 0.002) for all vessels and correlated with the trackability forces. There was a strong correlation between the cumulative trackability force and the cumulative tracking curvature. Tracking curvature could be used as a predictive clinical tool to aid stent delivery to the vicinity of the lesion.


Assuntos
Catéteres , Procedimentos Endovasculares/métodos , Modelos Cardiovasculares , Imagens de Fantasmas , Stents , Cirurgia Assistida por Computador/métodos , Doença da Artéria Coronariana/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Medicina de Precisão , Cirurgia Assistida por Computador/instrumentação
11.
Hemodial Int ; 18(1): 212-4, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24015751

RESUMO

The dialysis patient is prone to elevations in the calcium phosphorus product and hyperparathyroidism, which contributes to valvular and vascular calcification. We present the case of a young lady on chronic dialysis that developed mitral calcification complicated by severe mitral stenosis, caseous calcification and retinal embolization. She subsequently required mitral valve replacement.


Assuntos
Calcinose/etiologia , Hiperparatireoidismo/terapia , Estenose da Valva Mitral/etiologia , Diálise Renal , Adulto , Calcinose/patologia , Calcinose/cirurgia , Feminino , Humanos , Hiperparatireoidismo/complicações , Estenose da Valva Mitral/patologia , Estenose da Valva Mitral/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA