Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 17: 152, 2016 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-27060078

RESUMO

BACKGROUND: Animal models serve as an important tool to understand peri-implant infection. Most of the models use high bacterial loads (>10(4) colony forming units, CFU) to provide high infection rates. Therefore these animals evolve rather similarly, making comparison between groups and statistical analysis possible. On the other hand, to mimic clinical constellation of surgery-related infections the use of low amounts of bacteria would be more advantageous. METHODS: We developed a metaphyseal rat model of peri-implant bone infection with low amount of bacterial loads (10(2) and 10(3) CFU of Staphylococcus aureus) and investigated osseointegration of the implants coated with hydroxyapatite (HA) and low-dosed HA-silver (HA-Ag). Non-infected implants served as controls. After 6 weeks rats were sacrificed and implants evaluated for osseointegration and infection. RESULTS: Infection of implanted devices was reliably induced, independently whether 10(2) or 10(3) CFU of S. aureus were inoculated and HA or HA-Ag coated implants were used. No systemic infection was present in any of the animals at the time of sacrifice, and no animal developed acute infection requiring premature sacrifice. All CFU counts of the implant and the bone at sacrifice were significantly higher than the inoculated load (p < .05). All sterilely inserted implants showed excellent osseointegration and no infection. CONCLUSIONS: Our present study of a rat tibia model reliably induced osteomyelitis in the metaphysis with low-doses of bacteria. The addition of low-dosed Ag to the implant coating was not able to reduce the infection rates. The results demonstrate that it is possible to develop a model of implant-related osteomyelitis in rats with low amounts of bacteria to better mimic clinical constellations. No other promoters of infection besides insertion of the screw implant were used in this model.


Assuntos
Parafusos Ósseos/microbiologia , Modelos Animais de Doenças , Osteomielite/diagnóstico por imagem , Infecções Estafilocócicas/diagnóstico por imagem , Staphylococcus aureus , Animais , Parafusos Ósseos/efeitos adversos , Masculino , Osteomielite/etiologia , Osteomielite/patologia , Ratos , Ratos Wistar , Infecções Estafilocócicas/complicações , Infecções Estafilocócicas/patologia
2.
J Neurol ; 262(1): 179-86, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25359262

RESUMO

Patients with glioblastoma multiforme (GBM) and symptomatic seizures are in need of a sufficient antiepileptic treatment. Haematological toxicity is a limiting side effect of both, first line radio-chemotherapy with temozolomide (TMZ) and co-medication with antiepileptic drugs. Valproic acid (VPA) and levetiracetam (LEV) are considered favourable agents in brain tumor patients with seizures, but are commonly reported to induce haematological side effects on their own. We hypothesized, that antiepileptic treatment with these agents has no increased impact on haematological side effects during radio-chemotherapy in the first line setting. We included 104 patients from two neuro-oncologic centres with GBM and standard radio-chemotherapy in a retrospective cohort study. Patients were divided according to their antiepileptic treatment with either VPA, LEV or without antiepileptic drug therapy (control group). Declines in haemoglobin levels and absolute blood cell counts for neutrophil granulocytes, lymphocytes and thrombocytes were analyzed twice during concomitant and once during adjuvant phase. A comparison between the examined groups was performed, using a linear mixed model. Neutrophil granulocytes, lymphocytes and thrombocytes significantly decreased over time in all three groups (all p < 0.012), but there was no significant difference between the compared groups. A significant decline in haemoglobin was observed in the LEV treated group (p = 0.044), but did not differ between the compared groups. As a novel finding, this study demonstrates that co-medication either with VPA or LEV in GBM patients undergoing first line radio-chemotherapy with TMZ has no additional impact on medium-term haematological toxicity.


Assuntos
Anticonvulsivantes/efeitos adversos , Células Sanguíneas/efeitos dos fármacos , Neoplasias Encefálicas/terapia , Quimiorradioterapia/métodos , Glioblastoma/terapia , Hemoglobinas/efeitos dos fármacos , Piracetam/análogos & derivados , Convulsões/tratamento farmacológico , Ácido Valproico/efeitos adversos , Adulto , Idoso , Anticonvulsivantes/administração & dosagem , Contagem de Células Sanguíneas , Neoplasias Encefálicas/complicações , Feminino , Glioblastoma/complicações , Humanos , Levetiracetam , Masculino , Pessoa de Meia-Idade , Piracetam/administração & dosagem , Piracetam/efeitos adversos , Estudos Retrospectivos , Convulsões/etiologia , Ácido Valproico/administração & dosagem , Adulto Jovem
3.
Orthopedics ; 34(12): e816-20, 2011 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-22146195

RESUMO

Ultrasound-navigated cementless total hip arthroplasty (THA) was performed in 10 consecutive patients with primary osteoarthritis of the hip between August 2008 and October 2009 (M:F, 6:4; median age, 61 years; age range, 30-86 years). The pelvic orientation was defined by preoperative digitization and registration of bony landmarks. Cup inclination and anteversion were documented for each patient intraoperatively (epidigitized vs ultrasound-assessed landmarks). The median difference between the palpated and ultrasound anterior pelvic plane was 8° (range, 4°-18°) for pelvic tilt (rotation around the transversal axis), 1° (range, -3° to 2°) for rotation around the longitudinal axis, and 0.25° (range, -2.0° to 5.0°) for rotation around the sagittal axis. The median difference in cup orientation resulting from pelvic tilt error was 6° (range, 3°-13°) for anteversion and 3° (range, -1° to 5°) for inclination. There were no intra- or postoperative complications. The measured width of soft tissue layer anterior to the pelvic symphysis correlated significantly with the measured difference in cup inclination and anteversion. One centimeter of soft tissue anterior to the symphysis resulted in a median 2° (range, 1.75°-2.3°) difference in pelvic tilt. Ultrasound-assisted navigation in THA is a promising technology able to eliminate systematic errors in anterior pelvic plane orientation, in contrast to conventionally navigated THA using percutaneous palpation of landmarks or THA without navigational support.


Assuntos
Artroplastia de Quadril/métodos , Erros Médicos/prevenção & controle , Osteoartrite do Quadril/cirurgia , Cirurgia Assistida por Computador/instrumentação , Ultrassonografia/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Complicações Intraoperatórias , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Cirurgia Assistida por Computador/efeitos adversos , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento , Ultrassonografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA